Loading...
HomeMy WebLinkAboutR-32683171, z z fL� LC a LIJ Z6 •o U� L0 CnE Z 0 A J X' N 0 o� ci 0 0 U r 'a Cn C) C) v N "o CL 0 0 N r_ cc E 0 LO 0 0 N N 0 C IRRIGATION SCHEDULE RAINBIRD 1800 -SAM -PRS -10 SERIES POP-UP SPRAY HEADS 10' B its 491 RADIUS AT 30 P.S.I. PROVIDE &INSTALL APPROPRIATE ARC NOZZLE TO 4" SLF,VE� LS5 FIT ANY SHAPE OF PLANTING AREA. 12" POP-UP IN GROUNDCOVER/ �LS5ILS5 - — — - PIPE SLEEVES (CLASS 200 PVC) W/ SIZE -SEE CIVIL SHRUB AREAS. 4 POP-UP IN LAWN AREAS. DRWG S. SEE SHEET LS6 FOR SLEEVE REQUIREMENTS. RAINBIRD 1800 -SAM -PRS -12 SERIES POP-UP SPRAY HEADS 12' rc 1 _ 1 /2" RADIUS AT 30 P.S.I. PROVIDE &INSTALL APPROPRIATE ARC NOZZLE TO LS5 LATERAL LINE (CLASS 200 PVC) W/ SIZE g s o o \L15 q 9 0 FIT ANY SHAPE OF PLANTING AREA. 12" POP-UP IN GROUNDCOVER/C 1-1 /2" MAINLINE SHRUB AREAS. 4" POP-UP IN LAWN AREAS. LS5 - — — — - MAINLINE (SCHED. 40 PVC) RAINBIRD 1800 -SAM -PRS -15 SERIES POP-UP SPRAY HEADS 15' F m 3/4" MANUAL DRAIN VALVE. CHAMPION 200RS-075 (3/4") B o 0 o RADIUS AT 30 P.S.I. PROVIDE &INSTALL APPROPRIATE ARC NOZZLE TO LS6 `7 DRAIN VALVE. PROVIDE OWNER W/ TWO (2) VALVE KEYS LS5 4 G)O FIT ANY SHAPE OF PLANTING AREA. 12 POP-UP IN GROUNDCOVER/ SHRUB AREAS. 4" POP-UP IN LAWN AREAS. QUICK COUPLING VALVES- RAINBIRD 44LRC W/ 44K COUPLER RAINBIRD 1800-SAM-PRS-I5SST SERIES POP-UP SIDE STRIP SPRAYC D KEY SH -1 HOSE SWIVEL & 2049 LID KEY; PROVIDE OWNER B � HEAD AT 30 P.S.I. PROVIDE &INSTALL APPROPRIATE ARC NOZZLE TO LS6 W/ TWO (2) SETS OF THE FOLLOWING: LS5 FIT ANY SHAPE OF PLANTING AREA. 12" POP-UP IN GROUNDCOVER/ COUPLER KEYS SHRUB AREAS. 4" POP-UP IN LAWN AREAS. G.P.M. HOSE SWIVELS CIRCUIT N0. /VALVE SIZE LID KEYS RAINBIRD 1800-SAM-PRS-I5EST SERIES POP-UP END STRIP SPRAY rB ED FIT AT 30 P.S.I. PROVIDE &INSTALL APPROPRIATE ARC NOZZLE TOK*A / \LS5 FIT ANY SHAPE OF PLANTING AREA. 12" POP-UP IN GROUNDCOVER/ S6 � AUTOMATIC CONTROL VALVES W/ SIZE- RAINBIRD PEB SERIES SHRUB AREAS. 4" POP-UP IN LAWN AREAS. �� LEGEND A LS DETAIL IDENTIFICATION SHEET IDENTIFICATION MANUAL DRAIN VALVE QUICK COUPLER BACKFLOW PREVENTER FLOW SENSOR MASTER CONTROL VALVE PVC MAINLINE 1-1 /2" METER - — SEE CIVIL DRWG'S. 0__ FLOW Tr DIRECTION ATE VALVE IRRIGATION POINT OF CONNECTION (P.O.C.) h NOT TO SCALE STATE OF WASHINGTON REGISTERED LANDSCAPE ARCHITECT COLEEN R. HOUGH CERTIFICATE NO. 318 FINISH GRADE 1" LAWN AREAS OR 2" GROUNDCOVER/ i7LTt= SHRUB AREAS POP—UP SPRAY HEAD ADJUST TO FINISH GRADE MARLEX 90 MARLEX 90 DEGREE DEGREE I STREET ELL STREET ELL �.