Loading...
HomeMy WebLinkAboutR-373906STORM WATER STANDARD PLAN NOTES qT 1. THESE NOTES SHALL APPEAR ON PROJECTS FOR THE SURFACE WATER UTILITY. O 2. BEFORE ANY CONSTRUCTION OR DEVELOPMENT ACTIVITY OCCURS, A PRE - CONSTRUCTION MEETINGNMUSTBEHELDBETWEENTHECITYOFRENTONPLANREVIEWSECTIONANDTHEAPPLICANT. C) 3. ALL DESIGN AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE RENTON MUNICIPAL CODE RMC), THE LATEST EDITION OF THE STANDARD SPECIFICATIONS FOR ROAD, BRIDGE, AND MUNICICPAL CONSTRUCTION PREPARED BY WSDOT AND THE AMERICAN PUBLIC WORKS ASSOCIATION (APWA), AS AMENDED BY THE CITY OF RENTON PUBLIC WORKS DEPARTMENT. IT SHALL BE THE SOLE RESPONSIBILITY OF THE APPLICANT AND THE PROFESSIONAL CIVIL ENGINEER TO CORRECT ANY ERROR, OMISSION OR VARIATION FROM THE ABOVE REQUIREMENTS FOUND IN THESE PLANS. ALL CORRECTIONS SHALL BE AT NO ADDITIONAL COST TO THE CITY. 4. APPROVAL OF THIS ROAD, GRADING, PARKING AND DRAINAGE PLAN DOES NOT CONSTITUTE AN APPROVAL OF ANY OTHER CONSTRUCTION (e.g. DOMESTIC WATER CONVEYANCE, SEWER CONVEYANCE, GAS, ELECTRICAL, ETC.). tHE SURFACE WATER DRAINAGE SYSTEM SHALL BE Q CONSTRUCTED ACCORDING TO THE APPROVAED PLANS, WHICH ARE ON FILE WITH THE CITY. J ANY DEVIATION FROM THE APPROVED PLANS WILL REQUIRE WRITTEN APPROVAL FROM THE CITY CL OF RENTON PUBLIC WORKS DEPARTMENT, SURFACE WATER UTILITY SECTION. I- 5. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. O 6 MONDAY THROUGH (SITER AYALTERATION) WORKLIMITED TO S HOUYRS FUNLESS OTHERWISE n APPROVED WITH A WRITTEN DECISION BY THE CITY OF RENTON. 7. IT SHALL BE THE APPLICANT /CONTRACTOR'S RESPONSIBILITY TO OBTAIN ALL CONSTRUCTION Z EASEMENTS NECESSARY BEFORE INITIATING OFF -SITE WORK. EASEMENTS REQUIRE CITY REVIEW O AND APPROVAL PRIOR TO CONSTRUCTION. 1'- 8. FRANCHISED UTILITIES OR OTHER INSTALLATIONS THAT ARE NOT SHOWN ON THESE APPROVED PLANS Z SHALL NOT BE CONSTRUCTED UNLESS AN APPROVED SET OF PLANS THAT MEET ALL REQUIREMENTS LU OF CHAPTER 4 OF THE SURFACE WATER DESIGN MANUAL ARE SUBMITTED TO THE CITY OF RENTON. 9. DATUM SHALL BE NAVD 88 UNLESS OTHERWISE APPROVED BY THE CITY OF RENTON. REFERENCE BENCHMARK AND ELEVATIONS ARE NOTES ON THE PLANS. 10. ANY DEWATERING SYSTEM NECESSARY FOR THE CONSTRUCTION OF STORMWATER FACILITIES MUST BE SUBMITTED TO THE CITY OF RENTON FOR REVIEW AND APPROVAL. 11. ALL UTILITY TRENCHES AND ROADWAY SUBGRADE SHALL BE BACKFILLED AND COMPACTED TO 95% (PERCENT) DENSITY, STANDARD PROCTOR. 12. OPEN CUTTING OF EXISTING ROADWAYS FOR NON- FRANCHISED UTILITY OR STORM DRAINAGE WORK IS NOT ALLOWED UNLESS SPECIFICALLY APPROVED BY THE CITY OF RENTON AND NOTED ON THESE APPROVED PLANS. ANY OPEN CUT SHALL BE RESTORED IN ACCORDANCE WITH THE CITY OF RENTON TRENCH RESTORATION STANDARDS. 