HomeMy WebLinkAboutR-32683171,
z
z
fL�
LC
a
LIJ
Z6
•o
U�
L0
CnE
Z
0
A
J
X'
N
0
o�
ci
0
0
U
r
'a
Cn
C)
C)
v
N
"o
CL
0
0
N
r_
cc
E
0
LO
0
0
N
N
0
C
IRRIGATION SCHEDULE
RAINBIRD 1800 -SAM -PRS -10 SERIES POP-UP SPRAY HEADS 10'
B its 491 RADIUS AT 30 P.S.I. PROVIDE &INSTALL APPROPRIATE ARC NOZZLE TO 4" SLF,VE�
LS5 FIT ANY SHAPE OF PLANTING AREA. 12" POP-UP IN GROUNDCOVER/ �LS5ILS5 - — — - PIPE SLEEVES (CLASS 200 PVC) W/ SIZE -SEE CIVIL
SHRUB AREAS. 4 POP-UP IN LAWN AREAS. DRWG S. SEE SHEET LS6 FOR SLEEVE REQUIREMENTS.
RAINBIRD 1800 -SAM -PRS -12 SERIES POP-UP SPRAY HEADS 12' rc 1 _ 1 /2"
RADIUS AT 30 P.S.I. PROVIDE &INSTALL APPROPRIATE ARC NOZZLE TO LS5 LATERAL LINE (CLASS 200 PVC) W/ SIZE
g s o o
\L15 q 9 0 FIT ANY SHAPE OF PLANTING AREA. 12" POP-UP IN GROUNDCOVER/C 1-1 /2" MAINLINE
SHRUB AREAS. 4" POP-UP IN LAWN AREAS. LS5 - — — — - MAINLINE (SCHED. 40 PVC)
RAINBIRD 1800 -SAM -PRS -15 SERIES POP-UP SPRAY HEADS 15' F m 3/4" MANUAL DRAIN VALVE. CHAMPION 200RS-075 (3/4")
B o 0 o RADIUS AT 30 P.S.I. PROVIDE &INSTALL APPROPRIATE ARC NOZZLE TO LS6 `7 DRAIN VALVE. PROVIDE OWNER W/ TWO (2) VALVE KEYS
LS5 4 G)O FIT ANY SHAPE OF PLANTING AREA. 12 POP-UP IN GROUNDCOVER/
SHRUB AREAS. 4" POP-UP IN LAWN AREAS. QUICK COUPLING VALVES- RAINBIRD 44LRC W/ 44K COUPLER
RAINBIRD 1800-SAM-PRS-I5SST SERIES POP-UP SIDE STRIP SPRAYC D KEY SH -1 HOSE SWIVEL & 2049 LID KEY; PROVIDE OWNER
B � HEAD AT 30 P.S.I. PROVIDE &INSTALL APPROPRIATE ARC NOZZLE TO LS6 W/ TWO (2) SETS OF THE FOLLOWING:
LS5 FIT ANY SHAPE OF PLANTING AREA. 12" POP-UP IN GROUNDCOVER/ COUPLER KEYS
SHRUB AREAS. 4" POP-UP IN LAWN AREAS. G.P.M. HOSE SWIVELS
CIRCUIT N0. /VALVE SIZE LID KEYS
RAINBIRD 1800-SAM-PRS-I5EST SERIES POP-UP END STRIP SPRAY
rB ED FIT
AT 30 P.S.I. PROVIDE &INSTALL APPROPRIATE ARC NOZZLE TOK*A /
\LS5 FIT ANY SHAPE OF PLANTING AREA. 12" POP-UP IN GROUNDCOVER/ S6 � AUTOMATIC CONTROL VALVES W/ SIZE- RAINBIRD PEB SERIES
SHRUB AREAS. 4" POP-UP IN LAWN AREAS. ��
LEGEND
A
LS
DETAIL IDENTIFICATION
SHEET IDENTIFICATION
MANUAL DRAIN VALVE
QUICK COUPLER
BACKFLOW PREVENTER
FLOW SENSOR
MASTER CONTROL VALVE
PVC MAINLINE 1-1 /2" METER -
— SEE CIVIL DRWG'S.