�ARLEX 90 DEGREE SCHED. 40 � STREET ELL PVC BUSHING SCHED. 80 PVC RISER SIZE REQUIRED AS REQUIRED (g" MIN. LENGTH) (45 DEGREE MAX. PVC � ANGLE FROM HORIZONTAL POSITION) LATERAL LINE TRIPLE SWING JOINT RISER ASSEMBLY LAWN, SHRUG to GROUNDCOVER HEAD RISER ASSEMBLY POP—UP) NOT TO SCALE B OO 1-1/2" HAMMOND GATE VALVE MODEL 667 OR APPROVED EQUAL LS6 TORO SENTINEL SSAK12PS16NS(1 or 4) 12 LS6 STATION IRRIGATION CONTROLLER E TORO 220 2" MASTER CONTROL VALVE LS6 � #220-26-0-9 rE �. DATA INDUSTRIES 1-1/2" FLOW SENSOR #IR220P �LS6 rB p04 1-1/2" FEBCO 850Y BACKFLOW PREVENTER LS6 PER CODE REQUIREMENTS A aM 1-1/2" IRRIGATION WATER METER- SEE SHEET RP2 LS5 (INSTALLED BY CIN) rA � IRRIGATION POINT OF CONNECTION LS5 w w 00 NOTE: � ALL MAIN AND/OR LATERAL PIPE UNDER PAVEMENTS SHALL BE SLEEVED. SEE DETAIL � �L�S5 • • • • i • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • ! • • a • • a • • • • • • • • • • • • • • • ............... ............... ............... 0000... 00,00.. ............... 0000... 0000... .. 00000 ,. . • . , . . • '000 000!0• • • • i • . .• .0.000.• .• .......... ............... ............... ............... 0000.• 0000... ,0000.. 0000... ,0000 0000 0000 0000 ... •• .... .., .. .,., • 41* • • •�•�• ••••• • • ..• ... 0000 0000 .......... 0000. FINISH GRADE CONTINUOUS 2" BACKFILL MATERIAL (SEE SPECS) MATERIAL AROUND PIPE. TYPICAL BEDDING EACH PIPE PVC LATERAL LINE TRENCH COMPACTED BACKFILL (EARTH FILL) SEE SPECS. PVC MAI N LI N E WIRES FOR VALVES UNDER PIPE MPACT SUBGRADE MAIN AND/OR LATERAL PIPE TRENCH DETAIL NOT TO SCALE IRRIGATION NOTES fA STPUL 1. THERE IS A LOSS OF PRESSURE IN EACH PIPE FITTING DUE TO FRICTION & ADDITIONAL HEADS MAY BE NEEDED DUE TO FIELD CONDITIONS. THESE LOSSES ARE COMPENSATED FOR BY ADDING TEN (10) PERCENT TO THE MFR'S RATED G.P.M. FOR EACH NOZZLE. 2. LOCATE QUICK COUPLING VALVE &AUTOMATIC CONTROL VALVES IN SHRUB/ GROUNDCOVER AREAS AT POINT OF EASY ACCESS. ENG. TO REVIEW &APPROVE FINAL LOCATION OF ALL QUICK COUPLERS &AUTOMATIC CONTROL VALVES PRIOR TO INSTALLATION. 3. HEAD LOCATION MUST BE ADJUSTED IN THE FIELD TO COMPLY W/ EXIST'G SITE CONDITIONS, PLANT MATERIALS & ANY OTHER ITEMS DEEMED APPROPRIATE BY THE ENG. 4. EXIST'G STATIC P.S.I. AT IRRIGATION METER IS 58 P.S.I. INFORMATION PROVIDED BY PERTEET ENG., RECEIVED ON 6/11/03. PRIOR TO INSTALLATION OF IRRIGATION SYSTEM, CONTRACTOR SHALL FIELD VERIFY EXIST'G P.S.I. NOTIFY ENG. OF ANY DISCREPANCIES BETWEEN THE DESIGN P.S.I. & EXIST'G P.S.I. PRIOR TO PROCEEDING W/ WORK. 5. SYSTEM DESIGNED TO 30 P.S.I. (SPRAY HEADS). 