GENERAL NOTES
1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH CITY OF RENTON STANDARDS AND SPECIFICATIONS.
2. THE LOCATIONS OF FEATURES SHOWN ARE APPROXIMATE AND SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR PRIOR TO STARTING WORK.
3. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS. THE CONTRACTOR SHALL CONTACT ALL PERTINENT UTILITY AGENCIES 48 HOURS
BEFORE COMMENCING WORK AND SHALL COORDINATE WITH AFFECTED UTILITY AGENCIES THROUGHOUT THE PROJECT.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY COMPANY
AND THE CITY IMMEDIATELY UPON DAMAGE.
5. STREET LIGHT STANDARD WITH DAVIT MAST ARM SHALL BE INSTALLED PER CITY OF RENTON STANDARD PLAN 115.
6. STREET LIGHT STANDARD FOUNDATIONS SHALL BE INSTALLED PER CITY OF RENTON STANDARD PLAN 115 AND 119.
7. STREET LIGHTS SHALL ADHERE TO CITY OF RENTON STANDARDS.
8. JUNCTION BOXES SHALL BE LOCATED WITHIN 5FT OF LUMINAIRE POLES WHEN FEASIBLE AND SHALL BE INSTALLED OUTSIDE OF SIDEWALK AND DRIVEWAY.
9. POST -TOP FOUNDATIONS AND INSTALLATION SHALL BE COORDINATED WITH THE MANUFACTURER AND SHALL ADHERE TO CITY OF RENTON STANDARD PLAN
116.1 AND 119.
10. INSTALL STREET LIGHT STANDARD DECAL ON EVERY NEW LIGHT STANDARD PER CITY OF RENTON STANDARD PLAN 121.
LUMINARE POLE SCHEDULE
LUMINAIRE
MINIMUM AVERAGE
LIGHT LEVEL (FC)
MAXIMUM UNIFORMITY
RATIO (AVG /MIN)
TARGET
CALCULATED
TARGET
CALCULATED
INTERSECTION
SE 136TH / HOQUTAM AVE
1.2
1.27
POLE
LOCATION STATION
STATION
CPS
POLE OFFSET
MOUNTING
ARM LENGTH
WATTAGE
CIRCUIT NO.
LUMINARIE
4
3.00
REFERENCE
SE 136TH EAST
COORDINATES
(FT)
HEIGHT (FT)
(FT)
(WATTS)
SVC /CKT
POLE NUMBER*
COMMENT
N0.
SE 2ND EAST
0.9
0.98
4
1.63
SE 2ND WEST
0.9
1.03
4
3.43
1
SE 2ND PL /SE 136TH ST
28 +32.5
47.481203281,
_122,153581936
20.0 RT
30
8
94
A/1
6
PER CITY OF RENTON
STANDARD PLAN
2
SE 2ND PL /SE 136TH ST
29 +63.0
47.481199954,
- 122.153055069
20.0 RT
30
8
94
A/1
PER CITY OF RENTON
STANDARD PLAN
3
SE 2ND PL /SE 136TH ST
30 +55.0
47.481197596,
- 122.152682077
20.0 RT
30
8
94
A/1
PER CITY OF RENTON
STANDARD PLAN
4
SE 2ND PL /SE 136TH ST
31 +99.0
47.4811939219
_122,152100769
20.0 RT
30
8
94
A/1
PER CITY OF RENTON
STANDARD PLAN
5
ON -SITE
10 +43.5
47.481135096,
_122,152862557
10.0 LT
14
N/A
44
A/2
PER CITY OF RENTON
STANDARD PLAN
6
ON -SITE
11+46.5
47.480851947,
_122,152964411
16.0 RT
14
N/A
44
A/2
PER CITY OF RENTON
STANDARD PLAN
7
ON -SITE
12 +49.5
47.480570051,
- 122,152831721
16.0 LT
14
N/A
44
A/2
PER CITY OF RENTON
STANDARD PLAN
8
ON -SITE
13 +52.5
47.480286773,
- 122,152957837
16.0 RT
14
N/A
44
A/2
PER CITY OF RENTON
STANDARD PLAN
9
ON -SITE
14 +53.5
47.480009888,
- 122,152954616
