Loading...
HomeMy WebLinkAboutS-362617EXPLOSION PROOF JUNCTION BOX (TYPICAL). TO MOTOR CONTROL CENTER /RTU SEAL (TYPICAL) CONDUIT (TYPICAL). CONTRACTOR SHALL GROUT FILL AROUND CONDUIT WITH NON-SHRINK GROUT FOR WATER TIGHTNESS. 1I4'x45x4" STEEL PLATE. WELD UNISTRUT TO PLATE AND MOUNT TO WALLS OF HANDHOLE USING (4) 318' STAINLESS STEEL CONCRETE ANCHORS. CADWELD TYPE TA. CADWELD CABLE " CABLE TEE CONNECT o" a VAULT LID MARKED 'CONTROL' WITH WELD BEAD. TO WETWELL GRS CONDUIT (TYPICAL). 12" MAX TYP SIZED PER PLAN. CONDUIT TO PUMP STARTER PUMP MOTOR CABLE, FLOAT CABLE, OR LEVEL TRANSMITTER CABLE (TYPICAL) 2' UNISTRUT (TYPICAL). SPLICE HANDHOLE ELEVATION os NOT TO SCALE #6 COPPER CONDUCTOR GROUND TEE DETAIL CADWELD TYPE ^^ #6 COPPER CONDUCTOR NOT TO SCALE CADWELD CABLE TO GROUND ROD CONNECTION. 518' X 8' COPPER GROUND ROD. GROUND TEE DETAIL NOT TO SCALE SET CABLE SLEEVE AT BOTTOM OF VAULT AND SLOPE TOWARDS WET WELL. CADWELD TYPE RR. CADWELD END CABLE TO UPPER REBAR CONNECTION. REBAR SEAL (TYPICAL). J B O6 TO PUMP STARTER EXPLOSION PROOF JUNCTION BOX WITH COVER. 0- ZIGEDNEY GUJC -100 BOX OR EQUAL _ (TYPICAL). SECURE JUNCTION BOX TO UNISTRUT USING 114" STAINLESS STEEL BOLTS. 0 0 RED ELECTRICAL WARNING 1 -- — — — — 0 0 1 I 1 0 0 1 I 1 0 n I I I I QQQQQ I it PLANNER S I 1 0 0 1 1 TAPE CENTERED OVER RESTORE SURFACE TO EXISTING I GLA551 SCIENTIST S I OW/5/0N I 0 0 1 REQUIRED PER PLAN EACH CONDUIT IN TRENCH I AREA I I I 0 0 1 I I I QQQQ 1 (TYP) 1 1 I 1 1 I 1 RH2 ENGINEERING, INC. I I I I 1 1 0 0 1 I I 1 o 0 1 0 0 I 1 0 0 — - - - - -I http: / /www_rh2com 0 0 T UNISTRUT. SECURE — UNISTRUT TO HANDHOLE WALLS. FLEXIBLE CORD CONNECTOR (TYPICAL) 2" PVC CABLE SLEEVE (TYPICAL) TO WETWELL. (TYPICAL) WIRE NUT ENDS TOGETHER AND SEAL WATER TIGHT FOR TERMINATING CABLE TO FIELD WIRE (TYPICAL). BELL END OF CONDUIT (TYPICAL) COIL MINIMUM OF 5 FEET OF EXCESS CORD. ELECTRICAL HANDHOLE, UTILITY VAULT MODEL 233-LA OR EQUAL MOTOR SPLICE HANDHOLE PLAN DETAIL NOT TO SCALE #6 COPPER CONDUCTOR GROUND REBAR DETAIL NOT TO SCALE CADWELD TYPE XA. ^" ^MELD CABLE TO CABLE 5 CONNECTION. #6 COPPER CONDUCTOR (TYPICAL) GROUND CROSS DETAIL GROUNDING CONNECTION DETAILS NOT TO SCALE NOT TO SCALE 8' -0" GRADE / CONCRETE COVER. CONCRETE GROUND ROD PROTECTOR 13" DEPTH X 12' HEIGHT WITH COVER. PIPE INC. #12R -12A & 12R -12T, OR EQUAL. 