EXISTING 18' OUTLET
TO BIOSWALE
INVERT = 17.5
NEW 18" TEE
STRUCTURE INSTALL
PER DETAIL 2 ON
THIS SHEET
PIPE 4, DISCHARGE
TO STRUCTURE 3,
E STORMFILTER
CARTRIDGE
TREATMENT SYSTEM
F
111
It
J
K
L
in
\
\
EXISTING 12" INLET
INVERT = 17.7
i
NOTE:
1. CONTRACTOR TO CONFIRM SIZE, INVERT
AND LOCATION OF INLET AND OUTLET
PIPES.
2. MAINTAIN A MINIMUM 24" CLEARANCE
BETWEEN EXISTING STEPS/LADDER AND
NEW TEE STRUCTURE.
EXISTING 18" INLET
INVERT = 17.3
INLET
INVERT = 17.2
EXISTING CB WITH TEE
NON — SHRINK GROUT
GALV STEEL STRAPS
W /ANCHOR BOLTS
COUPLING
WITH WATER
TIGHT SEAL.
PVC TEE (SCH. 40)
CATCH
BASIN (SAME 6
AS OUTLET PIPE).
1/2 PIPE 0
CONTROL
PIPE 4, DISCHARGE TO
STRUCTURE 3, STORMALTER
CARTRIDGE TREATMENT
TRASH RACK caz
--PIPE END INVERT 20.35'
/-RIP RAP aez
/ i 1%
SEED BIOSWALE PER THE FOLLOWING SEED MIXTURE:
GRASS SEED MIX 1 SUITABLE FOR BIOFILTRATION SWALE TREATMENT AREAS
(TABLE 6.3.1.0 OF THE 2009 KCSWDM)
75 -80% TALL OR MEADOW FESCUE
10 -15% SEASIDE CREEPING BENTGRASS OR COLONIAL BENTGRASS
5 -10% RED TOP
(NOTE ALL PERCENTAGES ARE BY WEIGHT)
PLAN VIEW L- B
1' CHECK DAM,
SEE NOTES
BELOW.
VIEW A —A
aas TRASH RACK
1' CHECK DAM, PIPE END INVERT 21.50'
SEE NOTES
BELOW. a RIP RAP
1% aex
20';
CHECK DAM NOTES
1. CHECK DAMS SHALL BE 1' HIGH WITH 2:1 SIDE SLOPES AND 1' KEYED BELOW
SWALE BOTTOM.
2. CHECK DAMS SHALL BE CONSTRUCTED OF RIP RAP IN ACCORDANCE WITH
SECTION 9 -13.1 OF THE WSDOT STANDARD SPECIFICATIONS AND SHALL BE
RESONALLY WELL GRADED AS FOLLOWS:
100% PASSING 8" SIEVE
40 -60% PASSING 6" SIEVE
0 -10% PASSING 2" SIEVE
FAIM
H:1 "= 5'V:1 " =10'
FOUNDATION SUBSURFACE PREP NOTES I NW 1/4 OF S 19, T 23, R 5 E
UNLESS SPECIFICALLY INDICATED OTHERWISE IN THE DRAWINGS AND /OR SPECIFICATIONS, THE UMITS OF THIS SUBSURFACE PREPARATION ARE CONSIDERED TO BE THAT
PORTION OF THE SITE DIRECTLY BENEATH AND 5 FEET BEYOND THE BUILDING AND APPURTENANCES. APPURTENANCES ARE THOSE ITEMS ATTACHED TO THE BUILDING
PROPER (REFER TO DRAWING SHEET SP1) TYPICALLY INCLUDING, BUT NOT LIMITED TO, THE BUILDING SIDEWALKS, GARDEN CENTER, PORCHES, RAMPS, STOOPS, TRUCK
WELLS /DOCKS, CONCRETE APRONS AT THE AUTOMOTIVE CENTER, COMPACTOR PAD, ETC. THE BASE AND THE VAPOR BARRIER, WHERE REQUIRED, DO NOT EXTEND
BEYOND THE LIMITS OF THE ACTUAL BUILDING AND THE APPURTENANCES.
