Loading...
HomeMy WebLinkAboutS-373203w z U w 'o a NE 114, NW 114, SEC.14, TWP.23N., RGE. 5E, W.M. CONSTRUCTION NOTES w SEE C4.01 O 6" SIDE SEWER CONNECTION W /CLEANOUT, 2Z MIN. 5 ° " SLOPE PER COR STD. PLAN 406.1 AND 403.1 I l j FFE =503.1 UJ I I I I • U) 4 O 48" SANITARY SEWER MANHOLE TYPE 1 W/ FRAME AND COVER PER COR STD. PLAN 400.1 AND 401 J SANITARY SEWER CLEANOUT PER COR STD. PLAN 403.1 - � 4 SAWCUT EXIST PVMT F ----- -- - - -- E =488.5 l FFE =492.9 l I I 3 ` �/ O CONNECT CT 6" SIDE SEWER TO MANHOLE PER COR ST P D. ,y 8 t' GENERAL NOTES: Q WATER SERVICES (TIP.) I I fE -4824 FFE =501.2 - j � nl � I I I � I 1. THE INVERT ELEVATION FOR INDIVIDUAL SANITARY SEWER _ _ _ Z j - -- SERVICE CONNECTION STUBS SHALL BE SET A MIN. OF 5 O IE 483.0 I � _ I � � W rI' s' ' I 3 FEET BELOW THE FINISHED FLOOR ELEVATION (FFE). W �'° 41�\ ` 1-• -�\ _ 7 li Q FFE =500.5 2. PIPE BEDDING FOR SANITARY SEWER MAIN SHALL BE PER Q CDR STD. PLAN 405. � __ROW oe� S ,� - - -- � � I � I � I 3. ALL SANITARY SEWER MANHOLES ARE TYPE i PER COR Oct STD. PLAN 400.1 AND 401. O SS \ i 4 m _- _ Z 4. PAVEMENT RESTORATION SUBJECT TO FIELD MODIFICATION '` - -- / BY THE CITY INSPECTOR * ss 1 I +oSs NE 2ND LANE - �i� 5 PER CITY OF RENTON TRENCH RESTORATION DETAILS, IF J " ;,d ,: c. W `. yy 5 - - -�' -_ N Ij I - - -- -- -- -- -- IS WIT TRAVEL LANE AFFECTED WILL A THE R. Q• W W W � _ , y ENTIRE 1 ADJACENT S WITHIN 3 FEET OF AN ADJACENT LANE, W yy REPAVED. 6. IF THERE IS LESS THAN 12 INCHES SEPARATION BETWEEN UTILITY PIPES AT CROSSLINE, AN ETHAFORM PAD SHALL BE PROVIDED. 2 1wr A� 2 SSMH 260 STA 33 +28.92, 5.00' LT IE =484.8 IE =4889 I I 12 13 14 �I� FFE =490.0 '• I I FFE =493.7 I FFE =496.5 � �___ II SEE C4.01 520 i 520 ¢� PVl STA: 33 +50.00 -' ¢ PVI EL: 494.48 Z o 200.00' VC `" O 510 510 h� hI�o �Mb NO + d +uS ro M� EXISTING GRADE v +II V &ii cd ® ROADWAY CL 0i Q L`+w W vi m m 500 500 W FINISH GRADE ® 8" WATER MAIN 2.27% ROADWAY - - - - _ 490 _ -- _ -`^ 490 : Q - - - - - :4LF 8" PVC y �e 480 I� 480 Q rt' 'a* , x Vi $- 0.0620 SSMH 260, TYPE 1 4 � P W RIM = 491.64 Z 15' 7' IE(W)= 483.64 vQi 470 470 KEYMAP I 49"910MAL tV1 460 460 ELEVATION AT EXIST. GROUND ELEVATION AT FINISH GRADE P T T Y 1 ^uj 450 450 S=3732,03 CONSULTANTS oI h m N W •D ° b v N Id ri W O ci N rn M c1 �' � o� h Site Planning • Ciril Engineering CALL BEFORE lyM ConsuNng • Roject Management 32 +40 32 +80 33 +20 33 +60 34 +00 34 +40 34 +80 YOU 733 7th Suns IOM l Nn M, WA 99033 7. 800424 -5555 Fmre:(425)2852390l FAR(C29)2 2399 www.cphconsuliants.com 0 10 20 CITY OF RENTON 1 CITY OF RENTON PERMIT SUBMITTAL JBS 5/30/14 JBS M cn e/aNS FLS N/A C, MAPLEWOOD PARK EAST 5 /30/14 ' M1 r >} CITY 0 F Approved by: Date VERT. IN FEET RYAN SCHAUBIE RENTON ROADWAY GRADING, DRAINAGE AND SANITARY SEWER IMPROVEMENTS ° 20 40 UTILITY PERMIT Approved by: Date: °PN" PETER EVANS nw.w Hu DATUM /I HORIZ. IN FEET NO. U13002729 Approved by: Date: JAMIE BB. SCHROEDER, PE A",.,, Planning /Building /Public Works Dept. SANITARY SEWER PLAN AND PROFILE CiY.03 COMTW020nMHW5 UMLMMIWW,6P¢sMV ¢ p. Approved b : P"' Date: NO. REVISION BY DATE APPR "Pp1p^ApPROVEO Y 27 X36 cD S 3�3a� A- NNNNAA 0; r O �m0 �^ X a y