S-362612
iAC13- S—"36:::) b 1 1 H. O Qi e• �\ gg0(8tL4� 1Is IAiAI, >� ONE -LINE DIAGRAM SYMBOLS PANELBOARDS, SWITCHES, AND EQUIPMENT LIGHTING FIXTURES /DEVICES ABBREVIATIONS LADDER LOGIC SYMBOL LEGEND n CIRCUIT BREAKER SERVICE ENTRANCE, SPDT - SINGLE POLE, DOUBLE THROW INDICATOR LIGHT RELAY INDICATOR LIGHT SIGNEk 01118113 XXXM( -CB SIZE & NO. OF POLES ET - ELECTRONIC TRIP SWITCHGEAR,MOTORCONTROL CENTER, OR PANELBOARD O FLUORESCENT FIXTURE D SPST - SINGLE POLE, SINGLE THROW DPST - DOUBLE POLE, SINGLE THROW RELAY A -AMBER G -GREEN nZ TR -Timed relay B BLUE R RED 123 MILL TM- THERMAL MAGNETIC BREAKER MCP - MOTOR CIRCUIT PROTECTOR SURFACE MOUNTED WALL/CEILING MOUNTED FIXTURE WP - WEATHER -PROOF GFI - GROUND FAULT INTERRUPT - - CR - Control relay y C -CLEAR W -WHITE `9t• +` m o SE- SERVICE ENTRANCE PANELBOARD P -POWER GFI - GROUND FAULT INTERRUPTER C- CONTROL J INSTRUMENTATION LIMIT SWITCH FLOAT SWITCH 1 �— FUSE FLUSHED MOUNTED EMERGENCY LIGHT WITH SELF - PC -POWER &CONTROL O LIMIT SWITCH, NORMALLY OPEN FLOAT SWITCH, NORMALLY OPEN Aoeur s� FUSED DISCONNECT SWITCH PANELBOARD ® CONTAINED BATTERY CJ - CONTROL & INSTRUMENTATION PLUG -IN CONNECTION CKT. - CIRCUIT LIMIT SW TCH FLOAT SWITCH SIGNER 01/18/13 RTM RUN TIME METER FIELD CONTROL STATION WITH NEMA REQUIREMENTS. SURFACE OR PENDANT MOUNTED O FIXTURE C.O. - CONDUIT ONLY N.L. - NIGHT LIGHT LIMIT SWITCH, NORMALLY CLOSED O �� FLOAT SWITCH, �� NORMALLY CLOSED V ® MOTOR OPERATION COUNTER N1- NEMA 1 O RECESSED FIXTURE AL. - ALUMINUM CU.- COPPER j�N3R- SSRVS - SOLID STATE NEMA3R N4 - NEMA 4 N4SS - NEMA 4 STAINLESS STEEL MD MOTION DETECTOR HOA HAND-OFF -AUTO SWITCH ETM RUN TIME METER TIME DELAY CONTACT PUSHBUTTON O TIME DELAY CONTACT, NORMALLY PUSHBUTTON, OPEN, TIME TO CLOSE NORMALLY CLOSED D*4 REDUCED VOLTAGE N4F - NEMA 4 FIBERGLASS PHOTO CONTROL CELL OC OPERATION COUNTER N8 -NEMA 6 STARTER VARIABLE FREQUENCY DRIVE N12 - NEMA 12 GASKETED EQUIPMENT MOUNTING STAND MRIL MOTOR RUN INDICATION LIGHT SFIL SEAL FAIL INDICATION LIGHT SFTR SEAL FAIL TRIP RESET OTIL OVER TEMPERATURE INDICATION LIGHT TIME DELAY CONTACT PUSHBUTTON TIME DELAY CONTACT, NORMALLY PUSHBUTTON, NORMALLY OPEN CLOSED, TIME TO OPEN O O SWITCH OUTLETS S ® STANDARD SWITCH, 20 AMP MOTOR STARTER ® 3 -WAY SWITCH,120VAC, 20 AMP S ®SWAY MOIL MOTOR OVERLOAD INDICATION LIGHT TIME DELAY CONTACT THERMOSTAT THERMOSTAT SWITCH, TIME DELAY CONTACT, NORMALLYp NORMALLY OPEN INDICATE TYPE BY LETTER INSTRUMENT METER A B MOTOR STARTER W/ OPERATOR HEATER, WATTAGE NOTED S O 3- POSITION SWITCH, 120VAC, 20 "1�\� OPEN, TIME TO OPEN � z CD AMP, LABEL SWITCH POSITION DEVICES