BUILDING EXPANSION
ESTABLISH THE FINAL SUBGRADE ELEVATION TO ALLOW FOR THE CONCRETE SLAB AND BASE. REFERENCE ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR REQUIRED
SLAB THICKNESS. THE MINIMUM 6 —INCH THICK 'BUILDING SLAB BASE MATERIAL" SHALL CONFORM SPECIFICATION SECTION 02300. IF THE 1UILDING SLAB BASE
MATERIAL" BECOMES SEGREGATED DURING SPREADING, THE AFFECTED AREAS OF GRAVEL SHALL BE KEYED WITH 'CHOKER MATERIAL' CONFORMING TO THE GRADATION
AND THICKNESS REQUIREMENTS PRESENTED IN SPECIFICATION SECTION 02300. INSTALL A 10 —MIL THICK VAPOR RETARDER, MEETING ASTM E1745, CLASS A
REQUIREMENTS, PLACED ABOVE THE BASE AND DIRECTLY BELOW THE SLAB. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ACCURATE MEASUREMENTS FOR
ALL CUT AND FILL DEPTHS REQUIRED. ANY PROPOSED EQUIVALENT ALTERNATIVE BASE MATERIAL MUST BE SUBMITTED FOR APPROVAL WITHIN 30 DAYS AFTER AWARD
OF CONTRACT. ANY EQUIVALENT ALTERNATIVE SHALL ONLY BE USED IF APPROVED IN WRITING BY THE CEC AND AOR.
EXISTING FOUNDATIONS, SLABS, PAVEMENTS, AND BELOW GRADE STRUCTURES SHALL BE REMOVED FROM THE BUILDING AREA. UNDERGROUND UTILITIES WITHIN THE
PROPOSED BUILDING PAD SHALL BE COMPLETELY REMOVED AND THE RESULTING EXCAVA11ONS BACKFILLED PITH SATISFACTORY MATERIALS' PER SPECIFICATION SECTION
02300. REMOVE SURFACE VEGETATION, TOPSOIL, ROOT SYSTEMS, ORGANIC MATERIAL, EXISTING FILL, AND SOFT OR OTHERWISE 'UNSATISFACTORY MATERIAL' FROM THE
BUILDING AREA.
PROOFROLL EXPOSED SUBGRADE IN THE PRESENCE OF THE OWNER'S CTL. WHERE PROOFROWNG CANNOT BE SUCCESSFULLY COMPLETED DUE TO ACCESS UMITATIONS,
EFFORTS TO DETECT 'UNSATISFACTORY MATERIALS" SHALL BE ATTEMPTED IN ACCORDANCE WITH SPECIFICATION SECTION 02300. REMOVE AND REPLACE
UNSATISFACTORY MATERIALS" PITH SATISFACTORY MATERIALS" PER SPECIFICATION SECTION 02300 AND /OR STABILIZATION MATERIALS PER SECTION 02340.
SATISFACTORY MATERIAL SHALL BE PLACED PER SPECIFICATION SECTION 02300.
