DRIVEWAYS SHALL BE PAVED TO THE EDGE
OF R -O -W PRIOR TO INSTALLATION OF THE
CONSTRUCTION ENTRANCE TO AVOID
DAMAGING OF THE ROADWAY
IT IS RECOMMENDED THAT THE
ENTRANCE BE CROWNED SO THAT
RUNOFF DRAINS OFF THE PAD
f
INSTALL DRIVEWAY CULVERT IF THERE
IS A ROADSIDE DITCH PRESENT, AS
PER CITY ROAD STANDARDS
4"-8" QUARRY SPALLS
GEOTEXTILE
12" MIN. THICKNESS PROVIDE FULL WIDTH OF
NOTES INGRESS/EGRESS AREA
1. CONDITION OF USE
1.1. CONSTRUCTION ENTRANCE SHALL BE STABILIZED WHEREVER TRAFFIC WILL BE LEAVING A CONSTRUCTION SITE AND TRAVELING ON
PAVED ROADS OR OTHER PAVED AREAS WITHIN 1,000 FEET OF THE SITE.
GRAB TENSILE STREBNGTH (ASTM D4751)
200 PSI MIN.
GRAB TENSILE ELONGATION (ASTM D4632)
30% MAX.
MULLEN BURSTSTRENGTH ASTM D3786 -80A
400 PSI MIN.
AOS (ASTM D4751)
20-45 (U.S. STANDARD SIEVE SIZE)
2. DESIGN AND INSTALLATION SPECIFICATIONS
2.1. HOG FUEL (WOOD BASED MULCH) MAY BE SUBSTITUTED FOR OR COMBINED WITH QUARRY SPALLS IN ARES THAT WILL BOT BE USED
FOR PERMANENT ROADS. HOG FUEL IS NOT RECOMMENDED FOR ENTRANCE STABILIZATION IN URBAN AREAS. THE INSPECTOR MAY
AT ANY TIME REQUIRE THE USE OF QUARRY SPALLS IF THE HOG FUEL IS NOT PREVENTING SEDIMENT FROM BEING TRACKED ONTO
PAVEMENT OR IF THE HOG FUEL IS BEING CARRIED ONTO PAVEMENT.
2.2. FENCING SHALL BE INSTALLED AS NECESSARY TO RESTRICT TRAFFIC TO THE CONSTRUCTION ENTRANCE.
2.3. WHENEVER POSSIBLE, THE ENTRANCE SHALL BE CONSTRUCTED ON A FIRM, COMPACTED SUBGRADE. THIS CAN SUBSTANTIALLY
INCREASE THE EFFECTIVENESS OF THE PAD AND REDUCE THE NEED FOR MAINTENANCE.
3. MAINTENANCE STANDARDS
3.1. QUARRY SPALLS SHALL BE ADDED IF THE PAD IS NO LONGER IN ACCORDANCE WITH THE SPECIFICATIONS.
3.2. IF THE ENTRANCE IS NOT PREVENTING SEDIMENT BEING TRACKED ONTO PAVEMENT, THEN ALTERNATIVE MEASURES TO KEEP THE
STREETS FREE OF SEDIMENT SHALL BE USED. THIS MAY INCLUDE STREET SWEEPING, AN INCREASE IN THE DIMENSIONS OF THE
ENTRANCE, OR THE INSTALLATION OF THE WHEEL WASH. IF WASHING IS USED, IT SHALL BE DONE ON AN AREA COVERED WITH
CRUSHED ROCK, AND WASHED WATER SHALL DRAIN TO A SEDIMENT TRAP OR POND.
3.3. ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED IMMEDIATELY BY SWEEPING. THE SEDIMENT COLLECTED BY
SWEEPING SHALL BE REMOVED OR STABILIZED ON SITE. THE PAVEMENT SHALL NOT BE CLEANED BY WASHING DOWN THE STREET,
EXCEPT WHEN SWEEPING IS INEFFECTIVE AND THERE IS A THREAT TO PUBLIC SAFETY. IF IT NECESSARY TO WASH THE STREETS, A
SMALL SUMP MUST BE CONDUCTED. THE SEDIMENT WOULD THEN BE WASHED INTO THE SUMP WHERE IT CAN BE CONTROLLED AND
DISCHARGED APPROPRIATELY.
