HomeMy WebLinkAboutS-362716POLE -MOUNT
TRANSFORMER BY UTILITY.
POLE SHALL LOCATED AS
SHOWN ON DWG NO. E03
UTILITY POWER
ELECTRICAL EQUIPMENT AND INSTRUMENTATION SCHEDULE
ITEM
DESCRIPTION
MANUFACTURER
MODEL NO.
O
SERVICE ENTRANCE DISCONNECT SWITCH - NEMA 4, HEAVY
QTY.CATALOG NO.
HDL 26100C WITH
FLUORESCENT, LIGHT FIXTURE, 120 VAC, 4' -2' LONG, HIGH - IMPACT ACRYLIC LENS,
DUTY SERVICE RATED, 100% RATED CIRCUIT BREAKER,
SQUARED
ENCLOSURE OR EQUAL
84WTB
100 -AMP, 600VOLT,18,000 AMP INTERRUPTING RATING.
MOLDED FIBERGLASS REINFORCED POLYESTER HOUSING, (2}32W LAMPS, ENERGY
LITHONIA
BO
NOT USED THIS PLAN
32 WATT
P4
©
GENERATOR RECEPTACLE -100A, 480 VOLT, 4 -POLE, 3 -WIRE,
APpLETON
(3) - #3, (1) - #3 N, (1) - #8 GRD
P5
THREADED CAP, WEATHER PROOF.
FLUORESCENT OUTDOOR AREA LIGHT - (2)42W FLUORESCENT LAMPS, 120 VAC
MODEL ANGEL
(3)- #3,(1)- #3N,(1) -#8 GRD
P6
42 TRT
ADAPTER OR EQUAL
pQ
MANUAL TRANSFER SWITCH - NEMA 1, DOUBLE THROW,
TWR12/42TRT MVOLT PE LPI
MODEL DTU363 OR
42 WATT
NON -FUSED SAFETY SWITCH, 600V,100 AMP.
SQUARED
EQUAL
0
FLOAT SWITCH - SEE DETAIL ON DWG N0. E07
SEE SPECIFICATIONS
SEE SPECIFICATIONS
0
LEVEL TRANSMITTER
SEE SPECIFICATIONS
SEE SPECIFICATIONS
©
CHECK VALVE LIMIT SWITCHES - CONTRACTOR SHALL SELECT
SQUARED
HEAVY DUTY TYPE C,
TFL 100S RA2120 SCWA FSPB
ACTUATOR LEVER ARM BEST SUITED FOR MOUNTING
011
LASS 9007 OR EQUAL
DEDICATED SUMP PUMP RECEPTACLE
CONFIGURATION. SEE DETAIL ON DWG NO. E07.
LPI
P12
NO
TRANSIENT VOLTAGE SURGE SUPPRESSOR,'SPD'
SEE SPECIFICATIONS
SEE SPECIFICATIONS
K
VAULT FLOOD SWITCH - N.O. REED TYPE FLOAT SWITCH, 20
OMEGA MODEL
LV OR
(2)- #10,(1) - #10 GRD
VA. SEE DWG NO. E07 FOR DETAIL.
LIGHTING PANE L,'L'
AL L
EQQ UAL
0
COOLING THERMOSTAT - SPOT, 5 "F DIFFERENTIAL. RANGE
P15
T631CI103 OR
COOLING THERMOSTAT
-30 °400 "F, SET AT 75 "F. MOUNT 4' -W ABOVE FINISHED FLOOR
HONEYWELL
EQUAL
O
INTRUSION ALARM SWITCH - CONTRACTOR SHALL SELECT
2"
HEAVY DUTY TYPE C,
C2
ACTUATOR LEVER ARM BEST SUITED FOR MOUNTING
SQUARE D
CLASS 9007 OR
NYLON PULL CORD
CONFIGURATION. WIRE SWITCHES IN SERIES.
VALVE VAULT FLOOD SWITCH
EQUAL
0
ELECTRICAL SPACE HEATER - 240 VAC, 10, 3KW, WITH 24
C4
MUH03 -21 OR
TELEMETRY PANEL,'RTU-
VOLT CONTROL TRANSFORMER. MOUNT BOTTOM OF
QMARK
EQUAL
BUILDING INTRUSION ALARM SWITCH
HEATER 6'- 6' ABOVE FINISHED FLOOR.
