Loading...
HomeMy WebLinkAboutzR-3809SetT > G) T z Z 77 X z 77 -- l 0 c .. O z m m LLJ Z C) LJ '3 0 0� CL z Z • CO) V.- O CN O C%j LLI O 0 -i 0 Qf C m Q- (0) CL X LLJ 4) U) 0 z 0 C Q. C 0 c Q) W (D CL X LLI c 4) a_ LA. O mi 77 X 77 -- l 0 .. O O mi LJ <Z F- LJ _) U C' C_ T y O x O l C z l Z z z Z _z CC m Z T z m D D LJ <Z F- LJ _) U C' C_ T y O x O l � � Z z z Z _z CC T Z T z m D 2 CL N ch LO r O N O N W H Q H J a 3 v O J C Y m a 4) CL x w W s U) 0 z_ Q 0 0 0 O J C Y m a c O c 4) rY L CL x W N L cn c O U W W J l rTl x O ✓' OtJ x z T O x LLJ z U LLJ Of LL 2 CL N M 0 N O_ N W Q 0 0 J Of Y m a Q) CL X W t U) 0 Z 0 0 J rn Y m a c O C a� n� Q X W W C U W I W J � N U) 20 ,o o zo ao a' SCALE IN FEET 0 J 0 Z Y a z O z w w X w w z rL R EX ROAD SURFACE EX CONC C &G - 6' CW �- NEW LANDSCAPE NEW LANDSCAPE TYPICAL ROAD CROSS SECTION - SOUTHWEST 16TH STREET NTS CO3 LEGEND: O PAVEMENT DESIGNED FOR LIGHT LOADS L1 C09 D PAVEMENT DESIGNED FOR HEAVY LOADS LZ C09 EXISTING CONTOUR (NP) 22 PROPOSED CONTOUR (NP) EXISTING STORM DRAIN PIPE -- - EXISTING SANITARY SEWER PIPE - - - - -- TOP OF BERM - — — — — - BOTTOM OF BERM PARKING STALL COUNT TOTAL NEW PARKING STALLS NEW COMPACT STALLS % COMPACT STALLS 25 7 28% 18 CB = CATCH BASIN CONC = CONCRETE DEMO = DEMOLITION EX = EXISTING FF = FINISH FLOOR FG = FINISH GRADE IE = INVERT ELEVATION LF = LINEAL FEET SD = STORM DRAIN SDCO = STORM DRAIN CLEANOUT SSSCO = SANITARY SIDE SEWER CLEANOUT SSS = SANITARY SIDE SEWER TESC = TEMPORARY EROSION & SEDIMENTATION CONTROL TOC = TOP OF CURB TOEB = TOE OF BERM TOP = TOP OF PAVEMENT TOPB = TOP OF BERM TYP = TYPICAL v d1i N ? KEY NOTES KEY DESCRIPTION DETAIL/SHEET 1 REMOVE EX CB SEE SHEET C05 2 6" CEMENT CONC EXTRUDED CURB F /C07 3 6' CONC SIDEWALK I /C08 m TRANSITION SIDEWALK TO EXISTING DRIVEWAY OR 0 4 GRADE AT 1:12 MAX SLOPE - 10' WIDE, 2' TALL LANDSCAPE BERM (SEE Z 5 LANDSCAPE PLANS FOR DETAILS) - SAWCUT AND MATCH EG. APPLY TACK COAT AT 6 EDGE AND SURFACE SEALANT AT JOINT - SAWCUT EX ASPHALT 1' BACK FROM EX EDGE AND D 7 APPLY TACK COAT AT EDGE AND SURFACE - SEALANT AT JOINT 8 NEW CONC DRIVEWAY APRON, EXIT ONLY H /C08 9 REPLACE EX CONC CURB & GUTTER G /C07 J /C08 SEE LANDSCAPE PLANS FOR TREE, BERM, AND 10 OTHER LANDSCAPE DETAILS - 11 EX ASPHALT DRIVEWAY & PARKING TO REMAIN - 12 NEW ADA STALL STRIPING ON EX PAVEMENT - 13 3,114 SF RIGHT -OF -WAY DEDICATION - 14 PERPENDICULAR CURB RAMP K/C09 COMPACT PARKING STALL. STALLS TO BE MARKED 15 AS COMPACT. - LANDSCAPING PER LANDSCAPE ARCHITECTS 16 PLANS - 17 REMOVE EX LIGHT POLE - SECURED BICYCLE PARKING TO BE PROVIDED IN 18 EXISTING SHOP - .. 19 _ -20 o R1750 -- - - z 2.... 23 _._..,. --- - - - - -- — - -- -- - - -- — �.. 23 — --------- - - - - -- -- — 6.00 A.qr ° ° s ° ° �d 14. ' ^j . M .. \ _ \ w .................. \. 8.23 ............ ...... \ \. \: 6 ......... ......................... . .. . y ._._ ._ ._._..._.. w___ _.__..__ . - :. .\ ..x... .... .. .,.,... _._:;::.y:. ..arirra. aria_ ........., "\ .. .......... \ _..._ . w ..._.. _......_.. _.. \.. , . �- _. ............... .. ......moo \...... ...,......... . . \\\ \...:...• 3 13 ............. 13 :....................... ............................... 8 14 a- 0 6 _ \ 39.70 ......\....\...\.................\.. ............................\\........................ ............................... ........ \....... ........ ............................... .... L_.A CALL 2 DAYS ..................... . BEFORE YOU DIG \ \\ :: \\ ..; 1- 800 - 424 -5555 (UNDERGROUND UTILITY LOCATIONS ARE APPROX.) BASE MAP/TOPOGRAPHY PROVIDED BY OTHERS. DCG CANNOT BE HELD LIABLE FOR ACCURACY. CONTRACTOR SHALL DAVIDO CONSULTINGGROUP., INC. FIELD VERIFY GRADES. UTILITIES. AND ALL OTHER EXISTING FEATURES AND Civil • Structural ■ Land Use CONDITIONS. IF CONDITIONS ARE NOT AS SHOWN AND /OR PLANS CANNOT BE 1501-9 Bothell Way NE, Suite 600 CONSTRUCTED AS SHOWN. CONTACT Lake Forest Park, WA 98155 DCG PRIOR TO CONSTRUCTION. '106.523.0024 P.O. Box 1 132 Freeland, WA 98249 360.331.4131 SW 76TH STREET 'e A&. . A :... . \\� "RE wASy�ti SURVEYED: SCALE: co AS NOTED TIM GABELEIN DRAWN: NATHAN DAVIS ONE INCH 0 33723 10 CHECKED: AT FULL SCALE FG/STER�c (jam ERIK DAVIDO IF NOT ONE INCH NA- - NO. REVISION BY DATE A P P R : SCALE ACCOROINCLY ERIK DAVIDO VERMAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 A&: DATU M �- CITY OE RENTON Planning /Building /Public Works Dept. I IN COMPLIANCE WITH CITY OF RENTON STANDARDS R� BY. - Date: • Z BY. Date: BY.. Date: BY: Date: SHUTTLE EXPRESS - RENTON PARKING LOT °"2/10/2015 800 SW 16TH ST naDem RENTON, WA PAGE DRI11 M ND CO3 SITE PLAN SHED: 3 OF: 9 1�t- I I 1 �' cn T � • 2 , a J i Z er u D 0 D Z Z C Im m n Z T_ x X �. ' L - Z s m C 0 Y Z m D �' cn T � • 2 , a J i Z er u D 0 D Z Z C Im m n T_ x X �. ' L z m .. 0 T_ L m r LIJ z U LLJ Of a- a N ch 0 N _o N w 0 a. 0 J Y m Q_ CL X w L 0 z Q ro V 0 0 J Cn S Y m a C O a X LIJ n� 5 t W C a) U a 4i W J �- t- (n i CL TEMPORARY SEDIMENTATION 20 10 0 20 40 SCALE IN FEET EROSION AND CONTROL: 10. 11. 12. 13. ANY AREA NEEDING ESC MEASURES, NOT REQUIRING IMMEDIATE ATTENTION, SHALL BE ADDRESSED WITHIN SEVEN (7) DAYS. THE ESC FACILITIES ON INACTIVE SITES SHALL BE INSPECTED AND MAINTAINED A MINIMUM OF ONCE A MONTH OR WITHIN 24 HOURS FOLLOWING A STORM EVENT. AT NO TIME SHALL MORE THAN ONE (1) FOOT OF SEDIMENT BE ALLOWED TO ACCUMULATE WITHIN A CATCH BASIN. ALL CATCH BASINS AND CONVEYANCE LINES SHALL BE CLEANED PRIOR TO PAVING. THE CLEANING OPERATION SHALL NOT FLUSH SEDIMENT -LADEN WATER INTO THE DOWNSTREAM SYSTEM. DURING THE TIME PERIOD OF OCTOBER 1ST INSTALL APPROX. 150± LF PERIMETER PROTECTION A /C07 1. BEFORE ANY CONSTRUCTION OR E /C07 THROUGH MARCH 30TH, ALL PROJECT INSTALL APPROX. 222± LF PERIMETER PROTECTION A /C07 DEVELOPMENT ACTIVITY OCCURS, A z DISTRIBUTED SOIL AREAS GREATER, THAT �o INSTALL TEMPORARY STORM DRAIN INLET PRE - CONSTRUCTION MEETING MUST BE HELD 3 ARE TO BE LEFT UN- WORKED FOR MORE C /C07 WITH THE CITY OF RENTON, PUBLIC WORKS THAN 12 HOURS, SHALL BE COVERED BY PROTECTION ON ALL CATCH BASINS & INLETS IN EX C /C07 DESIGN ENGINEER. PARKING AREA MULCH, SODDING OR PLASTIC COVERING. O 2. THE BOUNDARIES OF THE CLEARING LIMITS 14. ANY PERMANENT RETENTION /DETENTION J AND AREAS OF VEGETATION PRESERVATION FACILITY USED AS A TEMPORARY SETTLING 0 - AS PRESCRIBED ON THE PLAN(S) SHALL BE INSTALL APPROX. 87± LF OF TEMPORARY TREE BASIN SHALL BE MODIFIED WITH THE 7 PROTECTION FENCING (CHAIN LINK) CLEARLY FLAGGED BY SURVEY TAPE OR NECESSARY EROSION CONTROL MEASURES Z 8 FENCING IN THE FIELD PRIOR TO B/C07 AND SHALL PROVIDE ADEQUATE STORAGE Y - CONSTRUCTION IN ACCORDANCE WITH INSTALL APPROX. 