EQUALLY SPACED 720' 20-
.(
APART 23 1/16' (58611n>
DIA B.C. (SEE DETAIL)
It
COVER & FRAME
A'
PLAN VIEW
[6nn1 r 127.1
1
I.--� 25' DIA.
I C6351WO
1•
3/4•
r E25..3
7
n91N 1I
-L
IL
54' MH
' a 3/4°
8' MIN.
2 Ile
I 24 MIN.
F• --�4- C222PI
C64.n]
TYP
1 8° MIN.
COVER SECTION VIEW
I 42° MIN, 1
26 1/2' DD
E673eW0
25 1/4' DD
EG41rn7
61.0 MA
EKE GASKET
23 3/8' DIA CL OPEN
[594MMI
27 5/16' DIA
C694rWO
34 UW DIA
[8671.4]
FRAME SECTION VIEW
COVER BOTTOM VIEW
(3) ELT St (ALLEN FEAR
5/8' -11 X iS SS
RUBBER WASHER
IWIL
EON BOLTING DETAIL
NOTES:
I. ALL COVERS SHALL BE LOCKING LID PER EAST
JORDAN IRON WORKS INC. No. 3717C1 OR EQUAL
2. USE FRAME AND COVER FOR STORM (SPECIFY
"BRAIN" ON COVER), SANITARY (SPECIFY
•'SEWER"). OR WATER (SPECIFY "WATER ").
PUBLIC Worm I . OW. rl -caw
DEPARTMENT MANHOLE FRAME AND COVER
DECEMBER 2008
7'
1
t
NOT TO SCALE -
MANHOLE FRAME AND COVER
SEE STD. PLAN 401
ADJUSTMENT RINGS (2° MIN.)
SEE NOTE 6
MORTAR JOINTS) (3/8' MIN.)
SEE NOTE 5
CONE (ECCENTRIC)
RUBBER GASKETED JOINTS IN
ACCORDANCE WITH ASTM C -443
STEPS - POLYPROPYLENE STEPS
SHALL BE INCLUDED
CONCRETE RISER BY PIPE INC,
OR APPROVED EQUAL
LADDER- POLYPROPYLENE
SHALL BE ATTACHED TO MANHOLE
MAX PIPE SIZE - 'E'
CONCRETE SHELF
`RECAST BASE SECTION
N CAST N SHELF.
A'
[27nN -
[6nn1 r 127.1
1
-61
{
48° MN
1 48'
nsa,Nl
I 5'MIN
-L
ve•
54' MH
GASKET GROOVE DETAIL
NOTES:
I. ALL COVERS SHALL BE LOCKING LID PER EAST
JORDAN IRON WORKS INC. No. 3717C1 OR EQUAL
2. USE FRAME AND COVER FOR STORM (SPECIFY
"BRAIN" ON COVER), SANITARY (SPECIFY
•'SEWER"). OR WATER (SPECIFY "WATER ").
PUBLIC Worm I . OW. rl -caw
DEPARTMENT MANHOLE FRAME AND COVER
DECEMBER 2008
7'
1
t
NOT TO SCALE -
MANHOLE FRAME AND COVER
SEE STD. PLAN 401
ADJUSTMENT RINGS (2° MIN.)
SEE NOTE 6
MORTAR JOINTS) (3/8' MIN.)
SEE NOTE 5
CONE (ECCENTRIC)
RUBBER GASKETED JOINTS IN
ACCORDANCE WITH ASTM C -443
STEPS - POLYPROPYLENE STEPS
SHALL BE INCLUDED
CONCRETE RISER BY PIPE INC,
OR APPROVED EQUAL
LADDER- POLYPROPYLENE
SHALL BE ATTACHED TO MANHOLE
MAX PIPE SIZE - 'E'
CONCRETE SHELF
`RECAST BASE SECTION
N CAST N SHELF.
NOTES.
1. STEPS TO BE POLYPROPYLENE SAFETY STEPS.
2. STEPS ARE TO BE N PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED.
3. CASTING SHALL BE PER STD. PUN 401.
4 MANHOLE SECTIONS 70 BE OF REINFORCED PRECAST CONCRETE _
5. ALL JOINTS BETWEEN THE CONE, RISER RINGS, BRICKS AND CASTING SHALL BE GROUTED.
6. ADJUSTMENT OF THE CASTING TO GRADE SHALL BE ACCOYPUSTEED NTH A COMBINATION OF
ADJUSTMENT RINGS BRICKS AND MORTAR OHL.L DRICKS SHALL BE STAGGERED TO CREATE A RUNNING
BOND OR 1/2 BOND. ME USE QE SNNq I PROMMRTRTI
7. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUDING CHANNELING.
COATED (SEALED) WITH A MGM SOLIDS URETHANE COATING: WASSER MC- ARDSHEID OR
APPROVED EQUAL: COLOR OF COATING SHALL BE %NM
a RUBBER GASKETED JOINTS SMALL BE IN CONFORMANCE WITH ASI11 C -443.
S. CHANNEL HEIGHT STALL BE A MINIMUM OF 3/4 OF THE INSIDE DIAMETER OF THE LARGEST PIPE
TO. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK ADAPTOR. KOR- N-SEAL DOOTS OR
APPROVED EQUAL
11. IN UNIMPROVED AREA:, MANHOLES SHAD. ECIElID A MINIMUM OF r AND A MAXIMUM OF 12°
ABOVE FINISHED GRADE OR MUST HAVE A MINIMUM 2- DIAMETER CONCRETE RINGS POURED AT GRADE.
