HomeMy WebLinkAboutS-362161N
w
a -
z
U)
w
w
Irw
3.0W
Z
Q
J
IL
W
0
Q
cc
W
LEGEND
0 U
0
SANITARY SEWER CLEANOUT
EXISTING
PROPOSED
ROADWAY
S
BIKE RACK
ROADWAY CENTERUNE
-
---------�
PROPERTY / LOT UNE
A
'P
RIGHT -OF -WAY
-.__.-......
4
BOUNDARY LINE
c+>
M
EASEMENT UNE
+
- - - - - -
BUILDING SETBACK LINE
---- -
-- - -- --
ROLLED CURB AND GUTTER
- -
- - -- - -- -
VERTICAL CURB AND GUTTER
4
1
CONTOUR (MINOR)
--`. •.---_....
-- 612 --
CONTOUR (MAJOR)
coo
--
FOOTING DRAIN FLOWPATH
+-
i+
SPOT ELEVATION
a
�Z�
TOP/TOE OF SLOPE
-j ----- ---�---- ---�--
-------�-
CONCRETE SIDEWALK
-C,
SOIL LOG
CONCRETE BLOCK WALL
®
POWER VAULT/MANHOLE
ROCKERY
_
SIGN
BARRICADE
I><
SIGNAL CONTROL BOX
BOLLARDS
..
SEPTIC DISTRIBUTION BOX
MAILBOX
m
o
DOWNSPOUTS
o
O
STORY DRAMIAIX
CATCH BASIN TYPE 1 W/GRATE
;71
TRAFFIC PEDESTRIAN POLE
CATCH BASIN TYPE 1 W/SOUD UD
4'-
SEPTIC VENT
CATCH BASIN TYPE 2 W/GRATE
O
TRAFFIC SIGNAL POLE
CATCH BASIN TYPE 2 W/SOLID LID
@
STORM PIPE INLET/OUTLET
STORM DRAIN MANHOLE
OO C
TRAFFIC SIGNAL POLE W/UGHT
BEEHIVE MANHOLE
YARD DRAIN (ROUND LID)
n
YARD DRAIN
STORM DRAIN STUB MARKER POST
STORM DRAIN CLEAN-OUT
o `o
FIBER OPTIC MANHOLE
STORM DRAIN PIPE
o -
ROOF DRAIN
____.____..-...
SO SERVICE 6" CPEP WITH
_ c
ROOF DRAIN
INVERT O END OF PIPE
FIBER OPTIC STUB MARKER POST
�"`TI (:
SANITARY SEWER MANHOLE
0 U
0
SANITARY SEWER CLEANOUT
0 ods
O
SANITARY SEWER GRAVITY
S
BIKE RACK
SANITARY SEWER FORCE MAIN
FM
---------�
TRAFFIC.
STRAIGHT/RIGHT TURN ARROW
A
'P
STRAIGHT/RIGHT TURN ARROW
SEDIMENT FILTER
4
LEFT/RIGHT TURN ARROW
c+>
M
STRAIGHT/LEFT/RIGHT TURN ARROW
+
+
LEFT TURN ARROW
BOLLARD
RIGHT TURN ARROW
A
A
STRAIGHT ARROW
4
1
HANDICAP PARKING
&
111.
BIKE LANE
coo
MAILBOX
TRAFFIC SIGN
+-
i+
INFORMATION SIGN
-I
11"
STREET LIGHT
+
+
CONSTRUCTION SEQUENCE:
1. WITHIN EXISTING RIGHT-OF-WAY THE CONTRACTOR SHALL
COMPLETE THE INSTALLATION OF THE SANITARY SEWER LINES
WITHIN ONLY ONE ROADWAY BLOCK AT A TIME AND SHALL
COMPLETE THE TEMPORARY HOT -MIX ASPHALT RESTORATION OF
EACH ROADWAY BLOCK BEFORE BEGINNING WORK IN ANOTHER
BLOCK.
2. WITHIN EXISTING RIGHT-OF-WAY TEMPORARY RESTORATION OF
TRENCHES FOR OVERNIGHT USE SHALL BE ACCOMPLISHED BY
USING HOT -MIX ASPHALT (HMA). STEEL PLATES MAY BE USED
OVERNIGHT TO COVER THE LAST SECTION OF TRENCH. STEEL
PLATES MUST BE PINNED DOWN AND ASPHALT RAMPS/WEDGES
MUST BE PLACED AROUND THE PLATES. STEEL PLATES SHALL
NOT BE USED ON STEEP GRADES OR WHERE STEEL PLATES
PRESENT A ROADWAY HAZARD.
