HomeMy WebLinkAboutW-358302c 13 s e 8 0 � D Z* z� ONE LINE DIAGRAM SYMBOLS PANELBOARDS, SWITCHES, AND EQUIPMENT LIGHTING FIXTURES /DEVICES ABBREVIATIONS LADDER LOGIC SYMBOL LEGEND �1 CIRCUIT BREAKER SERVICE ENTRANCE, SPDT - SINGLE POLE, DOUBLE THROW INDICATOR LIGHT RELAY INDICATOR LIGHT XXXIYY - CB SIZE & NO. OF POLES ET- ELECTRONIC TRIP SE T , MOTOR CONTROL O FLUORESCENT FIXTURE SPST - SINGLE POLE, SINGLE THROW DPST - DOUBLE POLE, SINGLE THROW RELAY A -AMBER G -GREEN TR - Timed relay 123 y SIGNED 0f/041Y3 CENTER, OR PANELBOARD ER, OR B - BLUE R -RED CR - Control relay TM- THERMAL MAGNETIC BREAKER MCP- MOTOR CIRCUIT PROTECTOR SURFACE MOUNTED WALUCEILING MOUNTED FIXTURE WP - WEATHER -PROOF GFI - GROUND FAULT INTERRUPT C - CLEAR W - WHITE MIL SE- SERVICE ENTRANCE PANELBOARD P -POWER FLOAT SWITCH ° GFI - GROUND FAULT INTERRUPTER C- CONTROL LIMITSWITCH �- FUSE FLUSHED MOUNTED EMERGENCY LIGHT WITH SELF J - INSTRUMENTATION PC -POWER &CONTROL O LIMIT SWITCH, NORMALLY OPEN O FLOAT SWITCH, NORMALLY OPEN as � FUSED DISCONNECT SWITCH ® CONTAINED BATTERY CJ - CONTROL & INSTRUMENTATION +`I°J" PANELBOARD PLUG-IN CONNECTION CKT. - CIRCUIT LIMIT SWITCH FLOAT SWITCH RTM RUN TIME METER NXX FIELD CONTROL STATION WITH NEMA SURFACE OR PENDANT MOUNTED O FIXTURE C.O. - CONDUIT ONLY O�0 LIMIT SWITCH, NORMALLY CLOSED Q 7 �� FLOAT SWITCH, J NORMALLY CLOSED SIGNED. Of/0�/as ❑ REQUIREMENTS. N.L. N.L. -NIGHT LIGHT v ® MOTOR OPERATION COUNTER Nt -NEMA 1 N3R- NEMA3R O RECESSED FIXTURE ALUMINUM CU.- COPPER TIME DELAY CONTACT PUSHBUTTON �T t� 1 SSRVS SSRVS -SOLID STATE N4 - NEMA 4 SS N4SS - NEM LA STEEL MD MOTION DETECTOR HOA HAND -OFF -AUTO SWITCH ETM RUN TIME METER TIME DELAY CONTACT, NORMALLY PUSHBUTTON, o OPEN, TIME TO CLOSE NORMALLY CLOSED J REDUCED VOLTAGE N4F -NEMA 4 FIBERGLASS 4 FIBERGLASS PC PHOTO CONTROL CELL O OC OPERATION COUNTER STARTER N8 - NEMA 6 Nit -NEMA 12 GASKETED MRIL MOTOR RUN INDICATION LIGHT SFIL SEAL FAIL INDICATION LIGHT TIME DELAY CONTACT PUSHBUTTON TIME DELAY CONTACT, NORMALLY PUSHBUTTON, NORMALLY OPEN v CLOSED, TIME TO OPEN SWITCH OUTLETS O O � VARIABLE FREQUENCY DRIVE —� EQUIPMENT MOUNTING STAND S ® STANDARD SWITCH, 20 AMP SFTR SEAL FAIL TRIP RESET OTIL OVER TEMPERATURE INDICATION LIGHT �1 m O v N I MOTOR STARTER ® 3 -WAY SWITCH,120VAC, 20 AMP 3 � 3WAY MOIL MOTOR OVERLOAD INDICATION LIGHT TIME DELAY CONTACT THERMOSTAT THERMOSTAT SWITCH, O TIME DELAY CONTACT, NORMALLY O NORMALLY OPEN 0_7 OPEN, TIME TO OPEN HEATER, WATTAGE NOTED INDICATE TYPE BY A B MOTOR STARTER WI OPERATOR CD S 3- POSITION SWITCH, 120VAC, 20 ®HOA AMP, LABEL SWITCH POSITION