161± LF PERIMETER PROTECTION CAPACITY. IF THE PERMANENT FACILITY IS TO APPENDIX D OF THE SURFACE WATER DESIGN 11 FUNCTION ULTIMATELY AS AN INFILTRATION A /C07 MANUAL AND OBSERVED DURING E /C07 SYSTEM, THE TEMPORARY FACILITY MUST BE Q CONSTRUCTION. DURING THE CONSTRUCTION PROTECTION FENCING (CHAIN LINK) ROUGH GRADED SO THAT THE BOTTOM AND 0. CLEARING LIMITS PERIOD, NO DISTURBANCE BEYOND THE SIDES ARE AT LEAST THREE FEET ABOVE THE z 14 CLEARING LIMITS SHALL BE PERMITTED. THE - FINAL GRADE OF THE PERMANENT FACILITY. O CLEARING LIMITS SHALL BE MAINTAINED BY THE APPLICANT /ESC SUPERVISOR FOR THE 15. PRIOR TO THE BEGINNING OF THE WET 16 INSTALL APPROXIMATELY 213 LF STRAW WATTLES E /C07 17 SEASON (OCT. 1), ALL DISTURBED AREAS I­' DURATION OF CONSTRUCTION. SHALL BE REVIEWED TO IDENTIFY WHICH Z 3. STABILIZED CONSTRUCTION ENTRANCES ONES CAN BE SEEDED IN PREPARATION FOR w SHALL BE INSTALLED AT THE BEGINNING OF THE WINTER RAINS. DISTURBED AREAS SHALL CONSTRUCTION AND MAINTAINED FOR THE BE SEEDED WITHIN ONE WEEK OF THE DURATION OF THE PROJECT. ADDITIONAL BEGINNING OF THE WET SEASON. A SKETCH MEASURES, SUCH AS CONSTRUCTED WHEEL MAP OF THOSE AREAS TO BE SEEDED AND U) WASH SYSTEMS OR WASH PADS, MAY BE THOSE AREAS TO REMAIN UNCOVERED SHALL (n REQUIRED TO ENSURE THAT ALL PAVED BE SUBMITTED TO THE CITY OF RENTON FOR Uj AREAS ARE KEPT CLEAN AND TRACK OUT TO REVIEW. ROAD RIGHT OF WAY DOES NOT OCCUR FOR THE DURATION OF THE PROJECT. X 4. ALL REQUIRED SEDIMENTATION /EROSION w CONTROL FACILITIES MUST BE CONSTRUCTED AND IN OPERATION PRIOR TO LAND CLEARING W AND /OR CONSTRUCTION TO PREVENT U TRANSPORTATION OF SEDIMENT TO SURFACE �- WATER, DRAINAGE SYSTEMS AND ADJACENT �- PROPERTIES. ALL EROSION AND SEDIMENT FACILITIES SHALL BE MAINTAINED IN A Z SATISFACTORY CONDITION UNTIL SUCH TIME �' U) THAT CLEARING AND /OR CONSTRUCTION IS < COMPLETE AND POTENTIAL FOR ON -SITE EROSION HAS PASSED. THE IMPLEMENTATION, MAINTENANCE, REPLACEMENT AND ADDITIONS TO EROSION /SEDIMENTATION CONTROL SYSTEMS SHALL BE THE RESPONSIBILITY OF THE PERMITTEE. 5. THE EROSION AND SEDIMENTATION CONTROL SYSTEMS DEPICTED ON THIS DRAWING ARE o °` INTENDED TO BE MINIMUM REQUIREMENTS TO w MEET ANTICIPATED SITE CONDITIONS. AS CONSTRUCTION PROGRESSES AND ° '"�' UNEXPECTED OR SEASONAL CONDITIONS I �..:,. DICTATE, THE PERMITTEE SHALL ANTICIPATE ... THAT MORE EROSION AND SEDIMENTATION CONTROL FACILITIES WILL BE NECESSARY TO ENSURE COMPLETE SILTATION CONTROL ON zz THE PROPOSED SITE. DURING THE COURSE OF CONSTRUCTION, IT SHALL BE THE OBLIGATION AND RESPONSIBILITY OF THE X PERMITTEE TO ADDRESS ANY NEW CONDITIONS THAT MAY BE CREATED BY THE X, ACTIVITIES AND TO PROVIDE ADDITIONAL FACILITIES, OVER AND ABOVE MINIMUM REQUIREMENTS, AS MAY BE NEEDED, TO r- "''\ PROTECT ADJACENT PROPERTIES AND WATER QUALITY OF THE RECEIVING DRAINAGE SYSTEM. -X',- ��bHT X-1 6. APPROVAL OF THIS PLAN IS FOR o EROSION /SEDIMENTATION CONTROL ONLY. IT ` DOES NOT CONSTITUTE AN APPROVAL OF 19 \\ , STORM DRAINAGE DESIGN, SIZE NOR LOCATION OF PIPES, RESTRICTORS, CHANNELS OR RETENTION FACILITIES. 7. ANY AREAS OF EXPOSED SOILS, INCLUDING ROADWAY EMBANKMENTS, THAT WILL NOT BE a. ° LLL DISTURBED FOR TWO DAYS DURING THE WET :....: ' a SEASON (OCTOBER 1 ST THROUGH MARCH 30TH) OR SEVEN DAYS DURING THE DRY =-=... _ .............................: :.......... :::.................... SEASON (APRIL 1ST THROUGH SEPTEMBER 30TH) SHALL BE IMMEDIATELY STABILIZED WITH THE APPROVED ESC COVER METHODSs,r (E.G., SEEDING, MULCHING, PLASTIC COVERING, ETC.). ...... ................ ............... ........... 8. WET SEASON SEASONAL EROSION AND =. . - SEDIMENT CONTROL REQUIREMENTS APPLY TO ALL CONSTRUCTION SITES CLEARING BETWEEN OCTOBER 1 AND MARCH 30 INCLUSIVE, UNLESS OTHERWISE APPROVED BY THE CITY THROUGH AN ADJUSTMENT PROCESS. 9. COVER MEASURES WILL BE APPLIED IN CONFORMANCE WITH APPENDIX D OF THE SURFACE WATER DESIGN MANUAL. _,: BEFORE YOU DIG Av 1- 800 -424 -5555 C.> (UNDERGROUND UTILITY LOCATIONS ARE APPROX.) BASE MAP/TOPOGRAPHY PROVIDED BY OTHERS. DCG CANNOT BE HELD LIABLE DAVIDO FOR ACCURACY. CONTRACTOR SHALL CONSULTINGGROUP, INC. FIELD VERIFY GRADES. UTILITIES. AND ALL OTHER EXISTING FEATURES AND Civil • Structural ■ Land Use CONDITIONS. IF CONDITIONS ARE NOT AS SHOWN AND /OR PLANS CANNOT BE 1501-9 Bothell Way NE. Suite 600 CONSTRUCTED AS SHOWN, CONTACT Lake Forest Park, WA 98155 DCG PRIOR TO CONSTRUCTION. '106.5-233.0024 P.O. Box 1132 Freeland, WA 98249 360.331.4131 CONSTRUCTION ACTIVITY SCHEDULE- 1 . PRE - CONSTRUCTION MEETING. 2. POST SIGN WITH NAME AND PHONE NUMBER OF ESC SUPERVISOR (MAY BE CONSOLIDATED WITH THE REQUIRED NOTICE OF CONSTRUCTION SIGN). 3. FLAG OR FENCE CLEARING LIMITS. 4. INSTALL CATCH BASIN PROTECTION IF REQUIRED. 5. GRADE AND INSTALL CONSTRUCTION ENTRANCE(S). 6. INSTALL PERIMETER PROTECTION (SILT FENCE, BRUSH BARRIER, ETC.). 7. CONSTRUCT SEDIMENT PONDS AND TRAPS. 8. GRADE AND STABILIZE CONSTRUCTION ROADS. 9. CONSTRUCT SURFACE WATER CONTROLS (INTERCEPTOR DIKES, PIPE SLOPE DRAINS, ETC.) SIMULTANEOUSLY WITH CLEARING AND GRADING FOR PROJECT DEVELOPMENT. 10. MAINTAIN EROSION CONTROL MEASURES IN ACCORDANCE WITH APPENDIX D OF THE SURFACE WATER DESIGN MANUAL AND MANUFACTURER'S RECOMMENDATIONS. 11. RELOCATE EROSION CONTROL MEASURES OR INSTALL NEW MEASURES SO THAT AS SITE CONDITIONS CHANGE THE EROSION AND SEDIMENT CONTROL IS ALWAYS IN ACCORDANCE WITH THE CITY'S EROSION AND SEDIMENT CONTROL STANDARDS. 12. COVER ALL AREAS THAT WILL BE UNWORKED FOR MORE THAN SEVEN DAYS DURING THE DRY SEASON OR TWO DAYS DURING THE WET SEASON WITH STRAW, WOOD FIBER MULCH, COMPOST, PLASTIC SHEETING OR EQUIVALENT. 13. STABILIZE ALL AREAS THAT REACH FINAL GRADE WITHIN SEVEN DAYS. 14. SEED OR SOD ANY AREAS TO REMAIN UNWORKED FOR MORE THAN 30 DAYS. 15. UPON COMPLETION OF THE PROJECT, ALL DISTURBED AREAS MUST BE STABILIZED AND BMPS REMOVED IF APPROPRIATE. :....: R... . S. DA ._ of W , �O O 33723 GI S T ERA NAL NO. REVISION KEY NOTES KEY DESCRIPTION DETAIL /SHEET 1 INSTALL APPROX. 150± LF PERIMETER PROTECTION A /C07 z C z E /C07 2 INSTALL APPROX. 222± LF PERIMETER PROTECTION A /C07 A z E /C07 �o INSTALL TEMPORARY STORM DRAIN INLET SURFACE WATER DESIGN MANUAL. 3 PROTECTION C /C07 INSTALL TEMPORARY STORM DRAIN INLET 4 PROTECTION ON ALL CATCH BASINS & INLETS IN EX C /C07 PARKING AREA D INSTALL APPROX. 107± LF OF TEMPORARY TREE 5 PROTECTION FENCING (CHAIN LINK) D /C07 USE EX CONC DRIVEWAY AS CONSTRUCTION 6 ENTRANCE - INSTALL APPROX. 87± LF OF TEMPORARY TREE 7 PROTECTION FENCING (CHAIN LINK) D /C07 INSTALL TEMPORARY STABILIZED CONSTRUCTION 8 ENTRANCE B/C07 9 REMOVE EXISTING TREE - 10 INSTALL APPROX. 161± LF PERIMETER PROTECTION A/C07 E /C07 11 INSTALL APPROX. 68± LF PERIMETER PROTECTION A /C07 E /C07 INSTALL APPROX. 54± LF OF TEMPORARY TREE 12 PROTECTION FENCING (CHAIN LINK) D /C07 13 CLEARING LIMITS - CONTRACTOR TO SWEEP STREET DAILY OR MORE 14 OFTEN IF NECESSARY TO REMOVE TRACKED - SEDIMENT FROM THE SITE 15 INSTALL APPROXIMATELY 154 LF STRAW WATTLES E /C07 16 INSTALL APPROXIMATELY 213 LF STRAW WATTLES E /C07 17 INSTALL APPROXIMATELY 40 LF STRAW WATTLES E /C07 ..... .... ........._.._._....... ._.................._....._.... _....._.............._ ......_....,.__...... .. ._.. .... -.. __ _. ..........,.._.... __._.._ 14 SW 16TH STREET SURVEYED: DESIGNED: TIM GABELEIN DRAWN: NATHAN DAVIS CHECKED: ERIK DAVIDO BY DATE APPR AEON ERIK DAVIDO SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL NAD 1983/1991 DATU M � - CITY OE RENTON Planning /Building /Public Works Dept. CONTRACTOR 1. STAKE OFF AND MARK INFILTRATION AREAS TO PREVENT COMPACTION BY EQUIPMENT AND TRAFFIC. 2. SEDIMENT AND RUNOFF MUST BE KEPT AWAY FROM INFILTRATION AREAS. 