HomeMy WebLinkAboutS-0726185 4 3 A - B GENERAL at I THE GENERAL NOTES AND TYPICAL METRO DETAILS ARE GENERAL AND APPLY TO THE ENTIRE PROJECT EXCEPT WHERE THERE ARE SPECIFIC INDICATIONS TO THE CONTRARY. G2 CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE UNIFORM BUILDING CODE. THE ABOVE SHALL GOVERN EXCEPT WHERE OTHER APPLICABLE CODES OR THE FOLLOWING NOTES ARE MORE RESTRICTIVE. G3 THE STRUCTURAL SYSTEMS AND DETAILS ON THESE PLANS ARE THE PRIORITY DESIGN. ALTERNATIVE SYSTEMS AND DETAILS MAY BE USED IF THE CONTRACTOR SUBMITS PLANS WITH SUBSTANTIATING CALCULATIONS AND TEST DATA, AND IF THE ALTERNATIVE PLANS ARE ACCEPTED BY THE ENGINEER. G4 M� STRUCTURAL DIMENSIONS CONTROLLED BY OR RELATED TO MECHANICAL OR ELECTRICAL EQUIPMENT SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. G5 FM awemm MECHANICAL AND ELECTRICAL EQUIPMENT SUPPORTS, ANCHORAGES, OPENINGS, RECESSES AND REVEALS NOT SHOWN ON THE STRUC- TURAL DRAWINGS BUT REQUIRED BY OTHER CONTRACT DRAWINGS SHALL BE PROVIDED PRIOR TO CASTING CONCRETE. G6 STRUCTURES HAVE BEEN DESIGNED FOR OPERATIONAL LOADS ON COM- PLETED STRUCTURES, DURING CONSTRUCTION, STRUCTURES SHALL BE PROTECTED BY BRACING AND BALANCING WHEREVER EXCESSIVE CONSTRUCTION LOADS OR INSTABILITY MAY OCCUR. 07 A. FLOOR AREAS: (1) OPERATING FLOORS ((FLOORS ON WHICH MACHINERY MAY BE DISASSEMBLED) 200 PSF. (2) ENGINE OR MOTOR ROOM AND SIDEWALKS - 250 PSF. (3) UNLOADING AREAS - 2 -1/2 TON TRUCK OR 100 PSF. (4) TRUCK TRAFFIC AREAS- AASHTO HS 20 LOADING OR 250 PSF. (5) ALL OTHER AREAS- 100 PSF B. GRATINGS, CHECKERED PLATES, AND HATCHES - SAME LOADINGS AS ADJACENT FLOOR AREAS. C. STAIRS - 100 PSF. D. ROOF - 25 PSF. E. WIND- 20 PSF SUBJECT TO HEIGHT AND SHAPE RESTRICTIONS. F. SEISMIC LOADING- ZONE 3 UNIFORM BUILDING CODE 06 0� SLOPE DRAINAGE SURFACES UNIFORMLY TO DRAIN. SLOPE SHALL BE 1/4' PER FOOT EXCEPT THERE NOTED OTHERWISE ON THE DRAWINGS. AT CONTRACTOR'S OPTION, BOTTOM OF SLAB MAY BE LEVEL AND MAINTAIN A MINIMUM THICKNESS AT FLOOR DRAWS. 2 G9 F1�.QfAm SEE ARCHITECTURAL & MECHANICAL DRAWINGS FOR LOCATION k SIZES. IF)x A OE M "to We" C 0 ALUMINUM Al AMUCARL( ALUMINUM CONSTRUCTION SHALL CONFORM TO THE'LATEST EDITION OF THE ALUMINUM CONSTRUCTION MANUAL OF THE ALUMINUM ASSOCIATION. A2 JAZft UNLESS OTHERWISE INDICATED, STRUCTURAL ALUMINUM SHALL BE ALLOY 6081 -T6 AS SPECIFIED IN ASTM B -308. A3 ANJll111 W OOYTACT