N PAVED AREAS COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING
PUBIC WORKS SM. PI'/LN - 4001
a ' DEPARTMENT STANDARD SANITARY MANHOLE
SEPTEMBER 2011
SW 1/4, NE 1/4 SECTION 15, TOWNSHIP 23 N., RANGE 5 E., W.M.
EVERY iN0 Z4 LYEANOUT WYE WN -
ON OR [JADE 45' BEND ANO PLUG
IRFACE I '
V.
its
MORSE I HOOKE gl
PRWEHIY THE.
SWIM
All 90' tUWI6 9MLL BE ACLgIgl51ED
BY MEANS Qi M'E
ND A 45' B4D, ltd
IS' Boas 9IA A LL NOT BE ACGf➢TABLE
HOUSE �I L7_
aYm PIPE
I' 1FST 1FE WrN MYNn IMP@ $ PpR
LUG FACE ION OTHER THAN M4 LE FAMILY E r
TYFI FROPEDtt unE
A'
8'
C.
W
e
48° MN
1 48'
1 6- MN.
I 5'MIN
24° MIN.
21' 1.0.
54' MH
54°
8' MIN.
ID.D ° MN.
I 24 MIN.
24° I.D.
60° MH
60'
1 8° MIN.
1 6 MIN,
I 42° MIN, 1
1
30' I.D.
NOTES.
1. STEPS TO BE POLYPROPYLENE SAFETY STEPS.
2. STEPS ARE TO BE N PLACE BEFORE MANHOLE SECTIONS ARE INSTALLED.
3. CASTING SHALL BE PER STD. PUN 401.
4 MANHOLE SECTIONS 70 BE OF REINFORCED PRECAST CONCRETE _
5. ALL JOINTS BETWEEN THE CONE, RISER RINGS, BRICKS AND CASTING SHALL BE GROUTED.
6. ADJUSTMENT OF THE CASTING TO GRADE SHALL BE ACCOYPUSTEED NTH A COMBINATION OF
ADJUSTMENT RINGS BRICKS AND MORTAR OHL.L DRICKS SHALL BE STAGGERED TO CREATE A RUNNING
BOND OR 1/2 BOND. ME USE QE SNNq I PROMMRTRTI
7. SANITARY SEWER MANHOLES SHALL HAVE ALL INTERIOR SURFACES, INCLUDING CHANNELING.
COATED (SEALED) WITH A MGM SOLIDS URETHANE COATING: WASSER MC- ARDSHEID OR
APPROVED EQUAL: COLOR OF COATING SHALL BE %NM
a RUBBER GASKETED JOINTS SMALL BE IN CONFORMANCE WITH ASI11 C -443.
S. CHANNEL HEIGHT STALL BE A MINIMUM OF 3/4 OF THE INSIDE DIAMETER OF THE LARGEST PIPE
TO. CONNECTIONS TO MANHOLE SHALL BE MADE USING GPK ADAPTOR. KOR- N-SEAL DOOTS OR
APPROVED EQUAL
11. IN UNIMPROVED AREA:, MANHOLES SHAD. ECIElID A MINIMUM OF r AND A MAXIMUM OF 12°
ABOVE FINISHED GRADE OR MUST HAVE A MINIMUM 2- DIAMETER CONCRETE RINGS POURED AT GRADE.
N PAVED AREAS COVER MUST SLOPE IN ALL DIRECTIONS TO MATCH PAVING
PUBIC WORKS SM. PI'/LN - 4001
a ' DEPARTMENT STANDARD SANITARY MANHOLE
SEPTEMBER 2011
SW 1/4, NE 1/4 SECTION 15, TOWNSHIP 23 N., RANGE 5 E., W.M.
EVERY iN0 Z4 LYEANOUT WYE WN -
ON OR [JADE 45' BEND ANO PLUG
IRFACE I '
V.
its
MORSE I HOOKE gl
PRWEHIY THE.
SWIM
All 90' tUWI6 9MLL BE ACLgIgl51ED
BY MEANS Qi M'E
ND A 45' B4D, ltd
IS' Boas 9IA A LL NOT BE ACGf➢TABLE
HOUSE �I L7_
aYm PIPE
I' 1FST 1FE WrN MYNn IMP@ $ PpR
LUG FACE ION OTHER THAN M4 LE FAMILY E r
TYFI FROPEDtt unE
T
F ennm a6ce a octIlep rthI„bm�PdIaMN eHnlm aPn t e Wt ( mMeNbe1 ah TA6) m
a, b aabnn y a u1. N0 w6m.a1.. I,W n9m
em 0
. o 9 a 9 9.
£A 2 a q 0 a R 7. Al SWeq and
OR
'21 g U a m M . Pm ri-
e ~
NA mnlam to Bn rmst cant U tMaellm
I g' cop o4 0�_ tpulranmM m n the Rs stm4 Or..kw
m
_ `YP •fiknj 33 X At III ®wt ma .W w.ae Mrm nma WGmg Yr
m H�9 >y a aasmmw rilh e1myAM Jr0.K19 40s
z�9 i °m 10. live Vbl be a mEWmen 10 root 1"11 Ed WI II o m smiby" se.e. aM pus seNas mA a mYAmlp 5 feet
0 0 o V lA rParatim belveal aalltaY .Ne eswa ao! DL aUa
CALL FOR LOCATIONS BEFORE YOU DIG
48HR LOCATORS 1- 800 -424 -5555
PUBLIC WORKS TYPICAL BUILDING SEWER 3M. MEN - 40842
a a DEPARTMENT FROM PROPERTY LINE TO
$ BUILDING CONNECTION SEPTEMBER 2011
W (SEE NOTE 4)
BEDDING MATERIAL FOR
SANITARY SEWER PIPE
(SEE NOTE 6) -�
FOUNDATION LEVEL
LIMITS OF PIPE ZONE
t' T0"
OF PIPE
BEDDING FOR SANITARY SEWER PIPE
NOTES
1. PROVIDE UNIFORM SUPPORT UNDER BARREL.
2. HAND TAMP UNDER HAUNCHES.
3. COMPACT BEDDING MATERIAL TO 95% MAX. DENSITY EXCEPT DIRECTLY
OVER PIPE. HAND TAMP ONLY.