3.4. ANY QUARRY SPALLS THAT ARE LOOSENED FROM THE PAD AND END UP ON THE ROADWAY SHALL BE REMOVED IMMEDIATELY.
3.5. IF VEHICLES ARE ENTERING OR EXITING THE SITES AT POINTS OTHER THAN THE CONSTRUCTION ENTRANCE(S), FENCING SHALL BE
INSTALLED TO CONTROL TRAFFIC.
m
0
�'�Y STD. PLAN — 215.10
PUBLIC WORKS STABILIZED
` n ' DEPARTMENT CONSTRUCTION ENTRANCE
MARCH 2008
JOINTS IN FILTER FABRIC SHALL BE SPLICED
AT POSTS. USE STAPLES, WIRE RINGS, OR
EOUIVALF_NT TO ATTACH FAFRIC TO POSTS.
2"x2" BY 14 Ga. WIRE OR
EQUIVALENT, IF STANDARD
STRENGTH FABRIC USED
FILTER FABRIC 0-
I
6' MAX.
U
Date:'
POST SPACING MAY BE INCREASED
��
MINIMUM 4"x4" TRENCH
TO BAF WIRE BACKING IS USED
BACKFILL TRENCH WITH
2"x2" BY 14 Ga. WIRE OR
EQUIVALENT, IF STANDARD
STRENGTH FABRIC USED
FILTER FABRIC 0-
I
I
BY.
Date:'
BY:
��
MINIMUM 4"x4" TRENCH
BY:
BACKFILL TRENCH WITH
BY:
NATIVE SOIL
2"x4" WOOD POSTS, STEEL FENCE
POSTS, REBAR, OR EQUIVALENT
z
(V
NOTES
1. CONDITION OF USE
1.1. SILT FENCE MAY BE USED DOWNSLOPE OF ALL DISTURBED AREAS.
1.2. SILT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR IS INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW.
ANY CONCENTRATED FLOW MOST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR POND.
2. DESIGN AND INSTALLATION SPECIFICATIONS
2.1. THE GEOTEXTILE USED MOST MET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MOST BE
AVAILABLE ON SITE.
AOS (ASTM D4751) 30-100SIEVE SIZE (0.60-0.15MM) FOR SILT FILM
50-100 SIEVE SIZE (0.30-0.15MM) FOR OTHER FABRICS
WATER PERMITTIVITY ASTM D491 0.02SECA-1 MINIMUM
GRAB TENSILE STRENCHT (ASTM D4632) 180 LBS. MIN. FOR EXTRA STRENGH FABRIC
100 LBS. MIN. FOR STANDARD STRENGHT FABRIC
GRAB TENSILE ELONGATION ASTM D4632)130 % MAX.
ULTRAVIOLATE RESISTANCE(ASTM D4355) 70%MIN,
2.2. STANDARD STRENGTH FABRIC REQUIRES WIRE BACKING TO INCREASE THE STRENGTH OF THE FENCE. WIRE BACKING OR CLOSER POST
SPACING MAY BE REQUIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE,
2.3. WHERE THE FENCE IS INSTALLED, THE SLOPE SHALL NOT BE STEEPER THAN 2H:1V
2.4. IF A TYPICAL SILT FENCE IS USED, THE STANDARD 4X4 TRENCH MAY NOT BE REDUCED AS LONG AS THE BOTTOM 8 INCHES OF THE SILT FENCE
IS WELL BURIED AND SECURE IN A TRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT
FENCE.
3. MAINTENANCE STANDARDS
3.1. ANY DAMAGE SHALL BE REPAIR IMMEDIATELY.
3.2. IF CONCENTRATED FLOES ARE EVIDENT UPHILL OD THE FENCE, THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND.
3.3. IT IS IMPORTANT TO CHECK THE UPHILL SIDE OF THE FENCE FOR SIGNS OF THE FENCE CLOGGING AND ACTING AS A BARRIER TO FLOW AND
THEN CAUSING CHANNELIZATION OF FLOWS PARALLEL TO THE FENCE. IF THIS OCCURS, REPLACE THE FENCE OR REMOVED THE TRAP
SEDIMENT.
