HomeMy WebLinkAboutS-0703035
4
3
2
1
A
8
C
0
E
F
G
H
ABBREVIATIONS
TYPICAL SECTION AND
A88R
ABBREVIATE(D)
CHAM CHAMFER
DIFF
DIFFERENTIAL
FM FORCE MAIN
MATL MATERIAL
REOD
REQUIRED
DETAIL NUMBERING SYSTEM
ACT
ACTIVATED
CH CHANNEL, CABINET HEATER
DIM
DIMENSION(ED)
FWD FORWARD
MAX MAXIMUM -
RET
RETAINING)
ADPT
ADAPTER
CV CHECK VALVE, CONTROL VALVE
DISCH
0 SCHANGE(ED
FON FOUNDATION
MECH MECHANICAL
REW
RETAINING WALL
AD
ADDENDUM
CHEM CHEMICAL
DISC
DISCONNECT
FURN FURNISHED
MJ MECHANICAL JOINT
FIT
RIGHT
ADD
ADDITIONAL
CO CLEAOUT
DN
DOWN
FUT FUTURE
MED MEDIUM
RH
RIGHT HAND
ADH
ADHESIVE
CLR CLEAR, CLEARANCE
DWG
DRAWING
GALV GALVANIZED
MTL METAL
R/W
RIGHT -OF -WAY
ADJ
ADJUSTABLE
CLK CLOCK
DAB
DRILLED ANCHOR BOLT
GSKT GASKET
MIN MINIMUM
RDWY
ROADWAY
(t) SECTION TAKEN 20
AGG
AGGREGATE
COMPT COMPARTMENT
DIP
DUCTILE IRON PIPE
GV GATE VALVE
MISC MISCELLANEOUS
SAF
SAFELY
CUT ON SHEET
AMB
AMBIENT
COMP COMPLETE(TION), COMPACT(ION)
EE
EACH END, ENGINE EXHAUST
GA GAUGE
MIX MIXTURE
SCH
SCHEDULE
DIRECTION SECTION
ANSI
AMERICAN NATIONAL STANDARDS INSTITUTE
"COMPR COMPRESSOR
EF
EACH FACE, EXHAUST FAN
GEN GENERAL, GENERATOR
METRO MUNICIPALITY
OF METROPOLITAN SEATTLE
SEC
SECOND, SECONDARY
SECTION LETTER
IS LOOKING
ANC
ANCHOR
CAD COMPUTER AIDED DESIGN
EW
EACH WAY
GL GRADE LINE
WTR -C2 NONPOTABLE
CITY WATER
SECT
SECTION
AB
ANCHOR BOLT
CADD COMPUTER AIDED DESIGN & DRAFTING
EWEF
EACH WAY EACH FACE
G13V GLOBE VALVE
C2 NONPOTABLE
CITY WATER
SEW
SEWER
C
ACV
ANGLE GATE VALVE
CMA COMPUTER- MANUAL -AUTO CONTROL STATION
EA
EACH
GR GRADE
NRS NONRISING
STEM
SK
SKETCH
O
AV
ANGLE VALVE, ACID VENT
CONC CONCRETE
ESMT
EASMENT
GRTG GRATING
N NORTH
SL
SLOPE
SHEET ON WHICH '•� ,•
AVE
AVENUE
CCP CONCRETE CYLINDER PIPE
E
EAST -
GND GROUND
N/A NOT APPLICABLE
S
SOUTH
SECTION WAS TAKEN SHEET ON WHICH
ARCH
ARCHITECTURAL
CCSP CONCRETE LINED & COATED STEEL PIPE
ELL
ELBOW
GRT GROUT
NIC NOT
IN CONTRACT
SPC
SPACE
SECTION APPEARS
ASTM
AMERICAN SOCIETY FOR TESTING MATERIALS
CMU CONCRETE MASONRY UNIT
EL
ELEVATION (ELEV.)