�lI WETLAND WITH BUFFER
\ v /
T.E.S.C.P.
WETLAND FLAG
— CLEARING LIMITS
FOUND MONUMENT IN
POWER POLE W/DROP UNE & LIGHT
—iE--3(—
r:
BIKE RACK
®OM
Y`r
POWER POLE W/DROP UNE, LIGHT & TRANSFORMER
--p---o-- N.G.P.E. FENCE
DELTA
DEBRIS PILE
®
SEDIMENT FILTER
POWER POLE W/DROP LINE & TRANSFORMER
STRAW BALE
c+>
FIRE PIT
L
RIP RAP PAD
POWER POLE W/LIGHT
CONSTRUCTION ENTRANCE
BOLLARD
POWER POLE W/LIGHT & TRANSFORMER
_
HORSE SHOE PR
4
POWER POLE
n
MAILBOX
POWER POLE W/TRANSFORMER
•,
MILE POST MARKER
O
PAD MOUNTED TRANSFORMER
-C,
SOIL LOG
®
POWER VAULT/MANHOLE
_
SIGN
I><
SIGNAL CONTROL BOX
:-
SEPTIC DISTRIBUTION BOX
m
SIGNAL JUNCTION BOX
SANITARY SEWER STUB MARKER POST
('J-
TRAFFIC PEDESTRIAN POLE
SEPTIC VENT
C}==-
TRAFFIC SIGNAL POLE
STORM PIPE INLET/OUTLET
O C —
TRAFFIC SIGNAL POLE W/UGHT
STORM DRAIN STUB MARKER POST
t,
FIBER OPTIC MANHOLE
ROOF DRAIN
FIBER OPTIC STUB MARKER POST
N!'.
CATCH BASIN
r(-
TELEPHONE GUY ANCHOR
CABLE TV MARKER POST
TELEPHONE ANCHOR POLE
t_I
CABLE TV RISER
LX'
JUNCTION BOX (UG)
ISI
SATELLITE DISH
O
TELEPHONE MANHOLE
LUMINAIRE W/ARM
f
TELEPHONE STUB MARKER POST
LUMINAIRE
O
TELEPHONE POLE
-<!
LANDSCAPE LIGHT
0
TELEPHONE RISER
-r?
YARD LIGHT (UNDER 10' TALL)
..
FIRE DEPT CONNECTION
'
GAS STUB MARKER POST
HOSE BIB
Q]
GAS VALVE
D
IRRIGATION CONTROL VALVE
o°O
OIL FILLER CAP
WATER MANHOLE
F<-
GUY ANCHOR
(!
WATER STUB MARKER POST
r -'T
GUY POLE
A490
MONITORING WELL
PIV
POWER GRATE
O
POST INDICATOR VALVE
Lf
ELECTRICAL JUNCTION PULL/BOX
SPRINKLER HEAD
ELECTRICAL STUB MARKER POST
G'
WATER VAULT
x
ELECTRICAL METER
WATER WELL
c
GAS
It>—
GUARD RAIL
OIL
OIL -
❑
FENCE, BOARD
a
POWER (BURIED)
><
FENCE, BARB -WIRE
- - v
- -
POWER (AERIAL)
O
FENCE, CHAIN-UNK
ro
FIBER OPTICS
*
FENCE, ELECTRIC
T
TELEPHONE (BURIED)
<>
FENCE HOG WIRE
- - T
- -
TELEPHONE (AERIAL)
=
FENCE, SPLIT RAIL
c
TV CABLE (BURIED)
X
FENCE, WIRE
- -
- -
TV CABLE (AERIAL)
o
FENCE WROUGHT IRON
CREEK OR STREAM CENTERLINE
RAILROAD TRACKS
�lI WETLAND WITH BUFFER
\ v /
WARNING: .�.... Su","asoa�
Sultue2m05 10 110ISI
os
Fetle,al Wey, WA 8800.3
THE UTILITY LOCATIONS SHOWN CPUNIC"°Www•esmcivil.com" (m
o-
F+Wom 1 Pr' °jM IM Wm.rM1 1 Im�4iU.w�W I°PicM,xive
ARE APPROXIMATE ONLY. DEPTH `""""
UNKNOWN. CALL 1-800-424-5555. ESM JOB #1352-006-007
3
5 1 ASBUILT
"ll
STREAM WITH BUFFER
19
T.E.S.C.P.