3.4. SEDIMENT MOST BE REMOVED WHEN SEDIMENT IS 6 INCHES HIGH.
3.5. IF THE FILTER FABRIC (GEOTEXTILE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN, IT SHALL BE REPLACED.
Y O
+ A + PUBLIC WORKS
DEPARTMENT
Call 2 Working Days Before You Dig
811
Utilities Underground Location Center
(ID,MT,ND,OR,WA)
SILT FENCE
STD. PLAN — 214.00
MARCH 2008
VV
HOLDINGS LLC
SE 1/4 SECTION 3, TOWNSHIP 23 N, RANGE 5 E, W.M.
MA ER TINS RANCH
5" MAX.
D DRAINAGE GRATE TRIM
GRATE FRAME
m
v a d
o o ..
SEDIMENT AND DEBRIS
a OVERFLOW BYPASS
BELOW INLET GRATE DEVICE
v
FILTERED
WATER
A
D D
o• o
D D
,D • D O D
SECTION VIEW
DRAINAGE GRATE
RECTANGULAR GRATE SHOWN RETRIEVAL SYSTEM (TYP.)
BELOW INLET GRATE DEVICE OVERFLOW BYPASS (TYP.)
ISOMETRIC VIEW
NOTES
1. Size the Below Inlet Grate Device (BIGD) for the storm water structure it will service.
2. The BIGD shall have a built -In high-flow relief system (overflow bypass).
3. The retrieval system must allow removal of the BIGD without spilling the collected material.
4. Perform maintenance in accordance with Standard Specification 8-01.3(15).
�ZY O STD. PLAN — 216.30
+PUBLIC WORKS CATCH BASIN FILTER
DEPARTMENT MARCH 2008
D.R. STRONG
CONSUL TING ENGINEERS
ENGINEERS PLANNERS SURVEYORS
620 - 7TH AVENUE, KIRKLAND, WA 98033 FN
0 425.827.3063 F 425.827 2423
2:1 MAX. SLOPE
Y
S _
Z LEVEL BOTTOMI—
a 1' MIN. rrr_
_ = I�IIIIII,i�l—,III_ II
-
-1
2' MIN.
r�
SWALE SPACING DEPENDS ON SLOPE GRADIENT
NOTES
1. CONDITION OF USE
1.1. REQUIRED AT:
1.1.1. THE TOP OF ALL SLOPES IN EXCESS OF 3H: IV AND WITH MORE THAN 20 FEET OF VERTICAL RELIEF.
1.1.2. AT INTERVALS ON ANY SLOPES THAT EXCEEDS THE DIMENSIONS SPECIFIED BELLOW.
AVERAGE SLOPE SLOPE PERCENT FLOWPATH LENGTH
20H: 1V 3-5% 300 FEET
(10 TO 20) H: IV 5-100/0 200 FEET
(4 TO 10 H: IV 10-25% 100 FEET
(2 TO 4)H:1V 25-50% 50 FEET
2. DESIGN AND INSTALLATION SPECIFICATIONS
2,1. FOR SLOPES STEEPER THAN 2H: IV WITH MORE THAN 10 FEET OF VERTICAL RELIEF, BENCHES MAY BE CONSTRUCTED OR CLOSER
SPACED INTERCEPTOR SWALES MAY BE USED. THE DESIRE MEASURE MOST BE DESIGNED BY AN ENGINEER TO EFFECTIVELY
INTERCEPT THE HIGH VELOCITY RUNOFF TO A SEDIMENT POND OR TRAP.
2.2. CONSTRUCTION TRAFFIC OVER TEMPORARY SWALES SHALL BE MINIMIZED.
3, MAINTENANCE STANDARDS
3.1. DAMAGE RESULTING FROM RUNOFF OR CONSTRUCTION ACTIVITY SHALL BE REPAIRED IMMEDIATELY.
3.2. IF THE FACILITY DO NOT REGULARLY RETAIN STORM RUNOFF, THE CAPACITY AND/OR FREQUENCY OF THE SWALES SHALL BE
INCREASED.