13. ALL SEDIMENTATION /EROSION FACILITIES MUST BE OPERATION PRIOR TO CLEARING AND BUILDING CONSTRUCTION, AND THEY MUST BE SATISFACTORILY MAINTANED UNTIL CONSTRUCTION IS COMPLETED AND THE POTENTIAL FOR ON -SITE EROSION HAS PASSED. 14. ALL RETENTION /DETENTION FACILITIES MUST BE INSTALLED AND IN OPERATION PRIOR TO OR IN CONJUNCTION WITH ALL CONSTRUCTION ACTIVITY UNLESS OTHERWISE APPROVED BY THE PUBLIC WORKS DEPARTMENT, SURFACE WATER SECTION. 15. ALL PIPES AND APPURTENANCES SHALL BE LAID ON THE PROPERLY PREPARED FOUNDATION IN ACCORDANCE WITH THE CURRENT STATE OF WASHINGTON STANDARD SPECIFICATION OF ROAD AND BRIDGE CONSTRUCTION. THIS SHALL INCLUDE NECESSARY LEVELING OF THE TRENCH BOTTOM OR THE TOP OF THE FOUNDATION MATERIAL, AS WELL AS, PLACEMENT AND COMPACTION OF REQUIRED BEDDING MATERIAL, TO UNIFORM GRADE SO THAT THE ENTIRE LENGTH OF THE PIPE WILL BE SUPPORTED ON A UNIFORMLY DENSE, UNYIELDING BASE. ALL PIPE BEDDING SHALL BE APWA CLASS "C ", WITH THE EXCEPTION OF PVC PIPE. 16. STEEL PIPE SHALL BE ALUMINIZED, OR GALVANIZED WITH ASPHALT TREATMENT #1 OR BETTER INSIDE AND OUTSIDE. 17. ALL DRAINAGE STRUCTURES, SUCH AS CATCH BASINS AND MANHOLES SHALL HAVE SOLID LOCKING LIDS, UNLESS OTHERWISE SHOWN ON THE APPROVED PLANS. ALL DRAINAGE STRUCTURES ASSOCIATED WITH A PERMANENT RETENTION /DETENTION FACILITY SHALL HAVE SOLID LOCKING LIDS. 18. BUILDING AND OTHER STRUCTURES SHALL BE PLACED IN ACCORDANCE WITH TABLE 4.1 EASEMENT WIDTHS AND BUILDING SETBACK LINES. 19. ALL CATCH BASIN GRATES SHALL BE DEPRESSED 0.10 FEET BELOW PAVEMENT LEVEL. 20. ALL DRIVEWAY CULVERTS LOCATED WITHIN COTY OF RENTON RIGHT -OF -WAY SHALL BE OF SUFFICIENT LENGTH TO PROVIDE A MINIMUM 3:1 SLOPE FROM THE EDGE OF THE DRIVEWAY TO THE BOTTOM OF THE DITCH. ROCK FOR EROSION PROTECTION OF ROADWAY DITCHES, WHERE REQUIRED, SHALL BE OF SOUND QUARRY ROCK PLACED TO A DEPTH OF ONE (1) FOTT AND MUST MEET THE FOLLOWING SPECIFICATIONS: 4 - 8 INCH ROCK / 40 - 70% PASSING; 2 - 4 INCH ROCK / 30 - 40% PASSING; AND LESS THAN 2 INCH ROCK / 10 - 20% PASSING. 21. ALL BUILDING DOWNSPOUTS AND FOOTING DRAINS SHALL BE CONNECTED TO THE STORM DRAINAGE SYSTEM, UNLESS APPROVED BY THE CITY PLAN REVIEWER OR SURFACE WATER UTILITY SECTION. AN ACCURATELY DIMENSIONED, CERTIFIED AS -BUILT DRAWING OF THIS DRAINAGE SYSTEM WILL BE SUBMITTED TO THE CITY UPON COMPLETION. 