6. IRRIGATION CONTRACTOR SHALL COORDINATE IRRIGATION SLEEVING LOCATIONS W/ GENERAL CONTRACTOR. 7. DRAWING IS SCHEMATIC. ACTUAL LOCATIONS MAY VARY DUE TO PLANT MATERIALS, UTILITIES OR EXIST'G CONDITIONS. CONTRACTOR IS RESPONSIBLE FOR LOCATING UTILITIES PRIOR TO BEGINNING CONSTRUCTION. CALL 1-800-424-5550 TWO (2) DAYS PRIOR TO DIGGING ON-SITE. 8. ALL IRRIGATION SLEEVING TO BE STAKED IN THE FIELD & LOCATED ON DIMENSIONED "AS -BUILT" DRAWING TO ALLOW FUTURE LOCATION & USE. 9. AIR BLOW IRRIGATION SYSTEM THROUGH QUICK COUPLERS TO WINTERIZE IRRIGATION SYSTEM. 10. A MIN. TWO (2) WEEKS PRIOR TO BEGINNING DEMOLITION WORK, CONTRACTOR SHALL CONTACT MR. TERRY FLATLEY AT THE CITY OF RENTON PARKS DIVISION (425) 430-6600 TO DOCUMENT THE WORKING ORDER OF EXIST'G IRRIGATION SYSTEM. CONTRACTOR IS RESPONSIBLE FOR PROTECTING AND/OR RESTORING THE EXIST'G IRRIGATION SYSTEM DAMAGED BY CONSTRUCTION TO ITS PRE -CONSTRUCTION CONDITION PER FORCE ACCOUNT ITEM "RESTORATION OF EXISTING IRRIGATION SYSTEM", SEE SPECS. 11. WHERE PIPE SIZES ARE NOT SHOWN ON THE PLAN, PIPE SHALL BE SIZED TO THE NEXT LARGEST PIPE SIZE SHOWN UPSTREAM ON THE PLAN. 12. SEE SHEET LS2 FOR ABBREVIATIONS. w w 00 u PAVING & BASE COURSE, SEE CIVIL DRWG'S / - °•'.4 ° -A v'° 4 - v ° = �d G c a - ° ° / °- d„ 0 'J If III I �� ~•.�-�•�'�•� ' �~���. I III • •:,. �• ,... :•. I .,:.�-..�.-:•;...::: III 1 I I I • .- . .. ::0000. ,' ' •. y " I El I I--_ •, ,•... - .. %J. - 1 �J =I = ~.'• - '�s ~.�::_ �' CRUSHED SURFACING TOP �''�' • • = I I COURSE, COMPACT TO 95% �. - .. � �.•. - .•z • 00«00. •. • -s • • • - • y• ' - - s MAX. DENSITY III ..y..-..' 2 PIPE SLEEVE W/ IRRIGATION IE,1• �= •PIPE & CONTROL WIRES - :.�-:• III- . •� ti • ••• z• ' : WIRES FOR VALVES UNDER PIPE. III=III— III �1=U I F �'t'iT�— COMPACT SUBGRADE PIPE SLEEVE NOT TO SCALE R-326831. Q erteet Inc. 425-252-770011-800-615-9900RENTONJH�� 2707 Colby Avenue, suite soo Everett, Washington 98201 z �: � _ ; -:_.