HomeMy WebLinkAboutR-382207Lli z '�tt F- >J U CL LLJ ry a 17 U) I 0 J 17 CN7 d- r N 3 N r d' 0 N a 0 C Q z t✓ 0 E 4 V) O 011 43 .(7) W O i� 0 0 _N :2L;j a CN W U- n SURFACE WATER DRAINAGE NOTES AND SPECIFICATIONS 1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRECONSTRUCTION MEETING MUST BE HELD WITH THE CITY OF RENTON PLAN REVIEWER. 2. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE 1996 STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA), AS AMENDED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. 3. THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS, WHICH ARE ON FILE IN THE PUBLIC WORKS DEPARTMENT. ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE WRITTEN APPROVAL FROM THE CITY OF RENTON PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITY SECTION. 4. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 5. DATUM FOR VERTICAL CONTROL SHALL BE NORTH AMERICAN VERTICAL DATUM 1988 METERS, AND FOR HORIZONTAL CONTROL SHALL BE NORTH AMERICAN DATUM 1983/1991 METERS UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. REFERENCE BENCHMARK AND ELEVATIONS ARE NOTED ON THE PLANS. 6. ALL SEDIMENTATION/EROSION FACILITIES MUST BE IN OPERATION PRIOR TO CLEARING AND BUILDING CONSTRUCTION, AND THEY MUST BE SATISFACTORILY MAINTAINED UNTIL CONSTRUCTION IS COMPLETED AND THE POTENTIAL FOR ON-SITE EROSION HAS PASSED. 7. ALL RETENTION/DETENTION FACILITIES MUST BE INSTALLED AND IN OPERATION PRIOR TO OR IN CONJUNCTION WITH ALL CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITY SECTION. 8. GRASS SEED MAY BE APPLIED BY HYDROSEEDING. THE GRASS SEED MIXTURE, OTHER THAN CITY OF RENTON APPROVED STANDARD MIXES, SHALL BE SUBMITTED BY A LANDSCAPE ARCHITECT AND APPROVED BY THE PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITY SECTION. 9. ALL PIPE AND APPURTENANCES SHALL BE LAID ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH SECTION 7-02.3(1) OF THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL, TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. ALL PIPE BEDDING SHALL BE APWA CLASS "C", WITH THE EXCEPTION OF PVC PIPE. ALL TRENCH BACKFILL SHALL BE COMPACTED TO MINIMUM 95% FOR PAVEMENT AND STRUCTURAL FILL AND 90% OTHERWISE PER ASTM D-1557-70. PEA GRAVEL BEDDING SHALL BE 6 INCHES OVER AND UNDER PVC PIPE. 10. GALVANIZED STEEL PIPE AND ALUMINIZED STEEL PIPE FOR ALL DRAINAGE FACILITIES SHALL HAVE ASPHALT TREATMENT #1 OR BETTER INSIDE AND OUTSIDE. 11. STRUCTURES SHALL NOT BE PERMITTED WITHIN 10 FEET OF THE SPRING LINE OF ANY STORM DRAINAGE PIPE, OR 15 FEET FROM THE TOP OF ANY CHANNEL BANK. 12. ALL CATCH BASIN GRATES SHALL BE DEPRESSED 0.10 FEET BELOW PAVEMENT LEVEL. 13. OPEN CUT ROAD CROSSINGS THROUGH EXISTING PUBLIC RIGHT OF WAY WILL NOT BE ALLOWED UNLESS SPECIFICALLY APPROVED BY CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS ADMINISTRATOR. 14. ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A DEPTH OF ONE (1) FOOT AND MUST MEET THE FOLLOWING SPECIFICATIONS: 4 - 8 INCH ROCK / 40 - 70% PASSING; 2 - 4 INCH ROCK / 30 - 40% PASSING; AND LESS THAN 2 INCH ROCK / 10 - 20% PASSING. 