HomeMy WebLinkAboutW-358304EXISTING FLUORIDATION EXISTING PORTABLE BUILDING SERVICE GENERATOR TRANSFORMER PROPOSED Uf NDERGROUND I GAS LINE r T -- P P F 1T - 0' I I, EXISTING CONCRETE SIDEWALK. r RESTORE TO EXISTING OR BETTER CONDITION AFTER INSTALLING CONDUIT EXISTING WELL 9 CMU BUILDING. SEE DWG NO. E07 FOR ELECTRICAL IMPROVEMENTS EXISTING FLUORIDATION CMU f BUILDING. SEE DWG NO. E04 FOR ELECTRICAL IMPROVEMENTSINTERSTATE405(1405) -- _ - - - -- - -_ _ _ EXISTING CONCRETE DRIVEWAY EXISTING TREES EXISTING OR BETTER CONDITION PROPOSED (DO NOT DISTURB) _ AFTER INSTALLING CONDUIT AND HANDHOLE (TYP) _ — _ — _ — — — pW 9 wE� LBL�G I PROPANE LINE SEE NOTE5 ._ —C4 P3 __ —_— ._ P —�— a\ P— C2 0 P P P P t CCTF BtDG - � q t I PROPOSED (2) 500 GALLON r-00 _ g; I LIQUID PROPANE TANKS FOR _ EMERGENCY GENERATOR PROPOSED PERIMETER FENCE TO MOUNTED TO CONCRETE. SEE DWG NO. E06 FOR DETAILS SURROUND PROPANE TANKS. SEE I "kin- _ = DWG NO. E06 FOR DETAILS L -�- - - - -'' PROPOSED BOLLARDS. SEE DWG NO. E06 FOR DETAILS NATIVE MATERIAL COMPACTED TO 95% PER ASTM D1557 OR AS REQUIRED PER PLAN 0 M z COVER OVER N HIGHEST CONDUIT —� IN TRENCH T RED ELECTRICAL WARNING TAPE CENTERED OVER EACH CONDUIT IN TRENCH (TYP) O O FINISH SURFACE PER PLAN D. 0 xg BE C y � Z Z � O x�n SAND BEDDING MATERIAL PER WSDOT SPECIFICATION 9.03 .13 MINIMUM DEPTH BELOW BOTTOM OF 3' ELECTRICAL CONDUIT NUMBER AND DEEPEST CONDUIT INSTALLED IN SIZE VARY AS PER SITE PLAN. MAINTAIN TRENCH 12" SPACING BETWEEN TELEMETRY CONDUITS AND OTHER CONDUITS. TYPICAL ELECTRICAL TRENCH DETAIL NOT TO SCALE NOTE: BURY DEPTH OF CONDUIT AND HORIZONTAL SPACING SHALL BE CONFIRMED WITH SERVING UTILITY BEFORE CONSTRUCTION. HMA CL. 112 ", COMPACTED PER STANDARD SPECIFICATIONS. DEPTH OF REPLACEMENT PATCH TO BE 1" THICKER THAN EXISTING, 3" MIN. DEPTH SAW CUT ACP, WHEEL CUT BST 1 EXISTING CCTF CMU BUILDING. SEE DWG NO. E07 FOR ELECTRICAL IMPROVEMENTS SITE PLAN 1 "= 20' -0" A PATCH TO EXTEND 12' BEYOND TRENCH CONSTRUCTION LIMITS EXISTING ASPHALT DRIVEWAY. RESTORE TO EXISTING OR BETTER CONDITION PER DETAIL THIS SHEET FUTURE DISINFECTION PIPING EXISTING PAVEMENT SUBBASE 6" MIN. CRUSHED SURFACING -- —` =' �—`—` TOP COURSE COMPACT TO 95% SEE TRENCH DETAIL FOR TRENCH CUT AND PATCH ALL MAX. DRY DENSITY (MDD), BACKFILL REQUIREMENTS. PAVEMENT DAMAGED MODIFIED PROCTOR. DURING CONSTRUCTION. TRENCH RESTORATION - PERMANENT PATCH NOT TO SCALE EXISTING LEGEND UTILITY SYMBOLS LINETYPES XXX N WATER VALVE CENTER ONES M HYDRANT PROPERTY ONES III WATER METER RIGHT -OF -WAY LINES 00 MANHOLES (SS /SD) LOT LINES ❑ CB DITCH UNE o POWER/UTILITY POLE FLOW UNE (i WY ANCHOR