4. SEE "EXCAVATION AND PREPARATION OF TRENCH" IN THE SANITARY
SEWER SECTION
OF THE STANDARD SPECIFICATIONS FOR TRENCH
'MOTH "w' AND TRENCHING OPTIONS THE PIPE ZONE WILL BE THE
ACTUAL TRENCH WIDTH.
S. TRENCH BACKFILL SHALL CONFORM TO "BACKFILLING° IN THE SANITARY
SEWER SECTION OF THE STANDARD SPECIFICATIONS, EXCEPT THAT
ROCKS OR LUMPS LARGER THAN 1" PER FOOT OF PIPE DIAMETER
SHALL NOT BE USED IN THE BACKFILL MATERIAL.
6. PIPE ZONE MATERIAL SHALL BE "GRAVEL BACKFILL FOR DRAINS' AS
SPECIFIED IN THE AGGREGATES SECTION OF THE STANDARD
SPECIFICATIONS.
7. PIPE MUST BE ANCHORED IN SUCH A. MANNER AS TO ENSURE FLOW
LINE IS MAINTAINED.
PUBLIC WORKS I PIPE BEDDING STD' PLAN - 405
DEPARTMENT FOR SANITARY a EWERS
MARCH 2008
NO.
REVISION
6" BIALONG S PPE
BBUILDING DIIN
EWER NG SEWER
u _ _
-TEE WITH F' SIDE OUTLET - �I 6'%6'X6• WTE \2 "x 4" STUD MARKING POST PANTED
� SURFACE CIEANOUT WITH WHITE "IN THE WORD -SEWER- STENCILED
CAST RRON TEND h COYER N 3 -MGM BLACK L£1TER5 AND #6 "RE
(EAST JORDAN NON WORKS 'WRAPPED AROUND THE STUD AND
a '1975 OR APPROYTD EOl/V, EXTENDED TO THE 70P OF THE STUD.
S'EOFY 'SEWER' ON LED,
6" SIRE SEWER AN SEE STD. PLAN 403.1 FOR
INSTALLARDI)
ACCEPTABLE PROCEDLR(ES FOR SIDE SEWIIt CONNECT,,S TO MAW
LINES ARE AS FOLLOWS:
A MIRFED CLAY MAN'- CUT N A NEW TEE USING FLEXIBLE
COUPLINGS (FU NCO OR APPROVED EQUAL).
& CONCRErE MAIN - CORE - DRILLED WITH A ROMAC SADDE (Oft
APPROVED EQUAL).
G PVC MAIN - CORE- DRILLID WITH A ROMAC SADDLE (OR APPROVED
MAL) OR MY W A NEW TEE USING MM CQUPUNG9.
D. WCDLE IRO! MAN - CORE- DPoLLED WTTN A ROMAC SADDLE (OR
APPROVED EQUAL)
E MAN"XE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE
AT MANUFACTURED KNOCK -OUTS ON THE
STRUCTURE SHALL BE CORE-DRILLED.
60" ALLOWABLE MAX.
FOR CAST IRON PIPE
OR DUCTILE IRON PIPE.
1:3:5 MIX p5
CONCRE E
BLOCKING S4Y* N g5
YB
6" SIDE OUTLET TEE
6"
CONCRETE BLOCKING E
OF TFF AT MAIN OVER 95
ELEVATION
NOTE:
UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE
A MINIMUM 25' COVER AT PROPERTY LINE OR 3-5' LOWER
THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER.
FOE
SLOPE
PUBLIC WORKS STANDARD SIDE SEWER SM. PEN - 4084
DEPARTMENT INSTALLATION
(SEWER MAIN TO PROPERTY LINE) SEPTEMBER 2011
,'0ERGROUND PLII LOCATION BASED ON SURE A CC FE:.TU.RES. ACTUAL
LCCATTON MAY VARY.
C x N1'IRM fHAT THE LOCATIONS, ELEVATIONS D PIHS. AND AS -BUD.T
.'S'NTS RI?FLECIDIG MAMMALS ACTIOALL.1 LIED DUR[NO
r V 'TRLILTION, ACCURA'rBLY REPI.ECCS E J -: '' 3 PELLD CONDr1TONS AS
u::TLP,'SLN4D 13Y }}IE RUNDER MY DIRL•'?S;ii'E!:7;£ION O;d THIS
nATE
CHECKED FOR COMPLIANCE
TO CITY STANDARDS
Date Date
RECOMMENDED
FOR APPROVAL
BY
BY
BY
AS SHOWN `--1 CITY OF
RENTON
tla WOl DATUM
Planning /Building /Public Works Dept.
cWE Aolmv
C(` {3.5 - 3633�J
Utility Specifications
Sanitary Sewer Notes and Specifications
THESE NOTES SHALL APPEAR ON PROJECTS FOR THE WASTEWATER UTILITY.
I. All work and work material shall be in Conformance with the standards and specifications
of the City of Renton Planning /BUilding/Publk Works Department and the latest edition
of the WSDOT /APWA Standards and Specifications, as approved and modifier by the
City of Renton in the Renton Standard Plans & Specifications. A set of approved piers
shall be kept on site at all times during GDnstrTUtion.
