Loading...
HomeMy WebLinkAboutR-361477\ O \ ►W P P IOGgNgVF `~� ✓ rV p p H 4 11 � 10-� d OQ h 11 4 w \� /SO W 11 i \ t 0 0 LUMINAIRE SCHEDULE (EXISTING ELECTRICAL SERVICE CABINET LOCATED AT LOGAN AVE N, APPROXIMATE STA 10 +51, 82' RT) LUMINAIRE COR POLE STATION OFFSET LUMINAIRE TYPE LUMINAIRE MOUNTING BASE CIRCUIT COMMENTS # ID # o 3 4" ARM HEIGHT 4 # 2 - #6 (EX ILL) 15 7935N LOGAN AVE N, STA 13 +84 38.2' LT 105W, LED, 4K (LE3F) 240V 4' 35' FIXED EX LUMINAIRE TYPE II PER DETAIL SHEET 26 16 7937N LOGAN AVE N, STA 14 +57 38.2' LT 105W, LED, 4K LE3F 240V 4' 35' FIXED I EX LUMINAIRE TYPE II PER DETAIL SHEET 26 P � LOGAN AVE N TV a* A. Y P D a P 4 I 11 --- - -___- -- :� 11 13 15 16 12 +00 Q "' 13 +00 )Cv `s so 0 P EXISTING ELECTRICAL z Z q / SERVICE CABINET Q PLAN 4� c� / 0 5 10 20 40 60 LEGEND GENERAL NOTES EXISTING NEW DESCRIPTION 1. ALL WORK SHALL BE DONE WITH WSDOT STANDARD PLANS & TYPE III SIGNAL POLE WITH DECORATIVE SPECIFICATIONS AND THE LATEST AMENDMENTS, APWA STANDARDS, THE ROADWAY LUMINAIRE AND MAST ARM CITY DEVELOPMENTAL GUIDELINES AND THESE PLANS. DECORATIVE ROADWAY LUMINAIRE AND 2, UTILITY LOCATION (DIAL -A -DIG) PRIOR TO CONSTRUCTION SHALL BE THE POLE (TYPE 1) RESPONSIBILITY OF THE CONTRACTOR. CONFLICTS SHALL BE BROUGHT DECORATIVE ROADWAY LUMINAIRE AND TO THE ATTENTION OF THE ENGINEER FOR RESOLUTION. 990 POLE (TYPE II) 3. CONTRACTOR SHALL COORDINATE WITH POWER COMPANY REGARDING THE MAST ARM MOUNTED SIGN ELECTRICAL SERVICE CONNECTION. CONTRACTOR SHALL MEET WITH PSE SIGNAL BRIDGE WITH COBRAHEAD REPRESENTATIVE SHERI CLARKE AT (425) 456 -2701 PRIOR TO —_ INSTALLATION OF METER BASE. ROADWAY LUMINAIRES o LUMINAIRE 4• THE LOCATION OF ALL FEATURES TO BE INSTALLED BY THE CONTRACTOR SHALL BE VERIFIED IN FIELD BY THE ENGINEER PRIOR TO INSTALLATION. ® m SIGNAL CONTROLLER CABINET 5. ALL NEW JUNCTION BOXES INSTALLED IN SIDEWALKS SHALL HAVE SKID RESISTANT LIDS. ® can ELECTRICAL SERVICE CABINET 6. CONDUIT LOCATIONS ARE SHOWN FOR REFERENCE ONLY. FINAL -PS1 BACKUP POWER SUPPLY (BPS) CABINET LOCATIONS SHALL BE DETERMINED BY THE CONTRACTOR AND APPROVED BY THE ENGINEER IN THE FIELD. N z ID M L 0 JUNCTION BOX TYPE 1, 2, 8 7. NUMBER OF CONDUIT BENDS BETWEEN PULL POINTS SHALL NOT BE MORE CONDUIT THAN THE EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES TOTAL). Q IF NUMBER OF BENDS EXCEEDS 360 DEGREES, THE