— —
— CLEARING LIMITS
FOUND MONUMENT IN
FILTER FABRIC FENCE
—iE--3(—
'
CUTOFF SWALE
®OM
INTERCEPTOR DITCH
DEFINED)
--p---o-- N.G.P.E. FENCE
DELTA
ROCK CHECK DAM
®
SEDIMENT FILTER
®
STRAW BALE
NON -RADIAL BEARING
GRAVEL CONE
L
RIP RAP PAD
CONSTRUCTION ENTRANCE
WARNING: .�.... Su","asoa�
Sultue2m05 10 110ISI
os
Fetle,al Wey, WA 8800.3
THE UTILITY LOCATIONS SHOWN CPUNIC"°Www•esmcivil.com" (m
o-
F+Wom 1 Pr' °jM IM Wm.rM1 1 Im�4iU.w�W I°PicM,xive
ARE APPROXIMATE ONLY. DEPTH `""""
UNKNOWN. CALL 1-800-424-5555. ESM JOB #1352-006-007
3
5 1 ASBUILT
"ll
STREAM WITH BUFFER
19
SURVEY
PROPOSED MONUMENT
IN CASE
®
FOUND MONUMENT IN
CASE
0oM
PROPOSED MONUMENT
(AS DEFINED)
®OM
FOUND MONUMENT (AS
DEFINED)
A
DELTA
BY DATE APPR
(R)
RADIAL BEARING < >
(NR)
NON -RADIAL BEARING
L
ARC LENGTH
REVISION
ABBREVIATIONS GENERAL NOTES:
1. ALL WORK MATERIAL SHALL BE IN CONFORMANCE WITH THE
AVE AVENUEID INSIDE DIAMETER LATEST STANDARDS AND SPECIFICATIONS OF THE CITY OF
RENTON PUBLIC WORKS DEPARTMENT AND THE 2008 EDITION OF
AC ASBESTOS CEMENT PIPE IE INVERT ELEVATION THE WSDOT/APWA STANDARDS AND SPECIFICATIONS, AS
APPROVED AND MODIFIED BY THE CITY OF RENTON IN THE
ADJ ADJACENT IN INCHES RENTON STANDARD PLANS & SPECIFICATIONS. SOME STANDARD
ALUM ALUMINUML LENGTH DETAIL DRAWINGS MAY HAVE BEEN MODIFIED FOR THE CONTRACT .
THE CONTRACTOR SHALL REFER TO DETAIL DRAWINGS INCLUDED
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE LB POUNDS IN THE CONTRACT DOCUMENTS. A SET OF APPROVED PLANS
SHALL BE KEPT ON SITE AT ALL TIMES DURING CONSTRUCTION.
AP ANGLE POINT LF LINEAL FEET
2. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE
ASPH ASPHALT MAX MAXIMUM AND R SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY
THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR
ASTM AMERICAN SOCIETY OF TESTING AND MATERIALS MFR MANUFACTURER DISTURBANCE. FOR UTILITY LOCATES CALL 800-424-5555 (OR
ASSY ASSEMBLY MH MANHOLE 811) A MINIMUM OF 72 HOURS PRIOR TO EXCAVATION.
BF BUND FLANGE MIN MINIMUM 3. AN APPROVED TRAFFIC CONTROL PLAN IS REQUIRED TO BE
SUBMITTED AT THE PRE -CONSTRUCTION MEETING. ANY
BLDG BUILDING MJ MECHANICAL JOINT MODIFICATIONS TO THE APPROVED TRAFFIC CONTROL PLAN SHALL
BLK BLOCK MISC MISCELLANEOUS BE RESUBMITTED AND APPROVED PRIOR TO IMPLEMENTATION.
BO BLOW OFF N NORTH 4. ALL FITTINGS SHALL BE BLOCKED PER CITY OF RENTON
BOW/BW BOTTOM OF WALL NO NUMBER STANDARD DETAILS UNLESS OTHERWISE NOTED.
