Loading...
HomeMy WebLinkAboutzR-3760 SetH H I— /N V/ I a a CL GRAPHIC SCALE 20 0 10 20 SCALE IN FEET CONTACT LIST: APPLICANT/OWNER: MEDICI ARCHITECTS LITCHFIELD ENGINEERING 12840 81ST AVENUE NE Kirkland, Washington 98034 (425) 821-5038 FAX (425) 821-5739 11671 SE 1ST STREET POWER/NATURAL GAS: BELLEVUE, WA 98005 3 REVISED PER CITY COMMENTS CONTACT: EMILY BUCHWALTER CABLE TV: (425) 453-9298 EMILYOMEDICIARCHI TECTS.COM CIVIL ENGINEER: LITCHFIELD ENGINEERING m 12840 81ST AVENUE NE pw r\r� v3. KIRKLAND, WA 98034 DATE CONTACT: KEITH LITCHFIELD, PE .M.nm (425) 821-5038 KA.LITCHFIELD®FRON TIER. NET GEOTECHNICAL ENGINEER: GEOTECH CONSULTANTS, INC. KAL 13256 NE 20TH STREET, SUITE 16 Q a BELLEVUE, WA 98005 (425) 747-5618 SURVEYOR: SADLER/BARNARD ASSOC., INC. 0 -nz 717 WEST STEWART PUYALLUP, WA 98371 (253) 848-5170 DALEO®SADLERBARNARD.COM SITE DATA: KC PARCEL P. 2963900010,2963900011 TOTAL AREA: (t) 9,600 SF (0.22 AC) PROJECT SITE AREA (t) 7,858 SF (0.18 AC) IMPERVIOUS AREA (t) 7,940 SF (0.18 AC) FIRE DISTRICT: RENTON STATION 11 ZONING: RESIDENTIAL MULTI—FAMILY NEIGHBORHOOD: SOUTH RENTON FIRE DISTRICT: RENTON STATION 11 SCHOOL DISTRICT: RENTON UTILITY PURVEYORS: SEWER/WATER: CITY OF RENTON LITCHFIELD ENGINEERING 12840 81ST AVENUE NE Kirkland, Washington 98034 (425) 821-5038 FAX (425) 821-5739 425-430-6852 POWER/NATURAL GAS: PUGET SOUND ENERGY 3 REVISED PER CITY COMMENTS 1-888-321-7779 CABLE TV: COMCAST 1-877—COMCAST WASTE SERVICES: WASTE MANAGEMENT m 1-800-592-9995 I PORTION OF THE SE 1/4 OF THE SE 1/4 OF SECTION 18, TOWNSHIP 23 N, RANGE 5 E W.M. REM FOUND BRASS CAP W/TH PUNCH MARY /N C4SRNO (12106106) 017Y OF RENTON SURVEY CONTROL MON N0. 1898 N 176,367.836 E 1,299,159.285 - EX CB R/M 2697 L J OB R IM L J TOP SE FOWCE BOLT FH "0 RIM = 16.90 \ [ADDER ON SOUTH /E I7'AOS W = 20.65 If 12' AD5 E = 2251 IE 12"AD5 S = 20.94 CB RIM = 1657 /E I2'ADS E = 22.57 BLAKEY TOWNHOMES J MH RIM 27.60 /ADDER ON FULL OF WATER /E 12' CMP NW, SW, SE, NE = 1295 /E 12"P/PE N, E, W = 13+/(AS BU2TJ SSMH S 6t/ / St M = 6 Rz7ON,9 NORTH 11 C E -W, B" v'r S FO =21.16 o LCB R/M = 27.04 /E 11" CYANW = 13.39 /E 6'PVC S = 14.34 r R/M = 3.8 LADDER D27N BiRvL• N -S c FOUND TACH /N n LOT 3 LOT 4 RIM = 26.76 /E 12'A05 W = 23.45 IMPORTANT NOTE: THE PROJECT SHALL COMPLY TO THE CITY OF RENTON'S TRENCH RESTORATION AND OVERLAY REQUIRMENTS Call Working Days Before You Dig 1.800.424-5555I Itilities Underground Location Center QD,MT,ND,OR,WA) CNY OF NWON SURVEY LITCHFIELD ENGINEERING 12840 81ST AVENUE NE Kirkland, Washington 98034 (425) 821-5038 FAX (425) 821-5739 CONTROL MON. NO 1140 K' N. 17,9,048990 3 REVISED PER CITY COMMENTS E 1,299,198.110 v NO. REVISION C m I� ID pw r\r� v3. BY FOUND BRASS CAP W/TH PUNCH MARY /N C4SRNO (12106106) 017Y OF RENTON SURVEY CONTROL MON N0. 1898 N 176,367.836 E 1,299,159.285 - EX CB R/M 2697 L J OB R IM L J TOP SE FOWCE BOLT FH "0 RIM = 16.90 \ [ADDER ON SOUTH /E I7'AOS W = 20.65 If 12' AD5 E = 2251 IE 12"AD5 S = 20.94 CB RIM = 1657 /E I2'ADS E = 22.57 BLAKEY TOWNHOMES J MH RIM 27.60 /ADDER ON FULL OF WATER /E 12' CMP NW, SW, SE, NE = 1295 /E 12"P/PE N, E, W = 13+/(AS BU2TJ SSMH S 6t/ / St M = 6 Rz7ON,9 NORTH 11 C E -W, B" v'r S FO =21.16 o LCB R/M = 27.04 /E 11" CYANW = 13.39 /E 6'PVC S = 14.34 r R/M = 3.8 LADDER D27N BiRvL• N -S c FOUND TACH /N n LOT 3 LOT 4 RIM = 26.76 /E 12'A05 W = 23.45 IMPORTANT NOTE: THE PROJECT SHALL COMPLY TO THE CITY OF RENTON'S TRENCH RESTORATION AND OVERLAY REQUIRMENTS Call Working Days Before You Dig 1.800.424-5555I Itilities Underground Location Center QD,MT,ND,OR,WA) w ¢r � d 29476 �SstA�cti NA g'S STAMP NOT VALID UNLESS SIGNED AND DATED LITCHFIELD ENGINEERING 12840 81ST AVENUE NE Kirkland, Washington 98034 (425) 821-5038 FAX (425) 821-5739 41-14 K' 4 REVISED PER CITY COMMENTS 3 REVISED PER CITY COMMENTS 2 REVISED PER CITY COMMENTS 1 SUBMITTED TO CDENT NO. REVISION KAL -21-14 KAL I^^� KAL 41-14 K' C 6a A1-3-13 �= C m I� ID KAI. BY DATE APPR .M.nm ( KAL 16' 1 VICINITY MAP NOT TO SCALE LEGAL DESCRIPTION LOTS 2 AND 3, BLOCK 1, OF GUINN'S ADDITION TO RENTON. ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 17 OF PLATS, PAGE 76, IN KING COUNTY, WASHINGTON. VERTICAL DATUM FOUND 3" BRASS DISK STAMPED "KIING COUNTY SURVEY MONUMENT EN -61 1973" IN SIDEWALK ON THE WEST SIDE OF RAINIER AVE. SOUTH. LOCATED NORTH SIDE OF SOUTHERLY DRIVEWAY TO BUILDING AT 604 RAINIER AVENUE SOUTH ELEV=27.867 BASIS OF BEARING RECORD OF SURVEY, RECORDING NO. 2005060690003, RECORDS OF THE KING COUNTY AUDITOR. SHEET INDEX: 1. COVER SHEET 2. TESC & DEMOLITION 3. TESC DETAILS 4. GRADING, DRAINAGE & PAVING 5. DRAINAGE & PAVING DETAILS & NOTES 6. WATER & SEWER PLAN & PROFILE 7. WATER & SEWER DETAILS & NOTES UTILITY NOTES: LOCATION OF EXISTING UTILITIES SHOWN IS APPROXIMATE AND MAY NOT BE ACCURATE OR ALL INCLUSIVE. IT IS THE CONTRACTORS RESPONSIBLITY TO FIELD VERIFY LOCATION OF UTILITIES PRIOR TO PROCEEDING WITH CONSTRUCTION. OTHER UTILITIES(I.E. GAS, POWER, CABLE, (ETC.) REQUIRED FOR THE DEVELOPMENT OF THE PROJECT SHALL BE PLACED AND INSTALLED PER THE UTILITY PURVEYOR AND/OR CITY SPECIFICATION, WHATEVER MAY GOVERN. EASEMENTS OTHER THAN THOSE SHOWN MAY BE REQUIRED PENDING FINAL UTILITY DESIGN AND HORIZONTAL LOCATION BY OTHERS. I� o m o C 6a 3 �= C m I� ID I� o m o D II z TI H C m I I -- ( Q a c a 46 � 0 -nz 0 O FOUND 8M5S CAP WIIH PUNCH MARK IN CASWO (12/06/06) R=3 76001 I ITY OF RENTON APPROVED BY: y�DATE: loJ3 APPROVED BY: DATE: I } C APPROVEDI B � DATE: /- Z APPROVED BY: DATE: fol(�( � 1"=20' X0�0M°`""1061�'°°� CITY OF BLAKEY TOWNHOMES X12-3-13 RENTON 604 MORRIS AVENUE S Fac RENTON, WA 98055 a� Planning/Building/Public Works Dept. F MOI tlE MEM COVER SHEET 1 7 anr: aP 71111 �'D� 2-37i,00 I w ZZ U W O K o_ F ( CL CL a CONSTRUCTION SEQUENCE 1. SCHEDULE AND ATTEND A PRECONSTRUCTION MEETING WITH THE CITY OF RENTON. 2. INSTALL CONSTRUCTION ACCESS. 3. INSTALL SILT FENCE. 4. CONSTRUCT OFF-SITE STORM & INSTALL CB INSERTS. 5. ROUGH GRADE SITE. 6. INSTALL REMAINING STORM WATER SYSTEM & UTILITIES. 7. FINE GRADE SITE. B. PAVE AREAS AS INDICATED. 9. HYDROSEED REMAINING EXPOSED SOILS AND COVER AS APPROPRIATE 10. REMOVE TESC BMP'S UPON APPROVAL OF THE CITY OF RENTON. LEGEND: Call 2 Working Days Before You Dig 1.800-424.5555 Underground Locati (ID,MT,ND,OR,WA) 29476 STAMP NOT VALID UNLESS SIGNED AND DATED PORTION OF THE SE 1/4 OF THE SE 1/4 OF SECTION 18, TOWNSHIP 23 N, RANGE 5 E W.M. BLAKEY TOWNHOMES S 3rd L7t FILTER FABRIC FENCE 7 / ASPHALT REMOVAL EX CB AM 26.97 CONCRETEREMOVAL ------ EK CURB TO BE REMOVED REMOVE 1 '�i CONCRETE i 1 1 '7 1 71 L I INLEr PROTECTION nIIIIIIIIIIFiI�f�e�ltkl APPROX. LOCATION G) Call 2 Working Days Before You Dig 1.800-424.5555 Underground Locati (ID,MT,ND,OR,WA) 29476 STAMP NOT VALID UNLESS SIGNED AND DATED PORTION OF THE SE 1/4 OF THE SE 1/4 OF SECTION 18, TOWNSHIP 23 N, RANGE 5 E W.M. BLAKEY TOWNHOMES S 3rd L7t -1_14 7 / - CITY OF RENTON SURVEY EX CB AM 26.97 12-3-13 CONTROL MON N0. 1140 aFiva KAL REMOVE N 179,,048..990 CONCRETE F. 7799198.120 L I V Yom`„ � IIj FOUND RRASS CAP WTH PUNCH WX /N CAST/N6 (11/06/06) ///'''CR CITY OF RENTON SURITY / R/M = CONTROL MON N0. 1898 li{ /E 17i N 1769659)8 E: 1,299,759.185 L J 11 Ex TOP SE RANGE BOLT FN REMOVE EX CONIC SIDEWALK - AS NECESSARY FOR UTILITY IMPROVEMENTS. SAWCUT AS NECESSARY SAWCUT AND REMOVE PVMT�, AS NECESSARY FOR UDLRY IMPROVEMENTS lap3 WAT REMOVE IX CURB ASS NECESSARY TO INSTALL w/w' UTILITY IMPROVEMENTS. ED SAWCUT AS NECESSARY COORD W/ COR FORS -9113� REMOVAL OF EX WATER SERVICE IW 03 SOMH PIN = 26.90 L40PER ON SONH /E 12, ADS W = 20.65 /E 12"AOS E = 2252 IE 11"A05 S = 10.94 r CB RIM = 26.57 /E 12"ADS E = 22.57 Ex LITCHFIELD ENGINEERING 12840 81ST AVENUE NE Kirkland, Washington 98034 (425) 821-5038 FAX (425) 821-5739 Ex IX C� �R/M 1699 r 1L J R'm = L/.OV / LADDER ON 1 FULL OF WATER /E 11" CVP NW, SW, SE NE = 1295 /E 11' PIPE N, E, W = 1J+1 -(AS BU/C T) a SSMH lM = 27.68 IN R ON NORTH NE = 14.18 11 E -W, B' Rel' S FLOW = 21.15 _ N 89'47JO" E _ S 6th St J1587' FOUND TACK /N LEAD /N C/ASTINO (12106�06� - I y -\ I y% ycso l0 0 L 3 -CB R/M = 17.04 lE 11"CYA W=2J J9 0 o /E 6"PVC S = 24.34 N 89'4730" E - 119.95' Q `� p.. H d R SSMH 16, R/M 1738 (ADDER ON N N g Bi,INC N -S o p Min `O 'O m av,NE = 11.E \ o o `CB INLET RIM = 2675 /E 11"ADS W = 3 1 REVISED PER CITY COMMENTS 2 REVISED PER CITY COMMENTS 1 SUBMRfED To CLEW N0. REVISION KAL -1_14 7 / uy \ J KAI 12-3-13 7' 11.1 COMPANYIII GAS aFiva KAL REMOVE I DATE I CONCRETE tnsrm KAL �. V+ nIIIIIIIIIIFiI�f�e�ltkl G) D C M D I T "1'1 71 1 . 1 "1 1 7.131 1 `CB INLET RIM = 2675 /E 11"ADS W = 3 1 REVISED PER CITY COMMENTS 2 REVISED PER CITY COMMENTS 1 SUBMRfED To CLEW N0. REVISION KAL -1_14 Z uy \ J KAI 12-3-13 KAL aFiva KAL BY I DATE I APPR tnsrm KAL /6' I STABILIZED CONSTRUCTION I ENTRANCE PER DETAIL SHEET 3 31 I I South 7th Street FOUND BRASS CAP WAN PUNCH U,f& /N CASRNO (12/06/06) EROSION CONTROL NOTES 1. These notes shall appear far all projects - site improvements, surface water utility, wastewater utility; waterutility, and transportation plans: 2. Before any construction or development activity occurs, a pre -construction meeting must be held with the City of Renton, public wools design engineer. 