15. ALL BUILDING DOWNSPOUTS AND FOOTING DRAINS SHALL BE CONNECTED TO THE STORM DRAINAGE SYSTEM, UNLESS APPROVED BY THE CITY PLAN REVIEWER OR SURFACE WATER UTILITY SECTION. AN ACCURATELY DIMENSIONED, CERTIFIED AS -BUILT DRAWING OF THIS DRAINAGE SYSTEM WILL BE SUBMITTED TO THE CITY UPON COMPLETION. 16. ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY OF RENTON DOES NOT RELIEVE THE OWNER OF THE CONTINUING LEGAL OBLIGATION AND/OR LIABILITY CONNECTED WITH STORM SURFACE WATER DISPOSITION. FURTHER, THE CITY OF RENTON DOES NOT ACCEPT ANY OBLIGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE SYSTEM PROVIDED DURING CONSTRUCTION. 17. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARD, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER NEEDED ACTIONS TO PROTECT THE LIFE, HEALTH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK COVERED BY THE CONTRACT. ANY WORK WITHIN THE TRAVELED RIGHT OF WAY THAT MAY INTERRUPT NORMAL TRAFFIC FLOW SHALL REQUIRE A TRAFFIC CONTROL PLAN APPROVE BY THE PUBLIC WORKS DEPARTMENT, TRANSPORTATION SYSTEMS DIVISION. ALL SECTIONS OF THE WSDOT STANDARD SPECIFICATIONS 1-07-23 TRAFFIC CONTROL SHALL APPLY. 18. SPECIAL DRAINAGE MEASURES WILL BE REQUIRED IF THE PROJECT LOCATION IS WITHIN THE AQUIFER PROTECTION AREA (APA). .-_---_--______-_-____-_ CITY OF RENTON Approved by. .�r ate: Approved by -,2 naw Approved by, .-.._-..----..-. .,_ Date: Approved bv:._ - Datta e` 1: A k i f�V3Y ru ... ww. $' a•.t CEMENTICON RETE H PEDESTRIAN MR, m 4T SO- RAMM ANO LANDINGS ; ,.. , ..,,... FACIA OWAWAdEW3 C E NT CONCRETETRAM i t' . FACk i D ENT 00 2,4. I , I�IVi?I11 ROA A Top Of. AINMWAY OEPR58-ED' CURS ;SE'TION z M A SlDEWI� ;f +11vSNl�YS OIC "t, fid..°.. `'. DEPR ESSED CURB SECT 3iN PACE't 'ktt s 9 AFT SM� WALWMMFS 1..� PAC AC;mtAC8NTCUR9T11 OF ROAMNAY tr f j j aux r R.,, t, t - - •- ;• row y.�,,.a.,�:•�.-,..».�[Mp.��I�M,[��j(��lM}��')♦jpA {{.y. y1��J..4�¢��VJ..'¢�.'pM� 'yN".�D1�')t TSE ! Y •�T" �.A6'i E S� E r. y T RAP EF1C:CURB DEPRESSED CURB DERAIL AT Re$1mN1fP ORf �Mk tAt. O l' WAY& 040 ALLEY �S"�It~1t, �;sDitw z xt 0,0T E3 mat 1 '1, 1Ssr c Las# arts r xY ate sxzcabtzt t�ac usw, iti#r 4 43ras# tdr"! i "ark t ? : P'vmuc 'I� ORY."s IOC. 7 - _------------ - -Y; �..� ., �F�.D� �s.�; Not FrBg #Xtz wto 21MV TP AoJACERTTO CURS' i o • f Y -0- ljzJm mf km �ANG ttt+U P s Auto rte.: s� s�au gore sr ,...„ A te#`i -0 CLM AND RARMG,OR WAS BU�Atg1'#311:'' 9 ib Yes �E ANNOW FLLF911 14%'ea i9WACIE F 6 f,M1•- .c"` �p '�� 4`�•;* Fq' " f tillAMEO fit„ a� $€I43ii F Y we DETAIL t• wV� L ^r � T� •�� .v �, < " �° i�t£a!i lt4;"Ltcti�$�?Ni'B�fi'r a ., z;•• "� .' fi ' For NOT a STD PLM 104 . qq y+! �y ,� '' �.,-,`' `'€ :��x • a ,. r+•�,�, ,�� f�+alV stt�a r'�itt#t'�C2rr1 �sf i$2. . appk*We OC w 'S'To I„AA#+I � F 4• „a, L'+``k� �,. �.�f?�S'�E�k'bid:•f47,'�"aiF3��.'�'(:k$.:iE '� W7,+.At ` a 'r"�t .Ce • y'9b'ai q ;�+�„�;'e, +: i IFIPE ALLOWANCES M41161YAL of R -PIPE REINFORCED OR 13' PLAN COPCF&tE r 0 1 t1• Suiite 144 FRAME AND VANED GRATE S06-20) PER CRY REVIEW COMMENTS Soul) WALL PVC sA'-ter �. �_ ,r' .