22. DRAINAGE OUTLETS (STUB -OUTS) SHALL BE PROVIDED FOR EACH INDIVIDUAL LOT, EXCEPT FOR THOSE LOTS APPROVED FOR INFILTRATION BY THE CITY. STUB -OUTS SHALL CONFORM TO THE FOLLOWING: A. EACH OUTLET SHALL BE SUTIABLY LOCATED AT THE LOWEST ELEVATION ON THE LOT, SO AS TO SERVICE ALL FUTURE ROOF DOWNSPOUTS AND FOTTING DRAINS, DRVIEWAYS, YARD DRAINS, AND ANY OTHER SURFACE OR SUBSURAFCE DRAINS NECESSARY TO RENDER THE LOTS SUITABLE FOR THIER INTENDED USE. EACH OUTLET SHALL HAVE FREE - FLOWING, POSITIVE DRAINAGE TO AN APPROVED STORMWATER CONVEYANCE SYSTEM OR TO AN APPROVED OUTFALL LOCATION. B. OUTLETS ON EACH LOT SHALL BE LOCATED WITH A FIVE -FOOT HIGH, 2 "x4" STAKE MARKED STORM" OD "DRAIN ". THE STUB -OUT SHALL EXTEND ABOVE SURFACE LEVEL, BE VISIBLE, AND BE SECURED TO THE STAKE. C. PIPE MATERIAL SHALL CONFORM TO UNDERDRAIN SPECIFICATIONS DESCRIBED IN CHAPTER 4 OF THE SURFACE WATER DESIGN MANUAL AND, IF NON- METALLIC, THE PIPE SHALL BE PLACED IN A TRENCH WITH A TRACING WIRE ABOVE OR OTHER ACCEPTABLE DETECTION. D. PRIVATE DRAINAGE EASEMENTS ARE REQUIRED FOR DRAINAGE SYSTEMS DESIGNED TO CONVEY FLOWS THROUGH INDIVIDUAL LOTS. E. THE APPLICANT /CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE LOCATIONS OF ALL STUB -OUT CONVEYANCE LINES WITH RESPECT TO OTHER UTLILITES (e.g. POWER, GAS, TELEPHONE, TELEVISION). OFFE ENGINEERS 13932 SOUTHEAST 159TH PLACE RENTON, WASHINGTON 98058 PHONE: 425 -260 -3412 CONTACT- DARRELL OFFE, P.E. CCTV INSPECTION NOTE a. THE PROJECT DEVELOPER SHALL SUBMIT TO THE CITY THE CCTV INSEPCTION VIDEOS AND WRITTNE REPORTS. THE CCTV INSPECTION SHALL INCLUDE ALL PROJECT STORM DRAIN LINES AND CONNECTING CATCH BASIN AND MANHOLE STRUCTURES THAT WILL BECOME CITY OWNED /MAINTAINED AND ALL PRIVATE 8 INCH DIAMETER OR LARGER DRAIN LINES AND CONNECTING CATCH BASIN AND MANHOLE STRUCTURES. SAID VIDEOS ARE TO BE IN COLOR AND COMPATIBLE WITHTHE CITY'S VIEWING AND RECORDING SYSTEMS. THE CITY WILL ONLY ACCEPT VIDEO SUBMITTALS ON CD OR DVD THAT IS VIEWABLE BY STANDARD VIDEO PLAYER (i.e. mpg VIDEO FILE FORMAT) AND IS COMPATIBLE WITH GRANITE XP. THE VIDEO SHALL REFERENCE EACH PROJECT DRAIN PIPE SEGMENT TO THE UPSTREAM AND DOWNSTREAM CONNECTING STRUCTRURES AS SHOWN (AND IDENTIFIED) ON THE APPROVED PROJECT CONSTRUCTION PLANS. b. THE COSTS INCURRED IN MARKING THE INITIAL CCTV INSPECTION SHALL BE BORNE BY THE PROJECT DEVELOPER. THE DEVELOPER SHALL BEAR ALL COSTS INCURED IN CORRECTING ANY DEFICIENCIES FOUND DURING CCTV INSPECTION, INCLUDING THE COST OF ANY ADDITIONAL CCTV INSPECTION, EXFILTRATION TESTING OR AIR TESTING THAT MAY BE REQUIRED BY THE CITY TO VERIFY THE CORRECTION OF SAID DEFICIENCY. c. THE DEVELOPER SHALL BE RESPONSIBLE FOR ALL COSTS INCURRED IN THE CCTV INSPECTION PERFORMED SOLELY FOR THE BENEFIT OF THE DEVELOPER. 23.5' 5' SIDEWALK "/ 8' LANDSCAPE STRIP) VERT. CURB & GUTTER O DO w Of U Z Of ZIwN11- w w ZIU NOTES: 1. When the driveway width exceeds 15 feet, construct a full 6. Sidewalks at driveway approaches and driveway depth expansion joint (see Standard Plan F -3) with 3/8" joint apron to be 6" min. depth of connate. filler along the driveway centerline. 