Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
S-373501
N (O LO O O M N YM [L Z 0 J ots fr Q IL U) J ►a G SSMH #2, 54" EXTRA SHALLOW RIM =222.0 IE= 218.00, 8" (S) IE= 218.17, 6" NE) 15' SANITARY SEWER EASEMENT (PUBLIC) PORTION OF THE SE 1/4, SE 1/4 OF SECTION 31, TOWNSHIP 23 N, RANGE 5 EAST, W.M. STA. 14 +48.0 14.9' LT. SSMH 7, 48 0 RIM= 281.30 cv, o IE= 274.20, 8" OUT) iry pN O IE= 274.30, 8" IN) O o2- f �l oM I w 14� L 16+ 0 W� X O OO �zl IE= 252.53, 8 IE= 252.63, 8 I I I I N 1 I N 7.5' RD r I � MIN. BAS F, I / I I � • + Q� IE =21 I I MIN. I IN I ® 1 +f Iz j I I �I � I I I I I \ \I N I N 0' NOTE: ALL TRENCH RESTORATION SHALL BE PER CURRENT 1\ CITY OF RENTON STREET OVERLAY AND TRENCH RESTORATION DETAIL - -I_ I PROPERTY CORNER STA.6 +84.77, 30.0' LT. r STA. 6 +92.0 8.0 °+ - RT. \ SSMH —I- w N 1 RIM =214.0 _ _ �� — — IE= 205.97, 12 "(EX.) 12' PVC SEWS -12. _7 IE= 206.14, 8 "(N) — _ V r, N IS NC- SI WSE§R 40LF., 8" PVC SSOS =8.25% J OFFE ENGINEERS 13932 SOUTHEAST 159TH PLACE RENTON, WASHING-TON 98058 PHONE: 425 -260 -3412 CONTACT: DARRELL OFFE, P.E. ft Z 27� _ . NO. P1 1 1 T17 J\ CS 6 6, MIN. FIN. FLOOR =253.0 7'479, IE =249.0 , FLOOR =248.0 FLOOR =243.0 \ O N I I 4 �p N I � I I II ;. 9 I II L R =238.0 ST . 10 +78.54 6.0' LT. / "S H 4, 54 — SHALLOW / IM= 236.56 1 = 229.46, 8" OUT) / I = 229.56, 8" IN) 0 S ®S =8.25% I IN. F 0 R =232.0 / 0 1 E 80 1 6 6.0' LT. 3 Cc4SHALLOW 1 R 2 N 1__1 P C S W N (S- 229703) — EX. 3 —'�3 RIM = 2-31.44 N IE= 22LN.76, 12° E) IE= 222.64, 12" �W) IE= 222.76, 8" (N) N O V O W O 4. M V/` 37 1 a" ALL SIDE SEWER CLEANOUTS LOCATED WITHIN FUTURE DRIVEWAYS SHALL HAVE TRAFFIC BEARING FRAME AND LID RI M= 317.50 IE= 310.50, 8" ALL SANITARY SIDE SEWER STUBS SHALL BE PVC PLACED AT MINIMUM SLOPE= 2.00 %, TYPICAL. STANDARD 48" SANITARY SHALLOW SANITARY SEWER SEWER MANHOLES PER MANHOLES PER STANDARD STANDARD PLAN #400.1 PLAN #400.2 IE= 318.44, 8" 7) D 3 RIM = 313.02 IE= 306.02, 8" OUT) IE= 306.12, 8" IN) I I 35 I 5- 313501 GRAPHIC SCALE 0 15 30 60 1 Inch = 30 feel RECOMMENDED FOR APPROVAL Bye tw Dnte 7 By�C^�h�/�vffGi�mate� By. Date WILSON PARK & WILSON PARK 2 ROBERT WILSON 720 SOUTH 55th STREET SANITARY SEWER PLAN CT�)'• S- - 3�-73 ( Er- 10/10/2013 © © ©DG r °z CRAMER NW SCALE DATUM da ,� CITY OF •� RENTON Planning /Building /Public Works Dept. D.L OFFE, P.E. r N o � w a N W D.L OFFE, P.E. ai¢•cx •lmm F XOI CfE BKH 10L°mOO''' REVISION BY IE= 318.44, 8" 7) D 3 RIM = 313.02 IE= 306.02, 8" OUT) IE= 306.12, 8" IN) I I 35 I 5- 313501 GRAPHIC SCALE 0 15 30 60 1 Inch = 30 feel RECOMMENDED FOR APPROVAL Bye tw Dnte 7 By�C^�h�/�vffGi�mate� By. Date WILSON PARK & WILSON PARK 2 ROBERT WILSON 720 SOUTH 55th STREET SANITARY SEWER PLAN CT�)'• S- - 3�-73 ( Er- 10/10/2013 © © ©DG r °z '> a N �Ue N ols ^ r N o � w a N W V