Loading...
HomeMy WebLinkAboutR-3614744;N *F1 EXISTING NEW DESCRIPTION STATION m TYPE III SIGNAL POLE WITH DECORATIVE 2" LUMINAIRE TYPE ROADWAY LUMINAIRE AND MAST ARM MOUNTING HEIGHT BASE DECORATIVE ROADWAY LUMINAIRE AND Q > =o 3 POLE (TYPE 1) COMMENTS WITH FLEXIBLE FABRIC INNERDUCT; USE EXISTING COILED FIBER OPTIC CABLE. DECORATIVE ROADWAY LUMINAIRE AND 7893N GARDEN POLE (TYPE 11) N, 4 MAST ARM MOUNTED SIGN 28.7' RT SIGNAL BRIDGE WITH COBRAHEAD LED, 4K ROADWAY LUMINAIRES 6' 25' LUMINAIRE ® m SIGNAL CONTROLLER CABINET ® ® ELECTRICAL SERVICE CABINET 26 FBP—Sl BACKUP POWER SUPPLY (BPS) CABINET ® B ID z 0 Ol JUNCTION BOX TYPE 1, 2, 8 - -- - - -- CONDUIT RT A WIRE NOTE 4K O CONSTRUCTION NOTE GENERAL NOTES 1. ALL WORK SHALL BE DONE WITH WSDOT STANDARD PLANS & SPECIFICATIONS AND THE LATEST AMENDMENTS, APWA STANDARDS, THE CITY DEVELOPMENTAL GUIDELINES AND THESE PLANS. 2. UTILITY LOCATION (DIAL -A -DIG) PRIOR TO CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. CONFLICTS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION. 3. CONTRACTOR SHALL COORDINATE WITH POWER COMPANY REGARDING THE ELECTRICAL SERVICE CONNECTION. CONTRACTOR SHALL MEET WITH PSE REPRESENTATIVE SHERI CLARKE AT (425) 456 -2701 PRIOR TO INSTALLATION OF METER BASE. 4. THE LOCATION OF ALL FEATURES TO BE INSTALLED BY THE CONTRACTOR SHALL BE VERIFIED IN FIELD BY THE ENGINEER PRIOR TO INSTALLATION. 5. ALL NEW JUNCTION BOXES INSTALLED IN SIDEWALKS SHALL HAVE SKID RESISTANT LIDS. 6. CONDUIT LOCATIONS ARE SHOWN FOR REFERENCE ONLY. FINAL LOCATIONS SHALL BE DETERMINED BY THE CONTRACTOR AND APPROVED BY THE ENGINEER IN THE FIELD. 7. NUMBER OF CONDUIT BENDS BETWEEN PULL POINTS SHALL NOT BE MORE THAN THE EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES TOTAL). IF NUMBER OF BENDS EXCEEDS 360 DEGREES, THE CONTRACTOR SHALL INSTALL ADDITIONAL JUNCTION BOXES, AS REQUIRED. 8. EXISTING OR HIGHER ILLUMINATION LEVELS SHALL BE MAINTAINED BY USING EXISTING OR TEMPORARY ILLUMINATION UN11L THE NEW SYSTEM IS OPERATIONAL THE CONTRACTOR IS ALSO RESPONSIBLE FOR MAINTAINING 10' CLEARANCE ZONE AROUND EXISTING AERIAL PRIMARY POWER LINES DURING THE CONSTRUCTION. COORDINATE WORK WITH THE POWER COMPANY REPRESENTATIVE. w iN 2 H c G w �( SD 0 off 40 +00 OH I Q} L® P 0 13 P P P EXIST R/W D D P SD p p N Ld ff c c G w N w w w w w,3 w w w o r ay!mr e '414-0`0' J r ..... .. 