Loading...
HomeMy WebLinkAboutW-375103CV CY) T T 0 C:) T _TEMPORARY 2' GALVANIZED PIPE AND 2' GATE VALVE FINISHED GRADE ELEVATI❑N - - � - - " "A "I 1 "* INSTALL 2' PLUG ON TOP BLIND FLANGE 3 FT MIN, COVER (10—INCH DIAMETER AND UNDER) AFTER REMOVAL OF POLYPIG 4 FT MIN, COVER (12—INCH DIAMETER AND OVER) I 4 ' J NEW WATER MAIN POLYPIG ,^ 04. a a n ad v VERTICAL CROSS FOR PGL_YPIGGING STATION: SIZE OF VERTICAL CROSS SHALL BE THE SAME AS SIZE OF MAIN LINE VERTICAL CROSS CMJ X FL) 4" END CAP MJ ONE BLIND FLANGE ON TOP OF CROSS WITH 2' TAP & 2' TEMPORARY BLOW -OFF ASSEMBLY -2r'-PERM. BLOW OFF (REMOVE BLOW -OFF ASSEMBLY AND INSTALL 2' PLUG AFTER REMOVAL OF CLEANING 'POLY -PIG') CONCRETE BLOCK ONE BLIND FLANGE ON BOTTOM OF CROSS PER CITY OF RENTON ONE PLUG (MJ) ON END OF CROSS STANDARD DETAIL #340.1 CONCRETE BLOCKING ALL DEBRIS AND P❑LYPIGS SHALL BE REMOVED FROM SUMP OF VERTICAL CROSS BEFORE DISINFECTION OF NEW WATER MAIN ALL WATER SERVICES S HALL BE 1 " SERVICE LINE PER CITY STANDARD DETAIL #320.1 ALL WATER METERS SHALL BE 3/4" IN SIZE EXISTING UTILITY L❑CATI❑NS SHOWN HEREON ARE APPROXIMATE ONLY, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE EXACT VERTICAL AND HORIZONTAL LOCATI❑N OF ALL EXISTING UNDERGROUND UTILIITES PRIOR TO COMMENCING CONSTRUCTION, NO REPRESENTATION IS MADE THAT ALL EXISTING UTILITIES ARE SHOWN HEREON, THE ENGINEER ASSUMES NO RESPONSIBILITY FOR UTILITIES NOT SHOWN OR UTILITIES NOT SHOWN IN THEIR PROPER LOCATION, CALL BEFORE YOU DIG: 811 CUT AND CAP 3—EXISTING SERVICES AT WATER MAIN, UNDER SEPARATE PERMIT, BY CITY FORCES. CALL 811 BEFORE YOU DIG! INTERSECTION FE ,.,& STA. 10+00 OFFE ENGINEERS 13932 SOUTHEAST 159TH PLACE RENTON, WASHINGTON 98058 PHONE: 425-260-3412 CONTACT: DARRELL OFFE, P.E. 1 " COPPER SERVICE (TYPICAQ/ STA. 12+95.0, 51T. / SEE NOTE BOTTOMOF HYDRANT FLANGE=451.60 1-8 x6�� TEE (MJxFL) 1—FIRE HYDRANT ASSEMBLY 1-6" GATE VALVE (FLxMJ) 1-8"x4" REDUCER (MJxMJ) 1-4" GATE VALVE (MJxMJ) 1—CONCRETE BLOCK J NOTE: ALL TRENCH RESTORATION SHALL BE PER CURRENT w CITY OF RENTON STREET OVERLAY AND TRENCH RESTORATION DETAIL UNAL 05/20/2015 1 N0. 7 201101 MOL SURVEYED: HANSEN SURVEYING DESIGNED: D.L. OFFE, P.E. DRAWN: D.L. OFFE, P.E. CHECKED: BY DATE I APPR APPROVED: SCALE ONE INCH AT FULL SCALE IF NOT OPE INCH SCALE ACCORDNI VERWA_ NAVD 1988 HORIZONTAL- W I W/, ilil, DATUM 4% "R CITY OE RENTON Planning/Building/Public Works Dept. �,, � t '!` '° L./// °� ✓� .gee.^/ GRAPHIC SCALE 0 15 30 60 1 inch = 30 feet W-3 75103 AS -BUILT 05/20/2015 MAY CREEK COURT SHORT PLAT VINEYARDS CONSTRUCTION, LLC WATER PLAN & PROFILE 2530 DUVALL AVENUE NE 05/20/2015 FIElDOWK: PACE: DRAWING NO: SHM' 9 OR R12 � uJ > z Z C 7 z m z m m Cn 0 D D T n 0 0 0 z m I M z z m MINIMUM (Ty P �i o � RY U�_ 36: B 450 ,.cam-� �3 � .. ........... ...,..... .. .. .. ..... .. ...... .. , ... . ...... .. , .. .. ........ .... ......... ...... g.. D M 450 . ,.. .. �1.�... _ ,. . .............. r 1 q.7LF 00 z o� +v o r �w 440 .w : 1 440 �z W : �` z F ., 430 . . UJ . . a 420 . . . . w .:........ . . 420 10+00 [ 1 1+00 12+00 l 13+00 14+00 UNAL 05/20/2015 1 N0. 7 201101 MOL SURVEYED: HANSEN SURVEYING DESIGNED: D.L. OFFE, P.E. DRAWN: D.L. OFFE, P.E. CHECKED: BY DATE I APPR APPROVED: SCALE ONE INCH AT FULL SCALE IF NOT OPE INCH SCALE ACCORDNI VERWA_ NAVD 1988 HORIZONTAL- W I W/, ilil, DATUM 4% "R CITY OE RENTON Planning/Building/Public Works Dept. �,, � t '!` '° L./// °� ✓� .gee.^/ GRAPHIC SCALE 0 15 30 60 1 inch = 30 feet W-3 75103 AS -BUILT 05/20/2015 MAY CREEK COURT SHORT PLAT VINEYARDS CONSTRUCTION, LLC WATER PLAN & PROFILE 2530 DUVALL AVENUE NE 05/20/2015 FIElDOWK: PACE: DRAWING NO: SHM' 9 OR R12 � uJ > z Z C 7 z m z m m Cn 0 D D T n 0 0 0 z m I M z z m D C7 O 0 n o m J � ,C o � J CD z o m� r D C7 O 0 n o m J � ,C