Loading...
HomeMy WebLinkAboutT-384707w � a N� W Q cn o z E-4 2P-200 AMP --- W n w ILLUM B cn N o ILLUM C m \ a ILLUM D (SPARE) cn C C n 1"r- im im 77 w 0 Q 77 Q (0 00 10M 00 z z z z 00 Fn 60 W Lj ILLUMINATION GENERAL NOTES 1. ALL WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON UTILITY DEPARTMENT, CURRENT EDITION AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS. A SET OF APPROVED PLANS SHALL BE KEPT ON-SITE AT ALL TIMES DURING CONSTRUCTION. 2. THE HOURS OF WORK IN THE STREET RIGHT-OF-WAY SHALL BE LIMITED TO 8:30 AM TO 3:30 P.M. ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE DEPARTMENT OF PUBLIC WORKS. ALL STREET CLOSURES, PARTIAL OR FULL, SHALL BE APPROVED BY THE DEPARTMENT OF PUBLIC WORKS 24 HOURS IN ADVANCE. THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911 SHALL BE NOTIFIED 24 HOURS IN ADVANCE. 3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. FOR UTILITY LOCATE CALL 48-HOUR LOCATORS, 1-800-424-5555. 4. A PRECONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. (INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON). IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE UTILITY DEPARTMENT 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. 5. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE. 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY CONSTRUCTION. 7. PLANS APPROVED BY THE DIRECTOR OF PUBLIC WORKS SHALL TAKE PRECEDENCE OVER ALL OTHER PLANS. 8. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 9. ALL UTILITY TRENCHES SHALL BE BACKFILLED AND COMPACTED TO 95X MAXIMUM DRY DENSITY MODIFIED PROCTOR. 10. THE CONTRACTOR SHALL PROVIDE MATERIALS SUBMITTALS AND POLE SHOP DRAWINGS TO THE CITY OF RENTON FOR APPROVAL MINIMUM 3 WEEKS PRIOR TO THE DESIRED APPROVAL DATE. SERVICE 1 BREAKER SCHEDULE CIRCUIT BREAKER z MAIN 2P-200 AMP --- ILLUM A 2P-20 AMP 30 AMP 1"r- im im 77 w 0 Q 77 Q (0 00 10M 00 z z z z 00 Fn 60 W Lj ILLUMINATION GENERAL NOTES 1. ALL WORK MATERIALS SHALL BE IN CONFORMANCE WITH THE STANDARDS AND SPECIFICATIONS OF THE CITY OF RENTON UTILITY DEPARTMENT, CURRENT EDITION AND THE LATEST EDITION OF THE WSDOT/APWA STANDARDS AND SPECIFICATIONS. A SET OF APPROVED PLANS SHALL BE KEPT ON-SITE AT ALL TIMES DURING CONSTRUCTION. 2. THE HOURS OF WORK IN THE STREET RIGHT-OF-WAY SHALL BE LIMITED TO 8:30 AM TO 3:30 P.M. ON WEEKDAYS UNLESS OTHERWISE APPROVED IN WRITING BY THE DEPARTMENT OF PUBLIC WORKS. ALL STREET CLOSURES, PARTIAL OR FULL, SHALL BE APPROVED BY THE DEPARTMENT OF PUBLIC WORKS 24 HOURS IN ADVANCE. THE POLICE DEPARTMENT, FIRE DEPARTMENT, AND 911 SHALL BE NOTIFIED 24 HOURS IN ADVANCE. 