42 +00 °43 +00 44 n `p e I) SD 17 2 P z 9 - -- o ( )VI YK SD s 1 S 1 S 1 � g s 1 w SD SD - . r . cSDe D = a SC SD ------------------- - - - - -- - -- ------------------ - - - - -- GARDEN AVE N EXIST ESMT EXIST R/W PLAN 0 5 10 20 40 60 OLUMINAIRE SCHEDULE (ELECTRICAL SERVICE CABINET "St" - FOR CIRCUIT AND PANEL SCHEDULES SEE SHEET 23) LUMINAIRE # COR POLE ID # CONDUCTORS STATION m OFFSET 2" LUMINAIRE TYPE LUMINAIRE ARM MOUNTING HEIGHT BASE CIRCUIT # Q > =o 3 4" COMMENTS WITH FLEXIBLE FABRIC INNERDUCT; USE EXISTING COILED FIBER OPTIC CABLE. 1 7893N GARDEN AVE N, STA 40 +99 28.7' RT 70W, LED, 4K (LE3F) 240V 6' 25' FIXED 5 LUMINAIRE TYPE I PER DETAIL SHEET 26 2 7895N GARDEN AVE N, STA 41+39 28.7' RT 70W, LED, 4K (LE3F) 240V 6' 25' FIXED 5 LUMINAIRE TYPE I PER DETAIL SHEET 26 3 7897N GARDEN AVE N, STA 41 +89 28.7' RT 70W, LED, �e (LE3F) 240V 6' 25' FIXED e LUMINAIRE TYPE I PER DETAIL SHEET 26 4 7899N ,tee AVE N, STA 42 +35 28.7' RT n `p e I) SD 17 2 P z 9 - -- o ( )VI YK SD s 1 S 1 S 1 � g s 1 w SD SD - . r . cSDe D = a SC SD ------------------- - - - - -- - -- ------------------ - - - - -- GARDEN AVE N EXIST ESMT EXIST R/W PLAN 0 5 10 20 40 60 OLUMINAIRE SCHEDULE (ELECTRICAL SERVICE CABINET "St" - FOR CIRCUIT AND PANEL SCHEDULES SEE SHEET 23) LUMINAIRE # COR POLE ID # CONDUCTORS STATION m OFFSET 2" LUMINAIRE TYPE LUMINAIRE ARM MOUNTING HEIGHT BASE CIRCUIT # Q > =o 3 4" COMMENTS WITH FLEXIBLE FABRIC INNERDUCT; USE EXISTING COILED FIBER OPTIC CABLE. 1 7893N GARDEN AVE N, STA 40 +99 28.7' RT 70W, LED, 4K (LE3F) 240V 6' 25' FIXED 5 LUMINAIRE TYPE I PER DETAIL SHEET 26 2 7895N GARDEN AVE N, STA 41+39 28.7' RT 70W, LED, 4K (LE3F) 240V 6' 25' FIXED 5 LUMINAIRE TYPE I PER DETAIL SHEET 26 3 7897N GARDEN AVE N, STA 41 +89 28.7' RT 70W, LED, 4K (LE3F) 240V 6' 25' FIXED 5 LUMINAIRE TYPE I PER DETAIL SHEET 26 4 7899N GARDEN AVE N, STA 42 +35 28.7' RT 70W, LED, 4K (LE3F) 240V 6' 25' FIXED 5 LUMINAIRE TYPE I PER DETAIL SHEET 26 5 7901N GARDEN AVE N, STA 42 +91 28.7' RT 70W, LED, 4K (LE3F) 240V 6' 25' FIXED 5 LUMINAIRE TYPE I PER DETAIL SHEET 26 6 7903N GARDEN AVE N, STA 43 +41 28.7' RT 70W, LED, 4K (LE3F) 240V 6' 25' FIXED 5 LUMINAIRE TYPE I PER DETAIL SHEET 26 7 7905N GARDEN AVE N, STA 43 +97 28.7' RTj 70W, LED, 4K LE3F 240V 6' 1 25' FIXED 5 LUMINAIRE TYPE I PER DETAIL SHEET 26 GARDEN AVE N - LUMINAIRE REVISION LUMINAIRE STATION OFFSET EXIST. RD. PANEL CURB TOP FOUNDATION NO. SLOPE ELEV. ELEV. ELEV. (TC +2.7ft