Loading...
HomeMy WebLinkAboutS-0708324 3 2 A B r. n I FLOW METER VAULT. — SEE PLAN ON SHEET El 2"GRS W/8 VENDOR CABLES 2"GRS 2#12 1`12G ND (SUMP OUTLET FLOW METER CONSOLE F PLAN ON SHEET E102. = 50, 241 X 12"W X 24"D PULLING VAULT W/H20 LOADING RATED LID A A UNDERGROUND SERVICE PUGET METER AND CONS-RL)C-ION N OTCS 20/2 -cz::Zl KWH BASE ON KING COUNTY _KWH_ ENCLOSURE PROVIDE AND INSTALL NEW 20 AMP, 2 POLE CIRCUIT RNENUE F— BREAKER IN PANEL OF EXISTING RESTROORI BUILDING. METER AND ROUTE RACEWAY IN MECHANICAL SPACE. ROUTE RACEWAYS 2KWH -�-�Q 1, BASE ON 1 6 (TELEPHONE AND UNDER WALK I PULLING VAULT. I I I E To ENCLOSURE G I IN' �100/2 #1/0 #4GND — ALL SURFACES TO BE REPAIRED TO MATCH EXISTING AREAS. aLEPHONE CABLE PROVIDE MINIMUM 6 INCH SEPARATION BETWEEN POWER I METER CONSOLE PANEL) J� AND ELEPHONE RACEWAYS, T L!j L�4- 20/1- IGI !NJ '100/2 ENTRANCE O i L.I I UT-202 RATED PROVIDE AND INSTALL TELEPHONE RACEWAY TO NEW SERVICE !BREAKER T 1 20/1 EILEPHONE WEATHER HEAD, INSTALL ADJACENT TO EXISTING 20/1 ENTRANCE 1 PANEL IN PAY PHONE- 2 RATED C — FIT -201 FLOW METER 0— J -102 BREAKER PANEL IN 20 /1 CONSOLE PROVIDE AND INSTALL METER BASE ON EXTERIOR OF FLOW ' 20/1 METER 'CONSOLE PANEL. 2 FLOW METER 0— TELEMETRY 0— FIT -1101 CONSOLE PANEL E5:�--, PROVIDE AND INSTALL ELECTRICAL AND TELEPHONE RACEWAY 20/1 TO NEW WEATHER HEADS AT TELE/PDWER POLE WITH 20/1 4 — T' EMITRY TELEPHONE LINE DROP. TELEMETRY 0 — LIT-204 EXISTING LIFT STATION F­ ­ N�TALIL ELECTRICAL TO /UP POLE PER PUGET DESIGN S 20/1 STANDARDS. FIELD VERIFY DISTANCE TO POLE. 5 20/1 4 C— PANEL OUTLET 0— PANEL HEATER [6:::--, PROVIDE AND INSTALL MET ER AND BASE FOR PRIVATE 20/1 20/1 METERING (NON-UT11-ITY). BASE SHALL BESQUARE-D 5 6 URTRS 101B WITH ACP CLOSING PLATE. METER SHALL BE o— PANEL OUTLET 0— PANEL HEATER ASS D5S METER, WITH POLYCARBONATE COVER, OR EQUAL. 20/1 20/1 7 6 -0 0— SUMP OUTLET 0— SUMP OUTLET I RENTON PARK SITE BRYN MAWR SITE SINGLE LINE DIAGRAMS INLET SITE PLAN : SIPHON INLET STRUCTURE — BRYN MAWR SITE SCALE: 1 20" lRecord Drawing12/00 These drawings have been modified to conform with information provided by the contractor. See original file copies for engineer's professional 06 0 < 01 Qz 1 DESIGNED: ;CHECKED: I HPARMENT OF NATURAL RESOURCES DATE: L)ANUARY 1998 ENPNEERM, INC. IDM9 DMB BRYN MAWR SYSTEM IMPROVEMENTS GARRY STRUTHERs ASSODATES, INC. 110- 1.110 _...a11 n, #100! DRAWN: SCALE: SCHEDULE A 3150 Richards Road, Suite 100 Wi C—k, WA. DE012 IF'— (425) 338-2416 Bellevue, WA 98005 -4446 F.. (4 s) 338-0827 !HJ REVISED PER RECORD DRAWING MARKUPS MKW 12-00 Phone: (425) 519-0300 -fiECOMMENDED: AS SHOWN ELECTRICAL SITE PLANS & [oR nwms No CONFORMED CGH 2,98 Fax: (425) 519-0309 King County No. REVISION APPROI 6 El 01 CONTRACT NO: SINGLE LINE DIAGRAMS BY �APP'D� DATE C73130C SHEET N0: OF V V V V I I I L - G H