2. The hours of work in the street right of way shall be per City specifications on weekdays
unless otherwise approved in writing by the Planning/Building/Public Works DepartiherlL
An approved traffic control plan must be obtained prior to beginning any work within
public right of way.
3. All locations of existing Utilities shown are approximate and it shall be the contractor's
responsibility to verify the true and correct location so as to avoid damage or
disturbance.
4. A pre - construction conference and a 24 hour notice shall be required prior to starting
new construction. It shall be the contadDes responsibility tb secure all necessary
permits prior to starting Const ruction. (Inspection will be accomplished by a
representative of the City of Renton.) It shall be the conbacWrs responsibility to notify
the Public Works inspector 24 hours in advance of bacldilling all construction.
S. Contractor is solely responsible for the means, methods and sequences of construction
and fw the safety of workers and others on the construction site.
6. It shall be the responsibility of the contractor to obtain street use and any other related
permits prior to any construction.
7. Plans approved by the Chy of Renton, Public Works Department shall take precedence
over all other plans.
8. A copy of these approved plans must be on the job site whenever construction is in
progress.
9. The contractor shall provide the City of Renton with an as -built drawing of the sanitary
sewer system, which has been stamped and signed by a licensed professional engineer
or licensed professional surveyor.
10. Badfill shall be placed equally on both skies of the pipe in layers with a loose average
depth of 6 inches, maximum depth of 8 inches, thoroughly tamping each layer to 95
percent of maximum density. These compacted layers must extend far one pipe
diameter on each side of the pipe or to the side Of the tench. Materials to complete the
fill over pipe shall be the same as described.
11. Open cut road crossings for utility bent hes on existing traveled roadway shall be
backfilled with crushed rock and mechanically Compacted unless OUhervvI approved by
12. Datum for Vertical Control shall be North American Vertical Datum 1988 Meters, and for
Horizontal Control shall be North American Datum 1983/1991 Meters unless otherwise
approved by the City of Renton Public Works Department Reference benchmark and
elevations are noted on the plans. _
13. All disturbed areas shall be seeded and mulched or otherwise stabilized to the
satisfaction of the Department for the prevention of OTT Ie erosion after the Completion
of construction.
14. All pipe and appurtenances shall be laid on a properly prepared foundation in
accordance with the standards and specifications of the City of Renton
Planning /Building /Public Works Department and the latest edition of the WSDOT /APWA
Standards and Specifications, as approved and modified by the City of Renton in the
Renton Standard Plans & Specifications. This shall include necessary leveling of the
trench bottom or the top of the founda&xh material, as well as placement and
compaction of required bedding material, to uniform grade so that the entire length of
the pipe will be supported on a uniformly dense, unyielding base. Pipe bedding shall be
pea gravel 6 inches above and below the pipe.
15. Sanitary sewer pipe shall be polyvinyl chloride (PVC) rubber gasketed ASTM D 3034,
SDR 35 (color shall be green
, or OLuctile Iron class 50, unless otherwise approved by the wastewater Utility.
16. In unimproved areas, manhole to extend minimum 6 inches and maximum 12 inches
above finished grade or must have minimum 2' diameter concrete ring poured at grade
In paved area, cover must slope in all drections to match paving.
5- 363304
1
UALtY- MORROW- POBLETE, INC.
S''00 726 AUBURN WAY N.
A AUBURN, WASHINGTON 98002
/cFi PHONE: 253- 333 -2200, FAX: 253- 333 -2206
0
z
3352( ENGINEERING - SURVEYING
S T E 6\ LAND PLANNING
L E� incorPO�acad
MAY. 2, 2012
SE. 2ND ST.
SANITARY SEWER NOTES AND DETAILStp6ss
•
OR
'z 1
N
Ny
rn 1
W
a
w
W
NOTES:
".p arrlw at qnp tW cane SYS se.a eM AIb NaW
Fl%NRS MAMNG
1. R b i� 0 s�Y . cmnclbn. R alWe-a.s
N WrmmW ken tlxe qty of Rehm
(' s• -0"
hwaa Do mat bolNF -ens caw mM WP1 M 9hm by the
OOD UI RWS LOCATED BnDW THE eEVA1KN
I E NF%T UPST EAW N UMQ E OO OF TIE
cwt
tits. Fh4 Q I N be s II aRa the If rd, IIII
BIC SEYrR SYSTEM. A BACKI
NGE VJcM AS OIEm C EXTENDAME
2 Tes of pbe eq 21
tmk hm D.m P MPW cot aM Hsd NN .m4
CKWATER VAVE W APPRDY7D MAL sIMLL FE
Mm be a[Pa.4 by 0I Dap b e1
s. Inrtm ehas xw .nn r aWlhxp mw.. 1b" w..r i. aM..a
k14XANY
IAIEID.
9mleh m'IPa by the mmu(aaNS. Mm be
4 tM naua N wWet M anmm.
RCOBIE COUPLING (FERNCD OR MAL)
V - I
A minkxen 9ratle m R (1/4' Da root)
AW CIEANNUT
MN 4• Pipe. H Ne F t 0 2X y04e m t 6e m b*eq the
4'k 4"x4" WYE
> Ilxnt eNn a City el Re 9WJe I` M lam ma
PRANG
EnNW B• Pie at . Wade alx
P Tot
6 BONN
4. Fa IRS m eMe ews, car 24 naW. F atlmm The
LOW VJN
ELEYABgR NW6E
e+Pee6e1 Mme numbs 4 m ine roe 4.a pamiL Ste
T
F ennm a6ce a octIlep rthI„bm�PdIaMN eHnlm aPn t e Wt ( mMeNbe1 ah TA6) m
a, b aabnn y a u1. N0 w6m.a1.. I,W n9m
em 0
. o 9 a 9 9.
