A NON -WOVEN GEOTEXTILE SHOULD BE PLACED BETWEEN
THE SUBGRADE AND AGGREGATE BASE AS WELL AS SIDE
SLOPES OF THE OPEN GRADE BASE PERIMETER TO PREVEN'
CLOGGING OF INFILTRATION SURFACES. AASHTO M-288
(AASHTO 2010) PROVIDES GUIDANCE FOR SELECTION OF
GEOTEXTILES SPECIFICALLY FOR SEPARATION AND
DRAINAGE APPLICATIONS. THE GEOTEXTILE MUST PASS
WATER AT A GREATER RATE THAN THE SUBGRADE SOILS
(0.5 INCHES/HR) AND APPARENT OPENING SIZE OF 0.25 M)
MAX.
REFER TO THE REPORT PREPARED BY GEORESOURCES,
LLC FOR FURTHER GEOTECHNICAL AND PAVEMENT
RECOMMENDATIONS
_"GEOTECHNICAL CONSULTATION LETTER: POROUS
PAVEMENT FOR THE SLAVIC CHRISTIAN CENTER"
DATED: OCTOBER 22, 2013
CONTACT. BRAD P. BIGGERSTAFF, LEG &
DANA C. BIGGERSTAFF, P.E.
OFFICE: 253-896-1011
FAX: 253-896-2633
1. SUBGRADE SHALL BE SCARIFIED PRIOR TO
PLACEMENT OF NON -WOVEN GEOTEXTILE AND FINAL
GRADING. FINAL GRADING SHOULD BE COMPLETED
BY MACHINERY OPERATING ON A PRELIMINARY
SUBGRADE THAT IS AT LEAST 12 INCHES HIGHER
THAN FINAL GRADE OR STRUCTURES TO DISTRIBUTE
EQUIPMENT LOAD (e.g., STEEL PLATES OR
AGGREGATE BASE MATERIAL). FINAL EXCAVATION
THEN PROCEEDS AS MACHINERY IS PULLING BACK
AND TRAVELING ON PRELIMINARY GRADE AS FINAL
GRADE IS EXCAVATED.
2. TO PREVENT COMPACTION WHEN INSTALLING THE
AGGREGATE BASE, THE FOLLOWING STEPS
(BACK -DUMPING) SHOULD BE FOLLOWED:
(1) - THE AGGREGATE DISCHARGE BASE IS DUMPED
ONTO THE SUBGRADE FROM THE EDGE OF THE
INSTALLATION AND AGGREGATE IS THEN PUSHED
OUT ONTO THE SUBGRADE.
(2) - TRUCKS THEN DUMP SUBSEQUENT LOADS FROM
ON TOP OF THE AGGREGATE BASE AS THE
INSTALLATION PROGRESSES.
3. AVOID SUBGRADE PREPARATION DURING THE WET
SEASON (SOIL COMPACTION INCREASES
SIGNIFICANTLY IS SOIL IS WET).
4. IF MACHINERY (RECOMMENDED LGP EQUIPMENT)
MUST ACCESS THE FINAL GRADE, LIMIT THE ACCESS
TO A SPECIFIC TRAVEL WAY THAT CAN BE TILLED
BEFORE APPLICATION OF THE BASE AGGREGATE OR
PLACE HEAVY STEEL PLATES ON SUBGRADE AND
LIMIT TRAFFIC TO THE PROTECTIVE COVER.
5. NOTE: ALLOWING HEAVY MACHINERY ON PERMEABLE
PAVING SUBGRADES DURING WET OR SATURATED
CONDITIONS WILL RESULT IN DEEP COMPACTION
(OFTEN 3 FEET) AND CANNOT BE COMPENSATED FOR
BY SHALLOW TILLING OR RIPPING SOIL.
}
f
s
END ROAD
IMPROVEMENTS
STA, 2+53.16
TOP 203.0 -�
....- - TOE ZD1.0 -
27' RIGHT OF
WAY DEDICATION
TOP 209.2-�
TOE 203.5
/77///
TOP 209.2 O
TOE 203.3
EX. S SMH, -
STA 5+00,60, Q' R
4+80
TOP 204.6
TOE 201.3
y �
I.. �
--j
'AA1 TOP 202.5 f
TOE 195.0 r `
'UARDRAIL. SEE ROAD
SECTION DETAILS ON.
, SHEET C3
DATE:
APPROVED BY:
DATE:
-
2' TO 8' HIGH
-
DATE:
TRENCH
RETAINING WALL;
RIM
(DESIGNED BY
PIPE OUT SIZE
OTHERS)
c
TOP 196.4
(WxLxD)
TOE 193.4 .
6 LF, PVC @ 2%
7 LF, PVC @ 2%
.