CONSTRUCTION NOTES O CONSTRUCT LUMINAIRE POLE FOUNDATION PER ILLUMINATION DETAILS, SHEET 26. FURNISH AND INSTALL DECORATIVE ROADWAY LUMINAIRE AND POLE (TYPE I) ARM, ANCHOR BOLT COVER, CONDUIT /WIRING, ALL ASSOCIATED EQUIPMENT AND APPLY DECAL NUMBERING WITH CDR POLE ID # TO LUMINAIRE POLES. FOR ADDITIONAL INSTALLATION DETAILS SEE ILLUMINATION SHEET 26, COR STANDARD DRAWINGS J007, J008, J009, J013 AND SPECIAL PROVISIONS. 0 EXISTING 11MBER POLE MOUNTED LUMINAIRE TO BE REMOVED BY OTHERS. COORDINATE REMOVAL WITH THE POWER COMPANY. ® EXISTING SIGNAL POLE MOUNTED LUMINAIRE TO REMAIN. MAINTAIN CIRCUIT CONTINUITY DURING CONSTRUCTION. O INSTALL R3 -8 (MOD) SIGN ON EXISTING SIGNAL MAST ARM AS DIRECTED BY THE ENGINEER. FOR SIGN DETAIL SEE CHANNELIZATION PLAN SHEET 33. 0 17 CONSTRUCT CURB WALL AROUND JUNCTION BOX PER DETAIL, SHEET 22. WIRE NOTES ®RACEWAY/ CONDUIT SIZE CONDUCTORS COMMENTS m 1 2" SPARE 2 2" 2 -#6 (ILL) Q > =o 3 4" 48CT -SMFO (EX INTC) WITH FLEXIBLE FABRIC INNERDUCT; USE EXISTING COILED FIBER OPTIC CABLE. 4 EX 2" 2 - #6 (EX ILL) z 5 4" SPARE; WITH FLEXIBLE FABRIC INNERDUCT NOTES: 1. ALL CONDUITS CONTAINING COPPER CONDUCTORS SHALL INCLUDE GROUND WIRE. GROUND WIRE SIZE SHALL MATCH THE LARGEST CONDUCTOR (MIN #8 AWG OR AS NOTED OTHERWISE IN THE WIRE NOTES). CONDUITS THAT DO NOT CONTAIN ELECTRICAL CONDUCTORS SHALL INCLUDE A DETACHABLE PULL TAPE. SPARE /EMPTY CONDUIT SHALL BE LABELED "CITY OF RENTON" AND SHALL CONTAIN DETECTABLE PULL TAPE. 2. ALL CONDUIT SHALL BE PVC SCH 40, EXCEPT UNDER ROADWAY USE PVC SCH 80 CONDUIT. R-361474 CALL 3 WORKING DAYS BEFORE YOU DIG: 811 i nuuuIuum W1, JU I U'y VL IG SURVEYED: KPG 1V' CIW AAr" DRRVEYED JC 46 - CITY OF RENTON SOUTH LAKE WASHINGTON DRAWING NO. 21 2 CID 9 - ADD JUNCTION BOX PROTECTION PAD 10 03 12 "o RECORD ,� h� DESIGN BY: JC Public Works Department ROADWAY IMPROVEMENTS PROJECT NO. 11156 75391hAveN 2502JefiersonAve REVISED TO CONFORM TO CONSTRUCTION RECORDS VS HJT 07 2014 I N S FED AID NO. CHECKev: HJT Seattle, WA 98109 Tam, Poi, a�9r?A�,a �wm 1� (20612861640 (2531627 -0720 PREPARED BY KPG, JULY 2014 APPROVED FOR CONSTRUCTION ILLUMINATION PLAN DATE: FEB 2012 ' M ENC'�? O PROJ MGR: NJD (2D5)�g Wm BASED ON CONSTRUCTION RECORDS STA 40 +00 TO STA 44 +00 NUMBER REVISION DESCRIPTION BY APP. DATE O FILE: 080461LL01.dwg BY DATE: SHEET NO. 21 OF 53 A'6 Qom' (�__7V I ti D c T >y m [_] C) ° = d �5z 0A Q > =o � 3 o Imo► 3 z