A - HAND-OFF -AUTO ® EQUIPMENT CONNECTION HOA HOA HAND -OFF- MOTION OR PHOTO V A- AMMETER VAR - VARMETER AH - AMPERE -HOUR VARH - VARHOUR METER TIME DELAY CONTACT THERMOSTAT TIME DELAY CONTACT, NORMALLY THERMOSTAT SWITCH, ��O W S S B - OPERATIONAL COUNTER PF -POWER FACTOR W- WATTMETER CLOSED, TIME TO CLOSE NORMALLY CLOSED W C -RUN TIME METER D RUN LIGHT M SINGLE PHASE MOTOR. SINGLE -POLE DEE PILOT- LIGHTED P AM V- VOLTMETER WH - WATTHOUR METER RELAY CONTACT, NC (,� Q - E LIGHT HORSEPOWER AS NOTED S DOUBLE -POLE 2 S KEY - OPERATED k VA- VOLTAMMETER FLOWSWTCH —I+— RELAY CONTACT, INSTANTANEOUS Q Z RACEWAYLEGEND -FAIL F- EMERGENCYSTOP 100 MOTOR. O S THREE WAY 3 S LOW VOLTAGE LV CHANGE O FLOWSWITCH, NORMALLY OPEN RELAY CONTACT, NO J O VJ 5 (F PLM LEGEND OK KIRK KEY INTERLOCK HORSEPOWER HORSEPOWER AS S FOUR WAY S MASTER � � W � LU 4 M P PROPOSED POWER 1z W POWER TRANSFORMER NOTED HP SINGLE PHASE MOTOR. S DIMMER D ❑� PUSHBUTTON TEL PROPOSED TELEPHONE PRESSURE SWITCH FLOWSWITCH Z Z ^^ CONTROL POWER TRANSFORMER q HORSEPOWER AS NOTED >EU+ PROPOSED INSTRUMENTATION O FLOWSWITCH, PRESSURE SWITCH, NORMALLY OPEN NORMALLY CLOSED O J a FIRE SYSTEM SYMBOLS TRANSFORMER ELECTRICAL PLUG OH HEAT DETECTOR U. S SMOKE DETECTOR O F° PROPOSED FIBER OPTICS PRESSURE SWITCH V) CURRENTTRANSFORMER Eh DISCONNECT SWITCH ❑D FIRE ALARM DISPATCH STROBE ALARM NWING ORFACILITY PitDGFNO EXPOSED RACEWAY n r n PRESSURE SWITCH, i 2 POLE SWITCH F� �y NORMALLY CLOSED VOLTAGE TRANSFORMER FUSED DISCONNECT SWITCH ❑A FIRE ALARM AUDIBLEISUAL ALARM N _ _ _ _ _CONCEALED, UNDERGROUND, EMBEDDED, OR CONCRETE ENCASED RACEWAY U J W ❑F FIRE ALARM MANUAL PULL STATION J COMBINATION MOTOR E HOME RUN TO PANELBOARD OR AS � W CONTACTOR STARTER AND DISCONNECT ADDITIONAL SYMBOLS INDICATED���� Q CAPACITOR SWITCH O SOUND SYSTEM SPEAKER ( CONDUIT RUN, BROKEN AND CONTINUED SAME SHEET OR AS NOTE D 3 POLE SWITCH D Z I v SOUND SYSTEM VOLUME CONTROL � ENGINE GENERATOR FLEXIBLE CONDUIT GENERATOR CONNECTION DOORBELL I i CONDUIT RUN. HATCH MARKS INDICATE p�0 RECEPTACLE NUMBER OF CONDUCTORS VALVE SYMBOLS SOLID NEUTRAL VNI CALLOUT INDICATING CONDUIT SIZE, NUMBER AND SIZE OF WIRE. RECEPTACLES AND JUNCTION BOX SYMBOLS PILOT VALVE SOLENOID QJ CEILING JUNCTION BOX Y27 GRG 2�t12 ® TERMINAL BLOCK ISCIENTISTS WALL JUNCTION BOX CALLOUT INDICATING CONDUIT PER ENGINEERS VALVE 200 SCHEDULE GENERAL NOTES PLANNERS SURGE PROTECTION DEVICE FJ FLOOR JUNCTION BOX CONDUIT BENT UP OR TOWARD 1. THIS IS A STANDARD LEGEND. NOT ALL OF THE INFORMATION SHOWN ON THIS PAGE WILL APPEAR IN THIS SET OF PLANS. SPD SURGE PROTECTION DEVICE DUPLEX WALL