= HOugh Beck & Ba1rd Inc LANDSCAPE ARCHITECTURE URBANPLANNIN ESIGN z i ZC 1 L L MAPLE VALLEY HIGHWAY (SR 169) CEDAR RIVER PARK ACCESS IMPROVEMENTS RR SCHED, IRR NOTES, LEGEND & DETAILS L0 CnE Z 0 A J X' N 0 o� ci 0 0 U r 'a Cn C) C) v N "o CL 0 0 N r_ cc E 0 LO 0 0 N N 0 C IRRIGATION SCHEDULE RAINBIRD 1800 -SAM -PRS -10 SERIES POP-UP SPRAY HEADS 10' B its 491 RADIUS AT 30 P.S.I. PROVIDE &INSTALL APPROPRIATE ARC NOZZLE TO 4" SLF,VE� LS5 FIT ANY SHAPE OF PLANTING AREA. 12" POP-UP IN GROUNDCOVER/ �LS5ILS5 - — — - PIPE SLEEVES (CLASS 200 PVC) W/ SIZE -SEE CIVIL SHRUB AREAS. 4 POP-UP IN LAWN AREAS. DRWG S. SEE SHEET LS6 FOR SLEEVE REQUIREMENTS. RAINBIRD 1800 -SAM -PRS -12 SERIES POP-UP SPRAY HEADS 12' rc 1 _ 1 /2" RADIUS AT 30 P.S.I. PROVIDE &INSTALL APPROPRIATE ARC NOZZLE TO LS5 LATERAL LINE (CLASS 200 PVC) W/ SIZE g s o o \L15 q 9 0 FIT ANY SHAPE OF PLANTING AREA. 12" POP-UP IN GROUNDCOVER/C 1-1 /2" MAINLINE SHRUB AREAS. 4" POP-UP IN LAWN AREAS. LS5 - — — — - MAINLINE (SCHED. 40 PVC) RAINBIRD 1800 -SAM -PRS -15 SERIES POP-UP SPRAY HEADS 15' F m 3/4" MANUAL DRAIN VALVE. CHAMPION 200RS-075 (3/4") B o 0 o RADIUS AT 30 P.S.I. PROVIDE &INSTALL APPROPRIATE ARC NOZZLE TO LS6 `7 DRAIN VALVE. PROVIDE OWNER W/ TWO (2) VALVE KEYS LS5 4 G)O FIT ANY SHAPE OF PLANTING AREA. 12 POP-UP IN GROUNDCOVER/ SHRUB AREAS. 4" POP-UP IN LAWN AREAS. QUICK COUPLING VALVES- RAINBIRD 44LRC W/ 44K COUPLER RAINBIRD 1800-SAM-PRS-I5SST SERIES POP-UP SIDE STRIP SPRAYC D KEY SH -1 HOSE SWIVEL & 2049 LID KEY; PROVIDE OWNER B � HEAD AT 30 P.S.I. PROVIDE &INSTALL APPROPRIATE ARC NOZZLE TO LS6 W/ TWO (2) SETS OF THE FOLLOWING: LS5 FIT ANY SHAPE OF PLANTING AREA. 12" POP-UP IN GROUNDCOVER/ COUPLER KEYS SHRUB AREAS. 4" POP-UP IN LAWN AREAS. G.P.M. HOSE SWIVELS CIRCUIT N0. /VALVE SIZE LID KEYS RAINBIRD 1800-SAM-PRS-I5EST SERIES POP-UP END STRIP SPRAY rB ED FIT AT 30 P.S.I. PROVIDE &INSTALL APPROPRIATE ARC NOZZLE TOK*A / \LS5 FIT ANY SHAPE OF PLANTING AREA. 12" POP-UP IN GROUNDCOVER/ S6 � AUTOMATIC CONTROL VALVES W/ SIZE- RAINBIRD PEB SERIES SHRUB AREAS. 4" POP-UP IN LAWN AREAS. �� LEGEND A LS DETAIL IDENTIFICATION SHEET IDENTIFICATION MANUAL DRAIN VALVE QUICK COUPLER BACKFLOW PREVENTER FLOW SENSOR MASTER CONTROL VALVE PVC MAINLINE 1-1 /2" METER - — SEE CIVIL DRWG'S. 0__ FLOW Tr DIRECTION ATE VALVE IRRIGATION POINT OF CONNECTION (P.O.C.) h NOT TO SCALE STATE OF WASHINGTON REGISTERED LANDSCAPE ARCHITECT COLEEN R. HOUGH CERTIFICATE NO. 318 FINISH GRADE 1" LAWN AREAS OR 2" GROUNDCOVER/ i7LTt= SHRUB AREAS POP—UP SPRAY HEAD ADJUST TO FINISH GRADE MARLEX 90 MARLEX 90 DEGREE DEGREE I STREET ELL STREET ELL �.