EROSION
1.
2.
3.
4.
5.
CONTROL NOTES
THESE NOTES SHALL APPEAR FOR PROJECTS - SITE IMPROVEMENTS, SURFACE
WATER UTILITY, WASTEWATER UTILITY, WATER UTILITY, AND TRANSPORTATION PLANS:
BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A
PRE - CONSTRUCTION MEETING MUST BE HELD WITH THE CITY OF RENTON,
PUBLIC WORKS DESIGN ENGINEER.
THE BOUNDARIES OF THE CLEARING LIMITS AND AREAS OF VEGETATION PRESERVATION
AS PRESCRIBED ON THE PLAN(S) SHALL BE CLEARLY FLAGGED BY SURVEY TAPE OR FENCING
IN THE FIELD PRIOR TO CONSTRUCTION IN ACCORDANCE WITH APPENDIX "D" OF THE SURFACE
WATER DESIGN MANUAL AND OBSERVED DURING CONSTRUCTION. DURING THE CONSTRUCTION
PERIOD, NO DISTURBANCE BEYOND THE CLEARING LIMTS SHALL BE PERMITTED. THE CLEARING
LIMITS SHALL BE MAINTAINED BY THE APPLICANT /ESC SUPERVISOR FOR THE DURATION OF CONSTRUCTION.
STABILIZED CONSTRUCTION ENTRANCES SHALL BE INSTALLED AT THE BEGINING OF CONSTRUCTION
AND MAINTAINED FOR THE DURATION OF THE PROJECT. ADDITIONAL MEASURES, SUCH AS
CONSTRUCTED WHEEL WASH SYSTEMS OR WASH PADS, MAY BE REQUIRED TO ENSURE THAT ALL
PAVED AREAS ARE KEPT CLEAN AND TRACK OUT TO ROAD RIGHT OF WAY DOES NOT OCCUR
FOR THE DURATION OF THE PROJECT.
ALL REQUIRED SEDIMENTATION /EROSION CONTROL FACILITIES MUST BE CONSTRUCTED AND IN
OPERATION PRIOR TO LAND CLEARING AND /OR CONSTRUCTION TO PREVENT TRANSPORTATION OF
(V
Y
5. FILTER FABRIC FENCES
SEDIMENT TO SURFACE WATER, DRAINAGE SYSTEMS AND ADJACENT PROPERTIES. ALL EROSION
PROVIDE 3/4" -
1.5"
AND SEDIMENT FACILITIES SHALL BE MAINTAINED IN A SATISFACTORY CONDITION UNTIL SUCH TIME
12"
SERVED THEIR USEFUL
THAT CLEARING AND /OR CONSTRUCTION IS COMPLETE AND POTENTIAL FOR ON -SITE EROSION HAS
WASHED GRAVEL
BACKTH
PASSED. THE IMPLEMENTATION, MAINTENANCE, REPLACEMENT AND ADDITIONS TO EROSION/
X
UPSLOPE AREA HAS BEEN
SEDIMENTATION CONTROL SYSTEMS SHALL BE THE RESPONSIBILITY OF THE PERMIT-FEE.
Z
6.
THE EROSION AND SEDIMENTATION CONTROL SYSTEMS DEPICTED ON THIS DRAWING ARE
0
INTENDED TO BE MINIMUM REQUIREMENTS TO MEET ANTICIPATED SITE CONDITIONS. AS
(n
CONSTRUCTION PROGRESSES AND UNEXPECTED OR SEASONAL CONITIONS DICTATE, THE PERMITEE
J
SHALL BE INSPECTED IMMEDIATELY
SHALL ANTICIPATE THAT MORE EROSION AND SEDIMENTATION CONTROL FACILITIES WILL BE
j
NECESSARY TO INSURE COMPLETE SILTATION CONTROL ON THE PROPSED SITE. DURING THE
AFTER EACH RAINFALL
AND AT LEAST DAILY DURING
COURSE OF CONSTRUCTION, IT SHALL BE THE OBLIGATION AND RESPONSIBILITY OF THE PERMITEE
ots
TO ADDRESS ANY NEW CONDITIONS THAT MAY BE CREATED BY THE ACTIVITIES AND TO PROVIDE
Y
ADDITIONAL FACILITIES, OVER AND ABOVE MINIMUM REQUIREMENTS, AS MAY BE NEEDED, TO
IMMEDIATELY.
PROTECT ADJACENT PROPERTIES AND WATER QUALITY OF THE RECIEVING DRAINAGE SYSTEM.
Cc
BARRIER
Q
7.
APPROVAL OF THIS PLAN IS FOR EROSION /SEDIMENTATION CONTROL ONLY. IT DOES NOT
a
FILTER FABRIC
CONSTITUTE AN APPROVAL OF STORM DRAINAGE DESIGN, SIZE NOR LOCATION OF PIPES, RESTRICTORS,
CHANNELS, OR RETENTION FACILITIES.