3/4"
(2) - #14, (1) - #14 GRD
©
HEATING THERMOSTAT- DPST, 3 "F DIFFERENTIAL. RANGE
TELEMETRY PANEL, 'RTU'
T498BI512 OR
(8)- #14,(1) - #14 GRD
40 " -80 'F, SET AT 60 "F. MOUNT 4' -0' ABOVE FINISHED FLOOR
HONEYWELL
EQUAL
O
KEYSWITCH- WEATHERPROOF ENCLOSURE, MOUNT4'ABOVE
C8
1W7 -B2 -626
TELEMETRY PANEL, 'RTU'
FINISHED GRADE. CONTRACTOR SHALL COORDINATE WITH
BEST
NO SUBSTITUTE
VALVE VAULT INTRUSION SWITCH
BEST ACCESS COMPANY (KENT, WA) TO PROVIDE CORE TO
3/4"
(2) - #14, (1) - #14 GRD
Jt
MEET CITY OF RENTON STANDARDS.
FLOW METER
11/2"
OT
FLOWMETER -WITH REMOTE TRANSMITTER
SEE SPECIFICATIONS
SEE SPECIFICATIONS
LIGHTING FIXTURE SCHEDULE
480/277 - VOLT. 30
OVERHEAD PRIMARY /
SERVICE PER SERVING
UTILITY REQUIREMENTS.
GROUNDING PER
DETAIL THIS
OVERHEAD SHEET.
CONDUCTORS BY PSE
CONDUIT AND CONDUCTOR SCHEDULE
ARCUII
SOURCE
MANUFACTURER
* LAMP
TYPE
DESCRIPTION
NAME CATALOG NO.
QTY.CATALOG NO.
Al
FLUORESCENT, LIGHT FIXTURE, 120 VAC, 4' -2' LONG, HIGH - IMPACT ACRYLIC LENS,
P2
MAIN DISCONNECT
UTILITY METER
84WTB
(3)- #3,(1)- #3N,(1) -#8 GRD
MOLDED FIBERGLASS REINFORCED POLYESTER HOUSING, (2}32W LAMPS, ENERGY
LITHONIA
DM 2 32 ARDP 120
2
32 WATT
P4
SAVING BALLAST, MOUNT TO CEILING U.L. LISTED FOR DAMP LOCATIONS
MANUAL TRANSFER SWITCH, "MTS'
11/2"
(3) - #3, (1) - #3 N, (1) - #8 GRD
P5
A2
FLUORESCENT OUTDOOR AREA LIGHT - (2)42W FLUORESCENT LAMPS, 120 VAC
11/2"
(3)- #3,(1)- #3N,(1) -#8 GRD
P6
42 TRT
MOTOR SPLICE HANDHOLE
BALLAST, 9'H, 13'W, 7 3I8'D, DIE -CAST ALUMINUM HOUSING, MOUNT TOP OF FIXTURE 9'
LITHONIA
TWR12/42TRT MVOLT PE LPI
2
42 WATT
1"
ABOVE FINISHED GRADE, PHOTOCELL INCLUDED, U.L. LISTED FOR WET LOCATIONS.
PS
MOTOR SPLICE HANDHOLE
PUMP NO. 1, P -1
2"
A3
HIGH PRESSURE SODIUM OUTDOOR AREA LIGHT, 120 VAC, (1) -10OW HPS LAMP, SEE
MOTOR SPLICE HANDHOLE
PUMP NO. 2, P -2
2"
HPS
P10
MOUNTING DETAILS ON DWG NO. E07. U.L. LISTED FOR WET LOCATIONS.