CONTRACTOR SHALL WIRE NOTE INSTALL ADDITIONAL JUNCTION BOXES, AS REQUIRED. O CONSTRUCTION NOTE 8. EXISTING OR HIGHER ILLUMINATION LEVELS SHALL BE MAINTAINED BY USING EXISTING OR TEMPORARY ILLUMINATION UNTIL THE NEW SYSTEM IS OPERATIONAL. THE CONTRACTOR IS ALSO RESPONSIBLE FOR MAINTAINING 10' CLEARANCE ZONE AROUND EXISTING AERIAL PRIMARY POWER LINES DURING THE CONSTRUCTION. COORDINATE WORK WITH THE POWER COMPANY REPRESENTATIVE. NUMBER REVISION DESCRIPTION BY I APP.I DATE �� C1GgN� 90 r3, °o ell Fk� 1� �S�ONAL D11 SURVEYED: KIPS DRAWN BY: JC DESIGN BY: JC CHECK BY: HJT PROJ MGR: NJD FILE: 080461LL01.dwg CONSTRUCTION NOTES EXIST R /W- — + I I I °. 11 sD so 11 13 w P P P O CONSTRUCT LUMINAIRE POLE FOUNDATION PER ILLUMINATION DETAILS, SHEET 26. FURNISH AND INSTALL DECORATIVE ROADWAY LUMINAIRE AND POLE (TYPE II) ARM, ANCHOR BOLT COVER, CONDUIT /WIRING, ALL ASSOCIATED EQUIPMENT AND APPLY DECAL NUMBERING TO LUMINAIRE POLES. FOR ADDITIONAL INSTALLATION DETAILS SEE ILLUMINATION SHEET 26, COR STANDARD DRAWINGS J007, J008, J009, J013 AND SPECIAL PROVISIONS. ® EXISTING SIGNAL POLE MOUNTED LUMINAIRE TO REMAIN. MAINTAIN CIRCUIT CONTINUITY DURING CONSTRUCTION. 11 EXISTING LUMINAIRE TO REMAIN. MAINTAIN CIRCUIT CONTINUITY DURING CONSTRUCTION. 13 ADD CONDUIT TO EXISTING JUNCTION BOX. SPLICE NEW LUMINAIRE WIRING TO EXISTING ILLUMINATION CIRCUIT. 15 LOCATION OF EXISTING JUNCTION BOX WITH EXISTING SPARE COILED FIBER OPTIC INTERCONNECT (48- SMFO). PULL EXISTING FIBER OPTIC CABLE TO NEW TRAFFIC CONTROLLER CABINET PER WIRE NOTES AND SIGNAL PLANS. ADJUST JUNCTION BOX TO NEW GRADE AND INSTALL CONCRETE BUMPOUT PER ROADWAY DETAILS SHEET 7. 16 EXISTING PRIVATE LUMINAIRE TO REMAIN. PROTECT EQUIPMENT AND MAINTAIN CIRCUIT CONTINUITY DURING CONSTRUCTION. IK1PGr 753 901 Ave N 2502 Jefferson Ave Seattle. WA98109 Tacoma, WA 96402 (206) 2861640 (253) 627 -0720 www.l(pg.com RECORD DRAWINGS PREPARED BY KPG, JULY 2014 BASED ON CONSTRUCTION RECORDS CITY OF RENTON Public Works Department APPROVED FOR CONSTRUCTION BY DATE: R- 361477 WIRE NOTES ®RACEWAY/ CONDUIT SIZE CONDUCTORS COMMENTS € 1 °. 