3. The Boundanes of the Gearing limits and areas of vegetation preservation as prescribed on the plan(s) shall be clearly flagged by survey tape or fencing in the field prior to constriction in accordance with Appendix D of the Surface Water Design Manual and observed during construction. During the construction period, no disturbance beyond the clearing limits shag be permitted. The clearing !units shall be maintained by the applicant/FSC supervisor for the duration of construction. 4. Stabilized construction entrances shall be installed at the beginning of construction and maintained for the duration of the project. Additional measures, such as .constructed wheel wash systems or wash pads, may be required to enure that all paved areas arekept clean and track out to mad right of way does not occur for the duration of the project. S. All required sedimentation/erosion control fadlities must be casbucbed and in operation prior to land clearing and/or construction to prevent transportation of sediment to surface water, drainage systems and adjacent propene. All erosion and sediment facilities shall be maintained In a satisfactory condition until such time that clearing and/or construction As complebe and potential for on-site erosion has passed. The implementation, maintenance, replacement and additions to erosion/sedimentabon control systems shall be the responsibility of the permitee. 6. The erosion and sedimentation control systems depicted on this drawing are intended to be minimum. requirements to meet anticipated site condltiom As constructionprogresses and unexpected or seasonal mMitions diclate, the permitee shall anticipate that more erosion and sedimentation control facilities will be necessary to ensure complete siltation control on the proposed site. During the course of construcion, it shall be the obligabon and responsibility of the permitee to address any new conditions that may be created by the activities and to provide additional facilities, over and above minimum requirements, as may be needed, to protect adjacent properties and water quality of the receiving drainage system. 7. Approval of this plan is for erosion/sedimentation control only. It does not ronsubft an approval of storm drainage design, size nor location or pipes, resbictors, channels, or retention facilities. 8. Any areas of exposed soils, including roadway embankmeds, that will not be disturbed for two days during the wet season (October 14 trough March 30t) a seven days during the dry season (April 1a tough Septanber 30) shag be immediately stabilized with the approved ESC cover methods (e.g., seeding, mulching, plastic covering, etc.). 9. Wet season seasonal erosion and sediment canard requirements apply to all construction sites dearing between October 1 and March 30 inclusive, unless otherwise approved by the City through an adjustment process. 10. Cover measures will be applied in conformance with Appendix D of the Surface Water Design Manual. 11. Any area needing ESC measure, not requiring immediate attention, shall be addressed within seven (7) days. 12. The FSC fadildes on inactive sits shall be inspected and maintained a minimum or once a month or within 24 hours following a storm even. 13. At no time shall more than one (1) foot or sediment be allowed to accumulate within a catch basin. All catch basins and conveyance lines shall be cleaned prior to paving. The cleaning operation shall not flush sediment -laden water into the downstream system. 14. During the time period of October 1` through March 30°, all project distributed soil areas grow, that are to be left un -worked for more than 12 hours, shall be covered by mulch, sodding or plastic covering. 15. Any permanent rete bon/detention fadlity used as a temporary settling basin shall be modified with the necessary eroslon control measures; and shall provide adequate storage opacity. If the permanent facility is to fundmin ultimately, as an ird0bation system, the temporary facility must be rough graded so that the bottom and sides are at least three feet above the final grade of the permanent facility. 