GO GUARD
NTE NOT
TO EXCEED
SPG
SPACING
(2) SHEET 20 SHOWS THE SECTION & IS
AUX
AUXILLARY -
CNDS CONDENSATE
EMBD
EMBEDED, EMBEDMENT
HH HAND HOLE
NITS NOT
TO SCALE
SO
SQUARE
IDENTIFIED AS BELOW
AVE
AVENUE
CND CONDUIT
EMER
EMERGENCY
HS HAND STATION
O/C ON
CENTER
SS
SANITARY SEWER
AVG
AVERAGE
CONN CONNECT(OR)(ION)
ENCL
ENCLOSURE
H HAND
OHP OVERHEAD POWER
STD
STANDARD
SECTION LETTER
BPR
BACK PRESSURE REGULATOR
CONST CONSTRUCT(ION)(ED)
EC
END OF CURVE
HDWR HARDWARE
OPNG OPENING
STA
STATION
B/8
BACK TO BACK
CJ CONSTRUCTION JOINT
ENGR
ENGINEER
HDR HEADER
ORIG ORIGINAL
STG
STARTING
IDENTIFIER C
BK
BACK, BOOK
COTR CONTACTOR
ENTR
ENTER, ENTRANCE
HT HEIGHT
QA OVERALL
STL
STEEL
SCALES
BCFV
BACKFLOW CHECK VALVE
CONT CONTINUE (D), CONTROL, CONTINUOUS
EQ
EQUAL
HI HIGH
OVFL OVERFLOW
SO
STORM DRAIN
0 2
BFP
BACKFLOW PREVENTER
CONTR CONTRACT (OR)
EQUIP
EQUIPMENT
HWTR HIGH WATER
PVT PAVEMENT
STRUCT
STURCTURE
SHEET ON WHICH —SHEET ON WHICH
13AC
BACTERIA, BACTERIOLOGICAL
CORP CORPORATION -
EQD
EQUIPMENT DRAIN
HORIZ HORIZONTAL (HOR)
PERM PERMANENT
SW
SOUTHWEST
SECTION WAS TAKEN SECTION APPEARS
BALV
BALANCING VALVE
CRE CORROSION RESISTANT
EQUIV
.EQUIVALENT
IN INCH
" PHASE PHASE
TAN
TANGENT
BV
BALL VALVE
CORR CORRUGATED
EST
ESTIMATE(D)
INFO INFORMATION
PIVC PT
OF INTERSECTION OF VERTICAL CURVE
TEL
TELEPHONE
BSN
BAR SCREEN
CMP CORRUGATED METAL PIPE
EXC
EXCAVATION
ID INSIDE DIAMETER
PSI POUNDS PER SQUARE INCH
TYP
TYPICAL
(3) DETAILS ARE CROSS- REFERENCED
8M
BEAM, BENCHMARK
CTR COUNTER
EXIST
EXISTING
IF INSIDE FACE
PT POINT
UG
UNDER GROUND
IN A SIMILAR MANNER, EXCEPT
BRG
BEARING
CCW COUNTER CLOKWISE
ES
EXISTING SURFACE
INSTL INSTALL
PVC POLYVINYL
CHLORIDE
UN
UNION
THAT DETAILS ARE IDENTIFIED
4
BTD
BEARING TEMPERATURE
CSK COUNTERSINK(SUNK)
EJ
EXPANSION JOINT
INT INTERIOR, INTERNAL
PC PORTLAND CEMENT
UP
UTILITY POLE
BY NUMBER RATHER THAN BY
SCR
BEGINNING OF CURVE CENTER
CPLG COUPLING
EXT
EXTERIOR
INVEL INVERT ELEVATION (IE)
POS POSITION
V
VALVE
LETTER
BLK
BLACK, BLOCKING)
CRN CRAIN
EX
EXTRA
INV INVERT, INVERSE
PP POWER POLE
VC
VERTICAL CURVE
BF
BLIND FLANGE
XLP CROSS- LINKED POLYETHYLENE
FAB
FABRICATE(D)(TION)
JT JOINT
P/S PRE - STRESSED
VCP
VITRIFIED CLAY PIPE
80
BLOWOFF
CUFT CUBIC FEET (FOOT)
F
FACE
JF JOINT FILLER
P/C PRECAST CONCRETE
VOL
VOLUME
BC
BOLT CIRCLE, BEGIN CURVE
CFH • CUBIC FEET PER HOUR
FF
FAR FACE, FINISHED FLOOR
KIP 1,000 POUNDS
OTY QUANTITY
WIR
WATER
BOP
BOTTOM OF PIPE
CFM 'CUBIC FEET PER MINUTE
FS
FAR SIDE
LB POUND
OTR QUARTER
WF
WIDE FLANGE
BLVD
BOULEVARD
CFS CUBIC FEET PER SECOND
FED
FEDERAL
LVL LEVEL
R RADIUS. RISER
W/
WITH
BKT
BRACKET
CUIN CUBIC INCH
FIG
FIGURE
LL LOW LEVEL
RR RAILROAD
W/O
WITHOUT
BLDG
BUILDING
CUM CUBIC METER
FLT
FILTER, FLOAT
LW LOW WATER
