Loading...
HomeMy WebLinkAboutT-376302T W LUMINAIRES SCHEDULE LUMINAIRE NUMBER POLE* ID. NO. CIRCUIT NUMBER I CONDUIT/WIRE SCHEDULE CONSTRUCTION LOCATION °0 - m OFFSET (FEET) LED LAMP WATTAGE MAST ARM (FEET) MOUNTING HEIGHT (FT.) STANDARD PLAN 9 40 A N. 6TH ST. STA 594+67.69 N: 182,497.45 E: 1,300,197.15 24.8' RT 95/60 6'/4' 35'/14' 117.1 10 N A N. 6TH ST. STA 595+56.86 N: 182,490.30 E: 1,300,286.26 31.3' RT 95/60 6'/4' 35'/14' 117.1 11 A N. 6TH ST. STA 596+45.40 N: 182,477.89 E: 1,300,374.71 43.0' RT 95/60 6'/4' 35'/14' 117.1 12 A N. 6TH ST. STA 597+43.37 N: 182,477.08 E: 1,300,464.08 43.1' RT 95/60 6'/4' 35'/14' 117.1 13 A N. 6TH ST. STA 598+00.00 N: 182,479.13 E: 1,300,529.30 40.6' RT 95/60 6'/4' 35'/14' 117.1 14 A N. 6TH ST. STA 598+81.75 N: 182,481.66 E: 1,300,611.10 37.4' RT 95/60 6'/4' 35'/14' 117.1 * TO BE NUMBERED AT TIME OF CONSTRUCTION. NUMBERING TO BE PROVIDED PER CITY OF RENTON I CONDUIT/WIRE SCHEDULE CONSTRUCTION CIRCUIT TYPE °0 - m QUANTITY A 2" PVC.SCH NOTES � c I U INSTALL ARTERIAL STREET DECORATIVE ROADWAY LUMINAIRE FIXTURE AND POLE PER STANDARD PLAN 117.1, CONCRETE FOUNDATION, AND ASSOCIATED JUNCTION BOX PER DETAILS ON SHEET E-3, AND LUMINARIES SCHEDULE. INSTALL TYPE 1 JUNCTION BOX WITH CONCRETE PAD PER DETAIL IN STD. PLN. 120 ON SHEET E-3. REMOVE EXISTING HPS FIXTURE HEAD FROM EXISTING POLE, RETAIN EXISTING CIRCUIT FOR RECONNECTION TO NEW REPLACEMENT FIXTURE HEAD. ® PROVIDE NEW LED FIXTURE WITH BRACKET AND ARM AND ATTACH TO EXISTING 40' POLE AT SAME HEIGHT AS EXISTING FIXTURE. DEMOLISH EXISTING POLE AND FIXTURE, REMOVE CIRCUIT CONDUCTORS BACK TO THE NEAREST JUNCTION LOCATION. CUT, CAP AND ABANDON EXISTING CONDUITS IN PLACE. VERIFY AND MAINTAIN THE CONTINUITY OF THE EXISTING LIGHTING CIRCUIT. GENERAL NOTES 1. ALL PVC CONDUITS SHALL CONTAIN EQUIPMENT GROUNDING CONDUCTOR. ALL CONDUITS UNDER THE ROADWAY SHALL BE PVC SCHEDULE 80. 2. PROVIDE FOUNDATION FOR EACH LIGHT FIXTURE PER CITY OF RENTON STANDARD DETAIL 117.1. 3. ALL LUMINARIES SHALL HAVE FUSES LOCATED IN THE POLE BASE (SEE CITY OF RENTON STD. PLN. J013). 4. ALL SPLICES SHALL BE MADE IN JUNCTION BOXES (SEE CITY OF RENTON STD. PLN. J013). 5. SEE LUMINARIES SCHEDULE FOR STREET LIGHT POLE LOCATIONS. 6. ALL JUNCTION BOXES PER WSDOT STANDARD PLAN J-40.10-03. 