3. ONLY LOW PRESSURE TIRE OR TRACK VEHICLES SHALL BE OPERATED OVER THE INFILTRATION SYSTEMS DURING CONSTRUCTION. COMPACTION EQUIPMENT SHALL BE LIMITED TO A MAXIMUM GROSS VEHICLE WEIGHT OF SIX (6) TONS. TRIAXIAL DUMP TRUCKS AND DIRT PANS SHALL NOT BE OPERATED IN THE INFILTRATION SYSTEM FOOTPRINT AT ANY TIME. WHERE NECESSARY, THE HEAVY EQUIPMENT SHOULD UNLOAD IN AN AREA ADJACENT TO THE INFILTRATION SYSTEM AND THE MATERIAL SHOULD BE MOVED OVER THE SYSTEM WITH TRACKED EQUIPMENT. WINTER GRADING NOTE: 1. FROM OCTOBER 1 THROUGH APRIL 30, NO SOILS SHALL REMAIN EXPOSED FOR MORE THAN 2 DAYS. FROM MAY 1 THROUGH SEPTEMBER 30, NO SOILS SHALL REMAIN EXPOSED FOR MORE THAN 7 DAYS. ADJACENT PROPERTIES SHALL BE PROTECTED FROM SEDIMENT OR STORMWATER RUNOFF BY VEGETATIVE BUFFER STRIPS, SEDIMENT BARRIERS, FILTERS, BERMS, OR OTHER SUITABLE METHOD TO INSURE THEIR PROPERTY IS NOT DAMAGED. R- 380904 IN COMPLIANCE WITH CITY OF RENTON STANDARDS BY Date: • Zv /= BY: Date: BY: Date: BY: Date: DATE: SHUTTLE EXPRESS - RENTON PARKING LOT 2/10/2015 800 SW 16TH ST nano°°" PAGE RENTON, WA 0PAIIIIIIINIG No: TESC PLAN C04 am: g OF: �\,.IIN I N\,' N\'�' s m z � z Z D 0 D Z G1 Z C 9 m m t x T 8 ": -- x z C z Z f 1 *INSTALL PERIMETER PROTECTION SUCH AS SILT FENCING, COMPOST SOCKS OR A z STRAW WATTLES IN ACCORDANCE WITH APPENDIX D OF THE 2009 KING COUNTY �o SURFACE WATER DESIGN MANUAL. z m m INFILTRATION PROTECTION AREA GENERAL NOTES FOR D CONTRACTOR 1. STAKE OFF AND MARK INFILTRATION AREAS TO PREVENT COMPACTION BY EQUIPMENT AND TRAFFIC. 2. SEDIMENT AND RUNOFF MUST BE KEPT AWAY FROM INFILTRATION AREAS. 3. ONLY LOW PRESSURE TIRE OR TRACK VEHICLES SHALL BE OPERATED OVER THE INFILTRATION SYSTEMS DURING CONSTRUCTION. COMPACTION EQUIPMENT SHALL BE LIMITED TO A MAXIMUM GROSS VEHICLE WEIGHT OF SIX (6) TONS. TRIAXIAL DUMP TRUCKS AND DIRT PANS SHALL NOT BE OPERATED IN THE INFILTRATION SYSTEM FOOTPRINT AT ANY TIME. WHERE NECESSARY, THE HEAVY EQUIPMENT SHOULD UNLOAD IN AN AREA ADJACENT TO THE INFILTRATION SYSTEM AND THE MATERIAL SHOULD BE MOVED OVER THE SYSTEM WITH TRACKED EQUIPMENT. WINTER GRADING NOTE: 1. FROM OCTOBER 1 THROUGH APRIL 30, NO SOILS SHALL REMAIN EXPOSED FOR MORE THAN 2 DAYS. FROM MAY 1 THROUGH SEPTEMBER 30, NO SOILS SHALL REMAIN EXPOSED FOR MORE THAN 7 DAYS. ADJACENT PROPERTIES SHALL BE PROTECTED FROM SEDIMENT OR STORMWATER RUNOFF BY VEGETATIVE BUFFER STRIPS, SEDIMENT BARRIERS, FILTERS, BERMS, OR OTHER SUITABLE METHOD TO INSURE THEIR PROPERTY IS NOT DAMAGED. R- 380904 IN COMPLIANCE WITH CITY OF RENTON STANDARDS BY Date: • Zv /= BY: Date: BY: Date: BY: Date: DATE: SHUTTLE EXPRESS - RENTON PARKING LOT 2/10/2015 800 SW 16TH ST nano°°" PAGE RENTON, WA 0PAIIIIIIINIG No: TESC PLAN C04 am: g OF: �\,.IIN I N\,' N\'�' s m z � z Z D 0 D Z G1 Z C 9 m m T 8 ": -- x O v 2 z 1 D z �o T 8 O D - C U9 9 > Z oc z r. 46 .. O a m z G z c 3 m m CN O LC) C) C14 LLI 0 -i CL c 0 c W (A W CL x w :3 I_- 0 99 LL. oc r. 46 .. O c 0 c W (A W CL x w :3 I_- 0 99 LL. �/1 V Cn 1 CL CL CL L1 % L� LJ z I^_ C_ Q z O z w I w CL X w w J Cn a_ N ch LO V_ O N O _ N w 0 0 CL CM 10 0 J C Y a N N a X LU z 0 c� 0 0 J C Y M a C _0 C CL N N a� X w a� L (n C Q) U a 0 1 iU-) FILTER FABRIC MATERIAL 60" WIDE BOLLS. USE STAPLES OR WIRE RINGS TO ATTACH FABRIC TO WIRE MIRAFI 70OX OR PRE - APPROVED EQUAL 2" X 2" X 14ga IMRE FABRIC OR EQUIV. (OPTIONAL -PER SITE CONDITION) BURY BOTTOM OF FILTER MATERIAL IN 8" X 12" TRENCH co FILTER FABRIC MATERIAL o • NOTE: ANGLE SILT FENCE BACK UP THE I SLOPE AT THE END OF RUN. c LO s BACKFILL NTH NATIVE SOIL MATERIAL OR GRAVEL BACKFILL IN TRENCH AND ON BOTH SIDES OF FENCE FABRIC ON THE SURFACE SILT FENCE A PER KING COUNTY FIGURE DA.E. C04 NTS goo R =25' MIN. 4' -8' QUARRY SPALLS --***j GE0- TEXTILE FABRIC LENGTH PER THE DPD SITE DEVELOPMENT INSPECTOR ��. ar �. 1 PROVIDE FULL WIDTH INGRESS/EGRESS AREA 12" MIN. THICKNESS � STABILIZED ACCESS SHALL BE USED IN ALL AREAS OF THE SITE WITH VEHICLE TRAFFIC AND PARKING, INCLUDING PLANTING STRIPS. OTHER MEANS OF PROVIDING STABILIZED ACCESS WILL BE CONSIDERED. STABILIZED CONSTRUCTION ENTRANCE B PER KING COUNTY FIGURE DA.G. 204 NTS NOTES: 1. STORM DRAIN INLETS NEED TO BE REMOVED OVERFLOW (TO BYPASS AT THE END OF THE JOB. 2. STORM DRAIN INLET'S ARE ONLY TO BE PEAK STORM VOLUMES) INSTALLED IN DRAINAGE DEVICES PER THE MANUFACTURER'S RECOMMENDATIONS. CATCH BASIN INSERTS ARE NOT TO BE INSTALLED IN CURB INLETS. 3. INSERTS SHALL BE INSPECTED AND MAINTAINED WHEN A 1/2 INCH RAIN ACCUMULATES WITHIN A 24 HOUR PERIOD. CLEAN AND /OR REPLACE INSERT WHEN HALF OF THE TRAP IS FILLED WITH SEDIMENTS. CB INLET PROTECTION c PER KING COUNTY FIGURES DA.L. & D.4.M. 204 CALL 2 DAYS NTS BEFORE YOU DIG 1- 800 - 424 -5555 (UNDERGROUND UTILITY LOCATIONS ARE APPROX.) BASE MAP/TOPOGRAPHY PROVIDED BY OTHERS. DCG CANNOT BE HELD LIABLE FOR ACCURACY. CONTRACTOR SHALL DAVIDO CONSULTINGGROUP, INC. FIELD VERIFY GRADES. UTILITIES, AND ALL OTHER EXISTING FEATURES AND Civil • Structural • Land Use CONDITIONS. IF CONDITIONS ARE NOT AS SHOWN AND /OR PLANS CANNOT BE 15029 Bothell Way NE, Suite 600 CONSTRUCTED AS SHOWN.. CONTACT Lake Forest Park, WA 98155 DCG PRIOR TO CONSTRUCTION- '106.521".0014 P.O. Box 1 132 Freeland, WA 98249 360.331.4131 6' HIGH 11.5 GAUGE CHAIN LINK TENSION WIRE OR TOP RAIL (TYP) 8' MAX FABRIC, 3'-4' `, k �X z C (1.2m) -` ACP Class B) SECURE FENCE OVER k 1 FABRIC TO POSTS WITH Strew RON@ Must ton �W M 3 (MIN) ALUMINUM �X �_v , .. �` Slope Contours TIES PER POST STREET MINIMUM Adjacent rolls shall ACP Closs B), tightly abut —, OVER 6'' CRUSHED ROCK ✓y j 10"-25'(3-8m) R` \.� 2-1/4" X 2 -3/4" X T 6 FT 13 GAUGE METAL 2' BURY MIN U- CHANNEL FENCE POST (TYP); IN RIGHT OF WAY, USE CONCRETE PIER BLOCK NOTE: WHERE CHAIN LINK FENCE IS TO BE INSTALLED NEAR TREES, FENCE SHALL BE AT DRIP LINE OR AS DIRECTED BY ENGINEER. TEMPORARY TREE PROTECTION FENCING (CHAIN LINK) NTS A �O of WAS / Al O 33723 GISTER� S�ONAL t to scale (25 x 25mrn) NOZZ: 1. Straw roll installation requires the placement and secure staking of the roll in a trench., 3 " -S" (73- 125mm) deep, dug on contour. runoff rust not be allowed to run under or around roll. STRAW WATTLE E NTS C04 REVISION SURVEYED: DESIGNED: TIM GABELEIN DRAW: NATHAN DAVIS CHECKED: ERIK DAVIDO BY DATE APPR : ERIK DAVIDO 12" 1" MIN. (TYP.) CEMENT CONCRETE EXTRUDED CURB 10" 2 1 /2" 1 5" _ 1 2 1Z2 101 - 011 SPACING OF ANCHOR BARS # 3 BARS (TYP.) SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDIMLY VERTICAL NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM .._.__. -._. P A VE Iv; E N T SAW(_.'.'UT (SEE NOTE 2) I 3'-4' ARTERIAL STREET MINIMUM. z C (1.2m) -` ACP Class B) (SEE NOTE 1), OVER r 6'' CRUSHED ROCK Strew RON@ Must ton �W M Be Placed Along Slope Contours RESIDENTIAL STREET MINIMUM Adjacent rolls shall ACP Closs B), tightly abut —, OVER 6'' CRUSHED ROCK ✓y j 10"-25'(3-8m) R` \.� AA ds , - an Sall Type and 1. Sediment, organic ma. -. Slope S ss ., and nave seeds are captumd behind the rolls. f :l} 3 " -5• (75 -125mm) ( 200- 250mm) Live Stake 'r4` I" X 1 " Stake A �O of WAS / Al O 33723 GISTER� S�ONAL t to scale (25 x 25mrn) NOZZ: 1. Straw roll installation requires the placement and secure staking of the roll in a trench., 3 " -S" (73- 125mm) deep, dug on contour. runoff rust not be allowed to run under or around roll. STRAW WATTLE E NTS C04 REVISION SURVEYED: DESIGNED: TIM GABELEIN DRAW: NATHAN DAVIS CHECKED: ERIK DAVIDO BY DATE APPR : ERIK DAVIDO 12" 1" MIN. (TYP.) CEMENT CONCRETE EXTRUDED CURB 10" 2 1 /2" 1 5" _ 1 2 1Z2 101 - 011 SPACING OF ANCHOR BARS # 3 BARS (TYP.) SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDIMLY VERTICAL NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM .._.__. -._. P A VE Iv; E N T SAW(_.'.'UT (SEE NOTE 2) I NTS ? n% MIN kTION USING ;RETE CURES Cfb 12 of 2, SAWCU'-1' SHALL BE POSITIONED — 0" BEYOND EDGE OF DAMAGED PAVEMENT. 