HomeMy WebLinkAboutS-362617EXPLOSION PROOF JUNCTION
BOX (TYPICAL).
TO MOTOR CONTROL CENTER /RTU
SEAL (TYPICAL)
CONDUIT (TYPICAL).
CONTRACTOR SHALL GROUT
FILL AROUND CONDUIT WITH
NON-SHRINK GROUT FOR WATER
TIGHTNESS.
1I4'x45x4" STEEL PLATE. WELD
UNISTRUT TO PLATE AND MOUNT TO
WALLS OF HANDHOLE USING (4) 318'
STAINLESS STEEL CONCRETE
ANCHORS.
CADWELD TYPE TA.
CADWELD CABLE "
CABLE TEE CONNECT
o" a
VAULT LID MARKED
'CONTROL' WITH WELD
BEAD.
TO WETWELL
GRS CONDUIT (TYPICAL).
12" MAX TYP SIZED PER PLAN.
CONDUIT TO PUMP
STARTER
PUMP MOTOR CABLE, FLOAT
CABLE, OR LEVEL TRANSMITTER
CABLE (TYPICAL)
2' UNISTRUT (TYPICAL).
SPLICE HANDHOLE ELEVATION os
NOT TO SCALE
#6 COPPER CONDUCTOR
GROUND TEE DETAIL
CADWELD TYPE ^^
#6 COPPER CONDUCTOR
NOT TO SCALE
CADWELD CABLE TO
GROUND ROD CONNECTION.
518' X 8' COPPER GROUND
ROD.
GROUND TEE DETAIL
NOT TO SCALE
SET CABLE SLEEVE AT
BOTTOM OF VAULT AND
SLOPE TOWARDS WET
WELL.
CADWELD TYPE RR.
CADWELD END CABLE TO
UPPER REBAR CONNECTION.
REBAR
SEAL (TYPICAL). J
B
O6
TO PUMP STARTER
EXPLOSION PROOF JUNCTION
BOX WITH COVER. 0- ZIGEDNEY
GUJC -100 BOX OR EQUAL _
(TYPICAL). SECURE JUNCTION
BOX TO UNISTRUT USING 114"
STAINLESS STEEL BOLTS.
0 0
RED ELECTRICAL WARNING
1 -- — — — —
0 0 1
I
1 0 0 1
I
1 0 n I
I
I
I QQQQQ I
it
PLANNER S
I
1 0 0 1
1
TAPE CENTERED OVER
RESTORE SURFACE TO EXISTING
I GLA551
SCIENTIST S
I OW/5/0N I
0 0 1
REQUIRED PER PLAN
EACH CONDUIT IN TRENCH
I AREA
I
I I
0 0 1
I I
I
QQQQ
1
(TYP)
1
1 I
1
1
I 1
RH2 ENGINEERING, INC.
I
I I
I 1
1 0 0 1
I
I 1
o 0
1 0 0
I
1 0 0
— - - - - -I
http: / /www_rh2com
0 0
T UNISTRUT. SECURE
— UNISTRUT TO HANDHOLE
WALLS.
FLEXIBLE CORD
CONNECTOR (TYPICAL)
2" PVC CABLE SLEEVE
(TYPICAL)
TO WETWELL.
(TYPICAL)
WIRE NUT ENDS TOGETHER
AND SEAL WATER TIGHT
FOR TERMINATING CABLE
TO FIELD WIRE (TYPICAL).
BELL END OF CONDUIT
(TYPICAL)
COIL MINIMUM OF 5 FEET OF
EXCESS CORD.
ELECTRICAL HANDHOLE,
UTILITY VAULT MODEL
233-LA OR EQUAL
MOTOR SPLICE HANDHOLE PLAN DETAIL
NOT TO SCALE
#6 COPPER CONDUCTOR
GROUND REBAR DETAIL
NOT TO SCALE
CADWELD TYPE XA.
^" ^MELD CABLE TO CABLE
5 CONNECTION.
#6 COPPER CONDUCTOR
(TYPICAL)
GROUND CROSS DETAIL
GROUNDING CONNECTION DETAILS
NOT TO SCALE
NOT TO SCALE
8' -0"
GRADE /
CONCRETE COVER.
CONCRETE GROUND ROD PROTECTOR 13"
DEPTH X 12' HEIGHT WITH COVER. PIPE
INC. #12R -12A & 12R -12T, OR EQUAL.
5185x8' LONG COPPER GROUND ROD.
GROUND ROD DETAIL
NOT TO SCALE
PLASTIC TUBE COUPLIN
SIZE AS NECESSAR
BUBBLER TUBE FOR BELLOWS
SEAL (TYPICAL)
GRS CONDUIT (TYPICAL).
SIZE PER PLAN.
CONDUIT TO CONTROL PANEL
EXPLOSION PROOF JUNCTION BOX
WITH COVER (TYPICAL). SECURE
TO UNISTRUT USING 1/4" J
STAINLESS STEEL BOLTS.