-� \'�i► 1srD. sPlEc. a-.121)) PER CITY REVIEW COMMENTS PROFILE WALL PVC 1$. (am- mac- 64Xs_12(2)) PER CRY REIAEVIi COMMM CONS%PT F (206) 457-4469�� $ � � �IoSure $ PER CITY - Civil - Structural pro consu.con.7 t NO. REVISION � IV Olt'Ir Cn ... D ONE 83 BAR HOOP FORS' HOWT TYNO #3 BAR HOOPS FOR 12" t laff 7 RL'CTANOUL AR ADJUSItSOW SECTION IFIPE ALLOWANCES M41161YAL of R -PIPE REINFORCED OR 13' PLAN COPCF&tE :F kj ALL METAL PIPE 1 t1• Suiite 144 MP S06-20) PER CRY REVIEW COMMENTS Soul) WALL PVC 18• 1srD. sPlEc. a-.121)) PER CITY REVIEW COMMENTS PROFILE WALL PVC 1$. (am- mac- 64Xs_12(2)) PER CRY REIAEVIi COMMM kr CORRLIGATED POLYETHYLENE STORM SEWER PIPE .�e1 .•,� X i' `�; /- 1. As accepisbie wahn wee to the rdarown the PRECAST BLASE SECTION, titer (placed aotxl'Iding to the ftnftz Sp tfans}, or wire mesh ha ng a mfninasn area of 0.12 square inches pert of shell be used with the mMlmlm required rebarshown in the ALT11RNATM r " / RPWICAST RAW SEC71WN. liMps mesh shall not be placed In the M BAR EACH CORNffi -- � J 2. The knoll cxlt diam Aw shall not be gfeeW 11hon 20'. Knockouts *WI hoe a well thiolmns sof 2' mt*mn b 2.5' max mum. PFwWe a 1.5' min tnurn gale bebsreers the knodwA wag mid its s WW* of the pipe. eAR EACH SIDE-- / ' i Ager the pipe Is ins imie d, fm me gap with joint momr in acoordance - with Standard SpsciAosi on 9-04.3. 3. The maximum depth from the finished grade to the fo*x* pipe invert f �r shall be 5'_ ra BAR EACH WAY -- 4, The trema and grata nmW be InsAaled with the dense dawn. PRECAST BASE'1iWf M #3 MR EACH COMER t8' MIN � B1SR r1as�P 5. The Pnacast Base Section may have a rounded floor, and the walls may be sloped of a rale of 1!24 or steeper. B. The opening; shall be measured al the top of the pnac"base ss dbn, 7. All pickup holes shag be grouted fun afirir fisc basin has Inn pisossd. 8. AI grade rings and caiiw SSteri be Sept in mortar in aaoordance %0 Staandald Sp don 9443. :SEE N=1 ALT'®tMATME PRECAST WASE, SECTION STD. PLAN -- 200.00 ♦ + PUBLIC WORKS CATCH BASIN TYPE 1 DEPARTMENT UARCH 2()013 --- ----- 24• -`k- BOLT -DOM SU DETAIL AND W sl TOP Provide two siva in the cover that are verfivaify aligned With the hales In the fisame.Location of bolt -down Slots 4 3J4'_-- 1 ill' vert is mnxv different "snubokmer3_ 2. Alternative rWn nranfrtg designs are soceptable in lieu of fhsa rib design. HIS 3. Defer t o fyt ndard Specif cation 9-0�5.�15t2o for additional ----- {-- -- requirements W R - SEE Nxif6 2 4, For Frame dermis, see City of Renton 11111111UMN C A) Shnlard Plan 204.00_ f 1J2' ---- __-..__1_.