7. PROVIDE NUMBERING ON EACH POLE PER CITY OF RENTON STANDARD PLAN 121 (SEE NOTE ON LUMINAIRES SCHEDULE FOR POLE ID NOs). 8. COORDINATE LIGHT POLE FOUNDATIONS WITH ALL UNDERGROUND UTILITIES. REFERENCE DRAWINGS E-2 E-3 LEGEND 4 POLE AND LUMINAIRE HH TYPE 1 JUNCTION BOX WITH CONCRETE PAD N2 FULL CUTOFF LED LIGHTING FIXTURE. QUANTITY 280 AND ORIENTATION OF FIXTURE AS SHOWN. FIXTURE MOUNTED AT 40' AFF. BEACON #VP-L-96NB280-4K-T4-480. 70+CRI TYPE IV DISTRIBUTION. L1 PROVIDE CONC. BASE, POLE, AND FULL CUTOFF 95 LED LIGHTING FIXTURES. BOTTOM OF LIGHTING FIXTURES MOUNTED AT 35' AND 14' AFF. DOMUS 55 SERIES 70+ CRI, #DMSS55-018-95W80LZD4K-ES-LZ3F-BKTX #DMSS55-018-6OW8OL7D4K-ES-LZ3F-BKTX IN COMPLIANCE WITH CITY OF RENTON STANDARDS BY: z.-4 Date: Aac BY: Date: BY: Date: BY: Date: C10 ai C12 C13 C14 C15 C16 C17 C18 C19 C20 C21 C22 C23 C24 C25 C26 C27 C28 C29 C30 KEY PLAN SME : NONE A 8 C D E F G H J K L I.HtSIIVtI A AA 4L 11 0 - -uGP BRUSH uca -; J zs m B m a' 1�SB9s LL 11 , z 1 \ 1 Ap�rovta�T+Co.y�/iY••ca w/CeR, .T rlw III: � 1 PLANA o E-1 SCALE: 1"=20' moo✓ 2D' D 2D' 4D' T=376302 �;,, 0 0 °NAL ` �D12 u ' r�- ao 559 I a SCALE IN FEET 11/14/2014 FEDAID: - sw.vrm. Nuc "oazw°.r iea"i�,ss, 10/15/14 S A Z A N AS SHOWN PEDESTRIAN PATHWAYS AND PARKING 0 omwwm: CALL 48 HOURS G R O U P `� Tel 206.267.1700 " JCR EZA/6® N. 6TH ST. IMPROVEMENTS m ` Fax 206.267.1701 JCR �F DATUM °R N N° BEFORE YOU DIG SAZAN# 339-1339 E-1 600 Stewart St., Ste 1400 SPT «� PARTIAL ELECTRICAL PLAN 1-800-424-5555 Seattle, Washington 98101 N0. REVISION BY DATE APPR P"APP OH Y 24 26 c 2 CONDUCTOR I DESIGNATION CONDUIT SIZE SIZE & CIRCUIT TYPE °0 - m QUANTITY A 2" PVC.SCH 2#8, #8 GND. � c 40 m I U INSTALL ARTERIAL STREET DECORATIVE ROADWAY LUMINAIRE FIXTURE AND POLE PER STANDARD PLAN 117.1, CONCRETE FOUNDATION, AND ASSOCIATED JUNCTION BOX PER DETAILS ON SHEET E-3, AND LUMINARIES SCHEDULE. INSTALL TYPE 1 JUNCTION BOX WITH CONCRETE PAD PER DETAIL IN STD. PLN. 120 ON SHEET E-3. REMOVE EXISTING HPS FIXTURE HEAD FROM EXISTING POLE, RETAIN EXISTING CIRCUIT FOR RECONNECTION TO NEW REPLACEMENT FIXTURE HEAD. ® PROVIDE NEW LED FIXTURE WITH BRACKET AND ARM AND ATTACH TO EXISTING 40' POLE AT SAME HEIGHT AS EXISTING FIXTURE. DEMOLISH EXISTING POLE AND FIXTURE, REMOVE CIRCUIT CONDUCTORS BACK TO THE NEAREST JUNCTION LOCATION. CUT, CAP AND ABANDON EXISTING CONDUITS IN PLACE. VERIFY AND MAINTAIN THE CONTINUITY OF THE EXISTING LIGHTING CIRCUIT. GENERAL NOTES 1. ALL PVC CONDUITS SHALL CONTAIN EQUIPMENT GROUNDING CONDUCTOR. ALL CONDUITS UNDER THE ROADWAY SHALL BE PVC SCHEDULE 80. 