HomeMy WebLinkAboutS-373202NE 114, NW 114, SEC.14, TWP.23N., RGE, 5E., W.M.
I
w
i
w V
LL _q V i 11 \ 1 1 10
I I I FFE =473.7 I I \FFE =478.8 I I 9 \ I
II I A FFE =483.9 8
IE
i
=468.2 I I I FE =488.5
IE =473:3 j SSMH 250 I�
1 j 2 STA,32 +34.81, 4.43' LT
SSMH 230 ; I I 1 WATER SERVICE (TIP.) I
2 STA 30 +10.89, 5.01' LT k0 - SSMH240 I __ IE -4j8.4 A
z Q I \ \ \ \\ 2 STA 31 +68_36, 5.59' LT
Y i i i _�� ��- I \ �ro �I - �' _ `�I ROW_ / I• -
Lu
o_ d 30fObi IS_r SS 10 SS1+ -SS SS
� I
/y-
O ' ;II W W IW �' W yT-- L-I� -W
ZO
Lu
I W
41
Lj
\\
I I; I r ,•I
-
,--- TRA_CTA
F, I I ! i 27,234 5F
SEE C4.04
LOW PT STA: 30 +30.27
LOW PT EL: 471.27
500 PW STA: 30 +45.00 O 500
PW EL: 470.87
50.00' VC
°o °o
NM O� W
SSMH 250, TYPE 1 41
490 ° ^ w°+. w RIM= 485.23 _ 490
OQ
�2 UU
UU
IM= O
W IE = 477.73
J
IE(E)= 471.94
I�
o
IE(W)= 471.84
_- - -_ _ - -
480
y
+ 480
'¢-Z -w+
a. PVC
66L
- --
- -_- -_-
1�
- 200, --
-
-
5 =0.0871
470
- -_- - -- -_ -
W 470
158LF 8" PVC
1=-I
Z
- -- _ - -_ -- -
a - - - -- _
g.0.0 4
J
=
70'
24'
460 33MH230, TYPE
1
Q! 460
IM =4 .
C
450 450
CONSTRUCTION NOTES
O6" SIDE SEWER CONNECTION W/CLEANOUT, 2% MIN.
SLOPE PER CDR STD. PLAN 406.1 AND 403.1
O48" SANITARY SEWER MANHOLE TYPE 1 W1 FRAME AND
COVER PER COR STD. PLAN 400.1 AND 401
3O SANITARY SEWER CLEANOUT PER CDR STD. PLAN 403.1
4O SAWCUT EXIST. PVMT.
OCONNECT 6" SIDE SEWER TO MANHOLE PER CDR STD.
PLAN 406.1
GENERAL NOTES:
1. THE INVERT ELEVATION FOR INDIVIDUAL SANITARY SEWER
SERVICE CONNECTION STUBS SHALL BE SET A MIN. OF 5
FEET BELOW THE FINISHED FLOOR ELEVATION (FFE).
2 PIPE BEDDING FOR SANITARY SEWER MAIN SHALL BE PER
COR STD. PLAN 405.
3. ALL SANITARY SEWER MANHOLES ARE TYPE 1 PER CDR
STD. PLAN 400.1 AND 401.
4. PAVEMENT RESTORATION SUBJECT TO FIELD MODIFICATION
BY THE CITY INSPECTOR.
5. PER CITY OF RENTON TRENCH RESTORATION DETAILS, IF
TRENCHING IS IMTHIN 3 FEET OF AN ADJACENT LANE, THE
ENTIRE ADJACENT TRAVEL LANE AFFECTED WILL BE
REPA VED.
6. IF THERE IS LESS THAN 12 INCHES SEPARATION BETWEEN
UTILITY PIPES AT CROSSLINE, AN ETHAFORM PAD SHALL BE
PROVIDED.
I 7_ T,-1 i
8161
440 440 N,
r~e
ELEVATION AT EXIST. GROUND h
ELEVATION AT FINISH GRADE R 37610 FO c P H
6 GISTBR ♦�
430 430 ss1Is'r
S=37320ftAmNefiTng
-2 CALLBEFORE land Uw Consulting RaJectMamgement
30 +00 30 +40 30 +80 31 +20 31 +60 32 +00 32 +40 YOU45 1337Me..5uae100 I✓1A M.WA9a0.i3
7- 800424 -5555 pfane:(42 )28& teol F0.c10s512✓ 2369
www.cphconsultants.com
0 30 20 CITY OF RENTON 1 CITY OF RENTON PERMIT SUBMITTAL JBS 5/30/14 JBS sM EVANS PILS N/A rRnrx Ran °0i MAPLEWOOD PARK EAST "1e5 /30/14
Approved by: a Date:
pEWaEO: HpR91w/L' WD �YBa lW, •, >3- CITY OF
VERT. IN FEET RYAN SCHAUBLE ROADWAY GRADING, DRAINAGE AND SANITARY SEWER IMPROVEMENTS
0 20 40 Approved b Date: RENTON
UTILITY PERMIT PP Y PETER EVANS ae acx DATUM '
HOR17 IN FEET NO. U13002729 Approved by: Date: AMMI B. SCHROEDER, PE i m w� Planning /Building /Public Works Dept. SANITARY SEWER PLAN AND PROFILE (�'4.0'Z
N0. REVISION BY DATE APPR''
Com+i0w 02013 CH COreuM LLC. All Ri6ft R¢SU -A rovedb: Date: 10( APPROVED am: 26 a36
A NINNNA�
rn
m �
ro °O- O
d w
m d l
N c�
�� I