Loading...
HomeMy WebLinkAboutR-365742m pPRCE 1g2305go8 ,_-- , f- r 242304g025 1 IRRIGATION SCHEDULE SYMBOL DESCRIPTION QTY PRECIP PSI GPM Approved by: SHRUB AREA FOR DRIP EMITTERS - MEDIUM DENSITY 12,392 S.F. 0.45 Wh 25 58 Approved by: ONE OR MORE DRIP EMITTERS PER PLANT, WITH DRIP Approved by: TUBING EITHER ABOVE OR BELOW GRADE. 90% OR LESS Approved by: FOLIAGE COVERAGE OF THE PLANTED AREA. SYMBOL 1w 1=i SYMBOL 0IP 1 ,Ri PROPE'RIV LINE _ MANUFACTURER/MODEUDESCRIPTION OTY RAIN BIRD XCZ-LF-100-PRF 7 LOW FLOW DRIP CONTROL KIT, 1" LOW FLOW VALVE, 3/4" PRESSURE REGULATING RBY FILTER, AND 30PSI PRESSURE REGULATOR. 0.2GPM-5GPM. RAIN BIRD ARV075 10 3/4" AIR RELIEF VALVE, MADE OF QUALITY RUST -PROOF MATERIALS, WITH A 6.0" DRIP VALVE BOX (SEB 7X8 EMITTER BOX). USE WITH INSTALLATION BELOW SOIL. THE VALVE WILL ALLOW AIR TO ESCAPE THE PIPELINE, THUS PREVENTING WATER HAMMER OR BLOCKAGE. RAIN BIRD PEB-PRS-D 1" 1 1", 1-1/2-,2- PLASTIC INDUSTRIAL VALVES. LOW FLOW CONLOETE `+PALL OPERATING CAPABILITY, GLOBE CONFIGURATION. WITH PRESSURE REGULATOR MODULE. UPPE PARKING BF FEBC08501^ 1 3 AR1 DOUBLE CHECK BACKFLOW PREVENTION, 112"TO 2" rrr LL rrr OI_ - C)© RAIN BIRD ESPBLXME WITH (01) ESPLXMSM4 1 rrr' = IS Q.-% 12 STATION COMMERCIAL CONTROLLER. MOUNTED ON A PLASTIC WALL MOUNT. PROPERTY LINE WATER METER 1" 1 ti IRRIGATION LATERAL LINE: PVC SCHEDULE 40 AND CLASS 315 85.7 L.F. PVC SCHEDULE 40 TO 1-1/2", PVC CLASS 315 SDR 13.5 pR.ii la FOR PIPES 2" AND LARGER. ONLY LATERAL TRANSITION PIPE SIZES 1"AND ABOVE ARE INDICATED ON THE PLAN, WITH ALL OTHERS BEING 314" IN SIZE. vJ ---'"" IRRIGATION MAINLINE: PVC SCHEDULE 40 720.1 L.F. IRRIGATION NOTES: V 1. THE CONTRACTOR IS TO INSTALL AN AUTOMATIC IRRIGATION SYSTEM THAT WILL PROVIDE 100% COVERAGE FOR ALL LANDSCAPED AREAS. OI VC rr—rr II 2. REFER TO SPECIFICATIONS AND DETAILS FOR INSTALLATION INSTRUCTIONS. FTE = 24.0 _ r r r r 3. MEET ALL APPLICABLE LOCAL AND MUNICIPAL CODES FOR WORK Atm NECESSARY IN IRRIGATION SYSTEM INSTALLATION. Ab 4. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES, PERMITS, W _ AND USE/SALES TAXES APPLICABLE TO THIS PROJECT. r r r D ° rG -_ — —. l 6. VERIFY ALL SITE INFORMATION PRIOR TO CONSTRUCTION. NOTIFY CH ' 444 OWNERMNDSCAPE ARCHITECT OF ANY DISCREPANCIES FROM PREPARED IRRIGATION PLANS. 7. LOCATE ALL UNDERGROUND UTILITIES PRIOR TO BEGINNING OF WORK. CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO UNDERGROUND Y4': _ = 5 UTILITIES CAUSED BY INSTALLATION OF IRRIGATION SYSTEM. D1Ft ' z I '..-` .