£A 2 a q 0 a R 7. Al SWeq and
OR
'21 g U a m M . Pm ri-
e ~
NA mnlam to Bn rmst cant U tMaellm
I g' cop o4 0�_ tpulranmM m n the Rs stm4 Or..kw
m
_ `YP •fiknj 33 X At III ®wt ma .W w.ae Mrm nma WGmg Yr
m H�9 >y a aasmmw rilh e1myAM Jr0.K19 40s
z�9 i °m 10. live Vbl be a mEWmen 10 root 1"11 Ed WI II o m smiby" se.e. aM pus seNas mA a mYAmlp 5 feet
0 0 o V lA rParatim belveal aalltaY .Ne eswa ao! DL aUa
CALL FOR LOCATIONS BEFORE YOU DIG
48HR LOCATORS 1- 800 -424 -5555
PUBLIC WORKS TYPICAL BUILDING SEWER 3M. MEN - 40842
a a DEPARTMENT FROM PROPERTY LINE TO
$ BUILDING CONNECTION SEPTEMBER 2011
W (SEE NOTE 4)
BEDDING MATERIAL FOR
SANITARY SEWER PIPE
(SEE NOTE 6) -�
FOUNDATION LEVEL
LIMITS OF PIPE ZONE
t' T0"
OF PIPE
BEDDING FOR SANITARY SEWER PIPE
NOTES
1. PROVIDE UNIFORM SUPPORT UNDER BARREL.
2. HAND TAMP UNDER HAUNCHES.
3. COMPACT BEDDING MATERIAL TO 95% MAX. DENSITY EXCEPT DIRECTLY
OVER PIPE. HAND TAMP ONLY.
4. SEE "EXCAVATION AND PREPARATION OF TRENCH" IN THE SANITARY
SEWER SECTION
OF THE STANDARD SPECIFICATIONS FOR TRENCH
'MOTH "w' AND TRENCHING OPTIONS THE PIPE ZONE WILL BE THE
ACTUAL TRENCH WIDTH.
S. TRENCH BACKFILL SHALL CONFORM TO "BACKFILLING° IN THE SANITARY
SEWER SECTION OF THE STANDARD SPECIFICATIONS, EXCEPT THAT
ROCKS OR LUMPS LARGER THAN 1" PER FOOT OF PIPE DIAMETER
SHALL NOT BE USED IN THE BACKFILL MATERIAL.
6. PIPE ZONE MATERIAL SHALL BE "GRAVEL BACKFILL FOR DRAINS' AS
SPECIFIED IN THE AGGREGATES SECTION OF THE STANDARD
SPECIFICATIONS.
7. PIPE MUST BE ANCHORED IN SUCH A. MANNER AS TO ENSURE FLOW
LINE IS MAINTAINED.
PUBLIC WORKS I PIPE BEDDING STD' PLAN - 405
DEPARTMENT FOR SANITARY a EWERS
MARCH 2008
NO.
REVISION
6" BIALONG S PPE
BBUILDING DIIN
EWER NG SEWER
u _ _
-TEE WITH F' SIDE OUTLET - �I 6'%6'X6• WTE \2 "x 4" STUD MARKING POST PANTED
� SURFACE CIEANOUT WITH WHITE "IN THE WORD -SEWER- STENCILED
CAST RRON TEND h COYER N 3 -MGM BLACK L£1TER5 AND #6 "RE
(EAST JORDAN NON WORKS 'WRAPPED AROUND THE STUD AND
a '1975 OR APPROYTD EOl/V, EXTENDED TO THE 70P OF THE STUD.
S'EOFY 'SEWER' ON LED,
6" SIRE SEWER AN SEE STD. PLAN 403.1 FOR
INSTALLARDI)
ACCEPTABLE PROCEDLR(ES FOR SIDE SEWIIt CONNECT,,S TO MAW
LINES ARE AS FOLLOWS:
A MIRFED CLAY MAN'- CUT N A NEW TEE USING FLEXIBLE
COUPLINGS (FU NCO OR APPROVED EQUAL).
& CONCRErE MAIN - CORE - DRILLED WITH A ROMAC SADDE (Oft
APPROVED EQUAL).
G PVC MAIN - CORE- DRILLID WITH A ROMAC SADDLE (OR APPROVED
MAL) OR MY W A NEW TEE USING MM CQUPUNG9.
D. WCDLE IRO! MAN - CORE- DPoLLED WTTN A ROMAC SADDLE (OR
APPROVED EQUAL)
E MAN"XE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE
AT MANUFACTURED KNOCK -OUTS ON THE
STRUCTURE SHALL BE CORE-DRILLED.
60" ALLOWABLE MAX.
FOR CAST IRON PIPE
OR DUCTILE IRON PIPE.
1:3:5 MIX p5
CONCRE E
BLOCKING S4Y* N g5
YB
6" SIDE OUTLET TEE
6"
CONCRETE BLOCKING E
OF TFF AT MAIN OVER 95
ELEVATION
NOTE:
UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE
A MINIMUM 25' COVER AT PROPERTY LINE OR 3-5' LOWER
THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER.
FOE
SLOPE
PUBLIC WORKS STANDARD SIDE SEWER SM. PEN - 4084
DEPARTMENT INSTALLATION
(SEWER MAIN TO PROPERTY LINE) SEPTEMBER 2011
,'0ERGROUND PLII LOCATION BASED ON SURE A CC FE:.TU.RES. ACTUAL
LCCATTON MAY VARY.