�ARLEX 90 DEGREE SCHED. 40 � STREET ELL PVC BUSHING SCHED. 80 PVC RISER SIZE REQUIRED AS REQUIRED (g" MIN. LENGTH) (45 DEGREE MAX. PVC � ANGLE FROM HORIZONTAL POSITION) LATERAL LINE TRIPLE SWING JOINT RISER ASSEMBLY LAWN, SHRUG to GROUNDCOVER HEAD RISER ASSEMBLY POP—UP) NOT TO SCALE B OO 1-1/2" HAMMOND GATE VALVE MODEL 667 OR APPROVED EQUAL LS6 TORO SENTINEL SSAK12PS16NS(1 or 4) 12 LS6 STATION IRRIGATION CONTROLLER E TORO 220 2" MASTER CONTROL VALVE LS6 � #220-26-0-9 rE �. DATA INDUSTRIES 1-1/2" FLOW SENSOR #IR220P �LS6 rB p04 1-1/2" FEBCO 850Y BACKFLOW PREVENTER LS6 PER CODE REQUIREMENTS A aM 1-1/2" IRRIGATION WATER METER- SEE SHEET RP2 LS5 (INSTALLED BY CIN) rA � IRRIGATION POINT OF CONNECTION LS5 w w 00 NOTE: � ALL MAIN AND/OR LATERAL PIPE UNDER PAVEMENTS SHALL BE SLEEVED. SEE DETAIL � �L�S5 • • • • i • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • ! • • a • • a • • • • • • • • • • • • • • • ............... ............... ............... 0000... 00,00.. ............... 0000... 0000... .. 00000 ,. . • . , . . • '000 000!0• • • • i • . .• .0.000.• .• .......... ............... ............... ............... 0000.• 0000... ,0000.. 0000... ,0000 0000 0000 0000 ... •• .... .., .. .,., • 41* • • •�•�• ••••• • • ..• ... 0000 0000 .......... 0000. FINISH GRADE CONTINUOUS 2" BACKFILL MATERIAL (SEE SPECS) MATERIAL AROUND PIPE. TYPICAL BEDDING EACH PIPE PVC LATERAL LINE TRENCH COMPACTED BACKFILL (EARTH FILL) SEE SPECS. PVC MAI N LI N E WIRES FOR VALVES UNDER PIPE MPACT SUBGRADE MAIN AND/OR LATERAL PIPE TRENCH DETAIL NOT TO SCALE IRRIGATION NOTES fA STPUL 1. THERE IS A LOSS OF PRESSURE IN EACH PIPE FITTING DUE TO FRICTION & ADDITIONAL HEADS MAY BE NEEDED DUE TO FIELD CONDITIONS. THESE LOSSES ARE COMPENSATED FOR BY ADDING TEN (10) PERCENT TO THE MFR'S RATED G.P.M. FOR EACH NOZZLE. 2. LOCATE QUICK COUPLING VALVE &AUTOMATIC CONTROL VALVES IN SHRUB/ GROUNDCOVER AREAS AT POINT OF EASY ACCESS. ENG. TO REVIEW &APPROVE FINAL LOCATION OF ALL QUICK COUPLERS &AUTOMATIC CONTROL VALVES PRIOR TO INSTALLATION. 3. HEAD LOCATION MUST BE ADJUSTED IN THE FIELD TO COMPLY W/ EXIST'G SITE CONDITIONS, PLANT MATERIALS & ANY OTHER ITEMS DEEMED APPROPRIATE BY THE ENG. 4. EXIST'G STATIC P.S.I. AT IRRIGATION METER IS 58 P.S.I. INFORMATION PROVIDED BY PERTEET ENG., RECEIVED ON 6/11/03. PRIOR TO INSTALLATION OF IRRIGATION SYSTEM, CONTRACTOR SHALL FIELD VERIFY EXIST'G P.S.I. NOTIFY ENG. OF ANY DISCREPANCIES BETWEEN THE DESIGN P.S.I. & EXIST'G P.S.I. PRIOR TO PROCEEDING W/ WORK. 5. SYSTEM DESIGNED TO 30 P.S.I. (SPRAY HEADS). 