3. THE INTENT OF THIS DESIGN IS TO DESCRIBE PAVEMENT PLACEMENT AT THE GUTTER FACE. SEE STANDARD PLAN FOR CEMENT CONCRETE CURBS. CURB & GUTTER REPLACEMENT /-G-'N IN COMPLIANCE WITH CITY OF RENTON PER CITY OF RENTON STD PLAN 103 CO3 STANDARDS NTS - BY: Date: • BY: Date: BY: Date: BY: Date: or►TE: CITY OF SHUTTLE EXPRESS - RENTON PARKING LOT 2/1 0/2015 800 SW 16TH ST An °°" RENTON RENTON, WA No: Planning /Building /Public Works Dept. C07 DETAILS 7 OF:9 I N NIN 70 Z ARTERIAL STREET MINIMUM. z C 7', HMA (or ACP Class B) (SEE NOTE 1), OVER r 6'' CRUSHED ROCK m ton �W M D RESIDENTIAL STREET MINIMUM 4" HMA (or ACP Closs B), (SEE NOTE 1), OVER 6'' CRUSHED ROCK NTS ? n% MIN kTION USING ;RETE CURES Cfb 12 of 2, SAWCU'-1' SHALL BE POSITIONED — 0" BEYOND EDGE OF DAMAGED PAVEMENT. 3. THE INTENT OF THIS DESIGN IS TO DESCRIBE PAVEMENT PLACEMENT AT THE GUTTER FACE. SEE STANDARD PLAN FOR CEMENT CONCRETE CURBS. CURB & GUTTER REPLACEMENT /-G-'N IN COMPLIANCE WITH CITY OF RENTON PER CITY OF RENTON STD PLAN 103 CO3 STANDARDS NTS - BY: Date: • BY: Date: BY: Date: BY: Date: or►TE: CITY OF SHUTTLE EXPRESS - RENTON PARKING LOT 2/1 0/2015 800 SW 16TH ST An °°" RENTON RENTON, WA No: Planning /Building /Public Works Dept. C07 DETAILS 7 OF:9 I N NIN 142 l �s �Z y� = P �z z 0 M n z z C 3 M M 70 Z z C z T v r O -z m ton �W M D 142 l �s �Z y� = P �z z 0 M n z z C 3 M M D r — - _C v i r' .� v ^J O ton �W z D lz L1J Z LLJ U X D_ 2 CL 04 L0 0 _N O (V W H Q 0 0 J a W J F_ F_ F_ F_ r 1 rVn, V 1 CL CL CL III- 0 J Z FACE OF CURB J 1 _ r 2 T _ 51,2` t Qt 71 -- -� JO ?' R. 1 R. ' ;24 r I ' TOP OF Z 1.2* R. ROADWAY Z Z' D Z, W .. 1 6 CEMENT CONCRETE TRAFFIC CURB AND GUTTER V U U) w FACE OF ADJACENT CJR8 -- FLUSH wITH GUT-TER PAN AT SIDEWALK RAMP E NTRANC E X 1.12 1:24 W ? OP OP W 1 '2" R. ROADINAY D !. 1 • 6" C) DEPRESSED CURB SECTION AT SIDEWALK RAMOS 61 CEMENT CONCRETI .. R SIDEINALK RA M iAN VARIES RDIN: FRONT 3,,"B" PREMOLDED JOINT FILLER CEMENT CONCRETE PEDESTRIAN CURS AT SIDEWALK RAMPS AND LANDINGS FACE OF ADJACENT CURB SEE DEPRESISED CURB DETAIL T-JIS SHEET 114 TOP OF , 1;2;. R. ROADO'AY. R 4. *\ -t DEPRESSED CURB SECTION AT RESIDENTIAL DRIVEWAYS ONLY, FOR COMMERCIAL DRIVEWAYS SEE STD PLAN 104.2 1 >2" R, FACE. OF ADiAl;ENT CURB GUTTER SURFACE t FACE OF CURB 6 1/2" 1., DEPRESSED CURB DETAIL AT RESIDENTIAL. OR COMMERCIAL DRIVEWAYS, AND ALLEYS GENERAL NOTES 1. See standard plans 102 and 1,01: 1 for cart. ie xpiansior� ar d antract or joint, spacing, 2. Not used. 3. For Depressed Monolithic IDrIveway Curie & Gutter Section, see Standard Piart 104.2 :Zg P BLIP WORKS DEPARTMENT CALL 2 DAYS BEFORE YOU DIG 1- 800 - 424 -5555 (UNDERGROUND UTILITY LOCATIONS ARE APPROX.) CEMENT CONCRETE CURBS CEMENT CONCRETE CURBS � PER CITY OF RENTON STD PLAN 101 CO3 NTS TOP OF ROAD AY STD . PLAT — 101 : :. l�14 E =._ BASE MAP/TOPOGRAPHY PROVIDED BY OTHERS. DCG CANNOT BE HELD LIABLE FOR ACCURACY. CONTRACTOR SHALL DAVIDO CONSULTINGGROUP, INC. FIELD VERIFY GRADES. UTILITIES. AND ALL OTHER EXISTING FEATURES AND Civil • Structural • Land Use CONDITIONS. IF CONDITIONS ARE NOT AS SHOWN AND /OR PLANS CANNOT BE 1501-9 Bothell Way NE. Suite 600 CONSTRUCTED AS SHOWN, CONTACT Lake Forest Park. WA 98155 DCG PRIOR TO CONSTRUCTION. '106.523.0024 P.O. Box 1 132 Freeland, WA 98249 360.331.4131 NO. —_ SEE C° !:TtiA I ;�c yo► =�� : P CURB NOT INCLUOLD IN BID ►, EM - � �z EE i AISEC ED'C E t y .;tv: PRt „'OLDELD T�iS SHEET SLOPES 2 17 {Iv.. k. P. MTH �; :5'<D EDGE J OR .� 38' :IN PREMCLDED ' FINISHED GRADE 1 •;N; BE.iv�1' JOINT FILLER TOP OF CONCRETES }RACE - C SIDEWALK ADJACENT TO CURB 'u {N ?SEE CONTRAC'} RO:i DINts CURB NOT INCLUDED IN S:L 1 TI =T.a ,- 5RIOGE OR PEDESTRIAN PREMO' LDED ' !`• ' a • WALL OR BARRIE RAILING JOINT Fts_LER ADJACENT TO CURB BARRIER - SEE SIDEtiVALK (STEEP FI -L SLOPES: CONTRACT PLANS i ;SEE CONTRACT; WALL Ok BARRIER i t (ICI: R (TYP.: �. . LAS , r 1 5 CURB NOT INCLUDED IN BID ITEM - SIDEWALK 41to - *w�vVERTICAL. WALL - 3r8' ;IN) PRE tOLDEO •«- - f -� : • SEE DETAIL OINT FILLER (TYP.i ' • : , • • •. f�� ADJACENT TO CURB AND RAILING OR WALL 313' cty, t =REtAo jLDED JOINT FILLER SIDEWALK BUFFER S -RIP (SEE CONTRACT I SEE NOTE t; 1r2- TIN: R. ' SIDEWALK ADJACENT TO WALL DETAIL �1 TYP., CURB NCT INCi_:. °7E [N BID ITEM - 1 5 5 MIN 6 aS •4 LEVEL FINtSHED GRADE V €N; BELOW TOP OF CONCRETE • SURFACE FOR PLA14MNG - FLUSH IF PAVED z . •i • ADJACENT TO BUFFER STRIP ,' .l ` ` `IN • �'•' ` • ' SROOMED FINISH • l _.._' , �' a 4` WIDE SMOOTH • !” �. '` �y �', TROWELED PER METER RAISED EDGE DETAIL EX?END SIDEWALK TRANSVERSE JO INTS TO INCLUDE RA►SE-I EDGE y$�s 0 "� r q � f CEMENT CONCRETE CURB (CURB AND GUTTER SHOWN: NOT INCLUDED IN BID ITEM �> N i For NOTES see STD PLAN 104.2. M ra Paved surfaces must comply with STD PLAN 102.1 as applicable Z 18 TO 14 CONTRACTION 1OIHT \ _ IN WALK O SIDEWALK S 'siLY •�. �� ` ' Vii: � � ' • � B `�d. • � • `�y. • EXPANSION JOINT IN BOTH •'� r0 ,' ► • •A.'�• �O CURB AW SIDEWALK i SEE STD PLAN 101 i • •� q R • . r � 9 G, PUBLIC WORKS DEPARTMENT REVISION "NT AND FINISH PREMOLDED F JOI DETAIL NT ILLER E EXPANSION JOINT C CONTRACTION JOINT CEMENT CONCRETE STD• PLAN — 102 SIDEWALK PPRO 'ED- I Gregg Zimmerman, Public Works Administrator CONCRETE SIDEWALK DETAIL too""F� PER CITY OF RENTON STD PLAN 102 003 NTS SURVEfED: DesaGNED: TIM GABELEIN DRWN: NATHAN DAVIS CW -CKm: ERIK DAVIDO BY DATE AP P R APPROVED: ERIK DAVIDO SCALE: AS NOTED ONE INCH AT FULL SALE IF NOT ONE INCH SALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM NOTES 1. When ai driveway width excess 15 feWtz, oonstruct a full depth expansion joint wfth 3/8" joint filler along the driveway lane lines (see std. plan 102). Construct expansion JoInts parallel with the centallne as required at 15' mulmum spackV when dtivewey W dths exceed 30'. 2. See std. plan 102 for sidewalk, details, 3. Curb and gutter shown, other curb designs ray be specified. See std, plan 101 for Curti doWls. 4. Not used, �y MONOUTW. c:uRe a c�uT>r� (M DETAIL IM SHEET) TYPE C2B - ISOMETRIC VIEW (COMMERCIAL, W TH BUFFER) 8, The engineer Will design all drtveways to Include elevatlons at all points marked with symbol "X *. All Ielevafions we at the back of curb top on uphill side. 8. Not used. 7, For Ddve"y Widths ses► DRIVEWAY STANDARDS (See NOTE 10). The expansion joints (see std. plan 102) shall be spaced as shown In the corresponding lsorr3etric view. 8, Slopes SINN comply with sections R303.2.1 or R303.2.2 or R303.2.3 of the Revised Dmft Guidelines for Acemible Public Rights- of-Way of November 23, 200 (PROWAG)r 9, Curb returns ibr any Type C -MAX Drtveway may be approved an a case•by -cake basis. M STREET STANDARDS = Renton Municipal Code (RMC) Tdle IV Development Regulations CHAP'T'ER 6 STREET AMID LITILITY STANDARDS Section 4-6-060 MEET STANDARDS DRIVEWAY STANDARDS = Renton Municipal Code (RMQ 11tie IV Development Regulations CHAPTER 4 CITY -WIDE PROPERTY DEVELOPI IMT STANDARDS Section 4••4-M PARKING, LOADING AND DRIVEWAY REGULATIONS CEMENT CONCF*-TE Cm a au im (SEE NOTE 3) FACE OF CLNM SEE SEE oEPREssED CLM DETAIL COW RAC TION JOWT _ e trr — am THw SHEET sTO P tae s trr iR• R. TOPOF •" ` ♦ 1 ROADMY NOM ORIVENMAy LONGRUOWAL 9WAI1* 10N JOWM SWLL W FULL OEP I H DEPRESSED MONOLITHIC CURS a GUTTER DETAIL FADE OF ADJACENT CUM 1 R = SURFACE DEPRESSED CURB DETAIL AT RESIDENTIAL OR COWAERCLAL DRIVEWAYS, AND ALLEYS Ddveway Example: TYPE C'I B R�ResldenlW, c=Co�r►aa� - � � 1 1!I*ITtbsr of L n", (MAXI Lens Cort'rrrr AQ CEMENT CONCRETE DMVEWAY ENTRANCES NOTES AND DETAILS CEMENT CONCRETE DRIVEWAY H PER CITY OF RENTON STD PLAN 104.2 CO3 NTS �- CITY OE RENTON Planning /Building /Public Works Dept. R- 380901 s'1'fl. RM - 104.8 IN COMPLIANCE WITH CITY OF RENTON S ANDARDS BY: ✓ "" Date: BY: Date: BY: Date: BY: Date: SHUTTLE EXPRESS - RENTON PARKING LOT a2/1 2/10/2015 800 SW 16TH ST naliso - RENTON, WA DP.VMM 00. DETAILS C08 am 8 m 9 D r ri • Z T Z _ z D 0 D Z G1 Z C 3 M a J 1 _ O 2 T _ Z T x - 1 71 -- -� JO r Z % r.. 7 Z 7 Z' D D r ri • Z T Z _ z D 0 D Z G1 Z C 3 M a J 1 _ O x x - - ., 4 71 -- -� JO r Z % r.. 7 Z J O r _ LLJ Z LAJ U 7) a M M Ln 0 N 0 r- N w Q 0 0 J a- 3 v 0 J rn Y M Q_ N N N Q X w a� t c� _z Q a: 0 0 0 J rn Y Q_ C 0 C n� o: a X w a>' t 5i 0 U Qr W W J L� �/ 1 �U) U) I 0. 