� Tw 0R\ 399 IMAM. HOLE -- 1 • _. _ 112' CUM_ HANDLE MOTION .t , BOLT -11110 i BLOT WTAIL SEE NOTE 1 IsiOEE7711C PU��[,IC WORKS RECTAN0ULAR SOLID STD PLAN -- 2E34.14 ' d ` DEPARTMENT METAL COVER DAARCH 2008 AMS 7/31/13 g X. pZ WAS SURVEYED mv 11/11/113 5628 Al Way :F kj PER CITY REN" COMMENTS Suiite 144 MP 2 PER CRY REVIEW COMMENTS Seattle, WA 98108 CHECKED 3 PER CITY REVIEW COMMENTS P (206) 420-7 30 0�'31 4 PER CRY REIAEVIi COMMM CONS%PT F (206) 457-4469�� $ � � �IoSure $ PER CITY - Civil - Structural pro consu.con.7 t NO. REVISION AMS 7/31/13 MXP SURVEYED mv 11/11/113 MXP ESIGNE DESIGNED- D / AM AMS 3/27/14 WP AMS 10/7/14 MP DRAWN: AMS AMS 2/20/15 MV CHECKED BY DATE AP P R APPROVED: MXP La 4W au• DIA. SMOOTH BAR PIP[ COUPLING -- L SPOT WELD BARS TO AT LEAST 2 CMP OR CPEP SMOG CORREGHTIONS OF METAL PIPE {TYP) INTERIOR BOLT TO CPEP SMOOIT4 INTERIOR PIPE. SIDE VIEW MPE: 1. This debris barrier is for use outside r adimays on pipes 3W die. and smaller. 2 See drawing 223.10 for debris bw t mon pipes pwiecting from drKwasys or mods w aide Japes. 3. All OW parts moat be gehwbmd and mphait mated. (Treabnent 1 or be#we 4. C1111112-srtronth kderior pipe mqukm bob to amara debris border to pipe. ETRIC STD. PLAN - 225.04 PUBLIC WORKS DENS WAIRRIER M + DEPARTMENT - - NfjARC:;H 2008 p CLEAN SURFACE AND BOTTUM AREri PROVIDE UNFORM CONTACT_ THE SURFACE AREA OF THE BABE SECTION MUST BE GRCKJTED TO THE BOTT43M EAOF THE ADJUSTMENT BEOTION. FRAME AND VANM'TIMATE SAIR ONWIN Np'T!S 1. THE COVER OR GRATING OF A CATCH BASIN SHALL. NOT BE GROUTED TO FINAL GRATE UNTIL THE FINAL ELEVATION OF THE PAVEMENT, GUTTER. DITCH, OR swEWALK IN WHICH R IS TO BE PLACED HAS BEEN ESTABLISHED, AND UNTIL PERMISSION THEREAFTER ER IS GP/M BY THE ENGINEER TO GROUT OR CRATING IN PLACE IN ACWRDANCE WITH STANDARD SPECIFICATION 2. SHIMS SHALL NOT BE USED TO SET FRAME TO GRADE, THE USE OF SHIMS IS PROHIBITED. 3. MORTAR SHALL BE PLACED BETWEEN ADJUSTMENT RINGS AND BRICKS PRIOR TO PLACEMEN, 4. THE USE OF BRICKS IS PERMITTED WHERE THE BRICKS ARE STAGGERED TO CREATE A RUNNING BOND OR 3'z BOND. SEE NOTE 4 STD. PLAN -- 202 00 PU I LIC WORKS CATCH BASIN INSTALLATION M + I7EPAR`1'MEN'h Mr1hRC.',H 2008 SCALE: VERTICAL: NAVD 1988 SEE GRAPHIC HORIZONTAL: NAD 1983/1991 CITY OF RENTON ONE INCH 1 DATUM AT FULL SCALE 1Planning/Building/Public Works Dept. IF NOT ONE INCH SCALE ACCORDINGLY �I wP. .Pf$"b'k uC sss-���a z �•��+�rzr��a.s+rzt�s,� y ,,,�� r err T S R 4 `I'YP 1 jWMETMC'VIE #WT- SUI TAIL iIF i i AND NM I I f A , 20+ i IS- .. t f"IEIC�"1"It;Ii11 { 11 Pic - 4 _ { ... - 1fN�7iItE'1"t#11C PUBLICS WORKS DEPARTMENT E I 114.'.. trawl R� ++ t St ' i #IST»IIP m%W NT.I IL t ProvlGe two skrtfl in the gnift that anti vwftdy altgned with to t1dm In 'rifle froths. t ooell s of #x211 damn A* 2 RelW to &ondtn'd BpeditaUt 8--05,1 ) for snit r8gtlt'renle. 3. Unless adhemise specliied, vaned Wallas shall be used whh standard tome In the trial W&I, putter or atlt iWer. varod SmAn OW not be lorrated within cxraes mads. Use vaned grata *WV rallied curbs. IUMTAIrNAiiL" F 204,20 V'`AItiIID I"a1RATE.....�...ri...._.w......-.,...�._�.., MARCH 2008 R-382101 HIGHLANDS PARK SHORT PLAT (013001144) �g/12/201` 6200 SE 2ND PL, RENTON, WA FlElDB00K: PAGE: STORM DRAINAGE NOTES &DETAILS DRAWING NO: 024-12 SHEET-7 OF: � • z a z 5 Z D 01 C O d O Cr 3 -0 CD t- o 0. J K �rn b a �N m N m z D m T71 Cn D 7 D O 210 C7 C Cn D �m :UO U z mz m 01 O D Cn I� D 01 O d O Cr O CD t- o 0. J O CD 0 b a �N m N Cn D C7 O O M m zoC D T71 Cn � 7