HomeMy WebLinkAboutR-382807Ld Q Z U LtJ O W J ccm Q 0 Q.J 0 0 2 U Q H Z W W J W Y Q Z Q LLH 0 0 IL } U J m FRAME AND VANED GRATE h 2-A",6", 6", 12", OR 24" ONE #3 BAR FOR 6" HEIGHT INCREMENT (SPACED EQUALLY) RECTANGULAR ADJUSTMENT SECTION PIPE ALLOWANCES CATCH BASIN DIAMETER MAXIMUM PIPE MATERIAL INSIDE MINIMUM DISTANCE BETWEEN KNOCKOUTS DIAMETER REINFORCED OR 12" PLAIN CONCRETE 8" ALL METAL PIPE 15" CPSSP * 12" (STD. SPEC. 9-05.20) No SOLID WALL PVC 15" (STD. SPEC. 9-05.12(1)) ON PROFILE WALL PVC 15" (STD. SPEC. 945.12(2)) G0w �1c CORRUGATED POLYETHYLENE STORM SEWER PIPE #3 BAR EACH CORNER _ 18" MIN. #3 BAR HOOP WSDOT STANDARD PLAN B=5.20=01, NOT TO SCALE D 20" x 24" 24" DIAM., 48" DIAM. f �� OR 54" DIAM. HOLE 06 BARS Q 7" SPACING 2" (TYP.) �- 1" MIN. 2 1/2" MAX. 84" or 96" FLAT SLAB TOP #5 BARS (g'j 6" SPACING 20" x 24", / 24" DIAM., 48" DIAM, OR 54" DIAM. HOLE 2" (TYP.) -• L co 4 ___... 4.... 1.. MIN. 2 112" MAX. 72" FLAT SLAB TOP - #4 BARS 6" SPACING 20"x24"ORS 24" DIAM. HOLE 2" (TYP.) .............. a> 1" MIN. 2 1/2" MAX. 48", 54", or 60" FLAT SLAB TOP TYPICAL ORIENTATION FOR ACCESS AND STEPS 24" MIN. 48" MIN. ECCENTRIC CONE SECTION NOTES 1. As acceptable aitematives to the rebar shown in the PRECAST BASE SECTION, fibers (placed according to the Standard Specifications), or wire mesh having a minimum area of 0.12 square inches per foot shall be used with the minimum required rebar shown in the ALTERNATIVE PRECAST BASE SECTION. Wire mesh shall not be placed in the knockouts. 2. The knockout diameter shall not be greater than 20". Knockouts shall have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5" minimum gap between the knockout wall and the outside of the pipe. After the pipe is installed, fill the gap with joint mortar in accordance with Standard Specification 9-04.3. 3. The maximum depth from the finished grade to the lowest pipe invert shall be 5'. 4. The frame and grate may be installed with the flange down, or integrally cast into the adjustment section with flange up. 5. The Precast Base Section may have a rounded floor, and the walls may be sloped at a rate of 1:24 or steeper. 6. The opening shall be measured at the top of the Precast Base Section. 7. All pickup holes shall be grouted full after the basin has been placed. (SEE NOTE 1) ALTERNATIVE PRECAST BASE SECTION 12" MIN. - ------------ - .. - aD NiZ STEP s" 6" OR 12" J N 44535 s3 o, ., CATCH BASIN TYPE 1 STANDARD PLAN B-5.20-01 SHEET 1 OF 1 SHEET APPROVED FOR PUBLICATION Pasco Bakotich III 06-16-11 STATE DESIGN ENGINEER DATE Washington Slab Depar"nent of Transportation NOTE Ladder rungs for manholes and catch basins shall meet the requirements of AASHTO M 199. 12" (TYP) ONE #3 BAR HOOP FOR 6" 1 TWO #3 BAR HOOPS FOR 12" 0 RECTANGULAR ADJUSTMENT SECTION As an acceptable alternative to rebar, wire mesh having a minimum area of 0.12 square inches per foot may be used for adjustment sections. 