0__
FLOW Tr
DIRECTION ATE VALVE
IRRIGATION POINT OF CONNECTION (P.O.C.)
h NOT TO SCALE
STATE OF
WASHINGTON
REGISTERED
LANDSCAPE ARCHITECT
COLEEN R. HOUGH
CERTIFICATE NO. 318
FINISH GRADE
1" LAWN AREAS OR
2" GROUNDCOVER/
i7LTt=
SHRUB AREAS
POP—UP SPRAY HEAD
ADJUST TO FINISH GRADE
MARLEX 90 MARLEX 90 DEGREE
DEGREE I STREET ELL
STREET ELL �.�ARLEX 90 DEGREE
SCHED. 40 � STREET ELL
PVC BUSHING SCHED. 80 PVC RISER SIZE REQUIRED
AS REQUIRED (g" MIN. LENGTH) (45 DEGREE MAX.
PVC � ANGLE FROM HORIZONTAL POSITION)
LATERAL
LINE TRIPLE SWING JOINT RISER ASSEMBLY
LAWN, SHRUG to GROUNDCOVER HEAD RISER ASSEMBLY POP—UP)
NOT TO SCALE
B OO 1-1/2" HAMMOND GATE VALVE MODEL 667 OR APPROVED EQUAL
LS6
TORO SENTINEL SSAK12PS16NS(1 or 4) 12
LS6 STATION IRRIGATION CONTROLLER
E TORO 220 2" MASTER CONTROL VALVE
LS6 � #220-26-0-9
rE �. DATA INDUSTRIES 1-1/2" FLOW SENSOR #IR220P
�LS6
rB p04 1-1/2" FEBCO 850Y BACKFLOW PREVENTER
LS6 PER CODE REQUIREMENTS
A aM 1-1/2" IRRIGATION WATER METER- SEE SHEET RP2
LS5 (INSTALLED BY CIN)
rA � IRRIGATION POINT OF CONNECTION
LS5
w
w
00
NOTE: �
ALL MAIN AND/OR
LATERAL PIPE UNDER
PAVEMENTS SHALL BE
SLEEVED.
SEE DETAIL �
�L�S5
• • • • i • • • • • • • • • •
• • • • • • • • • • • • • • •
• • • • • • • ! • • a • • a
• • • • • • • • • • • • • • •
...............
...............
...............
0000... 00,00..
...............
0000... 0000...
..
00000
,.
. • . , . .
•
'000
000!0• • • • i • .
.• .0.000.• .•
..........
...............
...............
...............
0000.• 0000...
,0000.. 0000...
,0000 0000
0000 0000
... ••
....
..,
.. .,.,
• 41*
• •
•�•�•
•••••
• •
..• ...
0000 0000
..........
0000.
FINISH GRADE
CONTINUOUS 2" BACKFILL
MATERIAL (SEE SPECS) MATERIAL
AROUND PIPE. TYPICAL BEDDING
EACH PIPE
PVC LATERAL LINE
TRENCH COMPACTED BACKFILL
(EARTH FILL) SEE SPECS.
PVC MAI N LI N E
WIRES FOR VALVES
UNDER PIPE
MPACT SUBGRADE
MAIN AND/OR LATERAL
PIPE TRENCH DETAIL
NOT TO SCALE
IRRIGATION NOTES
fA STPUL
1. THERE IS A LOSS OF PRESSURE IN EACH PIPE FITTING DUE TO FRICTION &
ADDITIONAL HEADS MAY BE NEEDED DUE TO FIELD CONDITIONS. THESE
LOSSES ARE COMPENSATED FOR BY ADDING TEN (10) PERCENT TO THE MFR'S
RATED G.P.M. FOR EACH NOZZLE.
2. LOCATE QUICK COUPLING VALVE &AUTOMATIC CONTROL VALVES IN SHRUB/
GROUNDCOVER AREAS AT POINT OF EASY ACCESS. ENG. TO REVIEW &APPROVE
FINAL LOCATION OF ALL QUICK COUPLERS &AUTOMATIC CONTROL VALVES PRIOR
TO INSTALLATION.
3. HEAD LOCATION MUST BE ADJUSTED IN THE FIELD TO COMPLY W/ EXIST'G SITE
CONDITIONS, PLANT MATERIALS & ANY OTHER ITEMS DEEMED APPROPRIATE BY
THE ENG.
