HomeMy WebLinkAboutW-343018WEST GUTTER LINE 20 21 22 23 24 EAST GUTTER LINE GENERAL WATER CONSTRUCTION NOTES 1. EXISTING WATER MAINS, HYDRANTS, AND SERVICES SHALL REMAIN OPERATIONAL THROUGHOUT THE COURSE OF CONSTRUCTION EXCEPT WHERE WATER BYPASS SYSTEMS ARE REQUIRED. FOR INSTALLATION OF WATER BYPASS SYSTEMS SEE TEMPORARY WATER BYPASS PLANS, SHTS 160 -163. ABANDONMENT AND /OR REMOVAL OF EXISTING MAINS SHALL TAKE PLACE ONLY AFTER THE NEW MAIN OR WATER BYPASS SYSTEM HAS BEEN INSTALLED, TESTED, AND APPROVED BY THE CITY OF RENTON. 2. MAIN SHUTDOWNS SHALL BE BY CITY MAINTENANCE STAFF ONLY. CUT —IN CONNECTIONS TO EXISTING MAINS SHALL ALSO BE PERFORMED BY CITY STAFF. CONTRACTOR SHALL PROVIDE TWO WEEK ADVANCED NONCE TO CITY FOR SCHEDULE OF CONNECTIONS AND SHUTDOWNS. 3. EXISTING SERVICE LINES, METER SETTERS, AND METER BOXES ARE TO BE REPLACED AS PART OF THIS PROJECT. EXISTING METERS ARE TO BE RESET WITHIN THE NEW SETTERS COORDINATE W /CITY OF RENTON. 4. DEFLECT JOINTS AS NECESSARY TO INSTALL WATER MAIN WITH MINIMUM COVER ALONG THE APPROXIMATE LOCATION SHOWN. PIPE JOINTS NOT TO EXCEED 50 PERCENT OF THE MAXIMUM JOINT DEFLECTION SPECIFIED BY THE PIPE MANUFACTURER. 5. ABANDONED DUSTING WATER MAINS SHALL BE CAPPED WITH (MJ) CAPS. PORTIONS OF THE ABANDONED WATER MAIN MAY REQUIRE REMOVAL FOR THE CONSTRUCTION OF OTHER ROADWAY IMPROVEMENTS. 6. EXISTING FIRE HYDRANTS SHALL BE REMOVED AND PROPERLY DISPOSED OF BY THE CONTRACTOR AFTER INSTALLATION, TESTING, AND APPROVAL OF THE NEW HYDRANTS. 7. VERIFY LOCATION AND DEPTH OF EXISTING WATER MAINS AT ALL CONNECTION POINTS PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL FIELD VERIFY THE OUTSIDE DIAMETER (O.D.) OF ALL EXISTING CAST —IRON AND ASBESTOS — CEMENT PIPES, AND PROVIDE THE PROPER LONG —BODY ADAPTERS AND TRANSITION COUPLINGS FOR THE FINAL CONNECTIONS BY CITY FORCES. CONNECTIONS TO ALL DUCTILE IRON PIPES SHALL BE MADE NTH LONG SOLD SLEEVE COUPLINGS (MJ). B. ALL CONNECTIONS TO EXISTING WATER LINES SHALL BE MADE ONLY AFTER ALL THE NEW WATER LINES AND APPURTENANCES HAVE SUCCESSFULLY PASSED ALL PRESSURE TESTS, CLEANED WITH POLY —PIGS, DISINFECTED WITH CHLORINE SOLUTION, AND HAVE RECEIVED SATISFACTORY BACTERIOLOGICAL TEST LAB REPORTS, AND ARE THOROUGHLY FLUSHED. 9. ELEVATIONS OF EXISTING CROSSING UTILITIES ARE PARTIALLY BASED ON RECORD DRAWING INFORMATION. CONTRACTOR SHALL VERIFY LOCATIONS OF ALL UNDERGROUND EQUIPMENT PRIOR TO CONSTRUCTION AND INFORM THE ENGINEER IF CONFLICT IS FOUND. 10. ALL WATER MAINS, FITTINGS, AND APPURTENANCES SHALL BE INSTALLED PER CITY OF RENTON STANDARD DETAILS INCLUDED WITH PROJECT SPECIFICATIONS. 11. WATER PIPE AND FITTINGS INDICATED ON PLANS SHALL HAVE RESTRAINED JOINTS PER SPECIFICATIONS. SEE WATER PLANS, SHTS 132 -141 AND WATER PROFILES, SHTS 146 -159 FOR THESE LOCATIONS. 12. PROVIDE 10' HORIZONTAL SEPARATION FROM PARALLEL SEWER LINES WATER SHALL CROSS OVER EXISTING SEWER WITH 18" MINIMUM VERTICAL SEPARATION. WATER SHALL CROSS ALL OTHER UTILITIES WHH 12" MINIMUM VERTICAL SEPARATION. CONCRETE ENCASEMENT MAY BE NECESSARY WHERE THESE REQUIREMENTS CANNOT BE MET. 13. ALL WATER MAIN VERTICAL BENDS SHALL INCLUDE VERTICAL THRUST BLOCKING PER RENTON PLAN 330.3. ALL WATER MAIN HORIZONTAL BENDS SHALL INCLUDE HORIZONTAL THRUST BLOCKING PER RENTON PLAN 330.2. 0 5 10 20 40 60 HORIZONTAL SCALE IN FEET VERT. SCALE =1 2 HORIZ. SCALE SHEETS CATEGORY SHEET RIGHT OF WAY PLANS 10 EXISTING CONDITIONS 58 SITE PREPARATION & TESC PLAN 72 ALIGNMENT PLAN 94 ALIGNMENT PROFILE 96 DRAINAGE PLAN 107 DRAINAGE PROFILE 116,117 WATER PLAN 135 WATER PROFILE — JOINT UTIUTY TRENCH PLAN 167 JOINT UTIUTY TRENCH PROFILES 183 PROPERTY RESTORATION PLANS 196 CHANNEUZATION & SIGNING PLAN 220 ILLUMINATION PLANS 231 IRRIGATION PLAN 265 LANDSCAPE PLAN 297 nw[nuum RECORD DRAWINGS wu JLF I JAE I t ,i 3/2014 SURVEYED'. HPG DRAWN BY. SOD DESIGN BY SOD CHECK BY NJD PFOJ MGR'. JF FILE �UVATPNN1.M,p KpG 79BWA'mueN 75PtJMetmAKnue RECORD SoakwABBI4B TpYIq WA9BIfQ DRAWINGS MN�iMO ��� DRAWINGS kp;w 11 CITY OF RENTON .0 PUeu�wo,9s 0a9aamam APPROVED FOR CONSTRUCTION BY DATE. RAINIER AVENUE S (SR 167) S GRADY WAY TO S 2ND ST WATER PROFILE STA 20 +00 TO STA 24 +50 DRAWING NO. 149 PROJECT NO TEDaoaao FEDAID IJO. -0MD B) DATE, MAR 2014 SHEET NO 149 OF soa NUMBER REVISION DESCRIPTION BY APP. DATE