34" .2 1O ONE #3 BAR HOOP - 4 - CIRCULAR ADJUSTMENT SECTION bo 6" 12" PREFABRICATED LADDER ii W m F' 07 � J -151 �0 15588 EXPIRES JULY I, 2009 MISCELLANEOUS DETAILS FOR DRAINAGE STRUCTURES STANDARD PLAN 3-30.90-01 SHEET 1 OF 1 SHEET APPROVED FOR PUBLICATION Pasco Bakotich Ill 09-20-07 STATE DESIGN ENGINEER DATE Washington State Department of Transportation 0 0 U. U M M z CATCH BASIN FRAME AND VANED GRATE OR MANHOLE RING AND COVER RECTANGULAR ADJUSTMENT SECTION OR CIRCULAR ADJUSTMENT SECTION FLAT SLAB TOP MORTAR (TYP.) - REINFORCING STEEL (TYP.) GRAVEL BACKFILL FOR PIPE ZONE BEDDING / irs SEPARATE BASE INTEGRAL BASE PRECAST PRECAST WITH RISER (48" - 72" ONLY) WSDOT STANDARD PLAN B=10.20=01, NOT TO SCALE BID SET NmxnCAL- NAM HONIZOOML• WO M1 00 3/101 DATUM NOTES 1. No steps are required when height is 4' or less. 2. The bottom of the precast catch basin may be sloped to facilitate cleaning. 3. The rectangular frame and grate may be installed with the flange up or down. The frame may be cast into the adjustment section. 4. Knockouts shall have a wall thickness of 2" minimum to 2.5" maximum. Provide a 1.5" minimum gap between the knockout wall and the outside of the pipe. After the pipe is installed, fill the gap with joint mortar in accordance with Standard Sp�cMcato, n 8-04.3. CATCH BASIN DIMENSIONS CATCH BASIN DIAMETER MIN. WALL THICKNESS MIN. BASE THICKNESS MAXIMUM KNOCKOUT SIZE MINIMUM DISTANCE BETWEEN KNOCKOUTS 48" 4" 6" 36" 8" 54" 4.5" 8" 42" 8" No 5N QN Q41 ON 72" 6" 8" G0w 12N 84" 8" 12" 42" 12" 96" 8" 12" p72" O" a 12" 120" 10" 12" 96" 12" 144" 12" 12" 108" 12" PIPE ALLOWANCES CATCH BASIN DIAMETER PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER CONCRETE ALL METAL CPSSP O SOLID WALL PVC Co PROFILE WALL PVC 03 48" 24" 30" 24" 0 �Uq LIN W" '%" 30" W W" 60w 3366" 42" 36/" 42" 42" 72" 42" 54" 42" 84" 54" 60" 54" 48" 48" 96" 60" 72" 60" 48" 48" 120m 66 84" 60N �w 48" 144" 78" 96- 60- 48- w ON 0 Corrugated Polyethylene Storm Sewer Pipe (Standard Specification 9-05.20) 2� (Standard Specification 945.12(1)) (Standard Specification 9.05.12(2)) Checked for Complia a to City Standards f / l 00, fiz:24 IN �I CITY OF RENTON Planning/Building/Public Works Dept. by h I C -10 0 �44535 trss GI STO ZONAL CATCH BASIN TYPE 2 STANDARD PLAN B-10.20-01 SHEET 1 OF 1 SHEET APPROVED FOR PUBLICATION Pasco Bakodch 111 02-07-12 STATE DESIGN ENGINEER DATE Adft WslshiStas Dsportmer t of Tranports ien NOTICE t 1-1 v v IVI 1-% vL-� I I t -L- vr- vrv%t'4L- I t��-vt t 111--%J AL1MA11N1 OF IMS DOMOU SHALL NYA =1E 1W PNORSIM SEAL AND NUME PLUM10 OF N 2215 North 30th Street, Suite 300 Tacoma, WA 98403 ONLY Fa IME PNO�i �1l6) N 1fE 111<E ROCK NO 6 Nor M E UM M M. ISM OR 253.383.2422 TEL 253.383.2572 FAX www.ahbl.com WEB MW= TO VAT Pyr OR FOR ANY 0961 PRUU DATE: TIFFANY PARK ELEMENTARY SCHOOL 20 APRIL 2015 PORTABLES P#AE- m RENTON SCHOOL DISTRICT olwlwN: W. C4.3 NOTES AND DETAILS �: �: Cn > T1 n 0 �o �C:D C Un 71 �� rn n� n 'z z M Cn 0 > °=1 z L7 c� V o z M M� CD c c c D 0 �Uq � n ��M O �N O M T1 Con MT1 n > Cn > T1 n 0 �o �C:D C Un 71 �� rn n� n 'z z M Cn 0 > °=1 L7 V o M M� CD c c I CD D D 0 �Uq � n ��M O �N O to Con D L7 V o M M� CD c c D � C a OCI ��M