WATER UNE Q POWER TRANSFORMER SANITARY SEWER UNE FPT­Tl POWER /TELEPHONE VAULT STORM DRAIN UNE O POWER METER DRAIN UNE D TELEPHONE/TV RISER - CHEMICAL UNE M GAS VALVE - - ABANDONED LINE 99 GAS METER GAS UNE 0 MONITORING WELL UNDERGROUND POWER LINES [RV]@ WATER /CHEMICAL VAULT UNDERGROUND TELEMETRY UNES AN BURIED VALVE W/ VALVE BOX UNDERGROUND TELEPHONE ONES ®® VALVE IN VAULT UNDERGROUND CABLE N UNES SURFACE SYMBOLS OVERHEAD POWER LINES �ri STREET UGHIT - -- OVERHEAD UTIUTY LINES Gli LUMINAIRE CHAIN UNK FENCE a SIGN XXX = MAILBOX D 0 CsCC ROCKERY M 1�} CONIFEROUS TREE s D O DECIDUOUS TREE HATCHING L) BETTER CONDITION. n 3. RESTORE OPEN SPACE AND LAWN AREAS TO EXISTING PAVEMENT SURVEY SYMBOLS CONCRETE B FOUND CASED MONUMENT BUILDING ® S5/B' IRON REBAR W PC CAP 3K SET NAG NAIL/WASHER UNLESS OTHFFRRWWISE STATED. oar 5. PRIOR TO INSTALLING PROPOSED HANDHOLES, THE W- 358304 CONSTRUCTION NOTES XXX 1. SEE DWG NO. E02 FOR ELECTRICAL CONDUIT AND D 0 CONDUCTOR SCHEDULE. M 2. CONTRACTOR SHALL SAW CUT ALL WALKWAY AND s D DRIVEWAY CROSSINGS AND RETURN TO EXISTING OR L) BETTER CONDITION. n 3. RESTORE OPEN SPACE AND LAWN AREAS TO EXISTING � m OR BETTER CONDITION AFTER COMPLETION OF WORK. 4. PROPOSED TANKS, PAD AND FENCE ARE LOCATED ON w � NZ CONCRETE DRIVEWAY. CONTRACTOR SHALL COORDINATE WITH RENTON CITY PARKS DEPARTMENT FOR FINAL PLACEMENT. oar 5. PRIOR TO INSTALLING PROPOSED HANDHOLES, THE CONTRACTOR SHALL POTHOLE IN THE AREA TO LOCATE C1 EXACT LOCATION OF UNDERGROUND UTILITIES. DO NOT � INSTALL HANDHOLES ON TOP OF UNDERGROUND UTILITIES. SIGNED 011041YS SIGNED. 01104N ♦, \� / M O N Z Zv a ZLL ~ W OC co Li3 a 00 U it: aft U V W W 0 J cr W Uj x W R INEER SNNER S NTISTS RH2 ENGINEERING, INC. http: / / +,.,h2.com mailboxDH2. com 1.8CC 720.8052 BELLINGHAM aso.sos.OSes 454 West Horton Road BOTHELL ° meml.. 22722 29th Drive SE, Suite 210 EAST WENATCHEE iii.j sseoo 300 Simon Street. Suite 5 RICHLAND sasaass,e, 114 Columbia Point Drl,e, Suite C SILVERDALE a.Allas.7ss° 2021 NW IAhyre Rd. Suite 107 TACOMA 253272a°ss 621 Pacific Avenue Suite 104 SCALE: SHOWN ?22222999W P222291 1. REVISED TO CONFORM 0 DRAWING IS NOT TO SCALE 2" TO CONSTRUCTION RECORDS IF BAR IS NOT 2" LONG ale*: 1 OW NO RH2 ENGINEER a /i8 /rE EN�: CCA E03 ENGINEERING WE � INC. 1ciiIi nMLM 11" REVISED PER CONSTUCTION RECORDS N0. i REVISION D +h: Jan 4, 2013 SHIIJ N0' arNr REN T ffir GAD I MLM 1 6/18/14 .ae NO -: 111 -016 JF8 BY REVIEW1 DATE Rcxua, CCTF— D— E— SITEPLAN.DWG 7U- W -3' $301- C € i 2 In D 0 an N Z I � I I t 7 0 0 D 0 M z s D L) n � m I w � NZ oar 3 I t 7 0 0 3 z � L) n n � I oar 3 C1 � m —H / N W -sa 7 0 0 z �