THE FOUNDATION SYSTEM SHALL BE AUGERCAST PILES AND GRADE BEAMS
EXISTING BUILDING
REMOVE THE EXISTING SLAB AS SHOWN ON THE PLANS. TRENCHES SHALL BE EXCAVATED IN ACCORDANCE WITH SPECIFICATION SECTION 02300 AND BE BACKALLED
WITH SATISFACTORY MATERIALS" PER SPECIFICATION SECTION 2300. WHERE EXCAVATIONS PENETRATE EXISTING FLOOR SLABS, THE CAPILLARY BREAK AND BASE
MATERIAL (IF PRESENT) THE TRENCH SIDEWALLS SHALL BE RETAINED SO AS TO NOT UNDERMINE THE SURROUNDING SLAB. PRESERVE AND PROTECT THE EXISTING
SLAB THAT REMAINS, AS WELL AS OTHER STRUCTURAL ELEMENTS, FROM DAMAGE DURING CONSTRUCTION. WHERE EXISTING BUILDING SLAB BASE MATERIAL IS REMOVED
IN TRENCH AREAS AND OTHER AREAS WHERE THE SLAB IS REMOVED, ESTABLISH THE FINAL SUBGRADE ELEVATION TO ALLOW FOR THE CONCRETE SLAB AND BUILDING
SLAB BASE MATERIAL. INSTALL A 10 -MIL THICK VAPOR RETARDER, MEETING ASTM E1745, CLASS A REQUIREMENTS, PLACED AT THE SAME ELEVATION AS THE EXISTING
VAPOR BARRIER, IF ONE IS PRESENT. THE EXISTING VAPOR BARRIER SHALL BE PRESERVED AND THE REPLACEMENT BARRIER OVERLAPPED WITH THE EXISTING BARRIER
TO PROVIDE A CONTINUOUS VAPOR BARRIER. REFERENCE ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR REQUIRED SLAB THICKNESS. IN UNDISTURBED SLAB BASE
AREAS, THE CONTRACTOR SHALL COMPACT THE EXISTING BUILDING SLAB BASE MATERIAL IN THE PRESENCE OF THE OWNER'S CTL IN ORDER FOR THE CTL TO OBSERVE
THE STABILITY OF THE SUBGRADE AND BUILDING SLAB BASE MATERIAL, THE CTL SHALL THEN DENSITY TEST THE BUILDING SLAB BASE MATERIAL TO CONFIRM THAT IT
MEETS THE COMPACTION SPECIFICATIONS IN SECTION 02300. NEW 'BUILDING SLAB BASE MATERIAL" SHALL BE A MINIMUM OF 6 INCHES THICK AND SHALL CONFORM TO
THE PRODUCT REQUIREMENTS PRESENTED IN SPECIFICATION SECTION 02300. IF THE 'BUILDING SLAB BASE MATERIAL' BECOMES SEGREGATED DURING SPREADING, THE
AFFECTED AREAS OF GRAVEL SHALL BE KEYED PITH 'CHOKER MATERIAL" CONFORMING TO THE GRADATION AND THICKNESS REQUIREMENTS PRESENTED IN SPECIFICATION
SECTION 02300. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ACCURATE MEASUREMENTS FOR ALL CUT AND FILL DEPTHS REQUIRED. ANY PROPOSED
EQUIVALENT ALTERNATIVE 'BUILDING SLAB BASE MATERIAL" MUST BE SUBMITTED FOR APPROVAL WITHIN 30 DAYS AFTER AWARD OF CONTRACT. ANY EQUIVALENT
ALTERNATIVE SHALL ONLY BE USED IF APPROVED IN WRITING BY THE CEC AND AOR.
EXCAVATIONS SHALL NOT ENCROACH UPON THE BEARING SOIL OF EXISTING FOUNDATIONS. THE BEARING SOIL IS DEFINED AS THE PRISM OF SOIL BENEATH A LINE
THAT EXTENDS DOWN AND AWAY FROM THE BOTTOM EDGES OF A FOOTING AT 1'% HORIZONTAL TO i VERTICAL WHEN ENCROACHMENT CANNOT BE AVOIDED, THE
CONTRACTOR SHALL NOTIFY THE CONSTRUCTION MANAGER AND SHALL NOT PROCEED UNTIL FURTHER INSTRUCTION FROM THE CONSTRUCTION MANAGER.
SATISFACTORY MATERIAL SHALL BE PLACED PER SPECIFICATION SECTION 02300. PROOFROLL EXPOSED SUBGRADE IN THE PRESENCE OF THE OWNER'S CTL WHERE
PROOFROWNG CANNOT BE SUCCESSFULLY COMPLETED DUE TO ACCESS LIMITATIONS, EFFORTS TO DETECT UNSATISFACTORY MATERIALS' SHALL BE ATTEMPTED IN
ACCORDANCE WITH SPECIFICATION SECTION 02300.
