HomeMy WebLinkAboutS-071104r 200A 3P 1 FU - FU I i trio A p 150 P 1 F 200 A d lI L_ 4 - #1 /d AWG 5.5W S.SIN Z 00 AMP 60 AMP FU _- FU 1'19 GO AM P � 2�1 T�wvJ -� - v N 3 *1 O Ak)G TN k1- -� 2 VUPLE%�( SSW -60AMP FU � —2y. _v A 4ao - 12o/240 VAC 110 24 14 — TZESEP !7 t 5O AR LEVEL. XMTR RELAY 4u>t4 2414 PANEL I 212 CONO 4'!2 AWG'T12EY, 4# SpA G -ntZEX 2114 _J 4* 110 AWG T14W CAF5L P_ r. -- — -- - (SEE PUMPr-- - -� PLAPJ OW& 01) FUTURE STANDBY . TIT?E TIrz FEY GENERATOR I CABLE I CA51 -t TO UTILITY POLE i t 1-'JJMP .0, STARTSG ASSEMPSLY RY MUNICIPALITY MTR 60 `-IP MTR 30 NP ONE L I N E DIAGRAM LEVEL TRANSMITTER AND TELEMETRY Ta SAFETY Sh11TCHE� ® >ZY- GAr31NETr✓,F3Y l (5EE ONE. LINE DIAGRAM 1✓IUNIGIPALITY7-- i +1 CR2 - Pump tri Tr2 - PUMp**2 (5 5EC TI7G ) . (M7P IN RELAY PNL)) 'I DIRTERICN -►OfT COMPANY 400 1020.0 (9-71) M �9 RLJVP Imo l S TA127E'Z CFLIIZ JISNED 13Y METRO. I 1I i NiTR I�UMn 3 1 - X00 {•iP PUMP #2 - 30 HP In L'1tC - Co%Ltm"IT TO sA TYPICAL PUMP MOTOR �50NAK LEVEL s6NsOIZ CONTROL DIAGRAM N1TO IN MH RI°- 3 -. (5 EE DwG- Na 2 O 1 I 8 TR5 ©g.s -TOOIt�,.. -. 9 10 2 tI 5,9 5) PUMP* 1- - 7 B.s �, 9,11, PuMP�2 U M I TO RENTON TPEATMENT PVC CONDUIT 11 r2? T�TKOCI T I PLANT VIA 1- 2G -58 A/U INST EL EPROWF_ LINES GO -AXIAL CA15LE SONIC F52 - - -� LEVEL SENS02 (5EE DETAIL PutvIPING sTA-rioN PLAN OW &# 2) CONTROL DIAGRAM SONAR LEVEL SENSOR hUPL.E)( 121?CEPTACLE5 MTD. IW 4"5Q F30X RAItQTjCvI-IT PANEL- BOArZD, SQ D CO, CA7'rQ0(o -tZ Q SA04- 10AMPr3KrZ 490- 1ZO /240V 8:0 "± 2KVA TRANS, G. . GO, cA-rgTSIY10 - 3 S �M��' �°1 -200 AMP IT, AFETY5W. METER F3ASE C I(Z GL E A- W P2000GTS RELAY SCHEDULE DEVICE D E SCRIPTION CR1. CONTROL RELAY CONVERTIBLE CONTACTS, SQ D CO, CLASS 8500, CAf NO GO -40 CR2 SAME AS CR 1 TR1 TIMING RELAY, CONVERTIBLE CONTACTS, SQ D CO, a CLASS 8500, CAT NO GO-40, WITH TYPE GE PNEU- TR2 MATI'C TIMER ATTACHMENT U.V. UNDER VOLTAGE RELAY, ADJUSTABLE PICK -UP VOLT- AGE 92-140 VOLTS, 6011Z, SET AT 108 VOLTS; ADJUST- ABLE DROP -OUT VOLTAGE 90-138 VOLTS, 60 HZ SET AT 90 VOLTS; POTTER & BRUMFIELD CAT NO CSJ CKET 70010; WITH SURFACE MOUNTED OCTAL R ASE, O CAT NO 27E122 TR3 TIMING R RELAY, DELAY ON DE- ENERGIZATION, 