HomeMy WebLinkAboutzT-3814Set0
N
N
\
g
0
J
J
N
v+
c
W
C
t
a
O
U
N
0
/
NOTE
1. SEE IL2 FOR LUMINAIRE POLE SCHEDULE, LIGHT LEVELS AND GENERAL NOTES.
2. SEE IL3 AND IL4 FOR CITY OF RENTON STANDARD PLANS.
TRACT C
O
0
C
� 6
m ;.
i
i
Q%
DESCRIPTION
RIGHT OF WAY
CONDUIT
LUMINAIRE & POLE
DECORATIVE POST TOP
LUMINAIRE AND POLE
JUNCTION BOX TYPE 1
JUNCTION BOX TYPE 2
STREET LIGHTING CONTACTOR
CABINET
UTILITY POLE (BY OTHERS)
WIRE NOTE
LUMINAIRE POLE NUMBER
CONSTRUCTION NOTE
D
El T- 381401
WIRING SCHEDULE
D
N0.
RACEWAY CONDUIT
SIZE*
CONDUCTOR
COMMENTS
1
2" SCH40
2 -#8
ILLUMINATION +GROUND
2
2" SCH80
2 - #8
ILLUMINATION +GROUND
3
2" SCH40
4 - #8
ILLUMINATION +GROUND
4
2" SCH80
4 - #8
ILLUMINATION +GROUND
5
PSE TO PROVIDE POWER CONNECTION
*ALL CONDUIT SHALL BE PVC AND SHALL CONTAIN A GROUND WIRE EQUAL IN
SIZE TO THE LARGEST CONDUCTOR, UNLESS OTHERWISE NOTED.
CONSTRUCTION NOTES
O INSTALL PRESTIGE SERIES 44W LED POST -TOP
LUMINAIRE (CY17T4 VS3AR 31_3 44W 4000K 240 277V
RAL 9005TX "JET BLACK" UNIVERSAL DRIVER) BY
CYCLONE AT 14FT MOUNTING HEIGHT PER CITY OF
RENTON STANDARD PLAN 116.1.
O INSTALL AUTOBAHN AT62 94W LED COBRA STYLE
LUMINAIRE (ATB2 406LEDE70 MVOLT R3 NQ BY
AMERICAN ELECTRIC LIGHTING (AEL) WITH 8FT DEVIT ARM
AT 25FT MOUNTING HEIGHT PER CITY OF RENTON
STANDARD PLAN 115.
3O INSTALL AUTOBAHN ATBO 49W LED COBRA STYLE
LUMINAIRE (ATBO 206LEDE70 MVOLT R3 NQ BY
AMERICAN ELECTRIC LIGHTING (AEL) WITH 8Ff DEVIT ARM
AT 25FT MOUNTING HEIGHT PER CITY OF RENTON
STANDARD PLAN 115.
4O INSTALL TYPE 1 JUNCTION 80X PER WSDOT STANDARD
PLAN J- 40.10 -03.
5O INSTALL TYPE 2 JUNCTION 80X PER WSDOT STANDARD
PLAN J- 40.10 -03.
6O EXISTING LUMINAIRE TO REMAIN.
7Q INSTALL 120/240 VOLT STREET LIGHTING CONTACTOR
CABINET PER CITY OF RENTON STANDARD PLAN 123.
8Q TRANS. MAIN. WILL COORDINATE WITH PSE FOR FINAL
POWER CONNECTION TO EXISTING POWER POLE AND
TRANSFORMER UPON ACCEPTANCE OF LIGHTING SYSTEM.
CONTACT ERIC CUTSHALL OF TRANSPORTATION
O9 BEGIN UNDERGROUNDING OF EXISTING OVERHEAD
UTILITIES.
10 INSTALL AUTOBAHN AT82 94W LED COBRA STYLE
LUMINAIRE (AT62 406LEDE70 MVOLT R3 NQ BY
AMERICAN ELECTRIC LIGHTING (AEL) WITH SfT ARM AT
25FT MOUNTING HEIGHT ON PROPOSED UTILITY POLE.
•
LL
DATE
REVISION
BY
DATE
transpogroup
WHAT TRANSPORTATION CAN BE.
