HomeMy WebLinkAboutT-373904O N T O O d' T H Q J 0 Z O z w Ir A PORTION OF THE NE 1/4 OF THE NE 1/4 OF SECTION 15, TOWNSHIP 23 N., RANGE 5 EAST, W.M., CITY OF RENTON, WASHINGTON CONSTRUCTION NOTES 1. ALL WORKMANSHIP AND MATERIAL SHALL BE IN ACCORDANCE WITH THE CITY OF RENTON DESIGN STANDARDS AND SPECIFICATION. THE APPROPRIATE STATE ELECTRICAL CODES AND THE PROVISIONS OF THE LATEST EDITION OF THE IES LIGHTING HANDBOOK 2. ALL WORK ON THE LIGHTING SYSTEM SHALL BE COMPLETED BY LICENSED CONTRACTORS EXPERIENCED IN THE INSTALLATION OF ILLUMINATION SYSTEMS. 3. THE CONTRACTOR SHALL SECURE ALL REQUIRED PERMITS AND COORDINATE INSPECTION WITH THE CITY, STATE AND POWER COMPANY AS REQUIRED. 4. CONTRACTOR SHALL CONTACT CITY INSPECTOR A MINIMUM OF 24—HOURS PRIOR TO COMMENCING WORK ON THE LIGHTING SYSTEM. 5. CONTRACTOR SHALL CONTACT PUGET SOUND ENERGY (PSE) FOR POWER DESIGN. 6. CONTRACTOR TO COORDINATE WITH ERIC CATSHALL, COR TRANSPORTATION MAINTENANCE ASSIST. MAGR, 425-430-7423 FOR SERVICE CABINET ELECTRIC HOOKUP. THE POINT OF SERVICE FROM PSE SHALL BE A MAXIMUM OF 50 FEET FROM THE PROPOSED SERVICE CABINET. IF GREATER A HANDHOLE IS REQUIRED. LABEL BACK OF SERVICE CABINET WITH ADDRESS, (SEE STD. PLAN #123.1). 7. INSTALL TYPE 1 JUNCTION BOX W/ CONCRETE PAD ON NORTH SIDE OF NEW SERVICE CABINET. POLE ID. NUMBER TO BE ADDED AT TIME OF CONSTRUCTION POWER SOURCE FROM PSE, COORDINATE AT TIME OF POWER APPLICATION LABEL BACK SIDE OF NEW SERVICE CABINET WITH NOTE,. EXISTING UTILITY L❑CATI❑NS SHOWN HEREON ARE APPROXIMATE ONLY, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE EXACT VERTICAL AND HORIZONTAL LOCATION OF ALL EXISTING UNDERGROUND UTILIITES PRIOR TO COMMENCING CONSTRUCTI❑N, NO REPRESENTATI❑N IS MADE THAT ALL EXISTING UTILITIES ARE SHOWN HEREON. THE ENGINEER ASSUMES NO RESPONSIBILITY FOR UTILITIES NOT SHOWN OR UTILITIES NOT SHOWN IN THEIR PROPER LOCATION, CALL BEFORE YOU DIG.- 811 2" STRE CONDUIT `J� \INT'X STATIONING: STA. 20+43.55, NILE AVENUE NE STA. 30+00.00, NE 2nd COURT RUN N0. CONDUIT WIRING AFI erg . IGHT 3- #8 T.H. W. COPPER ILLUMINATION POLE SCHEDULE PVC SCH. 80 o o 31 �� zq = J crZ 44h, CD z POLE NO. STREET POLE STATION OFFSET MOUNT VOLTAGE WATTAGE/ LUMINAIRE TYPE BASE } 1 COMMENTS W. t f ID NO. x $! HEIGHT TYPE DISTRIBUTION 0 r LP#1 Y$ 2nd COURT f!, 30+44.0 17.0' LT. t, eek I r— — PRESTIGE — — CY17TA VS3AR 3L 44W 4K 1l /Q�� W POLE NE 2nd COURT w PLAN #116.1 r NE 2nd COURT 30+93.0 17.0' RT. 14' 240 44 LED C19 4 K FIXED NEW {,r PER STD. f #116.1 rr. { PRESTIGE �f W LP 3 # NE 2nd COURT 31 +50.0 17.0' LT. 14' 240 44 LED W 4K FIXED NEW POLE PER STD. PLAN #116.1 W 7 r LP#4 NE 2nd COURT rr �r Lu RT. 14, 240 44 LED — — — CY17TA VS3AR 3L 44W 4K FIXED NEW POLE PER STD. PLAN f LP#5 flh T {! ^w y' ! G r 32+50.0 2" STRE CONDUIT `J� \INT'X STATIONING: STA. 20+43.55, NILE AVENUE NE STA. 30+00.00, NE 2nd COURT OFFE ENGINEERS 13932 SOUTHEAST 159TH PLACE RENTON, WASHINGTON 98058 PHONE: 425-260-3412 CONTACT: DARRELL OFFE, P.E. L. 4,00 0010 0 00 0 00 O° � y° a° ° o° o ..