1308,N 34 72 S. ST#334210,
f
7
4" IE 206.9 (N -IN)
5 x 48 x 2
CB #4
RIM 193.00 i
4" IE 206.8 (S -OUT)
4 " IE 192.00 (IN -N)
OUTLET DRAIN WALL PIPE .
(SEE 'FOOTING DRAINS' NOTE }.
6LF, PVC @2%
THIS SHEET)
•` �t
t .
209.5±
S
4" IE 206.4 (W -IN)
t4f
y'
z z
WEDGE
4" IE 206.4 (N -OUT)
CURB
BEGIN ROAD
IMPROVEMENTS
STA. 1+93.99
I
TYPE 1 (TYP) PER COR
STD, PLAN 200.00
110.3 N 36 7' A S7,
1419 YV`3,6T,1-[ST
CB #1 334--110---314
N88 °42'15"W 232.01 '
w }
p� �` �,} �__� 20.
Ui
r; N 88058'59" W 664.27'
NORTH 36TH STREET!
(FOREST A VENUE) p`
�f �. 20
I
Ln
�� LU
w m o `, ;
c i t a 19.
s \ 3 J
Qt I '\
i
X.-19
Ln
7
N 4 .
ti S 88 042'15" E 322.27' �- ~:t - �..-._ .:... _ �:__� w ._.. �. 18
I
io: - - - - ------
NORTHA
34TH STREET y n
FOOTING DRAINS (50' PUBLIC ROW) f
;
ALL FOOTING WALLS SHALL BE PROVIDED WITH A DRAIN AT THE
BASE OF THE FOOTING ELEVATION. DRAINS SHOULD CONSIST
OF 4" RIGID PVC PIPE SURROUNDED BY FREE DRAINING
GRANULAR MATERIAL, ESSENTIALLY FREE FROM VARIOUS TYPES
OF WOOD WASTE OR OTHER EXTRANEOUS OR OBJECTIONABLE
MATERIALS PER WSDOT STANDARD SPECIFICATION 9-03.12(2).
THE LEVEL OF THE PERFORATIONS IN THE PIPE SHOULD BE SET
AT OR SLIGHTLY BELOW THE BOTTOM OF THE FOOTING AND THE
DRAINS SHOULD BE CONSTRUCTED WITH SUFFICIENT GRADIENT
TO ALLOW GRAVITY DISCHARGE AWAY FROM THE BUILDING. SEE
SHEETS C3 AND C4 FOR DETAILS
Know what's below.
0111 before you dig.
NO.
REVISION
2+00
0
CUT 552 CY
r a� FILL 286 CY
1425N 361`HST NET 265 CY (CUT)
#334210-3143
VOLUMES ARE PRELIMINARY, A SHRINKISWELL FACTOR HAS NOT BEEN APPLIED.
5'x48' INFILTRATION
OSED 20' PERVIOUS TRENCH FOR FUTURE
ALT ROADWAY ROOFTOP (TYP) SEE
DETAIL ON SHEET C3
END ROAD
= [.I, 4 IMPROVEMENTS
1 - STA. 6+90,48, R 16.50'
23' ACCESS &
''- UTILITIES EASEMENT _
A NON -WOVEN GEOTEXTILE SHOULD BE PLACED
`.� BETWEEN THE SUBGRADE AND AGGREGATE
BASE AS WELL AS SIDE SLOPES OF THE OPEN
GRADE BASE PERIMETER TO PREVENT CLOGGING A
1L
'OF INFILTRATION SURFACES.
3+00
ROAD WAY PROFILE
SCALE: HORIZ 1 "=20' VERT 1 "=5'
SURVEYED: SCALE:
BEYLER CONSULT. 1 „=20' HORIZONTAL: NAD1983%1991
DESIGNED:
BML
DRAWN:
JAP ONE INCH DATU M
CHECKED: AT FULL SCALE
BML IF NOT ONE INCH
DATE A P P R APPROVED: SCALE ACCORDINGLY
LCB
20 10 0 20 40
SCALE: 1" = 20'
.YLA %'D .:' T ,--aIIEI N,'
L.
.3407 d 11,' O 141.% 'VE' %✓
3.x4:1 3159
215
210
Ivtm
200
195
190
189
3+80
"" CITY OE
RENTON
Planning/Building/Public Works Dept.