11730 118TH AVENUE NE, SUITE 600 (TEL) 425 8213665
KIRKLAND, WASHINGTON 98034 (FAX) 425 825 -8434
�,���P"'"syRso
�� °z�
A a
F 7363 �� ,��v s
SS�OhAL ti�U tJ� �
THE QUADRANT CORPORATION
COPPERWOOD PLAT
6TY OF RENTON APRIL 2015
I1
DESIGNED BY MMG
04/23/20151
o0
z
m
D RAW N BY MMG
04 23 2015
m
REVIEWED BY RWP
04/23/2015
SHEET
1
�
SHEETS
ILLUMINATION PLAN
•
LL
-
O
Z
3
o0
z
m
z
m
I
±: T
Z
z
0
a
D
2
Z
C
ic
co
m
n
- �146_11_tn
W
-
O
D
0
N
N
d
O
0
0
d
I
J
t
N
/
P
C
W
a
L
a
0
U
I
N
O
d
GENERAL NOTES
1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH CITY OF RENTON STANDARDS AND SPECIFICATIONS.
2. THE LOCATIONS OF FEATURES SHOWN ARE APPROXIMATE AND SHALL BE VERIFIED IN THE FIELD BY THE CONTRACTOR PRIOR TO STARTING WORK.
3. ALL WORK SHALL BE CONSISTENT WITH UTILITY AGENCY REQUIREMENTS. THE CONTRACTOR SHALL CONTACT ALL PERTINENT UTILITY AGENCIES 48 HOURS
BEFORE COMMENCING WORK AND SHALL COORDINATE WITH AFFECTED UTILITY AGENCIES THROUGHOUT THE PROJECT.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING UTILITIES. THE CONTRACTOR SHALL NOTIFY THE AFFECTED UTILITY COMPANY
AND THE CITY IMMEDIATELY UPON DAMAGE.
5. STREET LIGHT STANDARD WITH DAVIT MAST ARM SHALL BE INSTALLED PER CITY OF RENTON STANDARD PLAN 115.
6. STREET LIGHT STANDARD FOUNDATIONS SHALL BE INSTALLED PER CITY OF RENTON STANDARD PLAN 115 AND 119.
7. STREET LIGHTS SHALL ADHERE TO CITY OF RENTON STANDARDS.
8. JUNCTION BOXES SHALL BE LOCATED WITHIN 5FT OF LUMINAIRE POLES WHEN FEASIBLE AND SHALL BE INSTALLED OUTSIDE OF SIDEWALK AND DRIVEWAY.
9. POST -TOP FOUNDATIONS AND INSTALLATION SHALL BE COORDINATED WITH THE MANUFACTURER AND SHALL ADHERE TO CITY OF RENTON STANDARD PLAN
116.1 AND 119.
10. INSTALL STREET LIGHT STANDARD DECAL ON EVERY NEW LIGHT STANDARD PER CITY OF RENTON STANDARD PLAN 121.
LUMINARE POLE SCHEDULE
LUMINAIRE
MINIMUM AVERAGE
LIGHT LEVEL (FC)
MAXIMUM UNIFORMITY
RATIO (AVG /MIN)
TARGET
CALCULATED
TARGET
CALCULATED
INTERSECTION
SE 136TH / HOQUTAM AVE
1.2
1.27
POLE
LOCATION STATION
STATION
CPS
POLE OFFSET
MOUNTING
ARM LENGTH
WATTAGE
CIRCUIT NO.
LUMINARIE
4
3.00
REFERENCE
SE 136TH EAST
COORDINATES
(FT)
HEIGHT (FT)
(FT)
(WATTS)
SVC /CKT
POLE NUMBER*
COMMENT
N0.