4. EXIST'G STATIC P.S.I. AT IRRIGATION METER IS 58 P.S.I. INFORMATION PROVIDED
BY PERTEET ENG., RECEIVED ON 6/11/03. PRIOR TO INSTALLATION OF IRRIGATION
SYSTEM, CONTRACTOR SHALL FIELD VERIFY EXIST'G P.S.I. NOTIFY ENG. OF ANY
DISCREPANCIES BETWEEN THE DESIGN P.S.I. & EXIST'G P.S.I. PRIOR TO
PROCEEDING W/ WORK.
5. SYSTEM DESIGNED TO 30 P.S.I. (SPRAY HEADS).
6. IRRIGATION CONTRACTOR SHALL COORDINATE IRRIGATION SLEEVING LOCATIONS W/
GENERAL CONTRACTOR.
7. DRAWING IS SCHEMATIC. ACTUAL LOCATIONS MAY VARY DUE TO PLANT
MATERIALS, UTILITIES OR EXIST'G CONDITIONS. CONTRACTOR IS RESPONSIBLE FOR
LOCATING UTILITIES PRIOR TO BEGINNING CONSTRUCTION. CALL 1-800-424-5550
TWO (2) DAYS PRIOR TO DIGGING ON-SITE.
8. ALL IRRIGATION SLEEVING TO BE STAKED IN THE FIELD & LOCATED ON
DIMENSIONED "AS -BUILT" DRAWING TO ALLOW FUTURE LOCATION & USE.
9. AIR BLOW IRRIGATION SYSTEM THROUGH QUICK COUPLERS TO WINTERIZE
IRRIGATION SYSTEM.
10. A MIN. TWO (2) WEEKS PRIOR TO BEGINNING DEMOLITION WORK, CONTRACTOR
SHALL CONTACT MR. TERRY FLATLEY AT THE CITY OF RENTON PARKS DIVISION
(425) 430-6600 TO DOCUMENT THE WORKING ORDER OF EXIST'G IRRIGATION
SYSTEM. CONTRACTOR IS RESPONSIBLE FOR PROTECTING AND/OR RESTORING THE
EXIST'G IRRIGATION SYSTEM DAMAGED BY CONSTRUCTION TO ITS
PRE -CONSTRUCTION CONDITION PER FORCE ACCOUNT ITEM "RESTORATION OF
EXISTING IRRIGATION SYSTEM", SEE SPECS.
11. WHERE PIPE SIZES ARE NOT SHOWN ON THE PLAN, PIPE SHALL BE SIZED TO THE
NEXT LARGEST PIPE SIZE SHOWN UPSTREAM ON THE PLAN.
12. SEE SHEET LS2 FOR ABBREVIATIONS.
w
w
00
u
PAVING & BASE COURSE,
SEE CIVIL DRWG'S
/ - °•'.4 °
-A v'° 4 -
v ° = �d
G c a - ° ° /
°- d„ 0 'J
If III I �� ~•.�-�•�'�•� ' �~���. I III
• •:,. �• ,... :•. I
.,:.�-..�.-:•;...::: III 1
I I I • .- . .. ::0000. ,' ' •. y " I
El I I--_
•, ,•... - .. %J. -
1
�J
=I = ~.'• - '�s ~.�::_ �' CRUSHED SURFACING TOP
�''�' • • = I I COURSE, COMPACT TO 95%
�. - .. � �.•. - .•z • 00«00. •.
• -s • • • - • y• ' - - s MAX. DENSITY
III ..y..-..'
2 PIPE SLEEVE W/ IRRIGATION
IE,1• �= •PIPE & CONTROL WIRES
- :.�-:• III-
. •� ti • ••• z• ' : WIRES FOR VALVES UNDER PIPE.
III=III— III �1=U I F
�'t'iT�— COMPACT SUBGRADE
PIPE SLEEVE
NOT TO SCALE
R-326831.
Q
erteet Inc.