2. Construct expansion joints parallel with the centerline as required at 15' maximum spacing when driveway widths exceed 30'. See Std. Plan F -3 for sidewalk details. 3. Curb and gutter shown, see the Contract. Plans for the curb design specified. See Std. Plan F -1 for curb details. 4. Avoid placing drainage structures, junction boxes or other obstructions in front of driveway entrances. 5. When driveway approaches are constructed in a commercial zone, the concrete driveway entrance shall be thickened from 6 inches to 10 inches. This includes concrete approach Types 1 -4, sidewalks constructed behind the driveway apron, and the curb and gutter associated with each driveway approach. CEMENT CONCRETE SIDEWALK WHERE SHOWN 23.5' CEM. CONC. CURB & GUTTER SEE NOTE 3) DRIVEWAY ENTRANCE SIDE SLOPE (TYP.) DEPRESSED CURB & GUTTER SEE NOTE 3) SIDEWALK & DRIVEWAY APRON SEE NOTE 6) 16' CONCRETE DRIVEWAY ENTRY W /LANDSCAPE STRIP N.T.S. 8' LANDSCAPE I STRIP 4" MIN. CLASS "B" ASPHALTIC CONCRETE PAVEMENT- 2 -2" LIFTS REQUIRED 6 "MIN. CRUSHED SURFACING TOP COURSE CRUSHED SURFACING BASE COURSE TO BE DETERMINED BY FIELD CONDITIONS BY GEOTECHNICAL ENGINEER. SE 2ND COURT N.T.S. 4C0MMEN4DE_1S,!R APPROVAL By Date: -7/10111/ By: Date: 7.1p By: Date: By: Date: WVArw NOTES: 1. When the driveway width exceeds 15 feet, construct a full 6. Sidewalks at driveway approaches and driveway depth expansion joint (see Standard Plan F -3) with 3/8' pint apron to be 6" min. depth of conrete. filler along the driveway centerline. 2. Construct expansion joints parallel with the centerline as required at 15' maximum spacing when driveway widths exceed 30'. See Std. Plan F -3 for sidewalk details. 3. Curb and gutter shown, see the Contract. Plans for the curb design specified. See Std. Plan F -1 for curb details. Avoid placing drainage structures, junction boxes or other obstructions in front of driveway entrances. S. When driveway approaches are constructed in a commercial zone, the concrete driveway entrance shall be thickened from 6 inches to 10 inches. This includes concrete approach Types 1 -4, sidewalks constructed behind the driveway apron, and the curb and gutter associated with each driveway approach. DRIVEWAY BY OTHERS) a MP 0\ Yy F 6 DSI DEPRESSED CURB & GUTTER SEE NOTE 3) DRIVEWAY APRON SEE NOTE 6) 10' CEM. CONC. CURB & GUTTER SEE NOTE 3) RIVEWAY ENTRANCE DE SLOPE (TYP.) 16' CONCRETE DRIVEWAY ENTRY W/O LANDSCAPE STRIP N.T.S. EX. PAVED SECTION EX. PAVED SECTION NILE AVENUE NE N.T.S. 1 SNOB ERAS PRO 1' FLAT 5' CONCRETE SIDEWALK 7 3 9068' LANDSCAPE STRIP Rw3 w O Zi O z O O t- znO W s UI 22' 1 NOTES: 1. When the driveway width exceeds 15 feet, construct a full 6. Sidewalks at driveway approaches and driveway depth expansion joint (see Standard Plan F -3) with 3/8' pint apron to be 6" min. depth of conrete. filler along the driveway centerline. 