2. PROVIDE FOUNDATION FOR EACH LIGHT FIXTURE PER CITY OF RENTON STANDARD DETAIL 117.1. 3. ALL LUMINARIES SHALL HAVE FUSES LOCATED IN THE POLE BASE (SEE CITY OF RENTON STD. PLN. J013). 4. ALL SPLICES SHALL BE MADE IN JUNCTION BOXES (SEE CITY OF RENTON STD. PLN. J013). 5. SEE LUMINARIES SCHEDULE FOR STREET LIGHT POLE LOCATIONS. 6. ALL JUNCTION BOXES PER WSDOT STANDARD PLAN J-40.10-03. 7. PROVIDE NUMBERING ON EACH POLE PER CITY OF RENTON STANDARD PLAN 121 (SEE NOTE ON LUMINAIRES SCHEDULE FOR POLE ID NOs). 8. COORDINATE LIGHT POLE FOUNDATIONS WITH ALL UNDERGROUND UTILITIES. REFERENCE DRAWINGS E-2 E-3 LEGEND 4 POLE AND LUMINAIRE HH TYPE 1 JUNCTION BOX WITH CONCRETE PAD N2 FULL CUTOFF LED LIGHTING FIXTURE. QUANTITY 280 AND ORIENTATION OF FIXTURE AS SHOWN. FIXTURE MOUNTED AT 40' AFF. BEACON #VP-L-96NB280-4K-T4-480. 70+CRI TYPE IV DISTRIBUTION. L1 PROVIDE CONC. BASE, POLE, AND FULL CUTOFF 95 LED LIGHTING FIXTURES. BOTTOM OF LIGHTING FIXTURES MOUNTED AT 35' AND 14' AFF. DOMUS 55 SERIES 70+ CRI, #DMSS55-018-95W80LZD4K-ES-LZ3F-BKTX #DMSS55-018-6OW8OL7D4K-ES-LZ3F-BKTX IN COMPLIANCE WITH CITY OF RENTON STANDARDS BY: z.-4 Date: Aac BY: Date: BY: Date: BY: Date: C10 ai C12 C13 C14 C15 C16 C17 C18 C19 C20 C21 C22 C23 C24 C25 C26 C27 C28 C29 C30 KEY PLAN SME : NONE A 8 C D E F G H J K L I.HtSIIVtI A AA 4L 11 0 - -uGP BRUSH uca -; J zs m B m a' 1�SB9s LL 11 , z 1 \ 1 Ap�rovta�T+Co.y�/iY••ca w/CeR, .T rlw III: � 1 PLANA o E-1 SCALE: 1"=20' moo✓ 2D' D 2D' 4D' T=376302 �;,, 0 0 °NAL ` �D12 u ' r�- ao 559 I a SCALE IN FEET 11/14/2014 FEDAID: - sw.vrm. Nuc "oazw°.r iea"i�,ss, 10/15/14 S A Z A N AS SHOWN PEDESTRIAN PATHWAYS AND PARKING 0 omwwm: CALL 48 HOURS G R O U P `� Tel 206.267.1700 " JCR EZA/6® N. 6TH ST. IMPROVEMENTS m ` Fax 206.267.1701 JCR �F DATUM °R N N° BEFORE YOU DIG SAZAN# 339-1339 E-1 600 Stewart St., Ste 1400 SPT «� PARTIAL ELECTRICAL PLAN 1-800-424-5555 Seattle, Washington 98101 N0. REVISION BY DATE APPR P"APP OH Y 24 26 c 2 Z I v °0 - m mO p y D � c C m m G Z S = 3 I °0 no mO p y D � c C m G Z S = 3 �9 Z pi Y 3 C N �> a m m F m z y O G C VJ s c ;a a�<aT = 3 pi N �> a F N z C, � o 9 mo �m m D z Z