C x N1'IRM fHAT THE LOCATIONS, ELEVATIONS D PIHS. AND AS -BUD.T
.'S'NTS RI?FLECIDIG MAMMALS ACTIOALL.1 LIED DUR[NO
r V 'TRLILTION, ACCURA'rBLY REPI.ECCS E J -: '' 3 PELLD CONDr1TONS AS
u::TLP,'SLN4D 13Y }}IE RUNDER MY DIRL•'?S;ii'E!:7;£ION O;d THIS
nATE
CHECKED FOR COMPLIANCE
TO CITY STANDARDS
Date Date
RECOMMENDED
FOR APPROVAL
BY
BY
BY
AS SHOWN `--1 CITY OF
RENTON
tla WOl DATUM
Planning /Building /Public Works Dept.
cWE Aolmv
C(` {3.5 - 3633�J
Utility Specifications
Sanitary Sewer Notes and Specifications
THESE NOTES SHALL APPEAR ON PROJECTS FOR THE WASTEWATER UTILITY.
I. All work and work material shall be in Conformance with the standards and specifications
of the City of Renton Planning /BUilding/Publk Works Department and the latest edition
of the WSDOT /APWA Standards and Specifications, as approved and modifier by the
City of Renton in the Renton Standard Plans & Specifications. A set of approved piers
shall be kept on site at all times during GDnstrTUtion.
2. The hours of work in the street right of way shall be per City specifications on weekdays
unless otherwise approved in writing by the Planning/Building/Public Works DepartiherlL
An approved traffic control plan must be obtained prior to beginning any work within
public right of way.
3. All locations of existing Utilities shown are approximate and it shall be the contractor's
responsibility to verify the true and correct location so as to avoid damage or
disturbance.
4. A pre - construction conference and a 24 hour notice shall be required prior to starting
new construction. It shall be the contadDes responsibility tb secure all necessary
permits prior to starting Const ruction. (Inspection will be accomplished by a
representative of the City of Renton.) It shall be the conbacWrs responsibility to notify
the Public Works inspector 24 hours in advance of bacldilling all construction.
S. Contractor is solely responsible for the means, methods and sequences of construction
and fw the safety of workers and others on the construction site.
6. It shall be the responsibility of the contractor to obtain street use and any other related
permits prior to any construction.
7. Plans approved by the Chy of Renton, Public Works Department shall take precedence
over all other plans.
8. A copy of these approved plans must be on the job site whenever construction is in
progress.
9. The contractor shall provide the City of Renton with an as -built drawing of the sanitary
sewer system, which has been stamped and signed by a licensed professional engineer
or licensed professional surveyor.
10. Badfill shall be placed equally on both skies of the pipe in layers with a loose average
depth of 6 inches, maximum depth of 8 inches, thoroughly tamping each layer to 95
percent of maximum density. These compacted layers must extend far one pipe
diameter on each side of the pipe or to the side Of the tench. Materials to complete the
fill over pipe shall be the same as described.
11. Open cut road crossings for utility bent hes on existing traveled roadway shall be
backfilled with crushed rock and mechanically Compacted unless OUhervvI approved by
12. Datum for Vertical Control shall be North American Vertical Datum 1988 Meters, and for
Horizontal Control shall be North American Datum 1983/1991 Meters unless otherwise
approved by the City of Renton Public Works Department Reference benchmark and
elevations are noted on the plans. _
13. All disturbed areas shall be seeded and mulched or otherwise stabilized to the
satisfaction of the Department for the prevention of OTT Ie erosion after the Completion
of construction.
14. All pipe and appurtenances shall be laid on a properly prepared foundation in
accordance with the standards and specifications of the City of Renton
Planning /Building /Public Works Department and the latest edition of the WSDOT /APWA
Standards and Specifications, as approved and modified by the City of Renton in the
Renton Standard Plans & Specifications. This shall include necessary leveling of the
trench bottom or the top of the founda&xh material, as well as placement and
compaction of required bedding material, to uniform grade so that the entire length of
the pipe will be supported on a uniformly dense, unyielding base. Pipe bedding shall be
pea gravel 6 inches above and below the pipe.
15. Sanitary sewer pipe shall be polyvinyl chloride (PVC) rubber gasketed ASTM D 3034,
SDR 35 (color shall be green
, or OLuctile Iron class 50, unless otherwise approved by the wastewater Utility.
16. In unimproved areas, manhole to extend minimum 6 inches and maximum 12 inches
above finished grade or must have minimum 2' diameter concrete ring poured at grade
In paved area, cover must slope in all drections to match paving.
5- 363304
1
UALtY- MORROW- POBLETE, INC.
S''00 726 AUBURN WAY N.
A AUBURN, WASHINGTON 98002
/cFi PHONE: 253- 333 -2200, FAX: 253- 333 -2206
0
z
3352( ENGINEERING - SURVEYING
S T E 6\ LAND PLANNING
L E� incorPO�acad
MAY. 2, 2012
SE. 2ND ST.
SANITARY SEWER NOTES AND DETAILStp6ss
•
OR
'z 1
N
Ny
rn 1
W
a
w
W
meat be ready la III mL tW to m me ebm
".p arrlw at qnp tW cane SYS se.a eM AIb NaW
be testa W CHI Yoke tN mmac}Im of 1M
(' s• -0"
hwaa Do mat bolNF -ens caw mM WP1 M 9hm by the
DORI DRAW
tits. Fh4 Q I N be s II aRa the If rd, IIII
Y{•
tmk hm D.m P MPW cot aM Hsd NN .m4
1D s -r
s. Inrtm ehas xw .nn r aWlhxp mw.. 1b" w..r i. aM..a
4 tM naua N wWet M anmm.