0. J Z Y Q Z O z w o� w a X w w z CURB RAMP WIDTH 4'- 0" MIN_ LANDING TO MATCH o CURB RAMP WIDTH - SEE CONTRACT PLANS a I GRADE BREAK LANDING .. m GRADE BREAK SEE CONTRACT PLANS CURB RAMP I r'- 4- - 0" MIN. CEMENT CONCRETE SIDEWALK - SEE CONTRACT PLANS - I Z-CURS PROMI DE SM OQTH SEE M07E 5 4 - D" MIN. � CEWNT CONCRETE TRANSITION TO SIDEWALK - SEE NOTE 5 VSID WALKP � SEE CONTRACT PLANS - � d' - a" MIN _ wuuc FLARE3A" EXPANSION JONT (TYP.) M SEE srANAARO PLAN F X10 GRADE BREAK N13" EXPANS ION JOINT (TYR.) SEE RAMP STANDARD PLAN F�Q.10 yr I # MOTES C IJRB RAMP WIDTH 4' - a "MIN N. 1. provide a separate Curb Ramp for each awked or unmarked crosswa Ik. LANDING TO MATCH CURB RAMP A'/ Curb Ramp location shall be placed within the width of the associaked WIDTH SEE CONTRACT PLANS 0 -10 cnosswsllk or as shown in the Contract Plans. 0 -5 SLOPE VARIES � -- GRADE BREAK 2. 1IUflere "G RADE B REAI'C' is ca I led out the enti re length of the g rude METHOD � .....�.::.,.,, ,.;..;.....,, LOW PERMEABILITY NO. 30 MAX. break belvween the two s4 ace nt swftce planes shall be flush. BACKFILL TO D 4491 3. Do not place Gratings, J u action Boxes, Access Comers, o r other a pp ur *- - D 4632 a,� _ 160 LB MIN. n a noes in front of the Curb Ramp or on any part of the Curb Ramp or \ I MIN. ' SEE CONTRACT PLANS - Landing. 2. onl MAx- i " ' - 4. See the Contract plans for the curb design specified. See Standard Plan 2:50% CONSTRUCTION GEOTEXTILE BUFFER WIDTH -- MATCH TO FOR SEPARATION, NON -WOVEN F -10.12 fa r Cu rb, Cu rb and G utter, Depressed C urb and Gutter, and SECURE TO CONC CURB; WHERE NO FROM HEAVY EQUIPMENT WHEREVER �CURB RAMP DEPTH (TYR) POSSIBLE (SEE NOTE 3 BELOW) pedestrian Curb details. I •ti 140 LB MIN. 270 LB MIN. 180 LB MIN. PUNCTURE RESISTANCE 5. See Stsndar+d Plan F -3x.10 for Cement Concrete Sidewalk details. GRADE ? �^ ---_ ,, rr BREAK `'a: TRANSITION TO SIDEWALK BUFFER, IF % � See Gontract Plans f6r width and placement of sidewalk. PRESENT. OR TO BACK OF CURB (TYP.) 3 6. The Bid Item "Cement Concrete Curb Ramp Type does not include . » »» SEE TRACT LAN •' CON PLANS t'o 09G . ».. »:. IIAAX• _ __ ___ - -- Gutter, Depressed b , �1. ���•�.NNY �• ID• C V G 1 Pedeatr'ia n Curb, or Sidewa I k. CURB, OR CURB --- - -� _ -� -- � CEMENT CONCRETE AND GUTTER , CURB. OR CURB {r 'ti �� SEE NpTE 4 _ -- -- - AND GUTTER � -� PEDESTRIAN CURB �• 7. The Curb Ramp maximum running sbpe shah not t�aquire the ramp length - DETECTABLE WARNING SURFACE -� SEE NOTE 4 SEE NOTE d to exceed 15- f+ee�t to avoid chasing the slope irxlefinilely *ten connecting SEE STANDARD PLAN F46.10 �. DETECTABLE WAR N I NG SU RFACE - to �p grades. When applying the 154aot maximum Iength, the run ring FACE OF CURB / - f L SEE STANDARD PLAN F -4b.io slope at the Curti Ramp MA as tat as %asib e. FACE O F C UR8 .; 8. Curb Ramp, Landi and Flares shall rewive broom finish. See �11SURED PARALLEL � � 1�` DEPRESSED CURB AND GUTTER 4 � �'� DEPRESSED CUR6/lND GUTTER p � TO CURB (TYP.) J CROSS1tW11LK SEE NOTE 4 CROSSWALK Standard Spec lflCatlOflS 8-14. LEGEND SLOPE IN EITHER DIRECTION PLAN VIEW PLAN VIEW TYPE PERPENDK±ULAR A TYPE PERPENDICULAR. B DETECTABLE WARNING SURFACE - SEE STANDARD FLAN F -4s.io 4 - Cr PAIN. 15'- 0" MAX. SEE CONTRACT PLANS SEE NOTE 7 � SLOPE TREATMENT -• t, SEE STANDARD PLAN F41ILI0 r- GRADE BREAK 1 2.0% MAX. rrr $.39� MAX � L AMNO CURB RAMP �• i r SECTION A CALL 2 DAYS BEFORE YOU DIG 1- 800 - 424 -5555 (UNDERGROUND UTILITY LOCATIONS ARE APPROX.) (SHOWN WITH BUFFER) CEMENT CONCRETE PEDESTRIAN CURB - -- _ SEE NOTE 4 - GRADE BREAK , r' COUNTER SLOPE -• &0% MAX- 3" R. TYP. TOP OF ROADWAY ' DETECTABLE WARNING SURFACE - •; SEE STANDARD PLAN F-0.10 ►,� DEPRESSED CURB AND GUTTER - SEE NOTE 4 .� __MM ENT CONCRETE CURB ' `C AND GUTTER - SEE NOTE 4 DEPRESSED CURB AND GUTTER - SEE STANDARD PLAN F40.12 CEMENT CONCRETE CURB RAMP 'TYPE MIT - ISOMETRIC VIEW TYPE PERPENDICULAR A PAY LIMIT cuRS w►aus DETAIL O PERPENDICULAR CURB RAMP � PER WSDOT STD PLAN F- 40.15 -02 �O3 NTS BASE MAP/TOPOGRAPHY PROVIDED BY OTHERS. DCG CANNOT BE HELD LIABLE FOR ACCURACY. CONTRACTOR SHALL DAVIDO CONSULTINGGROUP, INC. FIELD VERIFY GRADES. UTILITIES, AND ALL OTHER EXISTING FEATURES AND Civil Structural Land Use CONDITIONS. IF CONDITIONS ARE NOT AS SHOWN AND /OR PLANS CANNOT BE 1 5029 Bothell Way NE, Suite 600 CONSTRUCTED AS SHOWN, CONTACT Lake Forest Park, WA 98155 DCG PRIOR TO CONSTRUCTION. _106.523.00-14 P.O. Box 1132 Freeland. WA 98249 360.331.4131 of wD A Sy, O Aim O 33723 X111 F% G /STER���j� S�ONAL ISOMETRIC VIEW TYPE PERPENDICULAR B PAY LIMIT NO. REVISION 4" PERMEABLE HMA TOP COURSE (SEE NOTE 5 BELOW) 2" CHOKER COURSE (SEE NOTE 1 BELOW) 6" DEEP CONC F TRAFFIC CURB PER DETAIL C07 6" PERMEABLE BALLAST % PASSING 1'/2" (SEE NOTE 2 BELOW) 1" 95 -100 A'/ 25 -60 4 0 -10 8 0 -5 SLOPE VARIES 75 MIN. NONWOVEN GEOTEXTILE PROPERTY METHOD � .....�.::.,.,, ,.;..;.....,, LOW PERMEABILITY NO. 30 MAX. NO. 40 MAX. BACKFILL TO D 4491 0.02 SEC -1 MIN. 0.10 SEC -1 MIN. NATIVE SOIL D 4632 \ \ \ 160 LB MIN. \ \ MACHINE AND X- MACHINE DIRECTION GRAB FAILURE STRAIN, IN MACHINE D 4632 < 50% 2:50% CONSTRUCTION GEOTEXTILE SUBGRADE TO BE PROTECTED FROM FOR SEPARATION, NON -WOVEN COMPACTION DURING CONSTRUCTION SECURE TO CONC CURB; WHERE NO FROM HEAVY EQUIPMENT WHEREVER CURB, FOLD OVER WASHED DRAIN ROCK POSSIBLE (SEE NOTE 3 BELOW) (SEE NOTE 4 BELOW) PERMEABLE PAVEMENT CROSS - SECTION FOR LIGHT LOADS NTS CO3 k,.& 1305 PERMEABLE PAVEMENT NOTES. 1. CHOKER COURSE FOR PERVIOUS HMA CHOKER COURSE FOR PERVIOUS HMA SHALL BE 3/8- TO 3/4 -INCH UNIFORMLY GRADED STONE WITH A WASH LOSS OF NO MORE THAN 0.5% ( AASHTO SIZE NUMBER 57) AND SHALL MEET THE FOLLOWING REQUIREMENTS FOR GRADING AND QUALITY: SIEVE SIZE % PASSING 1'/2" 100 1" 95 -100 ' /z" 25 -60 4 0 -10 8 0 -5 AGGREGATE STORAGE LAYER - 6" DEPTH MIN. (GRADATION FROM WSDOT SPECS) 2. PERMEABLE BALLAST PERMEABLE BALLAST SHALL MEET THE REQUIREMENTS OF SECTION 9- 03.9(1) FOR BALLAST EXCEPT FOR THE FOLLOWING SPECIAL REQUIREMENTS. THE GRADING AND QUALITY REQUIREMENTS ARE: SIEVE SIZE % PASSING 2'/2" 100 2" 65 -100 3/4" 40 -80 NO. 4 5 MAX. NO. 100 0 -5 % FRACTURE 75 MIN. ALL PERCENTAGES ARE BY WEIGHT. 