Y O STD. PLAN — 217.10
+ + PUBLIC WORKS INTERCEPTOR SWALE
LENDEPARTMENT
MARCH 2008
TREE PRD TEC TION MEASURES
0. CONSTRUCTION STORAGE PROHIBITED: THE APPLICANT MAY NOT FILL, EXCA VA TE, STACK
OR STORE ANY EQUIPMENT, DISPOSE OF ANY MATERIALS, SUPPLIES OR FLUIDS, OPERATE ANY
EQUIPMENT, INSTALL IMPERVIOUS SURFACES, OR COMPACT THE EARTH IN ANY WAY WITHIN THE
AREA DEFINED BY THE DRIP LINE OF ANY TREE TO BE RETAINED.
b. FENCED PROTECTION AREA REQUIRED: THE APPLICANT SHALL ERECT AND MAINTAIN SIX
FOOT (6) HIGH CHAIN LINK TEMPORARY CONSTRUCTION FENCING AROUND THE DRIP LINES OF
ALL RETAINED TREES, OR ALONG THE PERIMETER OF A STAND OF RETAINED TREES. PLACARDS
SHALL BE PLACED ON FENCING EVERY FIFTY FEET (50) INDICATING THE WORDS, "NO
TRESPASSING — PROTECTED TREES" OR ON EACH SIDE OF THE FENCING IF LESS THAN FIFTY
FEET (50'). SITE ACCESS TO INDIVIDUALLY PROTECTED TREES OR GROUPS OF TREES SHALL BE
FENCED AND SIGNED. INDIVIDUAL TREES SHALL BE FENCED ON FOUR (4) SIDES. IN ADDITION,
THE APPLICANT SHALL PROVIDE SUPERVISION WHENEVER EQUIPMENT OR TRUCKS ARE MOVING
NEAR TREES
C. PROTECTION FROM GRADE CHANGES. IF THE GRADE LEVEL ADJOINING TO A TREE TO BE
RETAINED IS TO BE RAISED, THE APPLICANT SHALL CONSTRUCT A DRY ROCK WALL OR ROCK
WELL AROUND THE TREE. THE DIAMETER OF THIS WALL OR WELL MUST BE EQUAL TO THE
TREE'S DRIP LINE.
d. IMPERVIOUS SURFACES PROHIBITED WITHIN THE DRIP LINE. THE APPLICANT MAY NOT
INSTALL IMPERVIOUS SURFACE MATERIAL WITHIN THE AREA DEFINED BY THE DRIP LINE OF ANY
TREE TO BE RETAINED.
e. RESTRICTIONS ON GRADING WITHIN THE DRIP LINES OF RETAINED TREES. THE GRADE
LEVEL AROUND ANY TREE TO BE RETAINED MAY NOT BE LOWERED WITHIN THE GREATER OF
THE FOLLOWING AREAS. (l) THE AREA DEFINED BY THE DRIP LINE OF THE TREE, OR (ll) AN
AREA AROUND THE TREE EQUAL TO ONE AND ONE—HALF FEET (1-1/2) IN DIAMETER FOR
EACH ONE INCH OF TREE CALIPER. THE REVIEWING OFFICIAL MAY REQUIRE A LARGER TREE
PRO TEC TION ZONE BASED ON TREE SIZE, SPECIES, SOIL, OR OTHER CONDITIONS
f. MULCH LAYER REQUIRED: ALL AREAS WITHIN THE REQUIRED FENCING SHALL BE COVERED
COMPLETELY AND EVENLY WITH A MINIMUM OF THREE INCHES (J') OF BARK MULCH PRIOR TO
INS TALLA TION OF THE PRO TEC TI VE FENCING. EXCEPTIONS MAY BE APPROVED BY THE REVIEWING
OFFICIAL IF THE MULCH WILL ADVERSELY AFFECT PROTECTED GROUND COVER PLANTS
g. MONITORING REQUIRED DURING CONSTRUCTION. THE APPLICANT SHALL RETAIN A
PROFESSIONAL ARBORIST OR OTHER QUALIFIED PROFESSIONAL TO PRUNE BRANCHES AND
ROOTS, FERTILIZE, AND WATER AS APPROPRIATE FOR ANY TREES AND GROUND COVER WHICH
ARE TO BE RETAINED.