V - I
G X aMe x.a .tab W M ammla iM ems .nm by
T
F ennm a6ce a octIlep rthI„bm�PdIaMN eHnlm aPn t e Wt ( mMeNbe1 ah TA6) m
a, b aabnn y a u1. N0 w6m.a1.. I,W n9m
em 0
. o 9 a 9 9.
£A 2 a q 0 a R 7. Al SWeq and
OR
'21 g U a m M . Pm ri-
e ~
NA mnlam to Bn rmst cant U tMaellm
I g' cop o4 0�_ tpulranmM m n the Rs stm4 Or..kw
m
_ `YP •fiknj 33 X At III ®wt ma .W w.ae Mrm nma WGmg Yr
m H�9 >y a aasmmw rilh e1myAM Jr0.K19 40s
z�9 i °m 10. live Vbl be a mEWmen 10 root 1"11 Ed WI II o m smiby" se.e. aM pus seNas mA a mYAmlp 5 feet
0 0 o V lA rParatim belveal aalltaY .Ne eswa ao! DL aUa
CALL FOR LOCATIONS BEFORE YOU DIG
48HR LOCATORS 1- 800 -424 -5555
PUBLIC WORKS TYPICAL BUILDING SEWER 3M. MEN - 40842
a a DEPARTMENT FROM PROPERTY LINE TO
$ BUILDING CONNECTION SEPTEMBER 2011
W (SEE NOTE 4)
BEDDING MATERIAL FOR
SANITARY SEWER PIPE
(SEE NOTE 6) -�
FOUNDATION LEVEL
LIMITS OF PIPE ZONE
t' T0"
OF PIPE
BEDDING FOR SANITARY SEWER PIPE
NOTES
1. PROVIDE UNIFORM SUPPORT UNDER BARREL.
2. HAND TAMP UNDER HAUNCHES.
3. COMPACT BEDDING MATERIAL TO 95% MAX. DENSITY EXCEPT DIRECTLY
OVER PIPE. HAND TAMP ONLY.
4. SEE "EXCAVATION AND PREPARATION OF TRENCH" IN THE SANITARY
SEWER SECTION
OF THE STANDARD SPECIFICATIONS FOR TRENCH
'MOTH "w' AND TRENCHING OPTIONS THE PIPE ZONE WILL BE THE
ACTUAL TRENCH WIDTH.
S. TRENCH BACKFILL SHALL CONFORM TO "BACKFILLING° IN THE SANITARY
SEWER SECTION OF THE STANDARD SPECIFICATIONS, EXCEPT THAT
ROCKS OR LUMPS LARGER THAN 1" PER FOOT OF PIPE DIAMETER
SHALL NOT BE USED IN THE BACKFILL MATERIAL.
6. PIPE ZONE MATERIAL SHALL BE "GRAVEL BACKFILL FOR DRAINS' AS
SPECIFIED IN THE AGGREGATES SECTION OF THE STANDARD
SPECIFICATIONS.
7. PIPE MUST BE ANCHORED IN SUCH A. MANNER AS TO ENSURE FLOW
LINE IS MAINTAINED.
PUBLIC WORKS I PIPE BEDDING STD' PLAN - 405
DEPARTMENT FOR SANITARY a EWERS
MARCH 2008
NO.
REVISION
6" BIALONG S PPE
BBUILDING DIIN
EWER NG SEWER
u _ _
-TEE WITH F' SIDE OUTLET - �I 6'%6'X6• WTE \2 "x 4" STUD MARKING POST PANTED
� SURFACE CIEANOUT WITH WHITE "IN THE WORD -SEWER- STENCILED
CAST RRON TEND h COYER N 3 -MGM BLACK L£1TER5 AND #6 "RE
(EAST JORDAN NON WORKS 'WRAPPED AROUND THE STUD AND
a '1975 OR APPROYTD EOl/V, EXTENDED TO THE 70P OF THE STUD.
S'EOFY 'SEWER' ON LED,
6" SIRE SEWER AN SEE STD. PLAN 403.1 FOR
INSTALLARDI)
ACCEPTABLE PROCEDLR(ES FOR SIDE SEWIIt CONNECT,,S TO MAW
LINES ARE AS FOLLOWS:
A MIRFED CLAY MAN'- CUT N A NEW TEE USING FLEXIBLE
COUPLINGS (FU NCO OR APPROVED EQUAL).
& CONCRErE MAIN - CORE - DRILLED WITH A ROMAC SADDE (Oft
APPROVED EQUAL).
G PVC MAIN - CORE- DRILLID WITH A ROMAC SADDLE (OR APPROVED
MAL) OR MY W A NEW TEE USING MM CQUPUNG9.
D. WCDLE IRO! MAN - CORE- DPoLLED WTTN A ROMAC SADDLE (OR
APPROVED EQUAL)
E MAN"XE CONNECTION - ALL CONNECTIONS TO MANHOLES SHALL BE
AT MANUFACTURED KNOCK -OUTS ON THE
STRUCTURE SHALL BE CORE-DRILLED.
60" ALLOWABLE MAX.
FOR CAST IRON PIPE
OR DUCTILE IRON PIPE.
1:3:5 MIX p5
CONCRE E
BLOCKING S4Y* N g5
YB
6" SIDE OUTLET TEE
6"
CONCRETE BLOCKING E
OF TFF AT MAIN OVER 95
ELEVATION
NOTE:
UNLESS OTHERWISE SHOWN ON PLAN, SIDE SEWER SHALL HAVE
A MINIMUM 25' COVER AT PROPERTY LINE OR 3-5' LOWER
THAN THE LOWEST HOUSE ELEVATION, WHICHEVER IS LOWER.