LETTER INSTRUMENT METER DEVICES A- HAND- OFF -AUTO ® EQUIPMENT CONNECTION HOA HAND -OFF- MOTION OR PHOTO —� A- AMMETER VAR- VARMETER AH - AMPERE -HOUR VARH - VARHOUR METER TIME DELAY CONTACT THERMOSTAT TIME DELAY CONTACT, NORMALLY THERMOSTAT SWITCH, �� M B - OPERATIONAL COUNTER PF - POWER FACTOR W - WATTMETER CLOSED, TIME TO CLOSE NORMALLY CLOSED S S C -RUN TIME METER D LIGHT SINGLE PHASE MOTOR, SINGLE -POLE DEE PILOT- LIGHTED P S V - VOLTMETER WH - WATTHOUR METER RELAY CONTACT, NC C N -RUN E - FAIL LIGHT HORSEPOWER AS NOTED S DOUBLE -POLE 2 KEY - OPERATED K VA- VOLTAMMETER FLOWSWITCH RELAY CONTACT, INSTANTANEOUS Li F - EMERGENCY STOP 100 THREE PHASE MOTOR. S THREE WAY 3 S LOW VOLTAGE Lv RACEWAY LEGEND RELAY CONTACT, NO CHANGE O FLOWSWITCH, NORMALLY OPEN I� c O KIRK KEY INTERLOCK HORSEPOWER AS S FOUR WAY S MASTER 5 rE PLlN LEGEND —1 � Z 0 W N� POWER TRANSFORMER NOTED S DIMMER ❑� PUSHBUTTON P PROPOSED POWER PRESSURE SWITCH M CONTROL POWER TRANSFORMER HP SINGLE PHASE MOTOR. HORSEPOWER AS D _ - -- PROPOSED CONTROL O FLOWSWITCH FLOWSWITCH, PRESSURE SWITCH, NORMALLY OPEN � NORMALLY CLOSED ~ O W W J FIRE SYSTEM SYMBOLS �A�A�AA GE ELLECTRICALPLUG 0 HEAT DETECTOR PROPOSED INSTRUMENTATION � J TRANSFORMER S SMOKE DETECTOR O o PROPOSED FIBER OPTICS PRESSURE SWITCH W :L 3 Q CURRENT TRANSFORMER DISCONNECT SWITCH OD FIRE ALARM DISPATCH STROBE ALARM DUILDIN6 0R FAGILfR PLAN L16END PRESSURE SWITCH, NORMALLY CLOSED 2 POLE SWITCH O a U 480 VOLT EXPOSED RACEWAY VOLTAGE TRANSFORMER Eh FUSED DISCONNECT SWITCH ❑A FIRE ALARM AUDIBLENISUAL ALARM _ 480 VOLT WIRING CONCEALED, [F] FIRE ALARM MANUAL PULL STATION UNDERGROUND, EMBEDDED, OR COMBINATION MOTOR CONCRETE ENCASED RACEWAY V z W T CONTACTOR STARTER AND DISCONNECT ADDITIONAL SYMBOLS W J SWITCH 1201208/240 VOLT EXPOSED RACEWAY W CAPACITOR OS SOUND SYSTEM SPEAKER _ _ _ _ _ 12012081240V WIRING CONCEALED, O 0 3 POLE SWITCH SOUND SYSTEM VOLUME CONTROL UNDERGROUND, EMBEDDED, OR CONCRETE ENCASED RACEWAY UJI ENGINE GENERATOR GENERATOR CONNECTION L K DOORBELL CONTROL OR INSTRUMENTATION EXPOSED �� W RECEPTACLE RACEWAY VALVE SYMBOLS CONTROL OR INSTRUMENTATION, RECEPTACLES AND JUNCTION BOX SYMBOLS SOLID NEUTRAL VNI PILOT VALVE SOLENOID UNDERGROUND, EMBEDDED, OR !