16. prior to the beginning of the wet season (Oct 1), all disturbed areas shag be reviewed to identify which ones on be seeded In preparation for the wince rains. Disturbed areas shall be seeded within one week of the beginn" of the wet season. A sketch map of those areas to be seeded and those areas to remain uncovered shall be submitted N the City of Renton for review. aaCITY OF .RENTON �� DATUM a rvu swc Planning/Building/Public Works Dept. F Itlf dE MI 4DVE /bGIOIMYY 3 � I Z uy \ J CJ D C r --1 0-1 O o H �$ Z Naz � S z V+ m G) D C � I uy \ J CJ D DATE: %I r --1 0-1 O o H �$ Z Naz � S z V+ m G) m; em C M D � I uy \ J CJ D DATE: %I r --1 0-1 O o H O Z Naz � S ' V+ m i i i R-316002 � CITY OF RENTON GRAPHIC SCALE APPROVED BY: 20 0 10 20 APPROVED BY:( SCALE IN FEET APPROVED v APPROVED BY: BLAKEY TOWNHOMES 604 MORRIS AVENUE S RENTON, WA 98055 TESC & DEMOLITION Dae 12-3-13 I SATE: towf/rf DATE: %I $ >A DATE: (a% uZ�1 DATE: c )� A G) Dae 12-3-13 H F N N 1 a a a 1 1 11. J w 17 LITCHFIELD ENGINEERING Call 2 Working Days Before You Dig 2Sa7B 12840 81ST AVENUE NE 4 REVISED PER CRY COMMENTS - - 119]@ NTS 1-800-424-5555 �sslAc� 1k Kirkland, Washington 98034 3 REVSW PER CRY COMMENTS LUL 7-zT-T KAI KAL Itllitiea Underground Location Center (425) 821-5038 FAX (425) 821-5739 2 REVISED PER CRY COMMENTS KAL 4-1-14 KAL DRI KAL (ID,MT,ND,OR,WA) STAMP NOT VALID 1 SUBMffRLD TO CLIENT KAL 2-3-13 KAL � UNLESS SIGNED AND DATED KAL xm GIE�iLnl N0. REVISION BY DATE APPR .. Ea"� 6 MLIiSMRL,ERFABP1C61WLBE8gAFD q0 AT PoSi8 U5=5fAPLES. NiIE gNGS,OR % EGM.LLENFTO AT IACII F/.BFDCro Po518 EWWAL2W' BY 4Ga.WIr-DA STRENGLII FABRIC INN 33 nLTERFAMIO P I / M1l r BNAK MINWUMa%YTRENGH IJ 8AF-E1TRENCNWITH PST SPNLGNAY PE WCNEISFO � N4TIYE.Sdt T091FN1REB.YlUXG4U5F0 "Ce"S' ERROR OR STEELPENCE PO51G. ERROR OR WENN-ENT NOTES 1. CONDIIIONOFUSE 1.1. SRT FENCE MAY BE USED DOWNSIDPE OF ALL DISTURBED AREAS. 12 SRT FENCE IS NOT INTENDED TO TREAT CONCENTRATED FLOWS, NOR 15 INTENDED TO TREAT SUBSTANTIAL AMOUNTS OF OVERLAND FLOW. ANY CGRCENRRAIIED FLOW MOST BE CONVEYED THROUGH THE DRAINAGE SYSTEM TO A SEDIMENT TRAP OR FORD. 2 UE5IGNAND NSTALIATN]N SPEI]FICATIONS 2.1. THE GEOTEDlTILE USED MOST MET THE STANDARD LISTED BELLOW. A COPY OF THE MANUFACTURER'S FABRIC SPECIFICATIONS MOST BE AVAILABLE ON SITE. 22 STANDARTR D STRENGTH! FABRIC REWIRES WIRE MOUND TO INCREASE THE STRENGTH OF THE FENCE. WIRE BACKING OR CLOSER POST SPACING MAY BE REWIRED FOR EXTRA STRENGTH FABRIC IF FIELD PERFORMANCE WARRANTS A STRONGER FENCE. I WHERE THE FENCE IS INSTAJ ED, THE SLOPE SHALL NOT BE STEEPER THAN 2HAV.. 2.4. IF ATYPICAL SILT FENCE IS USED, THE STANDARD "4 TRENCH MAY NOT BE REDUCED AS LONG AS. THE BOTTOM B INCHES OF THE SILT FENCE M WELL BURIED AND SECURE IN ATRENCH THAT STABILIZES THE FENCE AND DOES NOT ALLOW WATER TO BYPASS OR UNDERMINE THE SILT FETE l MAIMENANCE STANDARDS LL 11. ANY DAMAGE SHABE REPAIR IMMEDIATELY. 32 IF CONCENLRATEp ROES ARE EVIDENT UPHILL OD THE FENCE. THEY MUST BE INTERCEPTED AND CONVEYED TO A SEDIMENT TRAP OR POND. 13. IT IS IMPORTANT TO CHECK ING A THE UPHILL SIDE OF THE FENCE FOR OF THE FENCE CLOGGND ACTING AS A BARRIER TO FLOW AND THEN CAUSING CHANNELIZATGi OF ROWS PARALLEL TO THE FENCE IF THIS OCCURS, REPLACE THE FENCE OR REMOVED THE TRAP SEDMENT. 3A. SEDIMENT MOST BE REMOVED WHEN SEDIMENT IS 6 INCHES HIGH. 3.i IF THE FILTER FABRIC (GEOTEXI'LLE) HAS DETERIORATED DUE TO ULTRAVIOLET BREAKDOWN: IT SHALL BE REPLACED. 8� � � PUBLIC WORKS SILT FENCE STD, PLAN- 214.00 +7� DEPARTMENT >\c :MARCH 2008 Am IpSTMOIhL LLNSIMSREI¢OYISWIHTevITUIM DPoVEWAn 51N1L0E Pw4FD TO rHEFIXiE salmverts� aaa ipRoixiaiaeNa WAIBHOf11N11Y AS1MD61 6@SK^IMMLMAH w•TDRx1EsrNNwrlwsnAORm1 __ 18meSMR. iOq EtIMS1RMOliABPoC rtwRFwNNExoEnTrArTHE flnl8i L9lNM5lAN01PD S1RRIGMFA9ilC GM•twvRRlaxwnax uTM xMAX uTMwmrTMsmAnu wsnAOAm nxA•x. INSTALLOPoVEWAYCIILVERTIP� Is A RwoSI of Drzcr wiESENr, AS PER CITT ROAD STANDARb$ 4'80WPoLY^3ALLG - GEOTEKI6E iT NYITIpCgff$$ pR�.M�FL,y yApTM pF NOTES. � 1NGRFSyEGRES$aRFA 1. CONDITION OF USE I.I. CONSTRUCTION ENTRANCE SHALL RE STABILQEOWHEREVERTRAFFlC WILL BE LEAVING ACONSTRUCTION SITE AND TRAVELINGON PAVED ROADS OR OTHER PAVED AREAS WITHIN 1.00D FEET OF THE SUE. DPoVEWAn 51N1L0E Pw4FD TO rHEFIXiE ��µLOR°w GJ" / of Row vlwR ro InSTALunox of rxE coNsrRucnaNEmwncerowvuo OANAGINGCFIxE PoMWpY // }pM15(U.S.STANDARDSIEVEA2E1 rtwRFwNNExoEnTrArTHE a=asenrv. ENnuN¢�camANEosomAr RVIbFFORNN50FFTHEPIp S GMB TENSILE SrREGN GTH (ASTM Df/$II 21p PN MN. GRAS TENSILE 'ELONGATION (AiTMFIS 12. DESIGN AND INSTALLATION SPECIFICATIONS 2:1. HOG FUEL (WOOD BASED MULCH)MAY BE SUBSTITUTED iEI_ 3D16 MAX MULIEN BUR5T5TRENGM (q$1AA D3]6SBM ICO PSIMN. A05(ASTM M]511 }pM15(U.S.STANDARDSIEVEA2E1 2.2. FENCING SHALL BEINSU 2'.3, WHENEVERPOSSIBLE. TI INCREASE THEEFFECTI4 3. MAINTENANCE STANDARDS 3.1. QUARRY SPALLS SHALL 3.2. IFTHE ENTRANCEiSNOT I 3:3. I 3.4. 