LITHONIA
TFL 100S RA2120 SCWA FSPB
1
011
LIGHTING PANEL, -L'
DEDICATED SUMP PUMP RECEPTACLE
3/4"
LPI
P12
100 WATT
CONDUIT AND CONDUCTOR SCHEDULE
ARCUII
SOURCE
DESTINATION
TRADE SIZE
(QUANTITY) CONDUCTORS
P7
UTILITY TRANSFORMER
SERVICE ENTRANCE DISCONNECT
11/2"
(3)- #3,(1) -#3N
P2
MAIN DISCONNECT
UTILITY METER
11/2"
(3)- #3,(1)- #3N,(1) -#8 GRD
P3
UTILITY METER
MANUAL TRANSFER SWITCH,'MTS'
11/2"
(3) - #3, (1) - #3 N, (1) - #8 GRD
P4
GENERATOR RECEPTACLE
MANUAL TRANSFER SWITCH, "MTS'
11/2"
(3) - #3, (1) - #3 N, (1) - #8 GRD
P5
MANUAL TRANSFER SWITCH, 'NITS'
MOTOR CONTROL CENTER, 'MCC'
11/2"
(3)- #3,(1)- #3N,(1) -#8 GRD
P6
MOTOR CONTROL CENTER, 'MCC'
MOTOR SPLICE HANDHOLE
1"
(3) - #10, (1) - #10 GRD, MOTOR SENSOR CABLE
P7
MOTOR CONTROL CENTER, 'MCC'
MOTOR SPLICE HANDHOLE
1"
(3) - #10, (1) - #10 GRD, MOTOR SENSOR CABLE
PS
MOTOR SPLICE HANDHOLE
PUMP NO. 1, P -1
2"
PUMP MOTOR CABLES
P9
MOTOR SPLICE HANDHOLE
PUMP NO. 2, P -2
2"
PUMP MOTOR CABLES
P10
TELEMETRY PANEL, 'RTU"
LIGHTING PANEL, 'L'
3/4"
(2)- #12,(1) - #12 GRD
011
LIGHTING PANEL, -L'
DEDICATED SUMP PUMP RECEPTACLE
3/4"
(2) - #12, (1) - #12 GRD
P12
LIGHTING PANEL, 'L'
OUTDOOR RECEPTACLE
3/4"
(2)- #12,(1) - #12 GRD
P13
LIGHTING PANEL. 'L'
SITE LIGHT
3/4"
(2)- #10,(1) - #10 GRD
P14
LIGHTING PANE L,'L'
BUILDING HEATER
3/4"
(2)- #10,(1) - #10 GRD
P15
MOTOR CONTROL CENTER, 'MCC'
COOLING THERMOSTAT
3/4"
(2)- #12,(1) - #12 GRD
C1
WETWELL FLOATS
FLOATILEVEL TRANSMITTER SPLICE HANDHOLE
2"
MANUFACTURER FLOAT CABLES
C2
VALVE VAULT
TELEMETRY PANEL,'RTU"
1"
NYLON PULL CORD
C3
VALVE VAULT FLOOD SWITCH
VALVE VAULT JUNCTION BOX
3/4"
(2) - #14, (1) - #14 GRD
C4
FLOAT/LEVEL TRANSMITTER SPLICE HANDHOLE
TELEMETRY PANEL,'RTU-
1"
(6) - #14, (1) - #14 GRD
C5
BUILDING INTRUSION ALARM SWITCH
TELEMETRY PANEL,'RTU'
3/4"
(2) - #14, (1) - #14 GRD
C6
VALVE VAULT JUNCTION BOX
TELEMETRY PANEL, 'RTU'
3/4"
(8)- #14,(1) - #14 GRD
C7
TELEMETRY PANEL, 'RTU'
MOTOR CONTROL CENTER, 'MCC'
1114"
(30)- #14,(1) - #14 GRD
C8
INTRUSION DISABLE SWITCH
TELEMETRY PANEL, 'RTU'
3/4"
(2)- #14,(1) - #14 GRD
C9
VALVE VAULT INTRUSION SWITCH
VALVE VAULT JUNCTION BOX
3/4"
(2) - #14, (1) - #14 GRD
Jt
TELEMETRY PANEL,'RTU'
FLOW METER
11/2"
MANUFACTURER'S CABLES
J2
TELEMETRY PANEL,'RTU'
ANTENNA
2"
ANTENNA CABLE
J3
WETWELL LEVEL TRANSMITTER
FLOAT/LEVEL TRANSMITTER SPLICE HANDHOLE
1"
MANUFACTURER'S LEVEL TRANSMITTER CABLE
J4
FLOATILEVELTRANSMITTERSPLICE HANDHOLE
TELEMETRY PANEL,'RTU'
1"
MANUFACTURER'S LEVEL TRANSMITTER CABLE
OUTSIDEI
\ 10013 I
I c N TM I
100%
I O I
I I
CONDUIT AND
WEATHERHEAD FITTING
INSTALLED PER PSE
STANDARD REQUIRMENTS
I I
L
0
r ❑ I
I
MOTOR CONTROL CENTER, 48OV, 30,4W, 600A BUS, 42 KAIC WITHSTAND.
I
I
12512
TM
J480V
10KVA,
'10,3W
240/120V
15012
TM
240%120V
130/3
NEUTRAL TM
I
I
GND BUS – –
— — — — — — --
I
© I
100A,480V,30,3W PORTABLE
GENERATOR RECEPTACLE I INSIDE
ELECTRICAL NOTES
1. MAIN REVENUE METERING. METER BASE AND
PANEL SCHEDULE L
ENCLOSURE BY CONTRACTOR PER SERVING UTILITY
REQUIREMENTS. METER BY PUGET SOUND ENERGY.