5185x8' LONG COPPER GROUND ROD. GROUND ROD DETAIL NOT TO SCALE PLASTIC TUBE COUPLIN SIZE AS NECESSAR BUBBLER TUBE FOR BELLOWS SEAL (TYPICAL) GRS CONDUIT (TYPICAL). SIZE PER PLAN. CONDUIT TO CONTROL PANEL EXPLOSION PROOF JUNCTION BOX WITH COVER (TYPICAL). SECURE TO UNISTRUT USING 1/4" J STAINLESS STEEL BOLTS. O- ZIGEDNEY GUJC -100 BOX OR EQUAL FOR LEVEL TRANSDUCER. CONDUT TO CONTROL PANEL — 0- ZIGEDNEY GUJX -100 BOX OR EQUAL FOR FLOATS. HUB FOR ADDITIONAL FLOATS. FLOATS NOT SHOWN FOR CLARITY. JACKETED CABLE FOR LEVEL TRANSDUCER 0 0 RED ELECTRICAL WARNING I � I I I 1 0 0 0 n QQQQQ I I I 1 PLANNER S I I I 0 0 TAPE CENTERED OVER RESTORE SURFACE TO EXISTING I Gl l SCIENTIST S ONIS."JNI 0 0 REQUIRED PER PLAN EACH CONDUIT IN TRENCH CONDITION OR BETTER PER PLANS I I I 0 0 I 1 (TYP) 1 1 I 1 RH2 ENGINEERING, INC. I I I I 1 o 0 1 0 0 i — — — — — — — — -- - - - -I http: / /www_rh2com 0 0 ELECTRICAL HANDHOLE, UTILITY VAULT MODEL 233 -LA OR EQUAL FLEXIBLE CORD CONNECTOR (TYPICAL) r 2" PVC CABLE SLEEVE (TYPICAL) / TO WETWELL FOR LEV TRANSDUCER BELL END OF CONDUIT (TYPICAL) TO WETWELL FOR FLOATS COIL MINIMUM OF 5 FEET OF EXCESS CORD. WIRE NUT ENDS TOGETHER AND SEAL WATERTIGHT FOR TERMINATING CABLE TO FIELD WIRE (TYPICAL). SECURE 2" UNISTRUT TO HANDHOLE WALLS. FLOAT /LEVEL TRANSMITTER SPLICE HANDHOLE PLAN NOT TO SCALE SIGNED. 01/18/13 SIGNED 01/18113 W W zIx a LU Z °C WC) c Q 0 I�Iww vl U i Q Z J TOW co a 0 a V W W ONIkG— I N E E ORS NATIVE MATERIAL COMPACTED TO RED ELECTRICAL WARNING PLANNER S 95% PER ASTM D1557 OR AS TAPE CENTERED OVER RESTORE SURFACE TO EXISTING SCIENTIST S REQUIRED PER PLAN EACH CONDUIT IN TRENCH CONDITION OR BETTER PER PLANS (TYP) RH2 ENGINEERING, INC. http: / /www_rh2com I= mailbox@rh2.cam 1.800.720.8052 0 W BELLINGHAM asos,s.oaas AD 454 West Horton Road 9' M ul- Z - BOTHELL a asls q Z 22722 29th Drive SE, Suite 210 Z_ 0 U 6" COVER OVER WENATCHEE sas.ess. �I 3^ a 300 Slman Street. Su'a 5 HIGHEST CONDUIT IN O O TRENCH SAND BEDDING MATERIAL PER RICHLAND sas.e sei 114 Columbla Point Drive, Suite C WSDOT SPECIFICATION 9 -03.13 3^ SILVERDALE 3so.a0sJSSo MINIMUM DEPTH BELOW ELECTRICAL CONDUIT NUMBER AND 2021 w'nmt.e ad. Sane 107 BOTTOM OF DEEPEST CONDUIT SIZE VARY AS PER SITE PLAN. MAINTAIN TACOMA ." 7. oss INSTALLED IN TRENCH 12" SPACING BETWEEN TELEMETRY 621 Pacific Avenue Suite 104 CONDUITS AND OTHER CONDUITS. SCALE: SHOWN TYPICAL ELECTRICAL TRENCH DETAIL NOT TO SCALE 0 1" 2" DRAWNG IS NOT TO SCALE IF BAR IS NOT 2" LONG NOTE: BURY DEPTH OF CONDUIT AND HORIZONTAL SPACING SHALL Rar, 7 owc ^o. BE CONFIRMED WITH SERVING UTILITY BEFORE CONSTRUCTION. CCA E06 REVISED TO CONFORM NLM S3 6 2 6 17 TO CONSTRUC ON RECORDS n�re Nov it, 2014 s"`r %N0 RH2 INEERING INC. D TE +� � 172 -023 20 R>•xua: LIND— D— E— DETAILSI.DWG $�Z z3i �m NZ Z I as 8 - sac adz a = N. iu2 Nz m n 1 V 9 no 8� Qm a r > Fa >< D� vcc r r� DD 30 zz