3:5. NO USED MAY SUBSTANTIALLY LIS arnr.Taeffr•1 l aaar,TNI:I DUCTED. TIRE SEDIMENT WOULD THEN BE WASHED INTO THE SUMP WHERE IT CAN BE CONTROLLED AND :LY. ARE LOOSENED FROM THE PAD AND END UP ON THE ROADWAY SHALL BE REMOVED IMMEDIATELY. I OR EJ(ITING THE STIES AT POINTS OTHER THAN THE CONSTRUCTION ENTRANCE(SJ, FENCI NG SHALL BE M. PUBLIC WORKS STABILIZED• ]?I.AA -215.10 DEPARTMENT CONSTRUCTION ENTRANCE MARCH 2008 DRAINM:EGNAIE- :TRIM S� GRATEt'RAME- E +p SEOWENTPN60E(NRI5 .. OVERFIllW BYPASS BELOW INLET GRPTEpP4GE EaT£AED 6 WATE0. d 0 d e sfcnory vlEw DfWNAGE GRATE -REDTANGULAR GRATE SNOWN' REIRIEVP1SV51EM [IYP.) i BELow WIt'T'caaiE DEVICE ovERFLowsYPAssTnP.1 ISOMETRIC VIEW NOTES 1. Size Ole Below Inlet Emile Devke(BIGO)for the sbmn xatereWCRve itwlllMMce. 2. The BIGD 4hali Neve abultt-1n tligMMwteOef system (weMow bypass). 3. The reMevel system muslabW rempVel NOIe GIGO xi8lwisptlling the cdbrted meleNei. 4. Pafmm mainknlmLe in acmltlance wHm Steey]eltl Spetllkstlon 8-013(15). PUBLIC WORKS CATCH BASIN FILTER STD. PI.AtI - 218.30 DEPARTMENT MARCH 2008 " CITY OF RENTORAli DATUM Planning/Building/Public Works Dept. CITY OF RENTOR APPROVED BY: DATE: APPROVED BY: DATE: APPROVED DATE: APPROVED BY: DATE: BLAKEY TOWNHOMES X12-3-13 604 MORRIS AVENUES RENTOR, WA 98055 IIIIIIIIIIIII'm R-316003 TESC DETAILS "`B 3 �f I � � o Z o \6 'az m I D uy � > v 7 i In o 'j I u> E/ Z C � �CCi I � m � D H a �CCi H a a a H 4) E z L 3 W 0 O o_ 4) Y N Fn LEGEND: o�SEWER CLEANOUT PORTION OF THE SE 1/4 OF THE SE 1/4 OF SECTION 18, TOWNSHIP 23 N. RANGE 5 E W.M. BLAKEY TOWNHOMES TOP SE FLANGE PATCH CONCR&TgA-,, AT UTILITY TRENCH PER COR FD05.1 ASPHALT CONCRETE VMTPAVEMENT IX I REPAIR. MATCH PVMi ECTION\DTII\ II RESTORATION W/ IN THE ROW SHALL MEET THE COR TRENCH RESTORATION STANDARDS MON i e CEMENT CONCRETE TRAFFIC CURB PER WSDOT STD PLAN F-10.12-00 a MATCH HEIGHT OF EXISTING CURB IE 24.15 55 LF 8- SO RIM = 26.90 MOVER ON 50117H lE 12'AOS W = 20.65 /E 12'AOS f = 22.52 lE !2"AOS 5 20.94 CB RIM = 2657 lE 12'AOS f = 22.57 PERFORATED DOWNSPOUT CONNECTION SEE DETAIL C.2.11A Ex �C9 - - - RIM 26.99 r J N AD = 2Z60 L /ADDER LA RCL *OF COURIER lE 12' CNP NW, SW, SE, NE = 7295 /E 12"PIPE N, E W = 0+/ -(AS 8/LTJ N 89'4710' E _ SyyHJ15.87' M = 27.68 S 6th St DER ON NORM 12 E -W, 8" PYO S RO = 21.16 L 08 RIM = 27.04 1E 12' CAII = 21J9 1E 6' PIC S = 24.34 N 81 E - 119.95' RIM 27.1 17 3rd St 10T 1 IE 24.3 (8- E&SW) IN&OUT _ EX CB- Kl q• H005E RIM 27.0 C1TY OF PENTON SURREY RL/A 2697 \ 1 4 EX CONTROL MON N0. 1140 I� n ?3z C. 178,048.990 L- I E 1,299,198120 z V APPROVED BY DATE: 9 If 9 BLAKEY TOWNHOMES ' 604 MORRIS AVENUE S w I m .o D \ FOUNP 8RASS CAP WITH PUNCH MARK /N CASTING (12/06/06) j CB C17Y OF PENTON SURVEY CONTROL MON N0. 1898 if 17 MP NE = 24.18 N 176,J6782 f 1,299,159.285 I7[ L J I j TOP SE FLANGE PATCH CONCR&TgA-,, AT UTILITY TRENCH PER COR FD05.1 ASPHALT CONCRETE VMTPAVEMENT IX I REPAIR. MATCH PVMi ECTION\DTII\ II RESTORATION W/ IN THE ROW SHALL MEET THE COR TRENCH RESTORATION STANDARDS MON i e CEMENT CONCRETE TRAFFIC CURB PER WSDOT STD PLAN F-10.12-00 a MATCH HEIGHT OF EXISTING CURB IE 24.15 55 LF 8- SO RIM = 26.90 MOVER ON 50117H lE 12'AOS W = 20.65 /E 12'AOS f = 22.52 lE !2"AOS 5 20.94 CB RIM = 2657 lE 12'AOS f = 22.57 PERFORATED DOWNSPOUT CONNECTION SEE DETAIL C.2.11A Ex �C9 - - - RIM 26.99 r J N AD = 2Z60 L /ADDER LA RCL *OF COURIER lE 12' CNP NW, SW, SE, NE = 7295 /E 12"PIPE N, E W = 0+/ -(AS 8/LTJ N 89'4710' E _ SyyHJ15.87' M = 27.68 S 6th St DER ON NORM 12 E -W, 8" PYO S RO = 21.16 L 08 RIM = 27.04 1E 12' CAII = 21J9 1E 6' PIC S = 24.34 N 81 E - 119.95' RIM 27.1 CITY OF RENTON 10T 1 IE 24.3 (8- E&SW) IN&OUT SM CB TYPE i Kl q• H005E RIM 27.0 IE 24.7 (8- E&W) IN&OUT 1 4 EX 275 I� n ?3z z $ APPROVED BY DATE: 9 If 9 BLAKEY TOWNHOMES ' 604 MORRIS AVENUE S '� ili�9 :,i��:� - ••Iii; , HIM = 26. 