2�
2. SERVICE ENTRANCE DISCONNECT SWITCH.
3�
3. SEE DWG NO. E04 FOR CONTROL LOGIC DIAGRAMS.
2
4
6
8
10
12
14
16
18
4. (2) - 518' X 8' COPPER GROUND RODS SPACED APART AS
SHOWN ON DWG NO. E03.
CIRCUIT DESCRIPTION
5. WATERPROOF SPLICE. SEE DETAIL ON DWG NO. E06
AMP
(TYPICAL).
ONE -LINE DIAGRAM
SERVICE ENTRANCE
DISCONNECT
SWITCH
#6 MIN.
S/N
GND BUS
POWER
MONITORII
PMR
PHASE
MONITOR
RELAY
- #6
BOND TO PIPE
IN VALVE
VAULT
GROUNDING
NO SCALE
0
a0
cD o
z�
�= z
J H
WET WELL
CONCRETE
REBAR MAT
UFER
CONNECTION
1MCP
MOTOR
STARTER
I
I
iMCP
!pfd
PUMP 1 PUMP 2
P -1 P -2
WCTWal-VAULFGLA551
DNl5/0N I AREA
MOTOR
STARTER
I
I
0
°w
y
0
°w
v
y
PANEL SCHEDULE L
NO.
L
LOCATION: MCC
SERVING: PUMP STATION
1
3
5
7
9
11
13
15
17
2
4
6
8
10
12
14
16
18
240/120
VOLTS 3 WIRE
CIRCUIT DESCRIPTION
KVA
AMP
AMP
KVA
CIRCUIT DESCRIPTION
OUTDOOR RECEPTACLES
0.54
20
20
0.28
SITE LIGHT
VALVE VAULT SUMP PUMP RECEPTACLE
1.20
20
20
0.28
EXTERIOR BUILDING LIGHTING
INDOOR BUILDING LIGHTING
0.08
20
20
0.50
HVAC CONTROL PANEL
TELEMETRY PANEL
0.50
20
20
0.54
INTERIOR RECEPTACLE
BUILDING HEATER
3.75
30
20
-
SPARE
2P
30
20
-
SPARE
SPARE
-
20
20
-
SPARE
SPARE
-
20
J
SPACE
SPACE
-
-
SPACE
o
CONNECTION LOAD:
7.67 KVA 31.96 AMPS
DEMAND: LIGHTING AND CONTROL LOAD
DEMAND LOAD:
6.59 KVA 27.46 AMPS
0
a0
cD o
z�
�= z
J H
WET WELL
CONCRETE
REBAR MAT
UFER
CONNECTION
1MCP
MOTOR
STARTER
I
I
iMCP
!pfd
PUMP 1 PUMP 2
P -1 P -2
WCTWal-VAULFGLA551
DNl5/0N I AREA
MOTOR
STARTER
I
I
0
°w
y
0
°w
v
y
HANDHOLE 06
SEAL -OFF,
TYPICAL
r�
_J
PROVIDE PLASTIC BUSHING
AT END OF CONDUIT, `�
TYPICAL. C' ^I
UO
1
5- 362116
RECORD DRAWING
REVISED TOO CONFORM
TO CONSTRUCTION RECORDS
RH2 E NEERING661N'CC..
A
LL
z m
K g r'n
3
W'
0
zE 3
0
J
2 8 W S
HANDHOLE 06
SEAL -OFF,
TYPICAL
r�
_J
PROVIDE PLASTIC BUSHING
AT END OF CONDUIT, `�
TYPICAL. C' ^I
UO
1
5- 362116
RECORD DRAWING
REVISED TOO CONFORM
TO CONSTRUCTION RECORDS
RH2 E NEERING661N'CC..
A
LL
3
0
0
J
�
�
U
a�
N
0
N
J
J
w
Z
0
o
U)
v
z
L
o
Lu
z
0
a
a
U
N
N
F
-
o
W
z
z
aj
�
3
3
a
6
N
a
0
o
f
�
s
ryf
¢ m�
a
V
0
Lu
Z
J
W
Q
W
J
W
m
O
a
SCALE: SHOWN
z r z
DMWM1SnA rALEWHfN
/°x'13' S- 'ale »110
E02 1 16 V21