3. ALL LOCATIONS OF EXISTING UTILITIES SHOWN ARE APPROXIMATE AND IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE TRUE AND CORRECT LOCATION SO AS TO AVOID DAMAGE OR DISTURBANCE. FOR UTILITY LOCATE CALL 48-HOUR LOCATORS, 1-800-424-5555. 4. A PRECONSTRUCTION CONFERENCE AND A 24 HOUR NOTICE SHALL BE REQUIRED PRIOR TO STARTING NEW CONSTRUCTION. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO SECURE ALL NECESSARY PERMITS PRIOR TO STARTING CONSTRUCTION. (INSPECTION WILL BE ACCOMPLISHED BY A REPRESENTATIVE OF THE CITY OF RENTON). IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE UTILITY DEPARTMENT 24 HOURS IN ADVANCE OF BACKFILLING ALL CONSTRUCTION. 5. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE MEANS, METHODS AND SEQUENCES OF CONSTRUCTION AND FOR THE SAFETY OF WORKERS AND OTHERS ON THE CONSTRUCTION SITE. 6. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN STREET USE AND ANY OTHER RELATED PERMITS PRIOR TO ANY CONSTRUCTION. 7. PLANS APPROVED BY THE DIRECTOR OF PUBLIC WORKS SHALL TAKE PRECEDENCE OVER ALL OTHER PLANS. 8. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 9. ALL UTILITY TRENCHES SHALL BE BACKFILLED AND COMPACTED TO 95X MAXIMUM DRY DENSITY MODIFIED PROCTOR. 10. THE CONTRACTOR SHALL PROVIDE MATERIALS SUBMITTALS AND POLE SHOP DRAWINGS TO THE CITY OF RENTON FOR APPROVAL MINIMUM 3 WEEKS PRIOR TO THE DESIRED APPROVAL DATE. SERVICE 1 BREAKER SCHEDULE CIRCUIT BREAKER CONTACTOR MAIN 2P-200 AMP --- ILLUM A 2P-20 AMP 30 AMP ILLUM B 2P-20 AMP 30 AMP ILLUM C 2P-20 AMP 30 AMP ILLUM D (SPARE) 2P-20 AMP 30 AMP SIGNAL 2P-20 AMP 30 AMP SERVICE 2 BREAKER SCHEDULE CIRCUIT BREAKER CONTACTOR MAIN 2P-200 AMP - - - ILLUM A 2P-20 AMP 30 AMP ILLUM B 2P-20 AMP 30 AMP ILLUM C 2P-20 AMP 30 AMP ILLUM D (SPARE) 2P-20 AMP 30 AMP 11. AS PART OF THE DESIGN PROCESS, THE ENGINEER HAS ATTEMPTED TO CONFIRM THAT THERE ARE NOT CONFLICTS WITH OVERHEAD POWER LINES OR SUBSURFACE UTILITIES. HOWEVER, IT IS POSSIBLE FOR THE EXISTING OR PROPOSED CONDITIONS TO CHANGE PRIOR TO IMPLEMENTATION OF THE SCOPE OF WORK IDENTIFIED ON THESE DOCUMENTS. AS THE FIRST ORDER OF BUSINESS. THE CONTRACTOR SHALL POTHOLE EACHP T TO CONFIRMTHAT THERE ARE NOT CONFLICTS WITHUTILITI WAS 61 :� ADDITIONALLY, THE CONTRACTOR SHALL CONFIRM THAT THERE IS A MINIMUM 10 -FT CLEARANCE PROVIDED BETWEEN OVERHEAD ILLUMINATION WIRING DIAGRAM POWER LINES AND THE PROPOSED LUMINAIRE POLES PRIOR TO POLE PLACEMENT. ADDITIONAL CLEARANCE MAY BE REQUIRED AS 0,�: , DIRECTED BY THE UTILITY. THE CONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY IF A CONFLICT IS DISCOVERED. 