SE 2ND EAST
0.9
0.98
4
1.63
SE 2ND WEST
0.9
1.03
4
3.43
1
SE 2ND PL /SE 136TH ST
28 +32.5
47.481203281,
_122,153581936
20.0 RT
30
8
94
A/1
6
PER CITY OF RENTON
STANDARD PLAN
2
SE 2ND PL /SE 136TH ST
29 +63.0
47.481199954,
- 122.153055069
20.0 RT
30
8
94
A/1
PER CITY OF RENTON
STANDARD PLAN
3
SE 2ND PL /SE 136TH ST
30 +55.0
47.481197596,
- 122.152682077
20.0 RT
30
8
94
A/1
PER CITY OF RENTON
STANDARD PLAN
4
SE 2ND PL /SE 136TH ST
31 +99.0
47.4811939219
_122,152100769
20.0 RT
30
8
94
A/1
PER CITY OF RENTON
STANDARD PLAN
5
ON -SITE
10 +43.5
47.481135096,
_122,152862557
10.0 LT
14
N/A
44
A/2
PER CITY OF RENTON
STANDARD PLAN
6
ON -SITE
11+46.5
47.480851947,
_122,152964411
16.0 RT
14
N/A
44
A/2
PER CITY OF RENTON
STANDARD PLAN
7
ON -SITE
12 +49.5
47.480570051,
- 122,152831721
16.0 LT
14
N/A
44
A/2
PER CITY OF RENTON
STANDARD PLAN
8
ON -SITE
13 +52.5
47.480286773,
- 122,152957837
16.0 RT
14
N/A
44
A/2
PER CITY OF RENTON
STANDARD PLAN
9
ON -SITE
14 +53.5
47.480009888,
- 122,152954616
16.0 RT
14
N/A
44
A/2
PER CITY OF RENTON
STANDARD PLAN
10
ON-SITE
15 + 44.5
47.479752747,
- 122,152797564
16.0 RT
14
N /A
44
A/2
PER CITY OF RENTON
STANDARD PLAN
11
ON -SITE
16 +36.0
47.479816927,
- 122.152401185
16.0 LT
14
N/A
44
A/2
PER CITY OF RENTON
STANDARD PLAN
1
ON -SITE
17 +28.5
47.479818166,
- 122.152047087
16.0 LT
14
N/A
44
A/2
PER CITY OF RENTON
STANDARD PLAN
1
ON -SITE
18+ 13.0
47.479956174,
- 122,151801438
16.0 RT
14
N/A
44
A/2
PER CITY OF RENTON
STANDARD PLAN
14
ON -SITE
18 +87.5
47.480160397,
_122,151803809
16.0 RT
14
N/A
44
A/2
PER CITY OF RENTON
STANDARD PLAN
15
ON -SITE
19 +61.0
47.480361199,
- 122,151935551
16.0 LT
14
N/A
44
A/2
PER CITY OF RENTON
STANDARD PLAN
16
ON -SITE
20 +55.5
47.480621320,
_122,151809160
16.0 RT
14
N/A
44
A/2
PER CITY OF RENTON
STANDARD PLAN
1
ON -SITE
21 +47.5
47.480872838,
_122,151941492
16.0 LT
14
N/A
44
A/2
PER CITY OF RENTON
STANDARD PLAN
18
ON -SITE
22 +39.5
47.481125738,
- 122,151815017
16.0 RT
14
N/A
44
A/2
PER CITY OF RENTON
STANDARD PLAN
19
SE 2ND PL /SE 136TH ST
32 +91.0
47.481 1 91 564,
_122,151728329
20.0 RT
30
8
94
A/1
PER CITY OF RENTON
STANDARD PLAN
0
SE 2ND PL /SE 136TH ST
33 +80.0
47.481189289,
_122,151369048
20.0 RT
30
8
49
A/1
PER CITY OF RENTON
STANDARD PLAN
2
SE 2ND PL /SE 136TH ST
34 +68.5
47.481187014,
_122,151009768
20.0 RT
30
8
94
A/1
PER CITY OF RENTON
STANDARD PLAN
SE 2ND PL /SE 136TH ST
36 +49.0
47.481177796,
- 122.150281412
21.5 RT
30
8
94
A/1
/
PSE UTILITY POLE
* NUMBER TO BE PROVIDED BY CITY OF RENTON DURING CONSTRUCTION PER CITY OF RENTON STANDARD PLAN 121.
DATE
DESIGNED BY MMG 104/23/2015
DRAWN BY MMG 04/23/2015
REVIEWED BY RWP 104/23/2015
REVISION
mmmmff�m
LIGHT LEVELS
INTERSECTION /ROADWAY
MINIMUM AVERAGE
LIGHT LEVEL (FC)
MAXIMUM UNIFORMITY
RATIO (AVG /MIN)
TARGET
CALCULATED
TARGET
CALCULATED
INTERSECTION
SE 136TH / HOQUTAM AVE
1.2
1.27
4
2.12
SE 2ND PL / ROAD C
1.2
1.24
4
4.13
SE 2ND PL / ROAD A
1.2
1.20
4
3.00
ROADWAY
SE 136TH EAST
0.9
0.94
4
2.35
SE 136TH WEST
0.9
0.97
4
3.23
SE 2ND EAST
0.9
0.98
4
1.63
SE 2ND WEST
0.9
1.03
4
3.43
RESIDENTIAL SIDEWALKS
SIDEWALK 1
0.3
0.28
6
2.80
SIDEWALK 2
0.3
0.24
6
2.40
*LIGHT LEVELS PER CITY OF RENTON CODE SECTION 4 -6 -060.
381402
5/y d /..r
trilanspogroup
Tr
P� � W Sy J'
.� Mao
THE QUADRANT CORPORATION
I L 2
WHAT TRANSPORTATION CAN BE.
