ILLUMINATION CONSTRUCTION NOTES �i o
2 GENERAL NOTES
II� Q
INSTALL FOUNDATION, POLE, LUMINAIRE, AND JUNCTION BOX PER ILLUMINATION
W I 3 5 1. ALL WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF OPOLE SCHEDULE, SHEET ILIA, AND PER CITY OF RENTON STD PLANS 115, 119, 3
THE CITY OF RENTON UTILITY DEPARTMENT AND THE LATEST EDITION OF THE WSDOT/APWA 120, 121, & J013. N
W STANDARDS AND SPECIFICATIONS. A SET OF APPROVED PLANS SHALL BE KEPT ON -SITE AT ALL INSTALL FOUNDATION POLE LUMINAIRE AND JUNCTION BOX PER ILLUMINATION
> TIMES DURING CONSTRUCTION. -
I Q OPOLE SCHEDULE, SHEET ILIA, AND PER CITY OF RENTON STD PLANS 116.1, 119, �
O . + l V 2. THE HOURS OF WORK IN THE STREET RIGHT -OF -WAY SHALL BE LIMITED TO 8:30 AM TO 3:30 P.M. 2
120, & 121.
ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE DEPARTMENT OF PUBLIC WORKS. I
'! CONSTRUCT SERVICE CABINET FOUNDATION PER CITY OF RENTON STD PLAN 126.1. 1 - i
ItII ALL STREET CLOSURES, PARTIAL OR FULL, SHALL BE APPROVED BY THE DEPARTMENT OF PUBLIC O
WORKS 24 HOURS IN ADVANCE. THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911 SHALL BE FURNISH AND INSTALL SERVICE CABINET PER CITY OF RENTON STD PLAN 122.1 & 13
' NOTIFIED 24 HOURS IN ADVANCE. 123. LOCATION AND ORIENTATION OF FOUNDATION AND CABINET SHALL BE
O VERIFIED BY CITY OF RENTON INSPECTOR PRIOR TO INSTALLATION OF CONDUITS.
3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE 3
�I! O4 EXISTING STREET LIGHT POLE TO REMAIN. o°
CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID
x
' I DAMAGE OR DISTURBANCE. FOR UTILITY LOCATE CALL 48 -HOUR LOCATORS, 1- 800 - 424 -5555.
POWER SOURCE CONNECTION POINT UNKNOWN AT THE TIME OF PLAN 31 I�
4. A PRECONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING OPREPARATION. CONTRACTOR SHALL COORDINATE WITH PSE FOR SPECIFIC
REQUIREMENTS. PSE TO PROVIDE 1201240 VOLT SINGLE PHASE POWER SOURCE. 3
3 NEW CONSTRUCTION. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO SECURE ALL NECESSARY
I PERMITS PRIOR TO STARTING CONSTRUCTION. (INSPECTION WILL BE ACCOMPLISHED BY A CONTRACTOR SHALL COORDINATE WITH PSE FOR SERVICE CABINET ELECTRICAL �, I i•
HOOK -UP, SHALL PREPARE /SUBMIT ALL APPLICABLE PERMITS, AND SHALL PAY
REPRESENTATIVE OF THE CITY OF RENTON). IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO ALL ASSOCIATED FEES. I I I
NOTIFY THE UTILITY DEPARTMENT 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION.
MATCH LINE STA 0 +50
SEE SHEET I0
ILLUMINATION LEGEND
EXISTING NEW
DESCRIPTION
m D
JUNCTION BOX TYPE 1, 2
o-
STANDARD DAVIT POLE
x
DECORATIVE POLE
- - - --
CONDUIT /CONDUCTOR
®
SERVICE CABINET
O
CONSTRUCTION NOTE
O
LUM. POLE NO.
QWIRE
NOTE
5. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF
CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE.
6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER
RELATED PERMITS PRIOR TO ANY CONSTRUCTION.
7. PLANS APPROVED BY THE DIRECTOR OF PUBLIC WORKS SHALL TAKE PRECEDENCE OVER ALL OTHER
PLANS.
B. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION
IS IN PROGRESS.
9. ALL UTILITY TRENCHES SHALL BE BACKFILLED AND COMPACTED TO 95% MAXIMUM DRY DENSITY
MODIFIED PROCTOR.
10. THE CONTRACTOR SHALL PROVIDE MATERIALS SUBMITTALS AND POLE SHOP DRAWINGS TO THE CITY
OF RENTON FOR APPROVAL AT THE EARLIEST POSSIBLE DATE.
11. AS PART OF THE DESIGN PROCESS, THE ENGINEER HAS ATTEMPTED TO CONFIRM THAT THERE ARE
NOT CONFLICTS WITH OVERHEAD POWER LINES OR SUBSURFACE UTILITIES. HOWEVER, IT IS
POSSIBLE FOR THE EXISTING OR PROPOSED CONDITIONS TO CHANGE PRIOR TO IMPLEMENTATION OF
THE SCOPE OF WORK IDENTIFIED ON THESE DOCUMENTS. AS THE FIRST ORDER OF BUSINESS, THE
CONTRACTOR SHALL POTHOLE EACH POLE LOCATION TO CONFIRM THAT THERE ARE NOT CONFLICTS
WITH SUBSURFACE UTILITIES. ADDITIONALLY, THE CONTRACTOR SHALL CONFIRM THAT THERE IS A
MINIMUM 10 -FT CLEARANCE PROVIDED BETWEEN OVERHEAD POWER LINES AND THE PROPOSED
LUMINAIRE POLES PRIOR TO POLE PLACEMENT. ADDITIONAL CLEARANCE MAY BE REQUIRED AS
DIRECTED BY THE UTILITY. THE CONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY IF A
CONFLICT IS DISCOVERED.
ILLUMINATION WIRING DIAGRAM
i1
W W
Z
Z 6 8 10
> NE 2 LANE 12 >
Q 7 9 Q
0 3
O
Q 5 Q
N SERVICE 1 2
ILLUM A N
LJ
ILLUM B
1 2 3 4
SE 132ND ST NOT TO SCALE
4
MATCH LINE STA 20 +75
SEE SHEET IL 1 T=373202
SERVICE BREAKER SCHEDULE
CIRCUIT
BREAKER
CONTACTOR
MAIN
2P -100 AMP
- --
ILLUM A
2P -20 AMP
30 AMP
ILLUM B
2P -20 AMP
30 AMP
10 40
0 20 60
SCALE IN FEET
VTENW