3.SUBGRADE FOR PAVEMENT THE CONTRACTOR SHALL NOT STOCKPILE MATERIALS WITHIN THE PERVIOUS PAVEMENT AREAS EXCEPT THAT IF THE CONTRACTOR CHOOSES TO STOCKPILE MATERIALS WITHIN THE PERVIOUS PAVEMENT AREA THE AREA SHALL NOT BE GRADED BELOW THE FINISH GRADE LEAVING A MINIMUM OF 15" OF NATIVE MATERIAL IN PLACE UNTIL IMMEDIATELY PRIOR TO CONSTRUCTION OF THE PERVIOUS PAVEMENT SYSTEM. TEMPORARY CONSTRUCTION ENTRANCE MATERIALS, IF LOCATED IN THE PERVIOUS PAVEMENT AREA, SHALL BE FULLY REMOVED PRIOR TO SUBGRADE PREPARATION. CONSTRUCTION EQUIPMENT SHALL BE PROHIBITED FROM PERVIOUS PAVEMENT AREAS UNLESS THE SUBGRADE IS PROTECTED AS SPECIFIED FOR STOCKPILING IN THE PERVIOUS AREA OR THE GEOTEXTILE AND FULL DEPTH OF BASE ROCK ARE IN PLACE PER THE PLANS. IF THE ENGINEER DETERMINES THAT THE PERVIOUS PAVEMENT BASE ROCK HAS BEEN CONTAMINATED OR DAMAGED BY CONSTRUCTION EQUIPMENT THE CONTRACTOR SHALL REMOVE AND REPLACE A DEPTH OF BASE ROCK AS DIRECTED BY THE ENGINEER AND NO ADDITIONAL PAYMENT WILL BE MADE FOR THE REMOVED AND REPLACED BASE ROCK. THE ENGINEER WILL INSPECT THE SUBGRADE AND UNLESS OTHERWISE DIRECTED BY THE ENGINEER THE CONTRACTOR SHALL REMOVE ANY ACCUMULATION OF FINE MATERIAL, SCARIFY THE THE SOIL TO A MINIMUM DEPTH OF 6 INCHES, AND COMPACT THE SUBGRADE TO THE APPROPRIATE COMPACTION. SURVEYED: DESIGNED: TIM GABELEIN DRAWN: NATHAN DAVIS CHECKED: ERIK DAVIDO BY DATE APPR APPROVM. ERIK DAVIDO R- 380908 SCALE: AS NOTED ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL: NAVD 1988 HORIZONTAL• MD 1983/1991 DATUM 6" PERMEABLE HMA TOP COURSE (SEE NOTE 5 BELOW) 2" CHOKER COURSE (SEE NOTE 1 BELOW) 12" PERMEABLE BALLAST (SEE NOTE 2 BELOW) x �X, X \\ 6" DEEP CONC F TRAFFIC CURB PER DETAIL �O7 R SLOPE VARIES LOW PERMEABILITY \":: "1:; • BACKFILL TO _ NATIVE SOIL CONSTRUCTION GEOTEXTILE SUBGRADE TO BE PROTECTED FROM FOR SEPARATION, NON -WOVEN COMPACTION DURING CONSTRUCTION) SECURE TO CONC CURB: WHERE NO FROM HEAVY EQUIPMENT WHEREVER CURB. FOLD OVER WASHED DRAIN ROCK POSSIBLE (SEE NOTE 3 BELOW) (SEE NOTE 4 BELOW) PERMEABLE PAVEMENT CROSS - SECTION FOR HEAVY LOADS L2 NTS CO3 & C05 4. GEOTEXTILE FOR SEPARATION OR SOIL STABILIZATION 5. PERVIOUS HOT MIX ASPHALT MIX DESIGN - PRIOR TO THE PRODUCTION OF PHMA, THE CONTRACTOR SHALL DETERMINE A DESIGN a. GENERAL AGGREGATE STRUCTURE AND ASPHALT BINDER CONTENT IN ACCORDANCE WITH WSDOT STANDARD OPERATING PROCEDURE 732. ONCE THE DESIGN AGGREGATE STRUCTURE AND ASPHALT BINDER CONTENT HAVE BEEN DETERMINED, THE CONTRACTOR SHALL SUBMIT THE PHMA MIX DESIGN ON DOT FORM 350 -042 DEMONSTRATING THE DESIGN MEETS THE REQUIREMENTS OF SECTIONS 9- 03.8(2) AND 9- 03.8(6) OF THE WSDOT STANDARD SPECIFICATIONS. VERIFICATION OF THE MIX DESIGN BY THE CONTRACTING AGENCY IS NOT NEEDED. b. THE MIX DESIGN WILL BE THE INITIAL JOB MIX FORMULA (JMF) FOR THE CLASS OF MIX. ANY ADDITIONAL ADJUSTMENTS TO THE JMF WILL REQUIRE THE APPROVAL OF THE PROJECT ENGINEER AND MAY BE MADE PER SECTION 9- 03.8(7) OF THE WSDOT STANDARD SPECIFICATIONS. c. NON STATISTICAL EVALUATION - NON STATISTICAL ACCEPTANCE WILL APPLY TO ALL PHMA NOT DESIGNATED AS COMMERCIAL PHMA IN THE CONTRACT DOCUMENTS. NON STATISTICAL ACCEPTANCE TESTING WILL BE CONDUCTED AS OUTLINED IN 5- 04.3(8) A OF THE WSDOT STANDARD SPECIFICATIONS. d. COMMERCIAL EVALUATION. WHERE COMMERCIAL PHMA IS ALLOWED IT CAN BE ACCEPTED BY A MANUFACTURER'S CERTIFICATE OF COMPLIANCE STATING THE MATERIAL MEETS THE REQUIREMENTS IN THE CONTRACT. WHERE PHMA COMMERCIAL IS USED FOR THE TRAVELED WAY. A MINIMUM OF ONE ACCEPTANCE TEST TO VERIFY GRADATION, FRACTURE, SAND EQUIVALENT, AND OIL CONTENT IS REQUIRED IN ADDITION TO THE MANUFACTURER'S CERTIFICATE OF COMPLIANCE. e. HOT MIX ASPHALT (HMA) PAVING CLASS '/2" PG 70 -22, POLYMER MODIFIED, WITH 5 POUNDS OF FIBER PER TON OF ASPHALT MIX, THICKNESS AS INDICATED ON PLANS, CONFORMING TO AASHTO MP -1. PRIOR TO THE PRODUCTION OF PHMA THE CONTRACTOR SHALL DETERMINE A DESIGN AGGREGATE STRUCTURE AND ASPHALT BINDER CONTENT IN ACCORDANCE WITH NAPA INFORMATION SERIES 131 APPENDIX A. THE PERCENT ASPHALT BINDER IN THE PHMA SHALL BE 6.0 TO 6.5 PERCENT BY DRY WEIGHT OF MIX. ACCEPTANCE SAMPLING AND TESTING - PHMA MIXTURE a. GENERAL - ACCEPTANCE OF PHMA SHALL BE AS PROVIDED UNDER NON - STATISTICAL OR COMMERCIAL EVALUATION. SAMPLING OF PHMA FOR NON - STATISTICAL EVALUATION WILL BE AS DISCUSSED IN THE WSDOT STANDARD SPECIFICATIONS, SECTION 5- 04.3(8) A. SECTIONS 3 THROUGH 6. COMMERCIAL EVALUATION WILL BE USED FOR COMMERCIAL HMA AND OTHER CLASSES OF HMA FOR AMOUNTS LESS THAN 2500 TONS IN ANY APPLICATION. TESTING BEYOND THAT SPECIFIED IN 5- 04.3(7) A, ITEM 3 FOR COMMERCIAL HMA WILL BE AT THE DISCRETION OF THE ENGINEER. b. AGGREGATES - THE ACCEPTANCE CRITERIA FOR AGGREGATE PROPERTIES OF SAND EQUIVALENT, VOIDS IN MINERAL AGGREGATE (VMA), FRACTURE AND GRADATION WILL BE THEIR CONFORMANCE TO THE REQUIREMENTS OF SECTION 9- 03.8(2) THE WSDOT STANDARD SPECIFICATION. PHMA DEVIATION NO. 4 SIEVE AND LARGER GEOTEXTILE PROPERTY REQUIREMENTS NO. 6 SIEVE TO NO. 8 SIEVE ASTM SEPARATION SOIL STABILIZATION ASPHALT BINDER % TEST _- ^- 'T= 77 :r WOVEN I NONWOVEN WOVEN NONWOVEN GEOTEXTILE PROPERTY METHOD AOS D 4751 NO. 30 MAX. NO. 40 MAX. WATER PERMITTIVITY D 4491 0.02 SEC -1 MIN. 0.10 SEC -1 MIN. GRAB TENSILE STRENGTH, IN D 4632 250 LB MIN. 160 LB MIN. 315 LB MIN. 200 LB MIN. MACHINE AND X- MACHINE DIRECTION GRAB FAILURE STRAIN, IN MACHINE D 4632 < 50% 2:50% < 50% >_ 50% AND X- MACHINE DIRECTION SEAM BREAKING STRENGTH D 4632 220 LB MIN. 140 LB MIN. 270 LB MIN. 180 LB MIN. PUNCTURE RESISTANCE D 6241 495 LB MIN. 310 LB MIN. 620 LB MIN. 430 LB MIN. TEAR STRENGTH, IN MACHINE AND D 4533 80 LB MIN. 50 LB MIN. 112 LB MIN. 79 LB MIN. X- MACHINE DIRECTION ULTRAVIOLET (UV) RADIATION 50% STRENGTH RETAINED MIN., AFTER 500 HOURS IN STABILITY D 4355 XENON ARC DEVICE 5. PERVIOUS HOT MIX ASPHALT MIX DESIGN - PRIOR TO THE PRODUCTION OF PHMA, THE CONTRACTOR SHALL DETERMINE A DESIGN a. GENERAL AGGREGATE STRUCTURE AND ASPHALT BINDER CONTENT IN ACCORDANCE WITH WSDOT STANDARD OPERATING PROCEDURE 732. ONCE THE DESIGN AGGREGATE STRUCTURE AND ASPHALT BINDER CONTENT HAVE BEEN DETERMINED, THE CONTRACTOR SHALL SUBMIT THE PHMA MIX DESIGN ON DOT FORM 350 -042 DEMONSTRATING THE DESIGN MEETS THE REQUIREMENTS OF SECTIONS 9- 03.8(2) AND 9- 03.8(6) OF THE WSDOT STANDARD SPECIFICATIONS. VERIFICATION OF THE MIX DESIGN BY THE CONTRACTING AGENCY IS NOT NEEDED. b. THE MIX DESIGN WILL BE THE INITIAL JOB MIX FORMULA (JMF) FOR THE CLASS OF MIX. ANY ADDITIONAL ADJUSTMENTS TO THE JMF WILL REQUIRE THE APPROVAL OF THE PROJECT ENGINEER AND MAY BE MADE PER SECTION 9- 03.8(7) OF THE WSDOT STANDARD SPECIFICATIONS. c. NON STATISTICAL EVALUATION - NON STATISTICAL ACCEPTANCE WILL APPLY TO ALL PHMA NOT DESIGNATED AS COMMERCIAL PHMA IN THE CONTRACT DOCUMENTS. NON STATISTICAL ACCEPTANCE TESTING WILL BE CONDUCTED AS OUTLINED IN 5- 04.3(8) A OF THE WSDOT STANDARD SPECIFICATIONS. d. COMMERCIAL EVALUATION. WHERE COMMERCIAL PHMA IS ALLOWED IT CAN BE ACCEPTED BY A MANUFACTURER'S CERTIFICATE OF COMPLIANCE STATING THE MATERIAL MEETS THE REQUIREMENTS IN THE CONTRACT. WHERE PHMA COMMERCIAL IS USED FOR THE TRAVELED WAY. A MINIMUM OF ONE ACCEPTANCE TEST TO VERIFY GRADATION, FRACTURE, SAND EQUIVALENT, AND OIL CONTENT IS REQUIRED IN ADDITION TO THE MANUFACTURER'S CERTIFICATE OF COMPLIANCE. e. HOT MIX ASPHALT (HMA) PAVING CLASS '/2" PG 70 -22, POLYMER MODIFIED, WITH 5 POUNDS OF FIBER PER TON OF ASPHALT MIX, THICKNESS AS INDICATED ON PLANS, CONFORMING TO AASHTO MP -1. PRIOR TO THE PRODUCTION OF PHMA THE CONTRACTOR SHALL DETERMINE A DESIGN AGGREGATE STRUCTURE AND ASPHALT BINDER CONTENT IN ACCORDANCE WITH NAPA INFORMATION SERIES 131 APPENDIX A. THE PERCENT ASPHALT BINDER IN THE PHMA SHALL BE 6.0 TO 6.5 PERCENT BY DRY WEIGHT OF MIX. ACCEPTANCE SAMPLING AND TESTING - PHMA MIXTURE a. GENERAL - ACCEPTANCE OF PHMA SHALL BE AS PROVIDED UNDER NON - STATISTICAL OR COMMERCIAL