O- ZIGEDNEY GUJC -100 BOX OR
EQUAL FOR LEVEL TRANSDUCER.
CONDUT TO CONTROL PANEL —
0- ZIGEDNEY GUJX -100 BOX OR
EQUAL FOR FLOATS.
HUB FOR ADDITIONAL FLOATS.
FLOATS NOT SHOWN FOR CLARITY.
JACKETED CABLE FOR LEVEL TRANSDUCER
0 0
RED ELECTRICAL WARNING
I �
I
I
I
1 0 0
0 n
QQQQQ
I I
I 1
PLANNER S
I I
I 0 0
TAPE CENTERED OVER
RESTORE SURFACE TO EXISTING
I
Gl l
SCIENTIST S
ONIS."JNI 0 0
REQUIRED PER PLAN
EACH CONDUIT IN TRENCH
CONDITION OR BETTER PER PLANS
I I
I 0 0 I
1
(TYP)
1
1 I
1
RH2 ENGINEERING, INC.
I
I I
I 1
o 0
1 0 0
i —
— — — — — — — -- - - - -I
http: / /www_rh2com
0 0
ELECTRICAL HANDHOLE, UTILITY
VAULT MODEL 233 -LA OR EQUAL
FLEXIBLE CORD CONNECTOR
(TYPICAL)
r 2" PVC CABLE SLEEVE (TYPICAL)
/ TO WETWELL FOR LEV
TRANSDUCER
BELL END OF CONDUIT (TYPICAL)
TO WETWELL
FOR FLOATS
COIL MINIMUM OF 5 FEET OF
EXCESS CORD.
WIRE NUT ENDS TOGETHER AND
SEAL WATERTIGHT FOR
TERMINATING CABLE TO FIELD
WIRE (TYPICAL).
SECURE 2" UNISTRUT TO HANDHOLE WALLS.
FLOAT /LEVEL TRANSMITTER SPLICE HANDHOLE PLAN
NOT TO SCALE
SIGNED. 01/18/13
SIGNED 01/18113
W
W
zIx
a
LU
Z °C
WC)
c
Q
0 I�Iww
vl
U i
Q
Z
J
TOW
co
a
0
a
V
W
W
ONIkG—
I N E E ORS
NATIVE MATERIAL COMPACTED TO
RED ELECTRICAL WARNING
PLANNER S
95% PER ASTM D1557 OR AS
TAPE CENTERED OVER
RESTORE SURFACE TO EXISTING
SCIENTIST S
REQUIRED PER PLAN
EACH CONDUIT IN TRENCH
CONDITION OR BETTER PER PLANS
(TYP)
RH2 ENGINEERING, INC.
http: / /www_rh2com
I=
mailbox@rh2.cam 1.800.720.8052
0 W
BELLINGHAM asos,s.oaas
AD
454 West Horton Road
9'
M ul-
Z
-
BOTHELL a asls
q Z
22722 29th Drive SE, Suite 210
Z_ 0
U
6"
COVER OVER
WENATCHEE sas.ess.
�I
3^
a
300 Slman Street. Su'a 5
HIGHEST CONDUIT IN
O O
TRENCH
SAND BEDDING MATERIAL PER
RICHLAND sas.e sei
114 Columbla Point Drive, Suite C
WSDOT SPECIFICATION 9 -03.13
3^
SILVERDALE 3so.a0sJSSo
MINIMUM DEPTH BELOW
ELECTRICAL CONDUIT NUMBER AND
2021 w'nmt.e ad. Sane 107
BOTTOM OF DEEPEST CONDUIT
SIZE VARY AS PER SITE PLAN. MAINTAIN
TACOMA ." 7. oss
INSTALLED IN TRENCH
12" SPACING BETWEEN TELEMETRY
621 Pacific Avenue Suite 104
CONDUITS AND OTHER CONDUITS.
SCALE: SHOWN
TYPICAL
ELECTRICAL
TRENCH
DETAIL
NOT TO SCALE 0 1" 2"
DRAWNG IS NOT TO SCALE
IF BAR IS NOT 2" LONG
NOTE: BURY DEPTH OF CONDUIT AND HORIZONTAL SPACING SHALL Rar, 7 owc ^o.
BE CONFIRMED WITH SERVING UTILITY BEFORE CONSTRUCTION. CCA E06
REVISED TO CONFORM NLM
S3 6 2 6 17 TO CONSTRUC ON RECORDS n�re Nov it, 2014 s"`r %N0
RH2 INEERING INC. D TE +� � 172 -023 20
R>•xua: LIND— D— E— DETAILSI.DWG
$�Z
z3i
�m
NZ
Z
I as
8
-
sac
adz
a
= N.
iu2
Nz
m
n
1 V
9
no
8�
Qm
a
r
>
Fa
><
D�
vcc
r
r�
DD
30
zz