3-30 MIN RANGE (SET @ 15 MIN), AGASTAT SERIES 7000, MODEL #7022AH FS1 FLOAT SWITCH, CONTACTS NORMALLY OPEN & CLOSED @ ELEV 156.00, DELAVAL, GEMS SENSOR FS2 DIVISION MODEL LS -1900, PIC #01907 CR3 CONTROL RELAY 120 VOLTS, 60 HZ 3 PDT POTTER & BRUMFIELD KOP14A, WITH SURFACE M06NTED 11 PIN SOCKET 7 TefZM►Nh.L - -- GAT *t A -'O7GG /. A Z S #/, Z.5-*?, 1- 5 0 5 Z OCATED G!T /TN /N _5'ONIC lFI/EL Z A" r�,4 NSM /T rE2 CAB /NET." ZOi'z�NOUI t7� LS #/ r0 CLOSED ,4r rz-5x /50.36 Fr. WIPP GC�Nt7U1T 0 71 Y 53 ¢ F1 a'x (op NEN1A 3R GurrER so aGo 11 R 0 G4 IZOOAM1� 24AX20 "Xa 0AM 200 AMh DOUBLE TZELAY [5AFEV SAFETY T I-I r r'AhIEL WITCH SWITGt -1 SAFETY U F:rMAt i 00 Co SQ O GD Sw i TGN 4­7 Z TO CL 05E0 A EL E. / . 7 L 5 *3 r0 Cl- 05ED AT F•L Fl! 155.36 Fr. ® ® Z. ALL FUSE'S 51-IAL L f S-,f', i TED FOP 600 POL T.S AND BE CAPA 15L E- OF /N 7'S–RRU )0TING 147 LEA 5T PO, ODO 41OP-5 GR1 GR2 ,-M.S. S l`"Al "re /CAL 4,C. FUSES S� /ALL FEE f3USSMA /V� rYPE' F �.5 , UV TQ3 CR3 it tA- 242008LP u roan N ;(p41�6 SG? D. Got w ®� l.J ` $VS23 4 -F G (INSULATING �, N A �11 ,ii r 'e�• .1-R if ' ' • � • � 1.5 4;H I I.ICG 0. 4. 1 ELECT. MFG CO TYPE 4\55 FRI R2 STA,CZrEr2 O �FurzNlc, uEn>3Y - 17x21 PANEL KrQ - IINSIIDE 'Z4 X2n x & N V L"S U I� E - - — 4 _- -- - -_ - -- 1... NOFFMAN WEMA 12 AT 1-40. A- 242OC) 8 LP X ° / f�RIP SN IF IUT \ - A -nK20 h of '.,,: RELAY PANEL %4TZIG1(� GONIDUIT TO ;,, >f, '��. i �� j� TELERWONE LINE VIA / \ TO TRANSFC�RME2 T-lOWE1 -2 GALE `c► VAULT. (SEE PLOT PLAN OWb, W0.1) 5EE DWG. W0. 2 3 ' _- �4 RIGID STL COND.' W. M MH RIO -Z3 SEE I= LOAT_- ����1��F wasy,4llo :,SW, MOLIN'r'DLTAIL DW4f 2 `'z ISTERF'� �O E�6 TEMPORARY ELECTRICAL DISTRIBUTION NA� PA N E LBOAR D DETAILS - © TEL E.c�ET,PY CAB, BY ,u�r,�o 0• � �� i DESIGNED: DATE: APR Z ® L. S.rOCLOSEA> /55.36 D•G /��j DRAWN: MUNICIPALITY OF METROPOLITAN SEATTLE FILENO1973 © 8•S ADD &7D 0•c- s /� /� R o YEN ERGA CEDAR RIVER TRUNK S�TION I, TEMPORARY BYPASS 7105A CONTRACT PUMPING STA I AND F RCE MAIN DRAWING O, Fl o,4rSly. OA T.4 ADDEO �. CT. Z¢ " Dr. i' e u fi (} APPROVED:. M2-73 ELECTRICAL ONE AND CONTR L NS R E V I S ION BY DATE ----- -;,�:� DIAGRAMS sNE�r 4 of 4