APPROPRIATE DESIGN, CONSTRUCTION AND MAINTENANCE
MEASURES WILL BE REQUIRED TO ENSURE THE
INFILTRATION RATE CAN BE EFFECTIVELY MAINTAINED
OVER TIME. IT SHOULD BE NOTED THAT SPECIAL CARE IS
REQUIRED DURING THE GRADING AND CONSTRUCTION
PERIODS TO AVOID FINE SEDIMENT CONTAMINATION OF
THE INFILTRATION SYSTEM. THIS MAY BE ACCOMPLISHED
BY USING AN ALTERNATIVE STORM WATER MANAGEMENT
LOCATION DURING GRADING AND CONSTRUCTION
ACTIVITIES. ALL CONTRACTORS WORKING ON THE SITE
(BUILDERS AND SUBCONTRACTORS) SHOULD BE ADVISED
TO AVOID "DIRTY" STORMWATER FLOWING TO THE SITE'S
STORMWATER SYSTEM DURING CONSTRUCTION AND
LANDSCAPING ACTIVITIES AT THE SITE. CONCRETE
TRUCKS SHOULD NOT BE WASHED OR CLEANED ON-SITE.
SUSPENDED SOLIDS COULD CLOG THE UNDERLYING SOIL
AND REDUCE THE INFILTRATION RATE FOR THE SYSTEM.
TO REDUCE POTENTIAL CLOGGING OF THE INFILTRATION
SYSTEMS, THE INFILTRATION SYSTEM SHOULD NOT BE
CONNECTED TO THE STORMWATER RUNOFF SYSTEM UNTIL
AFTER CONSTRUCTION IS COMPLETE AND THE SITE AREA
IS LANDSCAPED, PAVED OR OTHERWISE PROTECTED.
TEMPORARY SYSTEMS MAY BE UTILIZED THROUGH
CONSTRUCTION. PERIODIC SWEEPING OF THE PAVED
AREAS WILL HELP EXTEND THE LIFE OF THE INFILTRATION
SYSTEM.
SOURCE: CITY OF RENTON AMENDMENTS TO THE KING CO SWDM, REFERENCE 7-B
1. THESE PLANS ARE APPROVED FOR STANDARD ROAD
AND DRAINAGE IMPROVEMENTS ONLY. PLANS FOR
STRUCTURES SUCH AS BRIDGES, VAULTS, AND
RETAINING WALLS REQUIRE A SEPARATE REVIEW AND
APPROVAL BY THE CITY PRIOR TO CONSTRUCTION.
2. ROCKERIES ARE CONSIDERED TO BE A METHOD OF
BANK STABILIZATION AND EROSION CONTROL.
ROCKERIES SHALL NOT BE CONSTRUCTED TO SERVE
AS RETAINING WALLS. ALL ROCKERIES IN CITY ROAD
RIGHT-OF-WAY SHALL BE CONSTRUCTED IN
ACCORDANCE WITH CITY STANDARDS. ROCKERIES
OUTSIDE OF ROAD RIGHT-OF-WAY SHALL BE
CONSTRUCTED IN ACCORDANCE WITH THE
INTERNATIONAL BUILDING CODE.
R-383901 ac
BEYLER
CONSULTING
CONTACT
phone: 253-301-4157 OFFICE
fax: 253-336-3950 7602 Bridgeport Way W
beylerconsulting.com Lakewood, WA 98499
CITY OF RENTON
APPROVED BY:
DATE:
APPROVED BY:
DATE:
APPROVED BY:
DATE:
APPROVED BY.
DATE:
TRENCH
ZD
RIM
PIPE ZN
PIPE OUT SIZE
c
(WxLxD)
6 LF, PVC @ 2%
7 LF, PVC @ 2%
CB #1
209.0±
4" (STUB) IE 207.0 (W -IN)
4" IE 206.9 (N -IN)
5 x 48 x 2
7
4" IE 206.9 (E -OUT)
4" IE 206.8 (S -OUT)
6LF, PVC @2%
8LF, PVC @2%
CB #2
209.5±
4" (STUB) IE 206.5 (S -IN)
4" IE 206.4 (W -IN)
5 x 48 x 2
4" IE 206.4 (N -OUT)
4" IE 206.2 (E -OUT)
6 LF, PVC @ 2%
5 LF, PVC @ 2%
CB #3
209.0±
4" (STUB) IE 207.0 (N -IN)
4" IE 206.9 (N -IN)
5 x 48 x 2
4" IE 206.9 (S -OUT)
4" IE 206.8 (S -OUT)
R-383901 ac
BEYLER
CONSULTING
CONTACT
phone: 253-301-4157 OFFICE
fax: 253-336-3950 7602 Bridgeport Way W
beylerconsulting.com Lakewood, WA 98499
CITY OF RENTON
APPROVED BY:
DATE:
APPROVED BY:
DATE:
APPROVED BY:
DATE:
APPROVED BY.
DATE:
KENNYDALE VUE POINT SHORT PLAT
CONSTRUCTION PLANS
LUA14-000859 & U14-005633
GRADING, DRAINAGE, AND PAVING PLAN
DATE:
01 /27/201
FIELDfBOOK: NA
PAGE: NA
DRAWING NO:
C2
SHEET: 2 OF:13