• r r _ r r ; rrr _ r (} „ y, LagC,w P4AN0 2U`-k 8. CONTRACTORISTOREFERTOANDCOORDINATEIRRIGATIONSYSTEM INSTALLATIONws VERIFY CcO LSI 5 (04805 BETWE NPIPING IAN LANDSCAPE MATERIAL, EDGING, ETC. TING LOCATIONS p PROEM 3340 9 LOCATION AND TAP NCOORDINATEON PLIWITH OWNER AND AS SCHEMATIC, ILL OTHER DISCIPLTRACTOR IS INES. 10. CONTRACTOR IS TO PROVIDE ALL NECESSARY PIPE, VALVES, ETC. DOWNSTREAM FROM POINT OF CONNECTION NOT INSTALLED BY OTHER DISCIPLINES. C _ 11. CONTRACTOR IS TO VERIFY AVAILABLE PRESSURE AND FLOW AT POINT OF CONNECTION PRIOR TO INSTALLATION OF IRRIGATION SYSTEM EQUIPMENT AND NOTIFY LANDSCAPE ARCHITECT WITH VERIFICATION FIGURES. FAILURE I 1 5340L.0 i'185 TO NOTIFY LANDSCAPE ARCHITECT WILL RESULT IN CONTRACTOR TAKING pARCE RESPONSIBILITY FOR ANY ALTERATIONS TO THE PLAN DUE TO VARIATIONS OF PRESSURE OR FLOW AT HIS/HER OWN RISK. 12. INSTALL MANUAL DRAIN VALVES AT ALL LOW _ POINTS TO ALLOW FOR SYSTEM WINTERIZATION. 13. CONTRACTOR TO COORDINATE INSTALLATION OF SLEEVING WITH BUILDING CONSTRUCTION AND INSTALLATION OF PAVING AND SIDEWALKS. ALL SLEEVING UNDER PAVED SURFACES SHOWN ON PLANS IS BY CONTRACTOR UNLESS OTHERWISE NOTED. ALL MAINLINES, LATERAL LINES, DRIP LINES AND CONTROL WIRES UNDER PAVED SURFACES ARE TO BE INSTALLED IN NORTH SLEEVING. INSTALL SLEEVING AS PER DETAIL AND SPECIFICATIONS. 14. ALL PIPING, PVC ELECTRICAL SLEEVES, ETC. UNDER PAVING SHALL BE INSTALLED PRIOR TO PAVING WORK. NO TEES, ELLS OR OTH R TURNS IN PIPING LL BE CATED UNDER PAVING SHOWN ONR=365742 SCHEDU EA 0 PPIPEO FORS A AN NONRESSUE EXCEPT LAERALFIE NE SPIPING INSTALLED UNDER PAVED AREAS. 15. CONTRACTOR IS TO PROVIDE ELECTRICAL POWER TO THE AUTOMATIC CONTROLLER. COORDINATE LOCATION WITH OWNER/LANDSCAPE ARCHITECT. 16. CONTRACTOR SHALL EXTEND SPARE CONTROL WIRES FROM EACH CONTROLLER TO THE END OF THE MAINLINE SERVING THAT CONTROLLER. It - SEE DETAILS AND SPECIFICATIONS FOR NUMBER OF SPARE WIRES AND INSTALLATION REQ tR TATE OF WASHINGTONREGISTERED LANDSCAPE ARCHITECT R. M M LICENSE NO. 1035 EXP5iE5 ON MB12014 w 01.16.13 an 11477 Cm RF L 17. CITY OF RENTON Approved by: Date: Approved by: Date: Approved by: Date: Approved by: Date: ALL TRENCHES TO BE PUDDLED AND COMPACTED TO THE SAME DENSITY PLAN INSTALLATION REQ tR TATE OF WASHINGTONREGISTERED LANDSCAPE ARCHITECT R. M M LICENSE NO. 1035 EXP5iE5 ON MB12014 w 01.16.13 an 11477 Cm RF L 17. INSTALL ALL MATERIALS AND EQUIPMENT AS SHOWN IN DETAILS. USE SCHEMATIC TEFLON TAPE OR TEFLON PIPE DOPE ON ALL MALE PIPE THREADS ON ALL IRRIGATION IRRIGATION SWING JOINT AND VALVE ASSEMBLIES. 18. ALL TRENCHES TO BE PUDDLED AND COMPACTED TO THE SAME DENSITY PLAN AS THE UNDISTURBED ADJACENT SOIL. 19. CONTRACTOR TO PERFORM IRRIGATION AUDIT FOR IRRIGATION ZONES AS PART OF FINAL IRRIGATION ACCEPTANCE. BCM 20. IT IS THE INTENT OF THIS DESIGN THAT ALL IRRIGATION EQUIPMENT BE INSTALLED IN LANDSCAPED AREAS AND WITHIN THE PROPERTY LIMITS. ANY EQUIPMENT SHOWN OUTSIDE OF T4ESE LIMITS IS SHOWN IN THAT LOCATION FOR GRAPHICAL CLARITY ONL' ALL VALVE BOXES SHALL BE INSTALLED A MINIMUM OF 2'1 FROM EDGE OF ANY PAVED SURFACES. AND A MINIMUM OF 3'-0" FROM THE CENTERLINE OF ANY DRAINAGE SWALES. L2.01 1 t