16.0 RT
14
N/A
44
A/2
PER CITY OF RENTON
STANDARD PLAN
10
ON-SITE
15 + 44.5
47.479752747,
- 122,152797564
16.0 RT
14
N /A
44
A/2
PER CITY OF RENTON
STANDARD PLAN
11
ON -SITE
16 +36.0
47.479816927,
- 122.152401185
16.0 LT
14
N/A
44
A/2
PER CITY OF RENTON
STANDARD PLAN
1
ON -SITE
17 +28.5
47.479818166,
- 122.152047087
16.0 LT
14
N/A
44
A/2
PER CITY OF RENTON
STANDARD PLAN
1
ON -SITE
18+ 13.0
47.479956174,
- 122,151801438
16.0 RT
14
N/A
44
A/2
PER CITY OF RENTON
STANDARD PLAN
14
ON -SITE
18 +87.5
47.480160397,
_122,151803809
16.0 RT
14
N/A
44
A/2
PER CITY OF RENTON
STANDARD PLAN
15
ON -SITE
19 +61.0
47.480361199,
- 122,151935551
16.0 LT
14
N/A
44
A/2
PER CITY OF RENTON
STANDARD PLAN
16
ON -SITE
20 +55.5
47.480621320,
_122,151809160
16.0 RT
14
N/A
44
A/2
PER CITY OF RENTON
STANDARD PLAN
1
ON -SITE
21 +47.5
47.480872838,
_122,151941492
16.0 LT
14
N/A
44
A/2
PER CITY OF RENTON
STANDARD PLAN
18
ON -SITE
22 +39.5
47.481125738,
- 122,151815017
16.0 RT
14
N/A
44
A/2
PER CITY OF RENTON
STANDARD PLAN
19
SE 2ND PL /SE 136TH ST
32 +91.0
47.481 1 91 564,
_122,151728329
20.0 RT
30
8
94
A/1
PER CITY OF RENTON
STANDARD PLAN
0
SE 2ND PL /SE 136TH ST
33 +80.0
47.481189289,
_122,151369048
20.0 RT
30
8
49
A/1
PER CITY OF RENTON
STANDARD PLAN
2
SE 2ND PL /SE 136TH ST
34 +68.5
47.481187014,
_122,151009768
20.0 RT
30
8
94
A/1
PER CITY OF RENTON
STANDARD PLAN
SE 2ND PL /SE 136TH ST
36 +49.0
47.481177796,
- 122.150281412
21.5 RT
30
8
94
A/1
/
PSE UTILITY POLE
* NUMBER TO BE PROVIDED BY CITY OF RENTON DURING CONSTRUCTION PER CITY OF RENTON STANDARD PLAN 121.
DATE
DESIGNED BY MMG 104/23/2015
DRAWN BY MMG 04/23/2015
REVIEWED BY RWP 104/23/2015
REVISION
mmmmff�m
LIGHT LEVELS
INTERSECTION /ROADWAY
MINIMUM AVERAGE
LIGHT LEVEL (FC)
MAXIMUM UNIFORMITY
RATIO (AVG /MIN)
TARGET
CALCULATED
TARGET
CALCULATED
INTERSECTION
SE 136TH / HOQUTAM AVE
1.2
1.27
4
2.12
SE 2ND PL / ROAD C
1.2
1.24
4
4.13
SE 2ND PL / ROAD A
1.2
1.20
4
3.00
ROADWAY
SE 136TH EAST
0.9
0.94
4
2.35
SE 136TH WEST
0.9
0.97
4
3.23
SE 2ND EAST
0.9
0.98
4
1.63
SE 2ND WEST
0.9
1.03
4
3.43
RESIDENTIAL SIDEWALKS
SIDEWALK 1
0.3
0.28
6
2.80
SIDEWALK 2
0.3
0.24
6
2.40
*LIGHT LEVELS PER CITY OF RENTON CODE SECTION 4 -6 -060.
381402
5/y d /..r
trilanspogroup
Tr
P� � W Sy J'
.� Mao
THE QUADRANT CORPORATION
I L 2
WHAT TRANSPORTATION CAN BE.
^�
��P ° �
�
COPPERWOOD PLAT
C
11730 118TH AVENUE NE, SUITE 600 (TEL) 425 821 -3665
KIRKLAND, WASHINGTON 98034 425 825
A a
�0 F tSrE E�v� �
}
SSfOhAL
IN OF RENTON APRIL 2015
SHEET
2
(FAX) -8434
E� 1�
�
m
m
ILLUMINATION
PLAN
SHEETS
Am
Z
.Z
G7
Z
_=
_'
C
-z
z
m
m
I
:z
z�
z
Z
z
z�
z
rr-
J
0
n
D
Z
Z
C
3
m
1
1
o
_'