12. CONTRACTOR SHALL RESTORE ALL GROUNDS DISTURBED BY CONDUIT AND ILLUMINATION SYSTEM INSTALLATION, INCLUDING BUT NOT LI MI TED TO: LANDSCAPING, IRRIGATION, CONCRETE SIDEWALKS, ETC. 13. EXISTING ILLUMINATION SYSTEM SHALL REMAIN OPERATIONAL UNTIL SUCH TIME THAT NEW ILLUMINATION SYSTEM IS OPERATIONAL. MAXIMUM DOWN TIME FOR SWITCHOVER TO THE NEW SYSTEM SHALL BE 24 HOURS. ILLUMINATION CONSTRUCTION NOTES OINSTALL FOUNDATION, POLE, TWO LUMINAIRES, AND JUNCTION BOX PER ILLUMINATION POLE SCHEDULE, SHEET IL 1.06, AND PER CITY OF RENTON STANDARD PLANS 117.1., 117.3,9 119t 120, 121, & J013. O INSTALL FOUNDATION, POLE, LUMINAIRE, AND JUNCTION BOX PER ILLUMINATION POLE SCHEDULE, SHEET IL 1.06, AND PER CITY OF RENTON STANDARD PLANS 117.2 , 1 17.3, 119, 120, & 121 & JO 13. OINSTALL FOUNDATION AND JUNCTION BOX PER ILLUMINATION POLE SCHEDULE, SHEET IL 1.06, AND PER CITY OF RENTON STANDARD PLANS 115, 119, 120, 121 & J013 AND WSDOT STANDARD PLAN J-28.30. RELOCATE EXISTING ILLUMINATION POLE TO NEW FOUNDATION. CONTRACTOR SHALL VERIFY BOLT PATTER PRIOR TO POURING FOUNDATION. OINSTALL FOUNDATION, POLE, LUMINAIRE, AND JUNCTION BOX PER ILLUMINATION POLE SCHEDULE, SHEET IL 1.06, AND PER CITY OF RENTON STANDARD PLANS 1 17.1, 1 17.3, 119, 120, 121, & J013. OPOWER SOURCE CONNECTION POINT UNKNOWN AT THE TIME OF PLAN PREPARATION. CONTRACTOR SHALL ASSUME APPROXIMATELY 500 FEET OF TRENCHING TO POWER SOURCE. CONTRACTOR SHALL COORDINATE WITH PSE FOR SPECIFIC REQUIREMENTS. PSE TO PROVIDE 120/240 VOLT SINGLE PHASE POWER SOURCE. CONTRACTOR SHALL COORDINATE WITH PSE'S TRANSPORTATION'S MAINT. < ASST. MANAGER (ERIC CUTSHALL) AT 425-430-7423 FOR SERVICE CABINET ELECTRICAL HOOK-UP, SHALL PREPARE/SUBMIT ALL APPLICABLE PERMITS,_ AND SHALL PAY ALL ASSOCIATED FEES. J OCONSTRUCT STREET LIGHT CONTACTOR FOUNDATION PER CITY OF RENTON STD PLANS 126.1 AND 126.2. FURNISH AND INSTALL SERVICE CABINET PER CITY OF RENTON STD PLAN 122.1. LOCATION AND ORIENTATION OF FOUNDATION AND CABINET SHALL BE VERIFIED BY CITY OF RENTON INSPECTOR PRIOR TO INSTALLATION OF CONDUITS. OCONTRACTOR SHALL FURNISH AND INSTALL ALL CONDUIT AND CONDUCTORS TO THE POWER SOURCE. POWER SOURCE FOR NEW SERVICE CABINET SHALL BE FROM THE SAME SOURCE THE EXISTING/REMOVED SERVICE CABINET DRAWS POWER FROM. CONTRACTOR SHALL LEAVE SUFFICIENT SLACK IN CONDUCTOR FOR FINAL CONNECTION. CONTRACTOR SHALL COORDINATE WITH PSE FOR SERVICE CABINET ELECTRICAL HOOK-UP, SHALL PREPARE/SUBMIT ALL APPLICABLE PERMITS, AND SHALL PAY ALL ASSOCIATED FEES. 8O REMOVE EXISTING SERVICE CABINET AND FOUNDATION. FILL AND COMPACT VOID. OREMOVE EXISTING TYPE Ill SIGNAL STANDARD. REMOVE EXISTING FOUNDATION TO A MINIMUM OF 24" BELOW FINISH GRADE. RETURN SALVAGED POLE TO THE CITY OF RENTON. 10 SPLICE NEW ILLUMINATION CONDUCTORS TO EXISTING ILLUMINATION CONDUCTORS IN EXISTING JUNCTION BOX PER CITY OF RENTON STANDARD PLAN J013. INTERCEPT AND EXTEND EXISTING CONDUIT TO NEW JUNCTION BOX. SPLICE NEW ILLUMINATION CONDUCTORS TO EXISTING ILLUMINATION CONDUCTORS PER CITY OF RENTON STANDARD PUN J013. 