11 sD so 11 13 w P P P O CONSTRUCT LUMINAIRE POLE FOUNDATION PER ILLUMINATION DETAILS, SHEET 26. FURNISH AND INSTALL DECORATIVE ROADWAY LUMINAIRE AND POLE (TYPE II) ARM, ANCHOR BOLT COVER, CONDUIT /WIRING, ALL ASSOCIATED EQUIPMENT AND APPLY DECAL NUMBERING TO LUMINAIRE POLES. FOR ADDITIONAL INSTALLATION DETAILS SEE ILLUMINATION SHEET 26, COR STANDARD DRAWINGS J007, J008, J009, J013 AND SPECIAL PROVISIONS. ® EXISTING SIGNAL POLE MOUNTED LUMINAIRE TO REMAIN. MAINTAIN CIRCUIT CONTINUITY DURING CONSTRUCTION. 11 EXISTING LUMINAIRE TO REMAIN. MAINTAIN CIRCUIT CONTINUITY DURING CONSTRUCTION. 13 ADD CONDUIT TO EXISTING JUNCTION BOX. SPLICE NEW LUMINAIRE WIRING TO EXISTING ILLUMINATION CIRCUIT. 15 LOCATION OF EXISTING JUNCTION BOX WITH EXISTING SPARE COILED FIBER OPTIC INTERCONNECT (48- SMFO). PULL EXISTING FIBER OPTIC CABLE TO NEW TRAFFIC CONTROLLER CABINET PER WIRE NOTES AND SIGNAL PLANS. ADJUST JUNCTION BOX TO NEW GRADE AND INSTALL CONCRETE BUMPOUT PER ROADWAY DETAILS SHEET 7. 16 EXISTING PRIVATE LUMINAIRE TO REMAIN. PROTECT EQUIPMENT AND MAINTAIN CIRCUIT CONTINUITY DURING CONSTRUCTION. IK1PGr 753 901 Ave N 2502 Jefferson Ave Seattle. WA98109 Tacoma, WA 96402 (206) 2861640 (253) 627 -0720 www.l(pg.com RECORD DRAWINGS PREPARED BY KPG, JULY 2014 BASED ON CONSTRUCTION RECORDS CITY OF RENTON Public Works Department APPROVED FOR CONSTRUCTION BY DATE: R- 361477 WIRE NOTES ®RACEWAY/ CONDUIT SIZE CONDUCTORS COMMENTS € 1 2" 3 SPARE 2 2" 2 -#6 (ILL) o 3 4" 48CT -SMFO (EX INTC) WITH FLEXIBLE FABRIC INNERDUCT; USE EXISTING COILED FIBER OPTIC CABLE. 4 EX 2" 2 - #6 (EX ILL) 5 4" Z SPARE; WITH FLEXIBLE FABRIC INNERDUCT NOTES: 1. ALL CONDUITS CONTAINING COPPER CONDUCTORS SHALL INCLUDE GROUND WIRE. GROUND WIRE SIZE SHALL MATCH THE LARGEST CONDUCTOR (MIN #8 AWG OR AS NOTED OTHERWISE IN THE WIRE NOTES). CONDUITS THAT DO NOT CONTAIN ELECTRICAL CONDUCTORS SHALL INCLUDE A DETACHABLE PULL TAPE. SPARE /EMPTY CONDUIT SHALL BE LABELED "CITY OF RENTON" AND SHALL CONTAIN DETECTABLE PULL TAPE. 2. ALL CONDUIT SHALL BE PVC SCH 40, EXCEPT UNDER ROADWAY USE PVC SCH 80 CONDUIT. SOUTH LAKE WASHINGTON ROADWAY IMPROVEMENTS ILLUMINATION PLAN STA 10 +00 TO STA 15 +00 CfB, 2- 36, 47 7 CALL 3 WORKING DAYS BEFORE YOU DIG: 811 r� DRAWING NO. 24 PROJECT NO. 11156 FED AID NO. DATE: FEB 2012 SHEET NO. 24 OF 53 I I I� B O 8 D 1M $ytl S D m N 9 Z E L G1 a C € am M Im M I I I I I 0 m d> 6 y an o € � � z Q -- �0 1 ° D O 0 I--+ 3 z I i 8 € 3 € a 3 W o D m m 05 Z I I I� B O 8 D 1M $ytl S D m N 9 Z E L G1 a C € am M Im M I I I I I 0 m d> 6 y an o € � � z Q -- �0 1 ° D O 0 I--+ 3 z I i 8 �o a o D R n y Z