2. Construct expansion joints parallel with the centerline as required at 15' maximum spacing when driveway widths exceed 30'. See Std. Plan F -3 for sidewalk details. 3. Curb and gutter shown, see the Contract. Plans for the curb design specified. See Std. Plan F -1 for curb details. Avoid placing drainage structures, junction boxes or other obstructions in front of driveway entrances. S. When driveway approaches are constructed in a commercial zone, the concrete driveway entrance shall be thickened from 6 inches to 10 inches. This includes concrete approach Types 1 -4, sidewalks constructed behind the driveway apron, and the curb and gutter associated with each driveway approach. DRIVEWAY BY OTHERS) a MP 0\ Yy F 6 DSI DEPRESSED CURB & GUTTER SEE NOTE 3) DRIVEWAY APRON SEE NOTE 6) 10' CEM. CONC. CURB & GUTTER SEE NOTE 3) RIVEWAY ENTRANCE DE SLOPE (TYP.) 16' CONCRETE DRIVEWAY ENTRY W/O LANDSCAPE STRIP N.T.S. EX. PAVED SECTION EX. PAVED SECTION NILE AVENUE NE N.T.S. 1 SNOB ERAS PRO 1' FLAT 5' CONCRETE SIDEWALK 7 3 9068' LANDSCAPE STRIP Rw3 GsEODIMENSIONS, INC. ...,` SCALE "" " °'' @ CITY OF RENTON 7 SHORT PLAT y D OFFE, P.E. RENTON JAYMARC HOMES, LLC Z • D.L OFFS. P.E. era rx. DATUM STORM DETAILS AND NOTES 27460 STE V• F41 -. a0ewcH Planning /Building /Public Works Dept. NE 2nd COURT/ NILE AVENUE NE INAL 07/07/2014 N0. REVISION BY DATE APPR """ r 02/10/201, ROOKOIC 6 '15 AIL z n Z m a 0 O ' z 0 OmxO a w 6 n ww c \ I\ 1I N N O O a0 N O O N r0 I O O NI z 0 M rD ro mm O an M 06 r0 m 00 m o 6 0 0M 31 wo N ofN N N N N Na N N M M Ma OUza 440 L,J j............ c..N.440.. ao o wza00Izz a LnC4N I xl oin Wo M ZW ..... L .H. I t M 0 I I 0 NQlat- 0_ n En 430 430 O I II 20LF., 1Z„ D.L ®5 =1.00% n ! PROPOSED_WM- BUY ____ 1! 1 J SEWER....._._......... I.II._ e w 420 420 Phi IE= 421.74 tor< j...........:..... II II o a n V) N M MdM' 00 N sN z wn: a W r,:: IZ cNN N II JL .:....... z cq ..w4rnnoanV . ; CLarn:asM ............ 4 l: m:.........._....;.......... N wat0:.._._....n..:._........... w NE 2nd COURT ROAD PROFILE yU w II : aq7 M N r7 N:Nj m I . NE: d' c0 C DO f II 11 M2. 11 10 32-+00 imr:w1ul w 31 +00 30 00 410 410 mroOERww Oxw N 01 O GsEODIMENSIONS, INC. ...,` SCALE "" " °'' @ CITY OF RENTON 7 SHORT PLAT y D OFFE, P.E. RENTON JAYMARC HOMES, LLC Z • D.L OFFS. P.E. era rx. DATUM STORM DETAILS AND NOTES 27460 STE V• F41 -. a0ewcH Planning /Building /Public Works Dept. NE 2nd COURT/ NILE AVENUE NE INAL 07/07/2014 N0. REVISION BY DATE APPR """ r 02/10/201, ROOKOIC 6 '15 AIL z n Z m a 0 O ' z 0 OmxO a w 6 n ww c \ I\ 1I