WTM C1IIdETe WHERE ALUMINUM IS IN CONTACT WITH CONCRETE OR MASONRY SURFACES, CONTACT SURFACES SHALL BE COATED WITH HEAVY ALKALI- RESISTANT BITUMINOUS PAINT. CONCRETE Cl AsM rM CONCRETE CONSTRUCTION SHALL CONFORM TO THE LATEST EDITION OF THE ACI BUILDING CODE (ACI-318). C2 ALL OETAILING, FABRICATION, AND ERECTION OF REINFORCING BARS, UNLESS OTHERWISE NOTED SHALL BE IN ACCORDANCE WITH MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUC- TURES (CRSI AND /OR ACI-315), LATEST EDITION. C3 A. CONCRETE, f 'c 4,000 PSI ULTIMATE COMPRESSIVE STRESS AT 28 DAYS. (fc -0.45 f 'c FOR ALTERNATE DESIGN METHOD), UNLESS OTHERWISE SPECIFIED. B. REINFORCING STEEL 1 TENSION DUE TO FLEXURE, GRADE 60 (fs- 24,000 PSI) 2 COLUMN REINFORCING, GRADE 60 (f.- 20,000 PSI) J CIRCULAR TANK HORIZ WALL REINF. IN HOOP TENSION, GRADE 60 (fe- 16,000 PSI). C4 CONCRETE COVER FOR REINFORCING BARS SHALL BE AS FOLLOWS WITH MINIMUM COVER OF ONE BAR DIAMETER. A FOOTINGS AND FOUNDATION MATS CAST ON GROUND - 3'. B. CONCRETE TO BE IN CONTACT WITH LIQUID - 2 -1/2'. C. CONCRETE TO BE IN CONTACT WITH GROUND OR WEATHER. (1) BARS GREATER THAN 05 - 2' (2) BARS /5 OR LESS - 1 -1/2' D. CONCRETE NOT TO BE EXPOSED TO GROUND, WEATHER, OR LIQUID. (1) BEAMS AND COLUMNS - 1 -1/2' F ) SLABS, WALLS, AND JOISTS - 1' ALL BARS SHALL BE CLEAR OF ANY ARCHITECTURAL RUSTICATION OR REVEAL - 1' CS CONCRETE CONSTRUCTION SHALL BE REINFORCED CONCRETE EXCEPT WHERE PLAIN CONCRETE IS INDICATED ON THE DRAWINGS. UNLESS OTHERWISE NOTED, MINIMUM REINFORCING STEEL SHALL BE PROVIDED IN ACCORDANCE WITH THE FOLLOWING SCHEDULES: A. SLAR REINFORCEMENT SLAB THICKNESS SIZE SPACING EW 4' a. 5" k 6' /N,5 9' 8' THRU 10' /5 12" T k B 12' 8: 14' j5 9' T k B 16' 06 12' T k B B. WALL REINFORCEMENT WALL THICKNESS SIZE SPACING EW POSITION 6' t e' /5 9' ON CENTER LINE 10' /5 12' EF 12' 8: 14' 05 9' EF 14' 06 12, EF 16' THRU 20' 06 9' EF MASS CONCRETE SHALL BE REINFORCED WITH #6 • 12' EW MINIMUM IN ALL FACES. E - F C8 ADOEO 7ri� lTEd M w WHERE BEAMS OR WALLS ARE PARALLEL TO MAIN REINFORCING IN SLAB, PROVIDE /4 • 12' IN TOP OF SLAB NORMAL TO BEAM OR WALL. EXTEND BARS 2' -0 BEYOND FACE OF BEAM OR WALL. WHEN SLAB IS ON ONE SIDE ONLY, TERMINATE BARS WITH STANDARD HOOK ON OTHER SIDE OF BEAM OR WALL, UNLESS OTHERWISE SHOWN ON THE DRAWING. C7 IN ADDITION TO NORMAL ACCESSORIES USED TO HOLD REINFORCING STEEL FIRMLY IN POSITION, EXTRA