6. IRRIGATION CONTRACTOR SHALL COORDINATE IRRIGATION SLEEVING LOCATIONS W/ GENERAL CONTRACTOR. 7. DRAWING IS SCHEMATIC. ACTUAL LOCATIONS MAY VARY DUE TO PLANT MATERIALS, UTILITIES OR EXIST'G CONDITIONS. CONTRACTOR IS RESPONSIBLE FOR LOCATING UTILITIES PRIOR TO BEGINNING CONSTRUCTION. CALL 1-800-424-5550 TWO (2) DAYS PRIOR TO DIGGING ON-SITE. 8. ALL IRRIGATION SLEEVING TO BE STAKED IN THE FIELD & LOCATED ON DIMENSIONED "AS -BUILT" DRAWING TO ALLOW FUTURE LOCATION & USE. 9. AIR BLOW IRRIGATION SYSTEM THROUGH QUICK COUPLERS TO WINTERIZE IRRIGATION SYSTEM. 10. A MIN. TWO (2) WEEKS PRIOR TO BEGINNING DEMOLITION WORK, CONTRACTOR SHALL CONTACT MR. TERRY FLATLEY AT THE CITY OF RENTON PARKS DIVISION (425) 430-6600 TO DOCUMENT THE WORKING ORDER OF EXIST'G IRRIGATION SYSTEM. CONTRACTOR IS RESPONSIBLE FOR PROTECTING AND/OR RESTORING THE EXIST'G IRRIGATION SYSTEM DAMAGED BY CONSTRUCTION TO ITS PRE -CONSTRUCTION CONDITION PER FORCE ACCOUNT ITEM "RESTORATION OF EXISTING IRRIGATION SYSTEM", SEE SPECS. 11. WHERE PIPE SIZES ARE NOT SHOWN ON THE PLAN, PIPE SHALL BE SIZED TO THE NEXT LARGEST PIPE SIZE SHOWN UPSTREAM ON THE PLAN. 12. SEE SHEET LS2 FOR ABBREVIATIONS. w w 00 u PAVING & BASE COURSE, SEE CIVIL DRWG'S / - °•'.4 ° -A v'° 4 - v ° = �d G c a - ° ° / °- d„ 0 'J If III I �� ~•.�-�•�'�•� ' �~���. I III • •:,. �• ,... :•. I .,:.�-..�.-:•;...::: III 1 I I I • .- . .. ::0000. ,' ' •. y " I El I I--_ •, ,•... - .. %J. - 1 �J =I = ~.'• - '�s ~.�::_ �' CRUSHED SURFACING TOP �''�' • • = I I COURSE, COMPACT TO 95% �. - .. � �.•. - .•z • 00«00. •. • -s • • • - • y• ' - - s MAX. DENSITY III ..y..-..' 2 PIPE SLEEVE W/ IRRIGATION IE,1• �= •PIPE & CONTROL WIRES - :.�-:• III- . •� ti • ••• z• ' : WIRES FOR VALVES UNDER PIPE. III=III— III �1=U I F �'t'iT�— COMPACT SUBGRADE PIPE SLEEVE NOT TO SCALE R-326831. erteet Inc. 425-252-770011-800-615-9900RENTONJH�� 2707 Colby Avenue, suite soo Everett, Washington 98201 z �: � _ ; -:_.= HOugh Beck & Ba1rd Inc LANDSCAPE ARCHITECTURE URBANPLANNIN ESIGN Drown �, �, Designed � �,�LS5 �, � e � Approved" � CITY OF RENTON°`°""�"°� MAPLE VALLEY HIGHWAY (SR 169) CEDAR RIVER PARK ACCESS IMPROVEMENTS RR SCHED, IRR NOTES, LEGEND & DETAILS �,� �� No. 31 of3� �'� � � ,�. �� Rte, er nom•