12 REMOVE EXISTING JUNCTION BOX. REPLACE WITH NEW TRAFFIC BEARING JUNCTION BOX TYPE 4 PER WSDOT STANDARD PUN J-40.20-02. JUNCTION BOX SHALL HAVE SKID RESISTANT LID. 13 RELOCATE EXISTING STREET LIGHT POLE, ARM AND LUMINAIRE TO NEW FOUNDATION AT LOCATION SHOWN. REMOVE EXISTING FOUNDATION TO A MINIMUM OF 24" BELOW FINISH GRADE. FILL AND COMPACT VOID. 14 RELOCATE EXISTING STREET LIGHT POLE, ARM AND LUMINAIRE TO NEW FOUNDATION ON SW 43RD STREET (SEE POLE ID 'RB', STA. 29+51.5, 34.0' RT). REMOVE FOUNDATION. FILL AND COMPACT VOID. SEE ILLUMINATION CONSTRUCTION NOTE 19. 15 REMOVE EXISTING JUNCTION BOX. FILL AND COMPACT VOID. � 6 REMOVE EXISTING JUNCTION BOX AND CONCRETE PAD. FILL AND COMPACT VOIDS. REMOVE EXISTING CONDUCTORS. ABANDON EXISTING CONDUIT. 18 EXISTING STREET LIGHT POLE TO REMAIN. PROTECT DURING CONSTRUCTION. 19 RELOCATED FROM LIND AVE SW. SEE ILLUMINATION CONSTRUCTION NOTE 14. 20 EXISTING SERVICE CABINET TO REMAIN. PROTECT DURING CONSTRUCTION. DAMM CITY OF RENTON, NAVD 88 Approved by: ®ENCHk%W-' CITY OF RENTON CONTROL Approved by: POINT NO. 1864 WAS HELD Approved by: FOR ELEVATION, BEING 19.488 FEET (NAVD88) Approved by: CIRCUIT CONTINUES ON SW 41 ST ST SW 41ST ST TO EX SERVICE CABINET AT SE CORNER OF SW 41 ST ST AND LIND A VE SW 1 �1 RA IRB CITY STANDAMS DateAAMI Date Date Date CITY OF RENTON E>EPAR'7"wAENT OF r1.JiL_IC W017KS FfIONTA LLU~TM FLAN WTES AND DETAILS RVTENW CEA REDEVELOPMENT RENTON, WA. Transportation Engineering NorthWest TDR Transportation Planning I Design I Traffic Impact & Operations DA -M 08/10/2015 KA NO. U 1 500 1 266 pRVM TDR OM�i01� GMD FILD F*Aw 7 orr�c oR oft warns a1�lT cr io T� �? D • ISM Uwr4LK f UtvtLUrtrc: re 43� IKEA PROPERTY INC NER r 420 ALAN WOOD ROAD �� CONSHOHOCKEN, PA 19428 .•..•••••••..; WAS 61 :� CONTACT: DWIGHT E. SLATON M M CONSTRUCTION MANAGER • '`� D' W P: (610) 834-0180; C: 303-549-4623 0,�: , 2 5 : �� E: QWW T. SLAjQh j%U. C0M FKGNtFR: FS; :�.c/ TEQ;.• G� S/. • TRAWSPORTATION ENGINEERING NORTHWEST 11400 SE 8TH STREET, SUITE 200 BELLEVUE, WA 98004 41 .41;f6y CONTACT: GLEN Du9REUIL P: (425) 250-0582; C: (206) 295-6776 E: CITY OF RENTON E>EPAR'7"wAENT OF r1.JiL_IC W017KS FfIONTA LLU~TM FLAN WTES AND DETAILS RVTENW CEA REDEVELOPMENT RENTON, WA. Transportation Engineering NorthWest TDR Transportation Planning I Design I Traffic Impact & Operations DA -M 08/10/2015 KA NO. U 1 500 1 266 pRVM TDR OM�i01� GMD FILD F*Aw 7 orr�c oR oft warns a1�lT cr io T� �? D • ISM °gym re 43� Z C bid ob i Nz m M M 9 1 m E n 8 oho 52 o �+ o Cnt7l bid ob 1 a 1 m E n 8 oho 52 o Cnt7l CD Ln 1 m w y E n 8 oho 52