EVALUATION. SAMPLING OF PHMA FOR NON - STATISTICAL EVALUATION WILL BE AS DISCUSSED IN THE WSDOT STANDARD SPECIFICATIONS, SECTION 5- 04.3(8) A. SECTIONS 3 THROUGH 6. COMMERCIAL EVALUATION WILL BE USED FOR COMMERCIAL HMA AND OTHER CLASSES OF HMA FOR AMOUNTS LESS THAN 2500 TONS IN ANY APPLICATION. TESTING BEYOND THAT SPECIFIED IN 5- 04.3(7) A, ITEM 3 FOR COMMERCIAL HMA WILL BE AT THE DISCRETION OF THE ENGINEER. b. AGGREGATES - THE ACCEPTANCE CRITERIA FOR AGGREGATE PROPERTIES OF SAND EQUIVALENT, VOIDS IN MINERAL AGGREGATE (VMA), FRACTURE AND GRADATION WILL BE THEIR CONFORMANCE TO THE REQUIREMENTS OF SECTION 9- 03.8(2) THE WSDOT STANDARD SPECIFICATION. PHMA DEVIATION NO. 4 SIEVE AND LARGER PERCENT PASSING ±4.0 NO. 6 SIEVE TO NO. 8 SIEVE PERCENT PASSING ±2.0 NO. 100 SIEVE TO NO. 200 SIEVE PERCENT PASSING ±0.4 ASPHALT BINDER % PERCENT BINDER CONTENT ±0.5 IN COMPLIANCE WITH CITY OF RENTON TANDAR S BY: Date: BY: Date: BY. Date: BY. Date: CITY OF SHUTTLE EXPRESS - RENTON PARKING LOT 2/10/2015 800 SW 16TH ST RENTON P °°" RENTON, WA NO- Planning/Building/Public Works Dept. C09 DETAILS 9 °F= 9 T L �5 y x C 2. 1 _- ^- 'T= 77 :r f i x- -Z m z .. O D T x �^ T -3 J J �Z zJ z rn D 0 M a z c� z C 3 m M M x 77 -- _- ^- 'T= 77 :r x- z .. O BERM v v v v vvv vYv�iJb vvv. v v v v v- v v v\i% v v v v: vvv av�v v v v v ,v . v^ v v 7 c v v c v v v v v_� v; v v v v v v v c v v c v v v v v V177 v 7 v ^v c vv ^v v^ c^ v v v a v c^ v c^ v vvv v v v v: v a v v vvv ^ v v^ c v v v -v v v v ♦dr+ v " v �vyZv v c vvvcv v e c a vi a r^ v v v . v 7 7 v 7 v v v v q v v v v v v 77 c cv v v v vsv v c v v U vvv v. v v, v. v v. v v� v: v v c v v v 7 �►� i , v ` o �7� 15' WIDTH PARTIALLY SIGHT OBSCURING LANDSCAPED VISUAL BARRIER •ry��'i 7� � � u� l.. A •••••••• ice► �I mim cm! xv, EXISTING LAW PRESERVE AND PROTECT EXISTING TREES RESTORE, LAWN ■ N ■ W 'Z V W S s� v •a..;� ..� v�, r PLANT SCHEDULE DROUGHT TOLERANT ONCE SYMBOL QTY BOTANICAL NAME COMMON NAME SIZE CONDITION SPACING COMMENTS ESTABLISHED EVERGREEN TREES 3 7 MELANCHIERX AUTUMN BRILLIANCE 2" B &B/ AS SHOWN 2 TO 4 STEMS YES NO 0 GRANDIFLORA 'AUTUMN SERVICEBERRY CONTAINER BRILLIANCE' 5 CALOCEDRUS DECURRENS INCENSE CEDAR 7 GINKGO BILOBA AUTUMN AUTUMN GOLD GOLD' MAIDENHAIR TREE 4 QUERCUS COCCINEA SCARLET OAK 6' -8' B &B/ AS SHOWN YES YES CONTAINER 2" B &B/ AS SHOWN YES NO CONTAINER 2" B &B/ AS SHOWN YES NO CONTAINER ■ ■ ■ ■ ■ J ■w �C/) Li W cn W z U ■Q 1. LANDSCAPING SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF THE AMERICAN NURSERY AND LANDSCAPE ASSOCIATION (THE A.N.L.A. STANDARD) AND THE REQUIREMENTS OF THE CITY OF RENTON. 2. LAYOUT IS DIAGRAMMATIC AND MAY REQUIRE FIELD ADJUSTMENT PER DIRECTION OF THE OWNER'S REPRESENTATIVE. ANY DISCREPANCIES IN THE PLANS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE OWNER'S REPRESENTATIVE BEFORE WORK PROCEEDS FURTHER. 3. DO NOT PLACE, DIG, OR TILL SOIL WHEN THE GROUND OR TOPSOIL IS FROZEN OR EXCESSIVELY WET. 4. SOIL PREPARATION: PLACE 6 INCHES OF CEDAR GROVE VEGETABLE GARDEN MIX TOPSOIL OVER SUBGRADES IN ALL PLANTING AREAS AND TILL INTO TOP 12 INCHES OF SUBGRADE. PLACE AN ADDITIONAL 6 INCHES OF CEDAR GROVE VEGETABLE GARDEN MIX TOPSOIL AS A TOP DRESSING OVER AMENDED SUBGRADE. REMOVE ALL ROCKS, ROOTS, VEGETATION, AND DEBRIS LARGER THAN 1 INCH AND LIGHTLY COMPACT WITH A ROLLER. ADD ADDITIONAL CEDAR GROVE VEGETABLE GARDEN MIX TOPSOIL IF REQUIRED TO MEET FINISH ELEVATIONS. 5. FINISH GRADING: FINISH ELEVATION SHALL BE DEFINED AS 3 INCHES BELOW CURBS, WALKS, AND /OR OTHER ADJACENT HARDSCAPE FOR ALL LANDSCAPE AREAS. FINISH ELEVATION REFERS TO GRADES PRIOR TO INSTALLATION OF MULCH. 6. GRADE ALL LANDSCAPE AREAS TO PROVIDE POSITIVE DRAINAGE. 7. RAKE PREPARED SOIL SMOOTH AND FREE FROM ALL SOIL LUMPS, ROCKS, STICKS, AND OTHER DELETERIOUS MATERIALS OVER ONE INCH IN DIAMETER. 8. AT TIME OF PLANTING, SUPPLEMENT ALL NEW PLANT MATERIALS WITH MYCOAPPLY® MYCORRHIZAE INOCULANT. MIX AND APPLY PER THE MANUFACTURER'S RECOMMENDATIONS. 9. PROVIDE AND USE "OSMOCOTE" 14 -14 -14 FERTILIZER PELLETS AROUND ALL TREES, SHRUBS AND GROUNDCOVER AS SPECIFIED BY THE MANUFACTURER. 10. REMOVE PLATFORM WIRE AND SURPLUS BINDING FROM THE TOP AND SIDES OF BALLS AND LOOSEN BURLAP AT THE TOP OF THE BALLS ONLY. DO NOT REMOVE BURLAP FROM UNDER ROOT BALLS. 11. PLANT TREES AND SHRUBS UPRIGHT AND FACE TO GIVE THE BEST APPEARANCE OR RELATIONSHIP TO ADJACENT ROADWAY AND EXISTING PLANTS. 12. INSTALL ONE TREE STAKE TO THE WEST SIDE OF EACH TREE TO PROTECT AGAINST PREVAILING WINDS. 13. AFTER PLANTING, COVER ALL AREAS WITH THREE (3) INCHES OF ARBORIST WOODCHIP MULCH, AVAILABLE FROM LOCAL ARBORISTS, CONSISTING OF MAX 1" SIZE WOOD CHIPS FROM WHOLE TREES. FEATHER MULCH TO THE BASE OF THE PLANT AND 1 INCH BELOW THE TOP OF JUNCTION AND VALVE BOXES, CURBS, AND PAVEMENT EDGES. KEEP PLANT CROWNS FREE OF MULCH. PLANT SCHEDULE CONTINUED SHRUBS REQUIRED LANDSCAPE CALCULATION INTERIOR PARKING LOT LANDSCAPING REQUIRED PER 4- 4 -070.F.6.b: 15 SF PER PARKING STALL WHEN FEWER THAN 50 STALLS PROVIDED NUMBER OF REQUIRED INTERIOR INTERIOR PARKING LOT STALLS PARKING LOT LANDSCAPING LANDSCAPING PROVIDED 27 405 SF 675 SF TREES REQUIRED PER 4- 4- 070.H: PERIMETER PARKING LOT LANDSCAPING: ONE T REE REQUIRED PER T HIRTY LINEAL FEET OF ST REET FRONTAGE STREET REQUIRED EXISTING NEW TREES TOTAL FRONTAGE TREES TREES PROVIDED PROVIDED 430' 14 7 7 14 INTERIOR PARKING LOT LANDSCAPING: ONE TREE REQUIRED PER SIX PARKING SPACES NUMBER OF REQUIRED EXISTING NEWTREES TOTAL SPACES T REES T REES PROVIDED PROVIDED 27 5 0 6 6 STREET TREES (PROVIDED IN THE FRONT YARD TO AVOID CONFLICT WITH SEWER LINE) NUMBER OF TREES REQUIRED: 1 MINIMUM, MEDIUM OR LARGE TREES SPACED 50' -60' O.C. NUMBER OF TREES PROVIDED: 4 TOTAL NEW TREES REQUIRED TOTAL NEW TREES PROVIDED 13 23 SHRUBS REQUIRED PER 4- 4- 070.H: SHRUBS AT THE MINIMUM RATE OF ONE PER TWENTY (20) SQUARE FEETOF LANDSCAPED AREA LANDSCAPED AREA SHRUBS SHRUBS PROVIDED REQUIRED Q 9,695 SF 485 488 TREE REPLACEMENT CALCULATION ALL OWED TREE REMO VAL PER 4 -4 -130. C. 9 NO MORE THAT SIX (6) TREES REMOVED IN ANYTWELVE (12) MONTH PERIOD FROM A PROPERTY THIRTY FIVE THOUSAND (35,000) SQUARE FEET AND GREATER IN SIZE. PROPERTY TREES REMOVED REPLACEMENT SIZE TREES REQUIRED 143,887 SF 2 0 C +S 37 CORNUS STOLONIFERA ARCTIC FIRE DOGWOOD 2 GAL. CONTAINER AS SHOWN YES NO ARCTIC FIRE' 3 P +L 156 PRUNUS LAUROCERASUS MOUNT VERNON 2 GAL. CONTAINER AS SHOWN YES YES MOUNT VERNON' ENGLISH LAUREL 150 ROSA MEIJOCOS'PINK PINK DRIFT® ROSE 2 GAL. CONTAINER AS SHOWN YES SEMI - EVERGREEN DRIFT V V+0 19 VACCINIUM OVA TUM T HUDERBIRD 2 GAL. CONTAINER AS SHOWN YES YES 'THUNDERBIRD' EVERGREEN V +p 126 VIBURNUM DAVIDII DAVID VIBURNUM 2 GAL. CONTAINER AS SHOWN YES YES GROUNDCOVERS e `' � ' ` -7 v 1330 ARCTOSTAPHYLOS UVA -URSI VANCOUVER JADE 4" POT CONTAINER 18" 0. C. 7 7 YES YES t J v ; � 'VANCOUVER JADE' KINNIKINNICK 1220 FRAGARIA CHILOENSIS LIPSTICK COASTAL 4" POT CONTAINER 18" O.C. YES YES - 'LIPSTICK STRAWBERRY 100 NARCISSUS 'ICE FOLLIES' ICE FOLLIES DAFFODIL 14cm BULB PER PLAN YES N/A 1430 RUBUS CALCYNOIDES EMERALD CARPET 4" POT CONTAINER 18" O.C. YES YES 'EMERALD CARPET CREEPING RASPBERRY 3 R- 380909 IN COMPLIANCE WITH CITY OF RENTON STANDARDS BY: � Date: BY: Date: BY: Date: BY: Date: SCALE IN FEET 10 0 10 20 Z3 Know what's below. 