THIS FOUNDATION SUBSURFACE PREPARATION DOES NOT CONSTITUTE A COMPLETE SITE WORK SPECIFICATION. IN CASE OF CONFLICT, INFORMATION COVERED IN THIS
PREPARATION SHALL TAKE PRECEDENCE OVER THE WAL -MART SPECIFICATIONS. REFER TO THE SPECIFICATIONS FOR SPECIFIC INFORMATION NOT COVERED IN THIS
PREPARATION. THIS INFORMATION WAS TAKEN FROM A GEOTECHNICAL REPORT PREPARED BY ZIPPER GEO ASSOCIATES, LLC, DATED 10/8/12. ( GEOTECHNICAL REPORT
IS FOR INFORMATION ONLY AND IS NOT A CONSTRUCTION SPECIFICATION).
to
=1 R- 313408
PIPE 7, FROM
STRUCTURE 7
CHAINUNK FENCE Fen
CHAINUNK FENCE o-au
GUIDE RAIL @
WAL —MART PARKING
1L
2
30 MIL IMPERMEABLE UNER
y
INSTALL
FILTER FABRIC PER WSDOT� 6" MIN. AMENDED SOIL
STD. SPEC 9- 33.2(1), 2" COMPOST TILLED INTO
TABLE 2 8' MIN. 6" NATIVE SOIL
110 LF 6" DIA. PERFORATED 5/8" MINUS CLEAN DRAIN
PIPE, 1% SLOPE ROCK.
VIEW B —B MIN 6" COVER OVER PIPE
I
MI � LY
16 N
1505 Westlake Ave. N. T (206) 522-9510 8 54875
o �IST81
Suite 305 F (206) 522 -8344 ONAL ��
Seattle, WA 98109 WWW.PAdMMON
CITY OF RENTON
Approved by. Dote
Approved by. Date
Approved by. Date
Approved by. Date
r
a
wo
V
AS NOTED
�.wlam°
wH martw
DATUM
N
O � y
m >
O
c
� o
'
x
a'
o m
SBB
z
(�
z
o Sm. MEB
RECORD DRAVANG
PACLAND
5_/9/14
orcaatt
JAC
F~
NO.
REVISION
BY
DATE
APPR
.InC
SPECIAL INSPECTIONS AND TESTING FOR SITE EXCAVATION AND GRADING
SPECIAL INSPECTIONS FOR BUILDING PAD PREPARATION AS REQUIRED BY SECTION 1704 OF THE
INTERNATIONAL BUILDING CODE AS AMENDED BY THE STATE OF WASHINGTON AND THE CITY OF
RENTON.
1. VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE ADEQUATE TO ACHIEVE THE DESIGN
BEARING CAPACITY
2. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHED PROPER MATERIAL
3. PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL MATERIALS.
4. VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFT THICKNESSES DURING PLACEMENT AND
COMPACTION OF COMPACTED FILL.
5. PRIOR TO PLACEMENT OF COMPACTED FILL, OBSERVE SUBGRADE AND VERIFY THAT SITE HAS BEEN
PREPARED PROPERLY.
VERIFICATION, OBSERVATION AND TESTING ACTIVITIES SHALL BE PER THE PRO ECT SPECIFICATIONS.
ENGINEERS CONSTRUCTION RECORD CERTIFICATION
THIS PLAN HAS BEEN REVIEWED FOR CONFORMANCE WITH THE DESIGN INTENT. THIS PLAN,
AS MODIFIED HEREIN, REPRESENTS THE RECORD CONDITIONS OF THE NEW CONSTRUCTION
SHOWN, BASED UPON INFORMATION PROVIDED BY CRABTREE SURVEYING. THIS DOCUMENT DOES
NOT REPRESENT A DETAILED FIELD SURVEY. THE ENGINEER HEREBY CERTIFIES THAT, BASED
UPON THE METHODOLOGY DESCRIBED ABOVE, CONSTRUCTION SHOWN IS CONSISTENT WITH THE
DESIGN INTENT EXCEPT AS NOTED, AND ACCURATELY REPRESENTS THE EXISTING CONDITIONS,
PER CONTRACTOR AND SURVEYOR PROVIDED RECORD INFORMATION.
3
AMCITY OF 11i�li��
RENTON STORRE#25516-05EXPANSION
GpMDM AD DpAMGE SECTIOM
Planning /Building /Public Works Dept. AND DETALS
AS BUILT