Z
O
8.
ANY AREAS OF EXPOSED SOILS, INCLUDING ROADWAY EMBANKMENTS, THAT WILL NOT BE
DISTURBED FOR TWO DAYS DURING THE WET SEASON (OCTOBER 1ST - MARCH 30TH) OR
(/)
SEVEN DAYS DURING THE DRY SEASON (APRIL 1ST - SEPTEMBER 30TH) SHALL BE
J
IMMEDIATELY STABILIZED WITH THE APPROVED ERC COVER METHODS (e.g. SEEDING,
>
MULCHING, PLASTIC COVERING, ETC.).
9.
WET SEASON SEASONAL EROSION AND SEDIMENT CONTROL REQUIREMENTS APPLY TO ALL
CONSTRUCTION SITES CLEARING BEWTEEN OCTOBER 1 AND MARCH 30 INCLUSIVE, UNLESS
OTHERWISE APPROVED BY THE CITY THROUGH AN ADJUSTMENT PROCESS.
10.
COVER MEASURES WILL BE APPLIED IN CONFORMANCE WITH APPENDIX "D" OF THE SURFACE
WATER DESIGN MANUAL.
11.
ANY AREA NEEDING ERC MEASURES, NOT REQUIRING IMMEDIATE ATTENTION, SHALL BE
ADDRESSED WITHIN SEVEN (7) DAYS.
12.
THE ERC FACILITIES ON INACTIVE SITES SHALL BE INSPECTED AND MAINTAINED A MINIMUM OF
ONCE A MONTH OR WITHIN 24 HOURS FOLLOWING A STORM EVENT.
13.
AT NO TIME SHALL MORE THAN ONE (1) FOOT OF SEDIMENT BE ALLOWED TO ACCUMULATE WITHIN
A CATCH BASIN. ALL CATCH BASINS AND CONVEYANCE LINES SHALL BE CLEANED PRIOR TO PAVING.
THE CLEANING OPERATION SHALL NOT FLUSH SEDIMENT -LADEN WATER INTO THE DOWNSTREAM SYSTEM.
14.
DURING THE TIME PERIOD OF OCTOBER 1ST - MARCH 30TH, ALL PROJECT DISTURBED SOIL AREAS,
THAT ARE TO BE LEFT UN- WORKED FOR MORE THAN 12 HOURS, SHALL BE COVERED
BY MULCH, SODDING, OR PLASTIC COVERING.
FILTER FABRIC MATERIAL 60" WIDE ROLLS.
USE STAPLES OR WIRE RINGS TO ATTACH
FABRIC TO WIRE.
2" BY 2" 14 GA. WIRE
FABRIC OR EQUIV.
II I
2' -6" I I I
II I
5' -0" JIB BURY BOTTOM OF FABRIC
_41-_________Ak MATERIAL IN 8" BY 12" TRENCH
I F 6 MAX --�
u u
15. ANY PERMANENT RETENTION /DETENTION FACILITY USED AS A TEMPORARY SETTLING BASIN SHALL
BE MODIFIED WITH THE NECESSARY EROSION CONTROL MEASURES AND SHALL PROVIDE ADEQUATE
STORAGE CAPACITY. IF THE PERMANENT FACILITY IS TO FUNCTION ULTIMATELY AS AN INFILTRATION
SYSTEM, THE TEMPORARY FACILITY MUST BE ROUGH GRADED SO THAT THE BOTTOM AND SIDES
ARE AT LEAST THREE FEET ABOVE THE FINAL GRADE OF THE PERMANENT FACILITY.
16. PRIOR TO THE BEGINNING OF THE WET SEASON (OCT. 1), ALL DISTURBED AREAS SHALL BE
REVIEWED TO IDENTIFY WHICH ONES CAN BE SEEDED IN PREPARATION FOR THE WINTER RAINS.
DISTURBED AREAS SHALL BE SEEDED WITHIN ONE WEEK OF THE BEGINNING OF THE WET SEASON.
A SKETCH MAP OF THOSE AREAS TO BE SEEDED AND THOSE AREAS TO REMAIN UNCOVERED
SHALL BE SUBMITTED TO THE CITY OF RENTON FOR REVIEW.
NOTES.
1. FOR SHEET RUNOFF OR FOLLOWING DISCHARGE FROM A
SEDIMENT TRAP OR POND.
2. MAXIMUM SLOPE STEEPNESS PERPENDICULAR TO FENCE
LINE IS 1:1.
3. MAXIMUM SHEET OR OVERLAND FLOW PATH LENGTH TO
THE FENCE OF 100 FT.