425-252-770011-800-615-9900RENTONJH��
2707 Colby Avenue, suite soo
Everett, Washington 98201
z �: � _ ; -:_.=
HOugh Beck
& Ba1rd Inc
LANDSCAPE ARCHITECTURE
URBANPLANNIN ESIGN
z
i
ZC
1
L
L
MAPLE VALLEY HIGHWAY (SR 169)
CEDAR RIVER PARK ACCESS IMPROVEMENTS
RR SCHED, IRR NOTES, LEGEND & DETAILS
L0
CnE
Z
0
A
J
X'
N
0
o�
ci
0
0
U
r
'a
Cn
C)
C)
v
N
"o
CL
0
0
N
r_
cc
E
0
LO
0
0
N
N
0
C
IRRIGATION SCHEDULE
RAINBIRD 1800 -SAM -PRS -10 SERIES POP-UP SPRAY HEADS 10'
B its 491 RADIUS AT 30 P.S.I. PROVIDE &INSTALL APPROPRIATE ARC NOZZLE TO 4" SLF,VE�
LS5 FIT ANY SHAPE OF PLANTING AREA. 12" POP-UP IN GROUNDCOVER/ �LS5ILS5 - — — - PIPE SLEEVES (CLASS 200 PVC) W/ SIZE -SEE CIVIL
SHRUB AREAS. 4 POP-UP IN LAWN AREAS. DRWG S. SEE SHEET LS6 FOR SLEEVE REQUIREMENTS.
RAINBIRD 1800 -SAM -PRS -12 SERIES POP-UP SPRAY HEADS 12' rc 1 _ 1 /2"
RADIUS AT 30 P.S.I. PROVIDE &INSTALL APPROPRIATE ARC NOZZLE TO LS5 LATERAL LINE (CLASS 200 PVC) W/ SIZE
g s o o
\L15 q 9 0 FIT ANY SHAPE OF PLANTING AREA. 12" POP-UP IN GROUNDCOVER/C 1-1 /2" MAINLINE
SHRUB AREAS. 4" POP-UP IN LAWN AREAS. LS5 - — — — - MAINLINE (SCHED. 40 PVC)
RAINBIRD 1800 -SAM -PRS -15 SERIES POP-UP SPRAY HEADS 15' F m 3/4" MANUAL DRAIN VALVE. CHAMPION 200RS-075 (3/4")
B o 0 o RADIUS AT 30 P.S.I. PROVIDE &INSTALL APPROPRIATE ARC NOZZLE TO LS6 `7 DRAIN VALVE. PROVIDE OWNER W/ TWO (2) VALVE KEYS
LS5 4 G)O FIT ANY SHAPE OF PLANTING AREA. 12 POP-UP IN GROUNDCOVER/
SHRUB AREAS. 4" POP-UP IN LAWN AREAS. QUICK COUPLING VALVES- RAINBIRD 44LRC W/ 44K COUPLER
RAINBIRD 1800-SAM-PRS-I5SST SERIES POP-UP SIDE STRIP SPRAYC D KEY SH -1 HOSE SWIVEL & 2049 LID KEY; PROVIDE OWNER
B � HEAD AT 30 P.S.I. PROVIDE &INSTALL APPROPRIATE ARC NOZZLE TO LS6 W/ TWO (2) SETS OF THE FOLLOWING:
LS5 FIT ANY SHAPE OF PLANTING AREA. 12" POP-UP IN GROUNDCOVER/ COUPLER KEYS
SHRUB AREAS. 4" POP-UP IN LAWN AREAS. G.P.M. HOSE SWIVELS
CIRCUIT N0. /VALVE SIZE LID KEYS
RAINBIRD 1800-SAM-PRS-I5EST SERIES POP-UP END STRIP SPRAY
rB ED FIT
AT 30 P.S.I. PROVIDE &INSTALL APPROPRIATE ARC NOZZLE TOK*A /
\LS5 FIT ANY SHAPE OF PLANTING AREA. 12" POP-UP IN GROUNDCOVER/ S6 � AUTOMATIC CONTROL VALVES W/ SIZE- RAINBIRD PEB SERIES
SHRUB AREAS. 4" POP-UP IN LAWN AREAS. ��
LEGEND
A
LS
DETAIL IDENTIFICATION
SHEET IDENTIFICATION
MANUAL DRAIN VALVE
QUICK COUPLER
BACKFLOW PREVENTER
FLOW SENSOR
MASTER CONTROL VALVE
PVC MAINLINE 1-1 /2" METER -
— SEE CIVIL DRWG'S.