� CEILING JUNCTION BOX CONCRETE ENCASED RACEWAY ® TERMINAL BLOCK WALL JUNCTION BOX 15/1 �/� VALVE HOME RUN TO PANELBOARD OR AS GENERAL NOTES SURGE PROTECTION DEVICE ❑J FLOOR JUNCTION BOX INDICATED 1. THIS IS A STANDARD LEGEND. NOT ALL OF THE INFORMATION SHOWN ON THIS PAGE E N G I N E E R S ll DUPLEX WALL RECEPTACLE I N I CHECK VALVE CONDUIT RUN, BROKEN AND CONTINUED WILL APPEAR IN THIS SET OF PLANS. PLANNER S SCIENTIST S SPD SURGE PROTECTION DEVICE 0 o ,120V WP = WEATHERPROOF SAME SHEET OR AS NOTED 2. THESE DRAWINGS ARE DIAGRAMMATIC ONLY; EXACT LOCATIONS OF ELECTRICAL (ALTERNATIVE) G= GROUNDED FLEXIBLE CONDUIT EQUIPMENT SHALL BE DETERMINED IN THE FIELD BY THE CONTRACTOR. THE RH2 ENGINEERING, INC. http: / /,ww.,h2,am IG = ISOLATED GROUND jl I o CONTROL VALVE l CONDUIT RUN. HATCH MARKS INDICATE INSTALLATION OF ALL EQUIPMENT SHOWN ON THESE DRAWINGS OR DESCRIBED IN THE mailboxe@rn2 com 1800.720.8052 GROUNDING SYSTEM SYMBOLS GF = GROUND FAULT INTERRUPTER NUMBER OF CONDUCTORS SPECIFICATIONS SHALL CONFORM TO THE REQUIREMENTS SET FORTH IN THE LATEST BELLINGHAM aso.�e.os3s 454 west Horton Road 1 GROUND EDITIONS OF ALL APPLICABLE CODES AND UTILITY COMPANY STANDARDS. CONTACT — DOUBLE DUPLEX ELECTRICAL SITE PLAN SYMBOLS CALLOUT INDICATING CONDUIT SIZE, OF THE UTILITY COMPANY REPRESENTATIVES AND VERIFY THEIR REQUIREMENTS. BOTHELL G .951.5 00 22722 29th Drive SE, Suite 210 �jj METAL PIPE GROUND LJ--LJ SINGLE RECEPTACLE, 120V UTILITY POLE AND GUY WIRE Yz' GRC, 2412 NUMBER AND SIZE WIRE. 3. NOTIFY THE ENGINEER IMMEDIATELY IF CONFLICTS IN EQUIPMENT LOCATIONS ARE EAST CONNECTION POINT, EXOTHERMIC SINGLE RECEPTACLE, 208V HH MANHOLE OR HANDHOLE CALLOUT INDICATING CONDUIT PER DISCOVERED OR IF PROBLEMS ARISE DUE TO FIELD CONDITIONS, LACK OF WENATCHEE D.... 300 Rei Street, Suite 5 WELD. CADWELD OR APPROVED XXX SCHEDULE INFORMATION OR ANY OTHER REASON. NO PAYMENT WILL BE MADE FOR CHANGES RICHLAND so5.°asslel EQUAL. ® DUPLEX FLOOR RECEPTACLE, 120V © BURIED POWER VAULT OR MANHOLE WHICH HAVE NOT BEEN FAVORABLY REVIEWED BY THE ENGINEER. 114 Commn:a Port Drn, Suite c GROUND ROD SIZED PER N.E.C. O SPECIAL PURPOSE WALL T TELEPHONE VAULT OR PEDESTAL CONDUIT BENT UP OR TOWARD SILVERDALE 360.e75.7seo 2021 Nw uny,e Rd. Suite 107 USE EXOTHERMIC WELD CONNECTION AT THE GROUND ROD. RECEPTACLE, RATING AS NOTED > CONDUIT BENT DOWN OR AWAY TACOMA 253 OS 3)2J° 621 Poem: Avmae Suite I04 PIGTAIL, BARE COPPER, LENGTH AS REQUIRED, V MINIMUM. CLOCK 0 FIBER OPTICS VAULT OR PEDESTAL LUMINAIRE 7 CAPPED CONDUIT W=358302 SCALE1XSHOWN ❑N TELEVISION 0 2" �— CONNECTION POINT, MECHANICAL, , TELEPHONE 1-1 PAD -MOUNT TRANSFORMER D F BAR IS NOT 2 SCALE IF BAR IS NOT 2" LONG COMPRESSION TYPE. raor: 1 oxc xo. E01 TELEPHONE/DATA WITH CABLE ROAD REVISED TO CONFORM DIDINiCCA TO CONSTRUCTION RECORDS rs°EM MLM %%%a� Y►7.'.C.(.�� %/ /�i�i� DAM Jan 4, 2013 S UT No. a¢xr: REN RH2 ENGINEERING INC. DATE MV 78 "No: 111 -016 ' —CCTF— D— E— LEGEND.DWG c 13 s e 8 0 � D Z* z