REC RECEIVE
W
WEST
BUV
BUTTERFLY VALVE
CUYD CUBIC YARD
FCR
FINE CRUSHED ROCK
LWL LOW WATER LEVEL
RECD RECEIVE
BP
'BYPASS
CYL CYLINDER
FIN
FINISHED
LWR LOWER
RED REDUCE, REDUCER
Cl
CAST IRON
DEC DECREASING
FTNG
FITTING
MACH MACHINE
REF REFERENCE
CIP
CAST IRON PIPE
DEPT DEPARTMENT
FIX
FIXTURE
MAINT MAINTENANCE
REG REGULATE(OR)(ED)
CEM
CEMENT
DESCR DESCRIBE
FCA
FLANGE COUPLING ADAPTER
MGMT MANAGEMENT
REINF REINFORCE(ED)(ING)
CMC
CEMENT MORTAR COATED
OSGN DESIGN
FLG
FLANGE(D)
MH MANHOLE
R/C REINFORCED CONCRETE
-
CML
CEMENT MORTAR LINED
DET DETAIL
FLEX
FLEXIBLE
MAN MANUAL
RCP REINFORCED
CONCRETE PIPE
CTR
CENTER
• DIAG DIAGRAM
FL
FLOOR LINE, FLOW LINE
MFO MANUFACTURED
REBAR REINFORCING
BAR (CONCRETE)
C/C
CENTER TO CENTER
DIA" DIAMETER
FT
FOOT, FEET
MFR MANUFACTURER
RESTL REINFORCING
STEEL
CL
CENTER LINE, CHLORINE, CURRENT LIMITING
FTG
FOOTING
MFG MANUFACTURING
REM REMOVE((A(BLE)
M/L MATCH LINE
REPL
ING)
STANDARD SYMBOLS
3
NATURAL GROUND OR GRADE
U
ORNAMENTAL STREET LIGHT
OHP
OVERHEAD POWER LINE
— — — — — EDGE OF TRAVELED WAY,
INVISIBLE OR HIDDEN LINE -
T
BURIED TELEPHONE CABLE
HANDRAIL
NATURAL GROUND OR GRADE
®
VALVE
TS TRAFFIC SIGNAL CONDUIT
DRAINAGE DITCH
-
(WITH FLOW DIRECTION)
ROCK
FIRE HYDRANT
NEW FORCE MAIN,
SEWER OR WATER
OUTLINE OR BOUNDARY
CONCRETE
❑
WATER METER BOX
725 EXISTING CONTOUR
� BREAKUNE
"
PRECAST CONCRETE
❑
CATCH BASIN OR INLET
125 PROPOSED CONTOUR
(H }- -- -- GRID LINE
��+, 8'
CONSTRUCTION EASEMENT
EASMENT NO.
2
CONCRETE BLOCK
S i
0
DECIDUOUS TREE &SIZE
,
4"
CENTER LINE
O()00 00011-OC)0 WOOD POSTS
®
BRICK
j_—
EVERGREEN TREE &SIZE
= PROPERTY LINE
-( )- EXIST. LIGHT POLE
Y
®
STEEL
TD
COORDINATE CALL OUT
SECTION OR
POWER POLE
-- -
- ----
SUBDIVISION LINE
• ...... ........ • TEMPORARY CONSTRUCTION EASEMENT
CHECKER PLATE -
72'SD
STORM DRAIN & SIZE
OUTLINE EXIST.
-
INSTALLATION
PERMANENT EASEMENT BOUNDARIES
10"SS
SANITARY SEWER &SIZE
GRATE
^•
• .^ .'-
• _• r'' • CEMENT CONCRETE PAVMT
7T SS
EXIS71NO SANITARY SEWER
(NO CURB)
—
— LARGER THAN 36"
MATCH LINE
SURVEY MONUMENT OR
PERMANENT BENCH MARK
108" SS
PROPOSED SANITARY SEWER
LARGER THAN 38" — X—
X —X
—X— NEW FENCE
-
EXISTING MANHOLE
6"W
WATER MAIN & SIZE
—X— —X—
—X EXISTING FENCE
12"F
FIRE MAIN & SIZE
O
NEW MANHOLE
EXIST. CULVERT /PIPE
s
`e.
E
BURIED POWER CABLE
G
RAILROAD (DOUBLE TRACK)
SOIL BORING & DESIGNATION
RAILROAD (SINGLE TRACK)
128202
4
DESIMED:
R.B.
=`�
Municipality of Metropolitan Seattle
DAM
NOVEMBER 1992
I
tD
�* THIS BAR IS 1" ACTUAL SIZE.
Z
DRAW
SOUTH
INTERCEPTOR - PARALLEL
Nm
COF2POFiAT10N
1/412 1•
2,
T.R.B.
J.D.B.
NONE
PHASE 1
A ""F —
IF NOT I', SCALE
ACCORDINGLY.
ABBREVIATIONS, STANDARD
o
6102
W/M
4492
SYMBOLS AND LEGEND
IifYt51Ct1
BY
DATE
EXPIRES 06/14/93
,jam
n
v
r
5
4
3
2
1