6 1E "AX W= LITCHFIELD ENGINEERING x d Call Working Days Before You Dig 29478 12840 81ST AVENUE NE 4 REVISED PER CRY COMMENTS 1-800-424-5555 s701f AA f3l A Kirkland, Washington 98034 3 REVISED PER CITY COMMENTS Itilities Underground Location Center 9' (425) 821-5038 FAX (425) 821-5739 2 REVISED PER CITY COMMENTS (ID,111T,ND-OR,WA) STAMP NOT VALID 1 SUBMITTED TO CLIENT UNLESS SIGNED AND DATED N0. REVISION 113 LF 8- SO 0 1% MIN-/ (DS CONNECTION) FOOTING DRAIN CONNECTION PMtA M TVPF 0 - da' IE 24.3 (4' NE) IN IE 23.6 (8 (' N,E) IN IE 23.6 12- SW) OUT DoT 4 (8- W) OUT FOUND TACK 1N LEAD /N GISTINO (12/Ds/os� M v�lo�a I ' o N h 16' NNS h $oo 3 �I �I gI GRADEPP-CEMENT CONCRETE PAVEMENT MATCH AT EX ALLEYar 1 1 1 REFER ZalF ... WmIiml L \ 1 1WGS 1. ..... STAMP/SCORING PATTERN lie: e::l.: I&.;�`,.. • ...........I EL n Iy-■ -FLOWCONTROL OF PERMEABLE PAVEMENT 1 PARKING AREAS ONLY ¢ [ RIM 27.4 IE 243 1�iwsucj 1.0% - CONNECT SO TO IX CB-c4Q6 DWLJ- IE 23.45 (1F CaUDInw BF SDG6 13 Awai 6OMAACTt>2 Shh"L N I _ Sou_th 7th Street FOUND BRASS CAP WITH PUNCH IhWR' IN CASTING (12/06/06) 1,o5T"`'` AND' IMPORTANT NOTE: "'rype i c8 PIER Caa pmemwI THE PROJECT SHALL COMPLY TO THE CITY OF RENTON'S TRENCH RESTORATION AND OVERLAY REQUIRMENTS 1-=20' KAL 4-1-14 KAL awxe KAL ac ea KAL2-3-13 KAL TICAL P O qE MQ BY DATE APPR I A`P-•e�!", DATUM MINERAL SITE NOTES: TOTAL PROPERTY AREA: 9,598 SF AREA OF WORK: 9,598 SF APPROXIMATE EARTHWORK QUANTITIES: CUT VOLUME: 350 CY (INCLUDES STRIPPING) FILL VOLUME: 120 CY TYPE AND LOCATION OF FILL ORIGIN TO BE DETERMINED BY CONTRACTOR FROM AN APPROVED SOURCE. DESTINATION OF SOIL REMOVED FROM THE SITE SHALL BE DETERMINED BY THE CONTRACTOR AND SHALL BE AN APPROVED SITE. THE QUANTITIES SHOWN ARE PRELIMINARY ESTIMATES ONLY AND INTENDED FOR MUNICIPAL PERMITTING AND REVIEW FEES. THE CONTRACTOR SHALL IGNORE THESE QUANTITIES, THEY ARE EXCLUDED FROM THE BID DOCUMENT INFORMATION. THESE VOLUMES SHALL NOT BE USED BY THE CONTRACTOR AS A BASIS FOR ANY CONTRACTUAL INFORMATION. THE CONTRACTOR SHALL PREPARE THEIR OWN EARTHWORK QUANTITIES BASED ON THE INFORMATION PROVIDED IN THE CONTRACT DOCUMENTS, INCLUDING BUT NOT LIMITED TO DRAWINGS, SPECIFICATIONS, AND THE GEOTECHNICAL REPORT. SD CAPACITY CALCULATION: 100 -YR PEAK FLOW RATE: 0.12 CFS 6 -INCH PVC PIPE 01.0% CAPACITY = 0.65CFS PERMEABLE PAVEMENT NOTE: PERMEABLE PAVEMENT - 4' POROUS ASPHALTIC CONCRETE OVER 6' MIN THICKNESS FREE -DRAINING SAND OR GRAVEL BASE FREE -DRAINING BASE SHALL HAVE LESS THAN 5% FINES (MATERIAL PASSING /200 SIEVE BASED ON THE FRACTION PASSING THE 14 SIEVE) POROUS CONCRETE PAVEMENT SHALL BE PERMEABLE ENOUGH TO ABSORB WATER AT A MINIMUM RATE OF 10 INCHES PER HOUR IMMEDIATELY AFTER THE SURFACE HAS BEEN WETTED CONTINUOUSLY FOR AT LEAST 10 MINUTES COMPLIANCE WITH THIS MINIMUM SHALL BE CHECKED PRIOR TO CONSTRUCTION APPROVAL OF THE PAVEMENT. 5D PIPG PS& t.oA. 15-705 656B cop-2.011DA&AMM &I -r* x4sAjbm-2OM9 ezrnmN) rea )-Inas /til lgz.eo. GRAPHIC SCALE 20 0 10 20 SCALE IN FEET CITY OF RENTON Planning/Building/Public Works Dept. R-316004 I CITY OF RENTON I o 3 i ,a s APPROVED BY DATE: 1 N� m I� n ?3z I CITY OF RENTON I o 1 �•,O e ' Paz s APPROVED BY DATE: 1 N� z ?3z z $ APPROVED BY DATE: 9 If 9 BLAKEY TOWNHOMES ' 604 MORRIS AVENUE S m .o D I CITY OF RENTON I I pn 1 �•,O e ' Paz 0 APPROVED BY DATE: 1 N� APPROVED BY DATE: e 1 GRADING, DRAINAGE & PAVING A ¢"7 CT)-. 12-�76Qo`I` CITY OF RENTON I APPROVED BY: DATE: Z I O APPROVED BY DATE: v APPROVED BY DATE: e 1 APPROVED BY DATE: 9 If 9 BLAKEY TOWNHOMES X72-3-13 604 MORRIS AVENUE S RENTON, WA 98055 .o GRADING, DRAINAGE & PAVING A ¢"7 CT)-. 12-�76Qo`I` Surface Water Drainage Notes and Specifications 1. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE -CONSTRUCTION MEETING MUST BE HELD WITH THE CITY OF RENON PLAN REVIEWER. 2. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION PREPARED BY NWSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA), AS AMENDED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT, 3. THE SURFACE WATER DRAINAGE SYSTEM SHALL BE CONSTRUCTED ACCORDING TO THE APPROVED PLANS, WHICH ARE ON FILE IN THE PUBLIC WORKS a DEPARTMENT. ANY DEVIATION FROM THE APPROVED PIANS WILL REQUIRE WRITTEN APPROVAL FROM THE CITY OF RENTON PUBUC WORKS DEPARTMENT, d SURFACE WATER UTILITY SECTION. d 4. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 5. DATUM SWU1 BE NAVD 88 UNLESS OTHERWISE APPROVED 81' THE CITY OF RENTON PUBUC WORKS DEPARTMENT. REFERENCE BENCHMARK AND ELEVATIONS ARE NOTED ON THE PIANS. 6. ALL SEDIMENTATION/EROSION FACILITIES MUST BE IN OPERATION PRIOR TO CLEARING AND BUILDING CONSTRUCTION, AND THEY MUST BE SATISFACTORILY MAINTAINED UNTIL CONSTRUCTION IS COMPLETED AND THE POTENTIAL FOR ON-SITE EROSION HAS PASSED. 