RECEPTACLE, 120V IN I CHECK VALVE CONDUIT BENT DOWN OR AWAY RH2 ENGINEERING, INC. nail: rn2.com 0 01 (ALTERNATIVE) WP = WEATHERPROOF 2. THESE DRAWINGS ARE DIAGRAMMATIC ONLY; EXACT LOCATIONS OF ELECTRICAL oxii mOlroorEAn2 cam Laoo.no.e0sz G = GROUNDED 7 CAPPED CONDUIT EQUIPMENT SHALL BE DETERMINED IN THE FIELD BY THE CONTRACTOR. THE BELLJNGHAM 3co.eic.taaw GROUNDING SYSTEM SYMBOLS IG = ISOLATED GROUND I �^ CONTROL VALVE INSTALLATION OF ALL EQUIPMENT SHOWN ON THESE DRAWINGS OR DESCRIBED IN THE 454 west Horton Road GF = GROUND FAULT INTERRUPTER w SPECIFICATIONS SHALL CONFORM TO THE REQUIREMENTS SET FORTH IN THE LATEST BOTHELL °==.ss,.saso 22722 29th D,Iva SE. suite 2`0 ELECTRICAL & SIGNAL PLAN DEVICES GROUND EDITIONS OF ALL APPLICABLE CODES AND UTILITY COMPANY STANDARDS. CONTACT ELECTRICAL SITE PLAN SYMBOLS $ SV SOLENOID VALVE COIL ZS INTRUSION SWITCH — I� DOUBLE DUPLEX THE UTILITY COMPANY REPRESENTATIVES AND VERIFY THEIR REQUIREMENTS. EASE wENATCHee s e.e661B0a ,eo Simon sheet sitt s METAL PIPE GROUND SINGLE RECEPTACLE, 120V ¢ UTILITY POLE AND GUY WIRE O MOTORIZED VALVE COIL MD MOTION DETECTOR 3. NOTIFY THE ENGINEER IMMEDIATELY IF CONFLICTS IN EQUIPMENT LOCATIONS ARE e RICHLAND sos.eass,e, 114 Columbia Point o,me, suite C ■ CONNECTION POINT, EXOTHERMIC SINGLE RECEPTACLE, 208V HH MANHOLE OR HANDHOLE DISCOVERED OR IF PROBLEMS ARISE DUE TO FIELD CONDITIONS, LACK OF INFORMATION OR ANY OTHER REASON. NO PAYMENT WILL BE MADE FOR CHANGES SILVERDALE 3eo ens.7sso WELD. CADWELD OR APPROVED O MOTOR LT LEVEL TRANSDUCER WHICH HAVE NOT BEEN FAVORABLY REVIEWED BY THE ENGINEER. 2021 Nw un1,e Rd, Suite 101 EQUAL. ® DUPLEX FLOOR RECEPTACLE, 120V © BURIED POWER VAULT OR MANHOLE TACOMA O GROUND ROD SIZED PER N.E.C. SPECIAL PURPOSE WALL 0 TELEPHONE VAULT OR PEDESTAL FS FLOOD SWITCH HE HEATING ELEMENT 73"75e 621 Pacific Avenue Suite 104 USE EXOTHERMIC WELD CONNECTION AT THE GROUND ROD. VO RECEPTACLE, RATING AS NOTED Ls O O SCALE: SHOWN 0 Q CLOCK 0 FIBER OPTICS VAULT OR PEDESTAL PS LIMIT SWITCH PRESSURE SWITCH PIGTAIL, BARE COPPER, LENGTH AS REQUIRED, 8' MINIMUM. ❑TV TELEVISION on LUMINAIRE PB PANIC BUTTON PE PRESSURE ELEMENT o 1" 2" DRAWING IS NOT TO SCALE F BAR IS NOT T LONG —�— CONNECTION POINT, MECHANICAL, TELEPHONE I IE PAD -MOUNT TRANSFORMER OT THERMOSTAT SWITCH FE FLOW ELEMENT REVISED TO CONFORM ROT: 1 DC No. COMPRESSION TYPE. ROAD Zs INTRUSION SWITCH - KEY O ANALYSIS ELEMENT TO CONST ION RECORDS ENS CCA E01 MLM Q TELEPHONEIDATA WITH CABLE S=362612 °" H6`/ 11,2014 NiEEi/N�D. A RH2 E NEERING INC. DATE osNC REN • jr20 112 I9ENNIIF: LIND4K- LEGEND.DWG iAC13- S—"36:::) b 1 1