5. THE CONTRACTOR SHALL USE A VACUUM STREET SWEEPER TO
BVC BEGIN VERTICAL CURVE NTS NOT TO SCALE REMOVE DUST AND DEBRIS FROM PAVEMENT AREA AS DIRECTED
BW BACK OF WALK OC ON CENTER BY THE ENGINEER. FLUSHING OF STREETS SHALL NOT BE
PERMITTED.
CTR CENTER OD OUTSIDE DIAMETER
6. BEFORE COMMENCEMENT OF TRENCHING, THE CONTRACTOR
CB CATCH BASIN OHW ORDINARY HIGH WATER SHALL PROVIDE A CATCH BASIN FILTER FOR ALL DOWNHILL
CI CAST IRONSTORM DRAIN INLETS AND CATCH BASINS. THE CONTRACTOR
PI POINT OF INTERSECTION SHALL PERIODICALLY INSPECT THE CONDITION OF ALL FILTERS
CL/q_ CENTERUNE PP POWER POLE AND REPLACE AS NECESSARY.
CLR CLEAR PVI POINT OF VERTICAL INTERSECTION 7. PAVEMENT MARKINGS (E.G. LANE LINE BUTTONS OR PAINT, STOP
CMP CORRUGATED METAL PIPEBARS, CROSSWALKS, ETC.) DAMAGED OR REMOVED DURING
PE POLYETHYLENE CONSTRUCTION SHALL BE REPLACED IN KIND.
CO CLEANOUT PERF PERFORATED
CONC CONCRETE PVC POLYVINYL CHLORIDE
C CONDUIT PVMT PAVEMENT
CONN CONNECTION PVT POINT OF VERTICAL TANGENCY
CONTR CONTRACTOR PC POINT OF CURVATURE
CONT CONTINUED PT POINT OF TANGENCY NOTE:
CY CUBIC YARDS QTY QUANTITY
1. LOT ONES ARE BASED ON GIS INFORMATION AND ARE FOR
CL CLASS RET RETAINING GENERAL INFORMATION ONLY.
CF CUBIC FEET RR RAILROAD 2. GRAVITY SANITARY SEWER PIPE MATERIAL
• PVC SDR35 - 4' TO 15' OF COVER
CFS CUBIC FEET PER SECOND
R RADIUS • PVC C900 - LESS THAN 4' OF COVER
DC DEGREE OF CURVATURE RED REDUCER PVC C900 - OVER 15' OF COVER
DI DUCTILE IRON REINF REINFORCED
DIA/0 DIAMETER REQ REQUIRED
DOT DEPARTMENT OF TRANSPORTATION R/W RIGHT OF WAY
DIM DIMENSION S SOUTH
DWGS DRAWINGS SCH SCHEDULE
D DRAIN SO STORM DRAIN
EDP EDGE OF PAVEMENT SF SQUARE FEET
E EAST SHT SHEET
ELEV ELEVATION SPECS SPECIFICATIONS
EL ELEVATION SQ SQUARE
ELEC ELECTRICAL SS SANITARY SEWER
EVC END VERTICAL CURVE STA STATION
EXIST EXISTING STD STANDARD
FDC FIRE DEPARTMENT CONNECTION TC TOP OF CURB
FG FINISH GRADE TEL TELEPHONE
FIG FIGURE THRD THREADED
FIN FINISHED THRU THROUGH
FL/rL FLOWLINE TOW/TW TOP OF WALL
FL FLANGE VE VERTICAL
S=362 161
TYPICAL
Ff �� VERT VERTICAL
FM FORCE MAIN W WEST
GA GAUGE - W/ WITH _
GALV GALVANIZED W/o WITHOUT AS -BUILT
GI GALVANIZED IRON WSS WATER SAMPLING STATION
GV GATE VALVE CHECKED FOR COMPUANCE TO CITY STANDARDS
Ea_
mCC
Ii15
DATUM
QIi
CITY OF
"u RENTON
Planning/Building/Public Works Dept.
ESM //10/1310/13
$T
ESM /19/13
ESM /24/14
°flA11Df1
I�
ESM 07/16/14
AN
I
IF �+o acs
�"""C°P0iX0L
BY DATE APPR
"�e�"
HERITAGE PLAT
SANITARY SEWER EXTENSION PHASE 2
LEGEND AND GENERAL NOTES
A-8- 5 -36 --if b/
Pxe
LG -01
0
mCC
$T
z