M 11 LP 07.13.15 � SURVEYED:
riM
sis
DESIGNED:,,••
DRAWN: Wx
CHECKED:
REVISION BY DATE AP P R APPROVED:
SCALE:
AS NOTED
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
NOTES:
Y
ROCK MUST COMPLETELY COVER THE
m BOTTOM AND SIDES OF THE DITCH
n 0
D`\ 6" MIN.
moa a
Z G� 24" MIN.
L(I
0 oQ�o aoo0
2:1 SLOPES
2"-4" ROCK
Q�
G]QG� a
L = THE DISTANCE SUCH THAT POINTS
A AND B ARE OF EQUAL ELEVATION
;111115 oA L B
o4aa0
III III .,III„ 1111=
—I
NOTES
1. CONDITION OF USE
1.1. WERE CONCENTRATED RUNOFF FROM DISTURBED AREAS TO AND FROM PONDS OR TRAPS.
1.2. TO CONVEY RUNOFF INTERCEPTED FROM UNDISTURBED AREAS AROUND THE SITE TO A NON-EROSIVE DISCHARGE POINT.
2. MAINTENANCE STANDARDS
2.1. ANY SEDIMENT DEPOSITION OF MORE THAN 0.5 FEET SHALL BE REMOVED SO THAT THE CHANNEL IS RESTORED TO ITS ORIGINAL
DESIGN CAPACITY.
2.2. THE CHECK DAMS SHALL BE EXAMINED FOR SIGNS OF SCOURING AND EROSION OF THE BED AND BANKS. IF SCOURING AND EROSION
HAS OCCURRED, AFFECTED AREAS SHALL BE PROTECTED BY RIPRAP OR AN EROSION CONTROL BLANKET.
Y o STD. PLAN — 217.40
+ PUBLIC WORKS CHECK DAMS SPACING AND
DEPARTMENT CROSS SECTIONS
MARCH 2008
1. 6—FT" HIGH TEMPORARY CHAIN LINK FENCE SHALL BE
PLACED AT THE DR/PLINE OF THE TREE TO BE SAVED PRIOR
TO CONSTRUCTION. FENCE SHALL COMPLETELY ENCIRCLE THE
TREE(S). INSTALL FENCE POSTS USING PIER BLOCKS ONLY
AVOID DRIVING POSTS OR STAKES INTO MAJOR ROOTS.
2. FOR ROOTS OVER 1—IN DIA. THAT ARE DAMAGED DURING
CONSTRUCTION, MAKE A CLEAN, STRAIGHT CUT TO REMOVE
THE DAMAGED PORTION. ALL EXPOSED ROOTS SHALL BE
TEMPORARILY COVERED WITH DAMP BURLAP TO PREVENT
DRYING, AND SHALL BE COVERED WITH SOIL AS SOON AS
POSSIBLE.
J. WORK WITHIN PROTECTION FENCE SHALL BE DONE
MANUALLY. NO STOCKPILING OF MATERIALS, VEHICULAR
TRAFFIC, OR STORAGE OF EQUIPMENT OR MACHINERY SHALL
BE ALLOWED WI THIN THE LIMIT OF THE FENCING.
TREE PRO TEC TION DETAIL
R-383505
VERTICAL: NAVD 1988
HORIZONTAL: NAD 1983/1991
DATM
_ DR/PLINE I
I— �'I
DRAWINGS NOT APPROVED
FOR CONSTRUCTION UNLESS
STAMPED OR SIGNED APPROVED
BY THE REVIEWING AGENCY
CITY OE
RENTON
Planning/Building/Public Works Dept.
IN COMPLIANCE WITH CITY OF RENTON
STANDARDS
BY.
Date:'
BY:
Date: -746--/5
BY:
Date:
BY:
Date:
MAERTINS RANCH
T.E.S.C. NOTES AND DETAILS
01.20.2015
FIELDBOOK:
PAGE:
DRAWING NO:
C5
SHEET: 5 OF:20
v
�z
D
j C
71
cn
CIO2
Z
M
Z
C)
m�
M.,
C
'z
M
M
M
en
Cl
D
M
M
M
D
cn
CD
D'
cn
D
D
71
cn
CIO2
t:
�m
z
�S
Z
C)
m�
M.,
C
'z
M
M
M
en
Cl
D
I
t:
o00 (>
v, >
c
CD �
Z In
M
M
n
M
M
�o
D
cn<