ACCESSORY BARS SHALL BE USED AS FOLLOWS: A. IN SLABS 05 RAISER BARS AT 36' 0/C MAXIMUM TO SUPPORT TOP REINFORCING STEEL. B. IN WALLS WITH TWO CURTAINS /3 U OR Z SHAPE SPACERS AT 6' -0 0/C E.W. C8 Bu jm jBm CONCRETE STRENGTH - 4,000 PSI GRADE 60 REINFORCEMENT BAR SIZE 06 OR SMALLER #7 08 09 /10 /11 TOP BAR* 48 DIA, MIN 3' -8 4' -9 6' -0 7 -4 9' -0 OTHER BAR 40 DIA, MIN 2' -10 3' -B 4' -8 5' -10 7' -0 • TOP BARS SHALL BE DEFINED AS ANY HORIZONTAL BARS PLACED SUCH THAT MORE THAN 12' OF FRESH CONCRETE IS CAST IN THE MEMBER BELOW THE BAR, IN ANY SINGLE POUR. C9 I BARS ENDING RIGHT ANGLE BENDS OR HOOKS SHALL CONFORM TO THE REQUIREMENTS OF PAR. 7.1, AC1 -318. ALL HORIZONTAL REINFORCING BARS SHALL BE TERMINATED IN STANDARD HOOKS UNLESS OTHERWISE SHOWN WITH 90 DEGREE HOOKS OR SPECIFIED ANCHORAGE. CIO ALQBIQ-xm MONOLITHIC SLABS WITH TOPS THAT ARE SLOPED SHALL HAVE BOTTOMS FLAT, MAINTAINING A MINIMUM THICKNESS AT DRAIN. MAINTAIN A VARIABLE SLAB THICKNESS, UNLESS OTHERWISE SHOWN. C11 CONCRETE SLABS SUPPORTED BY GROUND, UNLESS OTHERWISE NOTED, SHALL BE 6' THICK REINFORCED WITH WWF 6 X 6 - W29 X W2.9 AT MID -DEPTH OF SLAB AND DOWELED ALONG THE EDGE OF SLAB TO ALL ADJACENT WAILS, COLUMNS AND FOUNDATIONS WITH /4 • 15' THAT LAP 1' -0 WITH WWF AND EXTEND INTO WALLS, COLUMNS AND FOUNDA- TIONS AT LEAST 91; IF SLAB IS DESIGNATED AS 'ISOLATED SLAB' ON DRAWINGS. OMIT DOWELS AND SUBSTITUTE 318' THICK PREMOLDED JOINT FILLER TO ISOLATE THE SLAB FROM CONTACT WITH THE STRUCTURE ALONG ITS PERIMETER. C12 EXCEPT AS OTHERWISE REQUIRED, EXPOSED CONCRETE CORNERS AND EDGES SHALL HAVE 314' CHAMFERS. RE- ENTRANT CORNERS SHALL NOT HAVE FILLETS. C13 ANCHOR BUIS USE OF ANCHOR BOLTS SHALL BE GOVERNED BY THE FOLLOWING TABLE: BOLT DIAMETER 1/2' 5/8' 3/4' 7/8' 1- 1_1/8' 1 -1/4' MIN. EMBEDMENT N STRUCTURAL CONCRETE 4' 4' 5' 6' 7' 8' 9' ALLOWABLE SHEAR 2000/ 3000/ 35600 4150/ 4150/ 45000 53000 ALL BOLTS, STUDS AND MISCELLANEOUS METALWORK SHALL BE HOT DIPPED GALVANIZED UNLESS OTHERWISE NOTED. EMBEDMENT LENGTH FOR BOLTS IN TENSION SHALL BE DETERMINED BY THE ENGINEER. STAINLESS STEEL BOLTS SHALL BE USED WHERE SPECIFIED AND /OR AS DIRECTED BY THE ENGINEER. ,�I "u ,,•,n drAfn maz W. MAN Brown end CinldwNl Consultants •��"�'�'�'�� �I'�'M � C^D �A,. '�„ Seattle, Washington ,eeo JR CITY OF RENTON �� J. wARBUaraN agAaTUMMT on PUHiaC Woxxs [ B C 0 E AL' ,... �._.. - �_ _ _ « - -- -- - _� 1 r` I NMI tltii+iietifil Meat i• Is" elves than thi• vtiea, it is Am to the quenty K the me"I"I MeumMt. t La 9z sz ,a cc to it OZ at at 41 91 at ##I al. O1 s F 9 G _ M W,3(nm ST1 STEEL CONSTRUCTION SHALL CONFORM TO SPECIFICATIONS AND STANDARDS PRESENTED IN THE LATEST EDITION OF RISC STEEL CONSTRUCTION MANUAL. CAMBERING OF BEAMS AND GIRDERS SHALL BE AS SPECIFIED IN TABLE OF MAXIMUM AND MINIMUM CAMBER UNLESS OTHERWISE SPECIFIED. ST2 MAVJAL ALL STRUCTURAL SHAPES, BARS, PLATES AND SHEETS INDICATED ON THE DRAWINGS SHALL BE STEEL MEETING ASTM A -36 SPECIFICATIONS. ST3 MUM WELDING SHALL CONFORM TO AWS CODE FOR ARC AND GAS WELDING IN BUILDING CONSTRUCTION WELDER SHALL BE CERTIFIED BY WASHINGTON ASSOCIATION OF BUILDING OFFICIALS (OR AWS). ST4 } STANDARD SHAPE STRUCTURAL STEEL COMPLETELY ENCASED IN CONCRETE SHALL NOT BE GALVANIZED OR PAINTED AND SHALL HAVE A CLEAN SURFACE FOR BONDING TO CONCRETE WHEN IT IS CAST. ST5 pAWQ STRUCTURAI STEEL SHALL BE PAINTED IN ACCORDANCE WITH SPECIFICATIONS. ST6 STAINLESS STEEL CONSTRUCTION SHALL BE IN ACCORDANCE WITH AISI SPECIFICATIONS. WHEN STEEL IN CONTACT WITH SEWAGE AISI TYPE 316 STAINLESS STEEL SHALL BE USED. WHEN MATERIAL IS WITHIN ONE FOOT HORIZONTALLY OR VERTICALLY OF SEWAGE AISI TYPE 304 STAINLESS SHALL BE USED EXCEPT AS SPECIFIED. MODIFICATION OF EXISTING CONCRETE M1 THE FOLLOWING NOTES ON MODIFICATION OF EXISTING CONCRETE ARE GENERAL AND APPLY TO THE ENTIRE PROJECT EXCEPT WHERE THERE ARE SPECIFIC INDICATIONS TO THE CONTRARY. M2 EXISTING CONCRETE SURFACES TO BE JOINED WITH NEW CONCRETE SHALL BE THOROUGHLY CLEANED AND COATED WITH EPDXY BONDING COMPOUND IMMEDIATELY PRIOR TO PLACEMENT OF THE NEW CONCRETE. M3 UNLESS OTHERWISE SPECIFIED, DOWELS SHALL BE SET INTO DRILLED HOLES WITH EPDXY GROUT. EPDXY GROUT SHALL BE FORCED INTO HOLES TO FILL THE VOIDS. HORIZONTAL HOLES SHALL BE DRILLED SLIGHTLY DOWNWARD (APPROXIMATELY 151. M4 STRUCTURAL DIMENSIONS RELATED TO OR CONTROLLED BY EXISTING STRUCTURES SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR PRIOR TO CONCRETE WORK. t.l ' .t e 4 3 2 3MmiTAO Mua{et/WtY tOLtopOt.nR..,XL .q FEB 1993 r, .r. BOEING CHLLER COOLING WATER SUPPLY 5936SO01.0WG NO SCALE w .nn. I; • GENERAL STRUCTURAL NOTES S1 W�A1 15 -9,1 G H I�III�I�I�III�I�I�III�I�I�III�III�II 10 11 1M1II> 12- IIIIIIII�IIIIIIIII�IIIIIIIII�IIIIIIIII�IIIIIIIII�III yS'1 °_ Flom