� o. 0 . 2 ° o ° 27460 e o° 0 004,00 G/STEF?�°°�� 1 N000 AL ° �'� 09/22/2014 NO. RELOCATED LP#6 DUE TO EX. UTILITIES ADDED ILLUMINAIRE AT ENTRY REVISION SURVEYED: SURVEYED DESIGNED: D.L. OFFE, P.E. DLO 09/19/14 DRAWN: D.L. OFFE, P.E. DLO 08/11/14 CHECKED: BY DATE AP P R APPS: i STREET LIGHTING SYSTEM TO BE INSTALLED UNDER A SEPERATE ELECTRICAL PERMIT RUN N0. CONDUIT WIRING X erg . IGHT 3- #8 T.H. W. COPPER ILLUMINATION POLE SCHEDULE PVC SCH. 80 o o 31 �� zq = J crZ 44h, CD z POLE NO. STREET POLE STATION OFFSET MOUNT VOLTAGE WATTAGE/ LUMINAIRE TYPE BASE COMMENTS t f ID NO. HEIGHT TYPE DISTRIBUTION r LP#1 NE 2nd COURT 30+44.0 17.0' LT. 14' 240 44 LED — PRESTIGE — — CY17TA VS3AR 3L 44W 4K FIXED NEW POLE PER STD. PLAN #116.1 LP 2 NE 2nd COURT 30+93.0 17.0' RT. 14' 240 44 LED — PRESTIGE — — CY 17TA VS 3AR 3 L 44W 4 K FIXED NEW POLE PER STD. PLAN #116.1 PRESTIGE LP 3 # NE 2nd COURT 31 +50.0 17.0' LT. 14' 240 44 LED — — CY17TA—VS3AR 3L 44W 4K FIXED NEW POLE PER STD. PLAN #116.1 PRESTIGE LP#4 NE 2nd COURT 32+16.0 17.0 RT. 14, 240 44 LED — — — CY17TA VS3AR 3L 44W 4K FIXED NEW POLE PER STD. PLAN #116.1 LP#5 NE 2nd COURT 32+50.0 17.0' RT. 14' 240 44 LEDPRESTIGE — — CY17TA—VS3AR 3L 44W 4K FIXED NEW POLE PER STD. PLAN #116.1 LP#6 NILE AVE. NE 20+87.66 17.0' RT. 35' 240 94 LED ATBO 40BLEDE70 MVOLT R3 NL 700 mA DRIVER FIXED NEW POLE PER STD. PLAN #115 OFFE ENGINEERS 13932 SOUTHEAST 159TH PLACE RENTON, WASHINGTON 98058 PHONE: 425-260-3412 CONTACT: DARRELL OFFE, P.E. L. 4,00 0010 0 00 0 00 O° � y° a° ° o° o ..� o. 0 . 2 ° o ° 27460 e o° 0 004,00 G/STEF?�°°�� 1 N000 AL ° �'� 09/22/2014 NO. RELOCATED LP#6 DUE TO EX. UTILITIES ADDED ILLUMINAIRE AT ENTRY REVISION SURVEYED: SURVEYED DESIGNED: D.L. OFFE, P.E. DLO 09/19/14 DRAWN: D.L. OFFE, P.E. DLO 08/11/14 CHECKED: BY DATE AP P R APPS: i STREET LIGHTING SYSTEM TO BE INSTALLED UNDER A SEPERATE ELECTRICAL PERMIT [u.•.0 ENLARGEMENT OF INTERSECTION SCALE: 1 "=10" T=171QAA GRAPHIC SCALE USE SCHEDULE 40 PVC UNDER SIDEWALKS, o 15 30 so USE SCHEDULE 80 PVC UNDER PAVED AREAS. -T I NJ 1 inch = 30 feet CONDUIT AND WIRING SCHEDULE RUN N0. CONDUIT WIRING X erg . IGHT 3- #8 T.H. W. COPPER 2�2" PVC SCH. 80 o o 31 �� zq = J crZ 44h, CD z J N t1 r G7 t f r [u.•.0 ENLARGEMENT OF INTERSECTION SCALE: 1 "=10" T=171QAA GRAPHIC SCALE USE SCHEDULE 40 PVC UNDER SIDEWALKS, o 15 30 so USE SCHEDULE 80 PVC UNDER PAVED AREAS. -T I NJ 1 inch = 30 feet CONDUIT AND WIRING SCHEDULE RUN N0. CONDUIT WIRING 1� 2 " PVC SCH. 40 3- #8 T.H. W. COPPER 2�2" PVC SCH. 80 3- #8 T.H. W. COPPER SCALE ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDIINMY VERMAL: NAVD 1988 HORIZONTAL: NAD 1983/1991 DATUM CITY OE RENTON Planning/Building/Public Works Dept. -"4 ��, 1 Checked for Compliance to City Standards RENTON 7 SHORT PLAT JAYMARC HOMES, LLC STREET LIGHTING PLAN NE 2nd COURT/NILE AVENUE NE 09/22/2014 RELD80OK: PAGE DRAWING N0: L-1 SHS` 13 OF- 15 '7NIC z m R � � o J o 31 �� zq = J crZ 44h, CD z w z � J Q M z r G7