0__
FLOW Tr
DIRECTION ATE VALVE
IRRIGATION POINT OF CONNECTION (P.O.C.)
h NOT TO SCALE
STATE OF
WASHINGTON
REGISTERED
LANDSCAPE ARCHITECT
COLEEN R. HOUGH
CERTIFICATE NO. 318
FINISH GRADE
1" LAWN AREAS OR
2" GROUNDCOVER/
i7LTt=
SHRUB AREAS
POP—UP SPRAY HEAD
ADJUST TO FINISH GRADE
MARLEX 90 MARLEX 90 DEGREE
DEGREE I STREET ELL
STREET ELL �.�ARLEX 90 DEGREE
SCHED. 40 � STREET ELL
PVC BUSHING SCHED. 80 PVC RISER SIZE REQUIRED
AS REQUIRED (g" MIN. LENGTH) (45 DEGREE MAX.
PVC � ANGLE FROM HORIZONTAL POSITION)
LATERAL
LINE TRIPLE SWING JOINT RISER ASSEMBLY
LAWN, SHRUG to GROUNDCOVER HEAD RISER ASSEMBLY POP—UP)
NOT TO SCALE
B OO 1-1/2" HAMMOND GATE VALVE MODEL 667 OR APPROVED EQUAL
LS6
TORO SENTINEL SSAK12PS16NS(1 or 4) 12
LS6 STATION IRRIGATION CONTROLLER
E TORO 220 2" MASTER CONTROL VALVE
LS6 � #220-26-0-9
rE �. DATA INDUSTRIES 1-1/2" FLOW SENSOR #IR220P
�LS6
rB p04 1-1/2" FEBCO 850Y BACKFLOW PREVENTER
LS6 PER CODE REQUIREMENTS
A aM 1-1/2" IRRIGATION WATER METER- SEE SHEET RP2
LS5 (INSTALLED BY CIN)
rA � IRRIGATION POINT OF CONNECTION
LS5
w
w
00
NOTE: �
ALL MAIN AND/OR
LATERAL PIPE UNDER
PAVEMENTS SHALL BE
SLEEVED.
SEE DETAIL �
�L�S5
• • • • i • • • • • • • • • •
• • • • • • • • • • • • • • •
• • • • • • • ! • • a • • a
• • • • • • • • • • • • • • •
...............
...............
...............
0000... 00,00..
...............
0000... 0000...
..
00000
,.
. • . , . .
•
'000
000!0• • • • i • .
.• .0.000.• .•
..........
...............
...............
...............
0000.• 0000...
,0000.. 0000...
,0000 0000
0000 0000
... ••
....
..,
.. .,.,
• 41*
• •
•�•�•
•••••
• •
..• ...
0000 0000
..........
0000.
FINISH GRADE
CONTINUOUS 2" BACKFILL
MATERIAL (SEE SPECS) MATERIAL
AROUND PIPE. TYPICAL BEDDING
EACH PIPE
PVC LATERAL LINE
TRENCH COMPACTED BACKFILL
(EARTH FILL) SEE SPECS.
PVC MAI N LI N E
WIRES FOR VALVES
UNDER PIPE
MPACT SUBGRADE
MAIN AND/OR LATERAL
PIPE TRENCH DETAIL
NOT TO SCALE
IRRIGATION NOTES
fA STPUL
1. THERE IS A LOSS OF PRESSURE IN EACH PIPE FITTING DUE TO FRICTION &
ADDITIONAL HEADS MAY BE NEEDED DUE TO FIELD CONDITIONS. THESE
LOSSES ARE COMPENSATED FOR BY ADDING TEN (10) PERCENT TO THE MFR'S
RATED G.P.M. FOR EACH NOZZLE.
2. LOCATE QUICK COUPLING VALVE &AUTOMATIC CONTROL VALVES IN SHRUB/
GROUNDCOVER AREAS AT POINT OF EASY ACCESS. ENG. TO REVIEW &APPROVE
FINAL LOCATION OF ALL QUICK COUPLERS &AUTOMATIC CONTROL VALVES PRIOR
TO INSTALLATION.
3. HEAD LOCATION MUST BE ADJUSTED IN THE FIELD TO COMPLY W/ EXIST'G SITE
CONDITIONS, PLANT MATERIALS & ANY OTHER ITEMS DEEMED APPROPRIATE BY
THE ENG.