7. ALL RETB!RION/DETENTION FACILITES MUST BE INSTALLED AND IN OPERATION PRIOR TO OR IN CONJUNCTION WITH ALL CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITY SECTION. B. GRASS SEED MAY BE APPLIED BY HYDROSEEDING. THE GRASS SEED MIXTURE, OTHER THAN CITY OF RENTON APPROVED STANDARD MIXES, SHALL BE SUBMITTED BY A LANDSCAPE ARCHITECT AND APPROVED BY THE PUBLIC WORKS DEPARTMENT, SURFACE WATER UTUTY SECTION. 9. ALL PIPE AND APPURTENANCES SHALL BE LAD ON A PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH SECTION 7-08.3(1) OF THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION FOR ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIA., AS WELL AS PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIA., TO UNIFORM GRADE SO THAT THE ENTRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. ALL PIPE BEDDING SHALL BE APWA CLASS 'C-, WITH THE EXCEPTION OF PVC PIPE AL TRENCH BACKFILL SHALL BE COMPACTED TO MINIMUM 95 % FOR PAVEMENT AND STRUCTURAL FILL AND 90 % OTHERWISE PER ASTM D-1557-70. PEA GRAVEL BEDDING SHALL BE 6 INCHES OVER AND UNDER PVC PIPE. 10. GALVANIZED STEEL PIPE AND ALUMINIZED STEEL PIPE FOR ALL DRAINAGE FACILITIES SHALL HAVE ASPHALT TREATMENT #1 OR BETTER INSIDE AND OUTSIDE. 11. STRUCTURES SIWl NOT BE PERMITTED WITHIN 10 FEET OF THE SPRING LINE OF ANY STORM DRAINAGE PIPE, OR 15 FEET FROM THE TOP OF ANY CHANNEL BANK. 12. AL CATCH BASIN GRATES SHALL BE DEPRESSED 0.10 FEET BELOW PAVEMENT LEVEL. 13. OPEN CUT ROAD CROSSINGS THROUGH EXISTING PUBLIC RIGHT OF WAY WILL NOT BE ALLOWED UNLESS SPECIFICALLY APPROVED BY CITY OF RENTON PLANNING/BUILDING/PUBLIC WORKS ADMINISTRATOR. 14. ROCK FOR EROSION PROTECTION OF ROADSIDE DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A DEPTH OF ONE (1) FOOT AND MUST MEET THE FOLLOWING SPECIFICATIONS: 4 - 8 INCH ROCK / 40- 70 % PASSING; 2 - 4 INCH ROCK / 30 - 40 % PASSING; AND LESS THAN 2 INCH ROCK / 10 - 20 % PASSING. 15. ALL BUILDING DOWNSPOUTS AND FOOTING DRAINS SW41 BE CONNECTED TO THE STORM DRAINAGE SYSTEM, UNLESS APPROVED BY THE CITY PLAN REVIEWER OR SURFACE WATER UTILITY SECTION. AN ACCURATELY DIMENSIONED, CERTIFIED AS -BUILT DRAWING OF THIS DRAINAGE SYSTEM WILL BE SUBMITTED TO THE CITY UPON COMPLETION. 16. ISSUANCE OF THE BUILDING OR CONSTRUCTION PERMITS BY THE CITY OF RENTON DOES NOT RELIEVE THE OWNER OF THE CONTINUING LEGA OBLIGATION AND/OR LIABILITY CONNECTED WITH STORM SURFACE WATER DISPOSITION. FURTHER, THE CITY OF RENON DOES NOT ACCEPT ANY OBUGATION FOR THE PROPER FUNCTIONING AND MAINTENANCE OF THE SYSTEM PROVIDED DURING CONSTRUCTION. 17. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE SAFEGUARD, SAFETY DEVICES, PROTECTIVE EQUIPMENT, FLAGGERS, AND ANY OTHER NEEDED ACTIONS TO PROTECT THE LIFE, HEATH, AND SAFETY OF THE PUBLIC, AND TO PROTECT PROPERTY IN CONNECTION WITH THE PERFORMANCE OF WORK COVERED BY THE CONTRACT. ANY WORK WITHIN THE TRAVELED RIGHT OF WAY THAT MAY INTERRUPT NORMA. TRAFFIC FLOW SHAT REQUIRE A TRAFFIC CONTROL PUN APPROVE BY THE PUBLIC WORKS DEPARTMENT, TRANSPORTATION SYSTEMS DIVISION. AL SECTIONS OF THE WSDOT STANDARD SPECIFICATIONS 1-07-23 TRAFFIC CONTROL SHALL APPLY. 18. SPECIAL DRAINAGE MEASURES WILL BE REQUIRED IF THE PROJECT LOCATION IS WITHIN THE AQUIFER PROTECTION AREA (APA). 19. THE FOOTING DRAINAGE SYSTEM AND THE ROOF DOWNSPOUT SYSTEM SHALL NOT BE INTERCONNECTED UNLESS SUCH CONNECTION IS AT LEAST 1 FOOT BELOW THE FOOTING DRAINAGE SYSTEM AND DOWNSLOPE OF THE BUILDING FOUNDATION. ROUTE FTG DRAINS THROUGH A CB PRIOR TO CONNECTION. 20. PROVIDE AND MAINTAIN TEMPORARY SEDIMENTATION COLLECTION FACILITIES TO ENSURE SEDIMENT OR OTHER HAZARDOUS MATERIAL DO NOT ENTER THE STORM DRAINAGE SYSTEM. 21. PRIOR TO FINAL INSPECTION AND ACCEPTANCE OF STORM DRAINAGE WORK, PIPES AND STORM DRAIN STRUCTURES SHALL BE CLEANED AND FLUSHED. ANY OBSTRUCTIONS TO FLOW WITHIN THE STORM DRAIN SYSTEM, (SUCH AS RUBBLE, MORTAR AND WEDGED DEBRIS), SHAT BE REMOVED AT THE NEAREST STRUCTURE WASH WATER OF ANY SORT SHALL NOT BE DISCHARGED TO THE STORM DRAIN SYSTEM OR SURFACE WATERS. 22. DRAINAGE PIPE WITHIN THE RIGHT OF WAY WITH LESS THAN 2 FEET OF COVER SHALL BE DUCTILE IRON. 23. CONTRACTOR SFIA1 FIELD VERIFY I.E. AT ALL CONNECTIONS TO EXISTING. IF MEASURED I.E. DOES NOT MATCH I.E. SHOWN ON THESE DRAWINGS, CALL ENGINEER PRIOR TO COMMENCING CONNECTION. I WRITERS, LLl-IYf IFI F�1JR Yq S[CIIOII TIFF ALLOWAIICR$ r...N01L ..