0811 before you dig. a a C 0 �x c 2 4 C Z < Y_ 3: J < w Z ►— p a- = U� J� ZZ U cn _ 0O W C D o Z�Z < �� V) CL 0 O _ m Z < LL_ Cn Z � �LU �O� V)C� J W� W� � m � � CL a- < U XV) Wp U) LiJ 0 Q c� Q E-- Z, Z U) W W� 3 0 Y a �— PROJECT MER MANAGER: D DESIGNED a w Z DRAWN MER /RL BY: CHECKED w BY: SCALE: SCALE AS SHOWN DATE: REV. SHEET 01/12/2015 3 > �o ov > < U �o0D LL_ �_Q_ 0 (D 0 wZZ to �_ �_ ZZ Q J J 0 Zww Z j j w w CL cr- CC m Q V_ Iii 1111- LLJ �- .- O O N O N Q N D L0 N 00 C)o 0 r- N M Z T. x a L.Li z W 0 G7 Z w C J Z m + < m w Q_ < D W Cn o (� Z r4 CA l z 4 <�. r J < Ec. -- x i x Z i Know what's below. 0811 before you dig. a SHEET NUMBER LS1 � C 0 �x c Z < Y_ 3: J < w Z a- = U� J� ZZ U cn < 0O W C I Z�Z < �� V) CL 0 O Z < LL_ Cn Z � z< �O� V)C� J W� W� � a- 00 � � CL a- < U XV) Wp U) LiJ 0 Q J 00 J E-- U W W� 3 0 0 a PROJECT MER MANAGER: DESIGNED MER B Y: DRAWN MER /RL BY: CHECKED RL BY: SCALE: SCALE AS SHOWN DATE: REV. SHEET 01/12/2015 3 OF SHEET NUMBER LS1 � C f �x c z C v C I C n EX. TREE TO J _ ■ BE REMOVED _Lj v z ■ J 0 ■ J < MER DESIGNED ■ ■ ■ ■ BERN ■ �n W LLJ LAJCn ■ (W V / W Z ff EU- ■ NOTE: OFFSET GROJNDCOVERS 9" FROM CURB;. WALLS, LIGHT FOUNDATIONS, AND ROOTBALLS OF TREES AND SHRUBS. 3" DEPTH ARBORIST WOODCHIP MULCH, TYPICAL. KEEP AWAY FROM PLANT CROWN. 9" OFFSET, TYPICAL . UNDISTURBED SUBGRADE TYPICAL GROUNDCOVER PLANTED AT NURSERY LEVEL 2% MIN. .. -. 6• _ —___= 1 =I I I =I I I =1 I MI I El 11 =1 -I 11=1 11 =1 I I =1 I I =111 =1 I I =1 11=1 I I =111 =1 1 =1 11 =1 I MI 11 =1 11=1 11 =1 11=I 11=1 I MI 11 1=1 11 =1 I I =1 11 =1 11=1 11 =1 I I =I 11=1 11= =1 I MI 11=1 I I =1 11 =1 11=1 I I =1 I = — 1 =1 11-1 1= TYPICAL GROUNDCOVER PLANTING DETAIL NOT TO SCALE s GROUNDCOVER AT TIME OF PLANTING, TYPICAL 18" TYPIGAL TYPICAL GROUNDCOVER SPACING DETAIL NOT TO SCALE FINISH GRADE 6" DEPTH CEDAR GROVE GARDEN MIX TOPSOIL 6" DEPTH CEDAR GROVE VEGETABLE GARDEN MIX TOPSOIL TILLED INTO THE TOP 12" OF SUBGRADE. SCARIFY SUBGRADE 1) MULCH COMPLETELY BETWEEN ALL PLANTS. 2) PLANT SO THAT TOP OF ROOT BALL IS EVEN WITH FINISHED GRADE. 3) SCARIFY SIDES OF PLANTING PITS PRIOR TO BACKFILLING. SHRUB BACKFILL PLANTING PIT WITH CEDAR GROVE VEGETABLE GARDEN MIX TOPSOIL, WATER AND TAMP TO REMOVE AIR POCKETS FINISH GRADE 6" DEPTH CEDAR GROVE GARDEN MIX TOPSOIL ; 6" CEDAR GROVE =III =111 =1 •:: s.- VEGETABLE GARDEN MIX TOPSOIL TILLED INTO THE ;j \� \� - / // / TOP 12 OF SUBGRADE. \ / \ / \ \,\ \/\ SCARIFY SUBGRADE UNDISTURBED SUBGRADE PI ANTIN(, PIT m C L A MUU I DMLL UIH. TYPICAL SHRUB PLANTING DETAIL NOT TO SCALE 3" DEPTH ARBORIST WOODCHIP MULCH. KEEP MULCH AWAY FROM TRUNK. FORM SAUCER WITH 3 HIGH CONTINUOUS RIM. NOTE: SEE SHEET LS1 FOR PLANT SCHEDULE. NOTE: 1) MULCH COMPLETELY BETWEEN ALL PLANTS. 2) STAKE TREES 5' IN HEIGHT OR GREATER. I 3) PLANT SO THAT TOP OF ROOT BALL IS EVEN WITH FINISHED GRADE. 4) COMPLETELY REMOVE ALL WIRE AND LOOSEN FABRIC ON BALLED & BURLAPPED PLANTS. 5) SCARIFY SIDES OF PLANTING PITS PRIOR TO BACKFILLING. 6' -0" PINE STAKE DRIVEN TO REFUSAL INTO UNDISTURBED SUBGRADE, MINIMUM 24" DEPTH. STAKE LOOSELY 2' ABOVE FINISH GRADE, TYPICAL BACKFILL PLANTING PIT WITH CEDAR GROVE VEGETABLE GARDEN MIX TOPSOIL, WATER AND TAMP TO REMOVE AIR POCKETS FINISH 2' GRADE i TREE -----,A I /— PLASTIC TIE 3" DEPTH ARBORIST WOODCHIP MULCH. KEEP MULCH AWAY FROM TRUNK. FORM SAUCER WITH 3" HIGH CONTINUOUS RIM. I 6" DEPTH CEDAR GROVE GARDEN ' MIX TOPSOIL = � — 6" CEDAR GROVE VEGETABLE GARDEN MIX TOPSOIL TILLED INTO ' / / \ - %� // /i�' -% // / / \, \'' 6" THE TOP 12 OF SUBGRADE. % /j� // /., SCARIFY SUBGRADE UNDISTURBED SUBGRADE PLANTING PIT DIA. 2 X ROOT BALL DIA. TYPICAL TREE PLANTING DETAIL NOT TO SCALE SCALE IN FEET 10 0 10 20 380910 0 LU Z Cn cr LLJ Z < Ln W W Z W W 0 0 cn = U > Q O U It LLJ OOw LL- �- 0- W Z� Z cn H H Leg Z Uj(5 �ww Q__ X_ cr_ m v �n Q � N N N co o \ Z N c7 IN COMPLIANCE WITH CITY OF RENTON STANDARDS BY: Date: BY: Date: BY: Date: BY: Date: U U �- J (n J < w = Z � Z 0 LL_ F Cn Z WW 0 Qf w 0 00 0 J CD Z < cn y3: =� of - < < ~ Uj O Z (D � z O Z E_ �� z W w � Q :f 0 V) I = < Cn ~ Q Cn CO J w � a' of 30. w CL Q X� U Wo 0 L1.1 00 Q J J W U W) U) W °� w 0 a PROJECT W MER DESIGNED J 0 MER + Q J Q_ MER /RL _J < W U) � VJ 0 RL Z g SCALE AS C, DATE: REV. t 01/12/2015 z of 3 a r , t!i E C - m E L� - C U �- J (n J < w = Z � Z 0 LL_ F Cn Z WW 0 Qf w 0 00 0 J CD Z < cn y3: =� of - < < ~ Uj O Z (D � z O Z E_ �� z W w � Q :f 0 V) I = < Cn ~ Q Cn CO J w � a' of 30. w CL Q X� U Wo 0 L1.1 00 Q J J W U W) U) 3 °� 0 a PROJECT MANAGER: MER DESIGNED B Y: MER DRAWN MER /RL BY: CHECKED RL BY: SCALE: SCALE AS SHOWN DATE: REV. SHEET 01/12/2015 3 of Know what's below. 0811 before you dig. SHEET NUMBER LS2 i _ C J z J D D T q TT f �K 1 _ r U z T D LEGEND 1 e% Tr ^ 1. WATER PLANTS UNTIL PLANT ESTABLISHMENT AND FOR A MINIMUM OF TWO YEARS. 2. WATER ON A 3 -DAY SCHEDULE UNLESS PRECIPITATION MEETS OR EXCEEDS AMOUNT NEEDED TO PROMOTE HEALTHY AND VIGOROUS GROWTH 3. TEMPORARY IRRIGATION PLAN IS DIAGRAMMATIC. FOLLOW MANUFACTURER'S RECOMMENDATIONS TO ENSURE ADEQUATE WATER COVERAGE. 4. WATER ZONE 2 BETWEEN THE HOURS OF 9:00 PM AND 7:00 AM TO AVOID CONFLICTS WITH VEHICULAR OR PEDESTRIAN CIRCULATION. SW 16TH STREET SPIV 16TH STREET ................. IN COMPLIANCE WITH CITY OF RENTON STA ARDS BY: ��`'' Date:3 BY: Date: BY: Date: BY: Date: R -3809 4;; SCALE IN FEET 20 0 20 40 Know what's below. Call before you dig. Uj cn 0 C7 � Z W Q d- O W W Z > Z 0 O Z ) O U c r- 1- -O w Q 0 c �O Q- }N _Z Q Q- Z Z a � Q- M 0 0 WWW oww QWIx qcr Lc) w o 0 F- N C-4 N Q v- N U') N 00 O 0 r- N m z EXISTING HOSE BIB 0 SLOW RELEASE TREE WATERING BAG W ZONE 1: WATER WITH 100' LENGTH GARDEN HOSE ol CONNECTION TO EXISTING HOSE BIBS AND SPRINKLERS, m BY HAND, AND /OR USING LOW FLOW 'SOAKER' HOSES W ZONE 2: WATER WITH 200' LENGTH GARDEN HOSE Q ~ CONNECTION TO EXISTING HOSE BIBS AND LOW FLOW 0 'SOAKER' HOSES. 1 e% Tr ^ 1. WATER PLANTS UNTIL PLANT ESTABLISHMENT AND FOR A MINIMUM OF TWO YEARS. 2. WATER ON A 3 -DAY SCHEDULE UNLESS PRECIPITATION MEETS OR EXCEEDS AMOUNT NEEDED TO PROMOTE HEALTHY AND VIGOROUS GROWTH 3. TEMPORARY IRRIGATION PLAN IS DIAGRAMMATIC. FOLLOW MANUFACTURER'S RECOMMENDATIONS TO ENSURE ADEQUATE WATER COVERAGE. 4. WATER ZONE 2 BETWEEN THE HOURS OF 9:00 PM AND 7:00 AM TO AVOID CONFLICTS WITH VEHICULAR OR PEDESTRIAN CIRCULATION. SW 16TH STREET SPIV 16TH STREET ................. IN COMPLIANCE WITH CITY OF RENTON STA ARDS BY: ��`'' Date:3 BY: Date: BY: Date: BY: Date: R -3809 4;; SCALE IN FEET 20 0 20 40 Know what's below. Call before you dig. Uj cn 0 C7 � Z W Q d- O W W Z > Z 0 O Z ) O U c r- 1- -O w Q 0 c �O Q- }N _Z Q Q- Z Z a � Q- M 0 0 WWW oww QWIx qcr Lc) w o 0 F- N C-4 N Q v- N U') N 00 O 0 r- N m z w W IN COMPLIANCE WITH CITY OF RENTON STA ARDS BY: ��`'' Date:3 BY: Date: BY: Date: BY: Date: R -3809 4;; SCALE IN FEET 20 0 20 40 Know what's below. Call before you dig. Uj cn 0 C7 � Z W Q d- O W W Z > Z 0 O Z ) O U c r- 1- -O w Q 0 c �O Q- }N _Z Q Q- Z Z a � Q- M 0 0 WWW oww QWIx qcr Lc) w o 0 F- N C-4 N Q v- N U') N 00 O 0 r- N m z V w W J m W Q ~ Z Q 0 + Q J CL J Q w q a-0 (n Z —J V) g a. J Q r, O 'J Z L� .f. Z� w Qr-z Z t. J > L� <�. Cn Z �x r j < r^ W 0 W r— E c CO a tj L <Z z V 01/12/2015 I 3 I of SHEET NUMBER IR1 0 J 0 Z Q Neol 3: w a-0 < —J V) ZZ a. J Q OW O � E-- Z L� 111-- Z� w Qr-z W af � w Q Q.,f 0 c Cn Z 0 Of W 0 W r— DC CO a a- X W O w ~ W 0 100 � W W �V) z 3 o x 0 a PROJECT MER MANAGER: DESIGNED MER BY: DRAWN BY: MER /RL CHECKED RL BY: SCALE: SCALE AS SHOWN DATE: REV. SHEET 01/12/2015 I 3 I of SHEET NUMBER IR1