4. EXIST'G STATIC P.S.I. AT IRRIGATION METER IS 58 P.S.I. INFORMATION PROVIDED
BY PERTEET ENG., RECEIVED ON 6/11/03. PRIOR TO INSTALLATION OF IRRIGATION
SYSTEM, CONTRACTOR SHALL FIELD VERIFY EXIST'G P.S.I. NOTIFY ENG. OF ANY
DISCREPANCIES BETWEEN THE DESIGN P.S.I. & EXIST'G P.S.I. PRIOR TO
PROCEEDING W/ WORK.
5. SYSTEM DESIGNED TO 30 P.S.I. (SPRAY HEADS).
6. IRRIGATION CONTRACTOR SHALL COORDINATE IRRIGATION SLEEVING LOCATIONS W/
GENERAL CONTRACTOR.
7. DRAWING IS SCHEMATIC. ACTUAL LOCATIONS MAY VARY DUE TO PLANT
MATERIALS, UTILITIES OR EXIST'G CONDITIONS. CONTRACTOR IS RESPONSIBLE FOR
LOCATING UTILITIES PRIOR TO BEGINNING CONSTRUCTION. CALL 1-800-424-5550
TWO (2) DAYS PRIOR TO DIGGING ON-SITE.
8. ALL IRRIGATION SLEEVING TO BE STAKED IN THE FIELD & LOCATED ON
DIMENSIONED "AS -BUILT" DRAWING TO ALLOW FUTURE LOCATION & USE.
9. AIR BLOW IRRIGATION SYSTEM THROUGH QUICK COUPLERS TO WINTERIZE
IRRIGATION SYSTEM.
10. A MIN. TWO (2) WEEKS PRIOR TO BEGINNING DEMOLITION WORK, CONTRACTOR
SHALL CONTACT MR. TERRY FLATLEY AT THE CITY OF RENTON PARKS DIVISION
(425) 430-6600 TO DOCUMENT THE WORKING ORDER OF EXIST'G IRRIGATION
SYSTEM. CONTRACTOR IS RESPONSIBLE FOR PROTECTING AND/OR RESTORING THE
EXIST'G IRRIGATION SYSTEM DAMAGED BY CONSTRUCTION TO ITS
PRE -CONSTRUCTION CONDITION PER FORCE ACCOUNT ITEM "RESTORATION OF
EXISTING IRRIGATION SYSTEM", SEE SPECS.
11. WHERE PIPE SIZES ARE NOT SHOWN ON THE PLAN, PIPE SHALL BE SIZED TO THE
NEXT LARGEST PIPE SIZE SHOWN UPSTREAM ON THE PLAN.
12. SEE SHEET LS2 FOR ABBREVIATIONS.
w
w
00
u
PAVING & BASE COURSE,
SEE CIVIL DRWG'S
/ - °•'.4 °
-A v'° 4 -
v ° = �d
G c a - ° ° /
°- d„ 0 'J
If III I �� ~•.�-�•�'�•� ' �~���. I III
• •:,. �• ,... :•. I
.,:.�-..�.-:•;...::: III 1
I I I • .- . .. ::0000. ,' ' •. y " I
El I I--_
•, ,•... - .. %J. -
1
�J
=I = ~.'• - '�s ~.�::_ �' CRUSHED SURFACING TOP
�''�' • • = I I COURSE, COMPACT TO 95%
�. - .. � �.•. - .•z • 00«00. •.
• -s • • • - • y• ' - - s MAX. DENSITY
III ..y..-..'
2 PIPE SLEEVE W/ IRRIGATION
IE,1• �= •PIPE & CONTROL WIRES
- :.�-:• III-
. •� ti • ••• z• ' : WIRES FOR VALVES UNDER PIPE.
III=III— III �1=U I F
�'t'iT�— COMPACT SUBGRADE
PIPE SLEEVE
NOT TO SCALE
R-326831.
erteet Inc.
425-252-770011-800-615-9900RENTONJH��
2707 Colby Avenue, suite soo
Everett, Washington 98201
z �: � _ ; -:_.=
HOugh Beck
& Ba1rd Inc
LANDSCAPE ARCHITECTURE
URBANPLANNIN ESIGN
Drown �, �,
Designed � �,�LS5
�,
� e �
Approved"
�
CITY OF RENTON°`°""�"°�
MAPLE VALLEY HIGHWAY (SR 169)
CEDAR RIVER PARK ACCESS IMPROVEMENTS
RR SCHED, IRR NOTES, LEGEND & DETAILS
�,�
�� No.
31 of3�
�'� � �
,�. �� Rte, er nom•