RISER PIPE
(PRINCIPAL SPILLWAY)
OPEN AT TOP WITH
TRASH RACK
PER FIG. 4.4.4\
SPILLWAY ' MIN. WIDTH
DEWATERING DEVICE
4. IF 50% OR LESS OF THE SOIL, BY WEIGHT, IS FINE PARTICLES 'S: (SEE RISER DETAIL)
IT
6"
FILTER FABRIC MATERIAL SMALLER THAN THE U.S. STANDARD SIEVE NO. 200, THE EOS -II
SHOULD BE EQUAL TO OR SMALLER THAN THE SIEVE SIZE II
2" BY 2" BY 14 GA. WIRE THAT 85% OF THE SOIL CAN PASS THROUGH.
_I ---- - - - - -- - --
FABRIC OF EQUIV.
5. THE TRENCH SHALL BE BACKFILLED WITH 3/4" MINIMUM
2' -0' DIAMETER WASHED GRAVEL. IJ II =II =I I— —I IJ I- 11I -11
OFFE ENGINEERSPlo
13932 SOUTHEAST 159TH PLACE
RENTON, WASHINGTON 98058 Z
PHONE: 425-260-3412 PoF' C s oG\r
CONTACT: DARRELL OFFE, P.E. 'sldNtii �� " NO. REVISION BY DATE APPR
WIRE - BACKED SILT FENCE,'
STAKED HAYBALES WRAPPED
WITH FILTER FABRIC, OR
EQUIVALENT DIVIDER
D.L OFFE, P.E.
o
D.L. OFFS, P.E.
AT ML SGIEML SGIE
s rar arE ra,
Mxaimxxr
DEWATERING
ORIFICE
EMBANKMENT COMPACTED 95 %.
PERVIOUS MATERIALS SUCH AS
GRAVEL OR CLEAN SAND SHALL
NOT BE USED.
1 j DISCHARGE TO STABILIZED
CONCRETE BASE CONVEYANCE, OUTLET OR
(SEE RISER DETAIL) LEVEL SPREADER
TEMP. POND CONTROL
CITY OF
RENTON
DATUM
Planning /Building /Public Works Dept.
cD
R- 313504
RECOMMEN D F R APPROVAL
By Date, 01 I
BYI Date, •(2• I
Byl Date,
By, Date,
WILSON PARK & WILSON PARK 2
ROBERT WILSON
720 SOUTH 55th STREET
GRADING /EROSION DETAILS & NOTES
Ce
07/15/2013
I
�y
0
0
5. FILTER FABRIC FENCES
SHALL BE REMOVED WHEN THEY HAVE
PROVIDE 3/4" -
1.5"
12"
SERVED THEIR USEFUL
PURPOSE, BUT NOT BEFORE THE
WASHED GRAVEL
BACKTH
X
UPSLOPE AREA HAS BEEN
PERMANENTLY STABILIZED.
IN TRENCH AND
ON BOTH SIDES I
OF FILTER FENCE FABRIC ON —{
8" MIN.
6. FILTER FABRIC FENCES
SHALL BE INSPECTED IMMEDIATELY
THE SURFACE.
AFTER EACH RAINFALL
AND AT LEAST DAILY DURING
2" BY 4" WOOD POST
PROLONGED RAINFALL.
ANY REPAIRS SHALL BE MADE
ALT: STEEL FENCE POSTS.
IMMEDIATELY.
BRUSH
BARRIER
NTS 066
FILTER FABRIC
FENCE DETAIL
OFFE ENGINEERSPlo
13932 SOUTHEAST 159TH PLACE
RENTON, WASHINGTON 98058 Z
PHONE: 425-260-3412 PoF' C s oG\r
CONTACT: DARRELL OFFE, P.E. 'sldNtii �� " NO. REVISION BY DATE APPR
WIRE - BACKED SILT FENCE,'
STAKED HAYBALES WRAPPED
WITH FILTER FABRIC, OR
EQUIVALENT DIVIDER
D.L OFFE, P.E.
o
D.L. OFFS, P.E.
AT ML SGIEML SGIE
s rar arE ra,
Mxaimxxr
DEWATERING
ORIFICE
EMBANKMENT COMPACTED 95 %.
PERVIOUS MATERIALS SUCH AS
GRAVEL OR CLEAN SAND SHALL
NOT BE USED.
1 j DISCHARGE TO STABILIZED
CONCRETE BASE CONVEYANCE, OUTLET OR
(SEE RISER DETAIL) LEVEL SPREADER
TEMP. POND CONTROL
CITY OF
RENTON
DATUM
Planning /Building /Public Works Dept.
cD
R- 313504
RECOMMEN D F R APPROVAL
By Date, 01 I
BYI Date, •(2• I
Byl Date,
By, Date,
WILSON PARK & WILSON PARK 2
ROBERT WILSON
720 SOUTH 55th STREET
GRADING /EROSION DETAILS & NOTES
Ce
07/15/2013
I
�y
0
0
�o>
Nz
A
0
°z
X
W
N
I