^�
��P ° �
�
COPPERWOOD PLAT
C
11730 118TH AVENUE NE, SUITE 600 (TEL) 425 821 -3665
KIRKLAND, WASHINGTON 98034 425 825
A a
�0 F tSrE E�v� �
}
SSfOhAL
IN OF RENTON APRIL 2015
SHEET
2
(FAX) -8434
E� 1�
�
m
m
ILLUMINATION
PLAN
SHEETS
Am
Z
.Z
G7
Z
_=
_'
C
-z
z
m
m
I
:z
z�
z
Z
z
z�
z
rr-
J
0
n
D
Z
Z
C
3
m
1
1
o
_'
d
a
�-i
CD
N
M
N
d
c
2i
0
0
A
3
d
J
i
N
v+
c
G
c
W
/
a
a
U
N
0
d
3.188 WALL BRACKET
ALUM. ALLOY 8063 —T6
11�12" e8NC LOMBOLT
01—LSH
2'
O.D.
TAPERED ALUM, POLE 1.
WALL ALLOY 621163 -T6
SATIN 04OUND F '.NSH
151 HANDHOLE. 4 %6" C
W/C.0" AND S~ S. SCRE
BASE --LM GE ALLOY 301
aaT COVERS S.S. SC
r
ui
S
{
I
i
NOUNliNG
HE 1fiT
f
s
E
NSTALL CECAt, NiM ERS VERTiCA L,
4STALL 'N URY WEAT -4ER, !� ' F DN
A
LNG
� �. x t►ts+tT�iE
4
7'L.A 110EA
• 3/4" '0 2'
1
To
01A. BOLT
C: RCLE
4" CON DXTE PAD
" OF SOLT ABOVE
E1H1SH €3 GRADE
(4) 1 `x42" BK GALY. STEEL
2 112 `
ANCHOR BONS ATH NUTS
:
m
a.
d
t!7
O
N
M
N
d
O
�U
Qp`
C�
O
O
A
d
J_
0'
3
d
J
L
N
O+
C
.0
C
c
W
/
c
C
CL
U
1
N
O
d
1t-6r
4'�
T
'r Y �' s
ETE EAD
=RONT YEW
31— CIS.,
61oM
SIDE VIEW
,, '
VE .T j SIZE T F!T
I- CAg NE T
x
r
� r
0014 ACTS FDLNDAT -ON
_f
I
m04 At
i --
h .' .�
.. a. _. _. Ate bo, ofrw d
- Sn rr In p1.snE
_S4m tat* 3
ji A3opt
X• _.cr mac,
to a-
�.�� dimr: lttt "14 ere,r
1 - Grantor Guth
fl �
� _H(1wi
,.A j4 t" w-,P & V J `� facia
4- .-.-...gym- _
PAD )A"JT PAD MOONT
C ''lP LER !:AN= MUNDAMO N RACM?.lP !&Immd jm Foum'ak7m
Por NCM-S see Std. Plor 126.2
` PUBLIC WOMS CABINET FOUNDATION DETAILS �_ -186.!
"I VEDIARTIVIENT &-.aAA �)Jyln-
r--D+ AME" E R = 7/8"
LCA-d LINE
co
P'I,SE �!T
C1'J ^V V T-1i i
iii T t 'r - C.t
SD— CE- KIT FUSE 10T & VUCE KIT DETALA
ADOPTED
art or jus"m
w &M 44/1)4
3'V�G. NAME: J*13 SP PAG_: Jc1-
.
DATE
104/23/20151
REVISION
BY
DATE
transpogroup
WHAT TRANSPORTATION CAN BE.
11730 118TH AVENUE NE, SUITE 600 (TEL) 425 821 -3665
KIRKLAND, WASHINGTON 98034 (FAX) 425 825 -8434
�
P�,�PW 5� �
.�P�
�� °z�
�0 F t�363 ti0 '�v ,�
ss�ONAL FEU a'
THE QUADRANT CORPORATION
COPPERWOOD PLAT
ITY OF RENTON APRIL 2015
IL4
DESIGNED BY MMG
c
" TZ
DRAWN BY MMG
04/23/2015
REVIEWED BY RWp
04/23/2015
m
z
m
>
SHEET
4
�
SFIEETS
ILLUMINATION
PLAN
.
c
O
m
_
Z
c
" TZ
.z
m
z
m
>
0
- z
Z z C
Z _
z
J'
2
S
Z
2
Z
2
0
D
Z
Z
C
ic
ca
m
_ v '
V
n.
r
N
A �\
O
m
_