FOE
SLOPE
PUBLIC WORKS STANDARD SIDE SEWER SM. PEN - 4084
DEPARTMENT INSTALLATION
(SEWER MAIN TO PROPERTY LINE) SEPTEMBER 2011
,'0ERGROUND PLII LOCATION BASED ON SURE A CC FE:.TU.RES. ACTUAL
LCCATTON MAY VARY.
C x N1'IRM fHAT THE LOCATIONS, ELEVATIONS D PIHS. AND AS -BUD.T
.'S'NTS RI?FLECIDIG MAMMALS ACTIOALL.1 LIED DUR[NO
r V 'TRLILTION, ACCURA'rBLY REPI.ECCS E J -: '' 3 PELLD CONDr1TONS AS
u::TLP,'SLN4D 13Y }}IE RUNDER MY DIRL•'?S;ii'E!:7;£ION O;d THIS
nATE
CHECKED FOR COMPLIANCE
TO CITY STANDARDS
Date Date
RECOMMENDED
FOR APPROVAL
BY
BY
BY
AS SHOWN `--1 CITY OF
RENTON
tla WOl DATUM
Planning /Building /Public Works Dept.
cWE Aolmv
C(` {3.5 - 3633�J
Utility Specifications
Sanitary Sewer Notes and Specifications
THESE NOTES SHALL APPEAR ON PROJECTS FOR THE WASTEWATER UTILITY.
I. All work and work material shall be in Conformance with the standards and specifications
of the City of Renton Planning /BUilding/Publk Works Department and the latest edition
of the WSDOT /APWA Standards and Specifications, as approved and modifier by the
City of Renton in the Renton Standard Plans & Specifications. A set of approved piers
shall be kept on site at all times during GDnstrTUtion.
2. The hours of work in the street right of way shall be per City specifications on weekdays
unless otherwise approved in writing by the Planning/Building/Public Works DepartiherlL
An approved traffic control plan must be obtained prior to beginning any work within
public right of way.
3. All locations of existing Utilities shown are approximate and it shall be the contractor's
responsibility to verify the true and correct location so as to avoid damage or
disturbance.
4. A pre - construction conference and a 24 hour notice shall be required prior to starting
new construction. It shall be the contadDes responsibility tb secure all necessary
permits prior to starting Const ruction. (Inspection will be accomplished by a
representative of the City of Renton.) It shall be the conbacWrs responsibility to notify
the Public Works inspector 24 hours in advance of bacldilling all construction.
S. Contractor is solely responsible for the means, methods and sequences of construction
and fw the safety of workers and others on the construction site.
6. It shall be the responsibility of the contractor to obtain street use and any other related
permits prior to any construction.
7. Plans approved by the Chy of Renton, Public Works Department shall take precedence
over all other plans.
8. A copy of these approved plans must be on the job site whenever construction is in
progress.
9. The contractor shall provide the City of Renton with an as -built drawing of the sanitary
sewer system, which has been stamped and signed by a licensed professional engineer
or licensed professional surveyor.
10. Badfill shall be placed equally on both skies of the pipe in layers with a loose average
depth of 6 inches, maximum depth of 8 inches, thoroughly tamping each layer to 95
percent of maximum density. These compacted layers must extend far one pipe
diameter on each side of the pipe or to the side Of the tench. Materials to complete the
fill over pipe shall be the same as described.
11. Open cut road crossings for utility bent hes on existing traveled roadway shall be
backfilled with crushed rock and mechanically Compacted unless OUhervvI approved by
12. Datum for Vertical Control shall be North American Vertical Datum 1988 Meters, and for
Horizontal Control shall be North American Datum 1983/1991 Meters unless otherwise
approved by the City of Renton Public Works Department Reference benchmark and
elevations are noted on the plans. _
13. All disturbed areas shall be seeded and mulched or otherwise stabilized to the
satisfaction of the Department for the prevention of OTT Ie erosion after the Completion
of construction.
14. All pipe and appurtenances shall be laid on a properly prepared foundation in
accordance with the standards and specifications of the City of Renton
Planning /Building /Public Works Department and the latest edition of the WSDOT /APWA
Standards and Specifications, as approved and modified by the City of Renton in the
Renton Standard Plans & Specifications. This shall include necessary leveling of the
trench bottom or the top of the founda&xh material, as well as placement and
compaction of required bedding material, to uniform grade so that the entire length of
the pipe will be supported on a uniformly dense, unyielding base. Pipe bedding shall be
pea gravel 6 inches above and below the pipe.
15. Sanitary sewer pipe shall be polyvinyl chloride (PVC) rubber gasketed ASTM D 3034,
SDR 35 (color shall be green
, or OLuctile Iron class 50, unless otherwise approved by the wastewater Utility.
16. In unimproved areas, manhole to extend minimum 6 inches and maximum 12 inches
above finished grade or must have minimum 2' diameter concrete ring poured at grade
In paved area, cover must slope in all drections to match paving.
5- 363304
1
UALtY- MORROW- POBLETE, INC.
S''00 726 AUBURN WAY N.
A AUBURN, WASHINGTON 98002
/cFi PHONE: 253- 333 -2200, FAX: 253- 333 -2206
0
z
3352( ENGINEERING - SURVEYING
S T E 6\ LAND PLANNING
L E� incorPO�acad
MAY. 2, 2012
SE. 2ND ST.
SANITARY SEWER NOTES AND DETAILStp6ss
•