~� 3 REVISED PER CITY COMMENTS 2 REVISED PER CITY COMMENTS N.W W481E N0. REVISION AUNv.wc v aim 'rom.oesal fr emwru.P,c y, mTa Wc.m+mr am�AC ,tt,CN ,RIF.Lr „ I aTo. Ws.vpp O . R.a6w19114rElm,BE Tf.N19E.91NE ■ma 1. NmpOEb-enSlw.bror.SeelOwrbro PW[CAE7MEE LLCIENSmNwCJnaErlpbroEOMSC epeea ea eIw rwdNhEI ro Hnl.n np,LLrtl O.124.1wSW1rerwwe SORT b ro ALl-EMIeE PRFWrEAESFLI-X. .NenreMrr rrotbpmmEOro bubr4 z m.mom,rtm.,.r.a.noleev.eweNII b *Sfi mnaeNeltlim�rr nMAenb28 WNII III IN JNANOWw4.m-" a emu.°`btwmllArllro'.1ww h .m smRB.a so.aiml, ra°s° a Ift ".m mobarrermrn.aFtl,brobwrne.bwl rrar. • TTw.NrN.M Or,mNlMbrrrl M,roSNpC.IwE a TINPrewr¢eW EerSmm.yeewerwNee S,w, alrowYTr4r e...parSJra,a4wwrr. a TIo.pSIY¢"In mrNrrro LparopetalEew W,bE 7. NptJ.pl„1,.NMPaYONul,iro0Yr1O.0een ONUE. a Wb WON ]WL BND.D18G - 1Ave1 "I, GGNINAOJ Y.HEY s?rc LEO SIJENAIN NAY BE A'JI CENT Ir: CONTRACT TO A wn:1 (SEE OETA'L) SIDEWALK VAPJES - 6 0 MIN. (SEE CONTRACT) 1/ R. (TTP) CURB NOT zz zr ICCLOOEB BID NEMA P 1/0' EMPAOLDED aTPENNINES JOINT GILER CEMENT CONCRETE SIOEWAUK ADJACENT TO CURB RANDOM FILL FILTER PERF PIPE W" - 1 � WASHED ROCK . Call 2 Working Days Before You Dig 1-800-424-5555 itilities Underground Location Center (ID,MT,ND,OR,WA) wb ¢c LITCHFIELD ENGINEERING � r7 29476 12840 81ST AVENUE NE �'stDNAT 1A Kirkland, Washington 98034 91 (425) 821-5038 FAX (425) 821-5739 STAMP NOT VALID UNLESS SIGNED AND DATED 4 REVISED PER CITY COMMENTS 3 REVISED PER CITY COMMENTS 2 REVISED PER CITY COMMENTS 1 SUBMITTED TO CLIENT N0. REVISION IY PYroeT suE rEC11SN �mC PIP. ALLOWANCES -usu of ,NNLPIJbd NA.r WN4iE NP NLNRN WS IT 1 IY � i N �< z QN.BPm.KW,P i rn 3 1 C am�AC ,tt,CN 'e,w,ewimm� SWISS 1. N�pmpbrMsaesbror..Fr.,mbro FN!CNISNE IECIgN paCmaEmYrNbin BmrlE,rtl BpeSfWela x1a nNrinM¢emVAmm� E-aa,YgNebtlN,prb.rrl m uatlVMron.nl"am rsPl.W nGahw,Inus NlEA1MlNE PrEwr aNesEL•Iol,. vnl. n„eI, WII ere.orvabro bloNml.4. I Tlrkrc4vW 9smMYmY MEearearFtivl,9•. bodn4Ytl Aew eNr MNJwerY mlrlwn b2FeI Plw IW.1N Irelllr.wpP e.Ne.,romNarorPr.rroarw..aroepa Almrro Np.m IrWitl,NroS,prIM1lJbrrrwNrmemblp xnn ENntlF. BwmNrblsJNa L Ther,wmnumlc.rlrwl.wa tbtl F.d.mmebrlw.rmwt .I HWIN 4. TeM1emevtl BrW mNEeIMeMMNtlnlmliel4abmn. Ile nerve rly' b. mn Irt, IM1. e4uswr rew. a rn.rNwr¢ee.seoum erwrlm.amaeann..rmwu.llw ..repwr.rra,alaryF. e. Tle[gnlrg,M esmNF..errobeamePmrfi�..aw. 1. Ngtl.p MbtlWlbFwW bllabrOe YIWIw OeenpsxE. s I W\iEFW8AD.RCu(ndEINM1e Wt, °N,'. oN, RLIRCCWI `£' PD BPBARIMEYI' 'TENT COLRO nON SYOM -ru- VLO.10 NAA ICI 2008 /z I'- NIIL c" 6" 61DE1VAi.H T 1/2" R. I LEVEL 1" R. 'r'A EE 6 - U' MIN L . (STP CONRAC J O 4 a %a C0. J 1 R R>P) CURB NOT 2 .eft-`sp.c 2S NC!LOEO D J 910 ITEM EAS I/4" TREAIOLON NOTE, EXTEND IOEVALK TRANSVERSE nN141 REP RASE O JO NT FILLER �- JOINTS O INCLUDE RAISED EDGE EDGE DETaL MD[, SMI RAISED EDGE DETAIL VIREO PERI!AFTER CIMGVT CONCRETE SIOEWAL{ SRM N.IUI EDGE "TON'.TR ROUNDING - 11GES (SEE JONAGr) CONCRETE CURD v EN svEa.mD smEwALv MAY Be ADJAEPII C \YALE OR HARMER NO cuTTER sNaxNl `'N CONrRAcr TO A WALL (sEE DEIaIL) UNE. IN 9!U 111. \ 50 EWALK VARIES ^ SIDEWALK I- (HEC CUNTRACr) X1/2 R rTw) 1.2,• R. ACE SCE CURB FU`JNL 1/A" PREMELDE1] JOINT FILLER Marvcunnc CENTRE concPBTE NRB AND SCLAATA - V smewALK ADJACENT TO VIA'_L DETAIL SLOPE RCUAD_NC - VARIES (SEE QCOIRACT) xHdn s'fCIIIcD 111.A!M MAT 9E ADJAGENT �N cUNrri ncT rU AIVALL (sEE BLTNr SICONTA P.UFfEF STEPG_ VHR CS 5 0 N:N'. \ RIES O G ) !. � EE NYTRA T) (SEE CONTRACT) 2f. 2,. 'INS DB IN fill ITEM h JO 'KC.K��� PFEMOLB°B CEMENT CONCRETE SIDEWALK� JOINT FILLER ADJACENT TO BI STRIP `l EXPANSION JOINT slope _ PLAN VIEW OF ROOF NTS KAL 17-21-14 KAL BY I DATE I APPR to road drainage system 1 ;vel trent ' w/pert pipe No°oa°7-, ISSUED, NTS KAL SAME KAL DATUM CHBI .,Mm KAL F NIN ME MM AFf4KWA r MMO.mr KAL SUBMITTED TO CLIENT 4" PERMEABLE PAVEMENT SEE C - FACE OE CURS CONTRACTION JOINT 5 1/2' 11-' . � TOE UP A'J L1/2RC1YAr Iz' NOTE: EXTEND S:D7VIA& TRANSVERSE EXPANSON :qN3 TO INCLUDE CURB (FULL DEPM) CURB FACE DETAIL A" TO 1/< � 0 9. Z ° TO 1. t0 I O CON'TRACTIQ`: JOINT CEMENT CONCRETE SIDF.A'AIX R-316005 I y p '{ 1 m O 3 � i N �< z m i rn 3 1 U1 I D O I y p '{ 1 m O 3 N �< z O i rn 3 1 U1 I I O CITY OF RENTON 6" FREE DRAINING APPROVED BY: DATE: p OR GRAVEL BASE APPROVED BY: DATE IVU PERMEABLE PAVEMENT DETAIL APPROVED B DATE: 1-04gY_ APPROVED BY: DATE: 3 _ CITY OF BLAKEY TOWNHOMES X12-3-13 RENTON 604 MORRIS AVENUE S RECORD IWAS RENTON, WA 98055 SUNNI Planning/Building/Public Works Dept. DRAINAGE & PAVING DETAILS & NOTES SRI 5 SI