HomeMy WebLinkAboutS-362517D
.,
c
0
n -
m
z
O
m
m
' 00 ••,
>
VAULT LID MARKED
o
0 2" UNISTRUT. SECURE
EXPLOSION PROOF JUNCTION
CONTROLWITH WELDBEAD.
1— — — — — — — — — — — — — -, UNISTRUT TO HANDHOLE
WALLS.
PLASTIC TUBE COUPLING.
BOX (TYPICAL).
1 0 o I
I
SIZE AS NECESSARY.
ar
TO MOTOR CONTROL CENTER/RTU
TO WETWELL
I FLEXIBLE CORD
s
o
i 0 0 I Z CONNECTOR (TYPICAL)
BUBBLER TUBE FOR BELLOWS
JACKETED CABLE FOR LEVEL TRANSDUCER
w
GRS CONDUIT (TYPICAL).
I I 2" PVC CABLE SLEEVE
I
J�j�
1�
�
. 4. °
, 12" MAX, TYP.
AN. SIZED PER PL
I
( (TYPICAL)
I I
(TYPICAL)
SEAL TYPICAL
a
J
CONDUIT TO PUMP -�--
I ---- TO WETWELL.
o
0
:4
:;;•
STARTER
I (TYPICAL)
— — — — — — — — —
— —
CONDUIT (TYPICAL).
�;'
°:.
PUMP MOTOR CABLE, FLOAT
SEAL TYPICAL .
( }
I
I o 0 1
I - -
I
I
1
( FLEXIBLE CORD CONNECTOR
I
?O00
o 0
z
g cn
CONTRACTOR SHALL GROUT
°
a
` ' CABLE, OR LEVEL TRANSMITTER
_
I - I WIRE NUT ENDS TOGETHER
0 0 I
SEAL (TYPICAL) 1
I 0
I (TYPICAL)
FILL AROUND CONDUIT WITH
4.
:: !! . CABLE TYPICAL )
i AND SEAL WATER TIGHT
I
I
�
NON -SHRINK GROUT FOR WATER
TIGHTNESS.
04 .
o :4
� � �
:. 2" UNISTRUT (TYPICAL).
I FOR TERMINATING CABLE
i
1 0 0 TO FIELD WIRE (TYPICAL).
GRS CONDUIT (TYPICAL}. I
SIZE PER PLAN. �' - -
1 2 PVC CABLE SLEEVE (TYPICAL)
1
�'
ZC
W c�i W N
= Q04
06
I 1 BELL END OF CONDUIT
CONDUIT TO CONTROL PANEL -- _ =
1
TO WETWELL FOR LEVEL
t - --- TRANSDUCER
m N
(TYPICAL)
I
4
SET ABLELEEVE AT
C S
ONDUCT TO PUMP STARTER r--
I
I
I
I
I
1 /4"x4N4" STEEL PLATE. WELD
UNISTRUT TO PLATE AND MOUNT TO
WALLS OF HANDHOLE USING (4) 3/8"
+
,; :
. °.a
:®4.: BOTTOM OF VAULT AND
SLOPE TOWARDS WET
WELL.
EXPLOSION PROOF JUNCTION
I
,, COIL MINIMUM OF 5 FEET OF
I 1 EXCESS CORD.
( I
EXPLOSION PROOF JUNCTION BOX I o 0
WITH COVER (TYPICAL). SECURE i
1 g
o6
1
STAINLESS STEEL CONCRETE
°
4
BOX WITH COVER. 0-Z/GEDNEY
1 0 0 I
TO UNISTRUT USING 1/4" I o o
I PLACE SMALL BAG OF
O
ANCHORS.
4
:°:.: .... :...... .. :: ;... :...
� -° r �. a :`. ; :'
a': : b °° °-(TYP)i
GUJC-100 BOX OR EQUAL
(TYPICAL). SECURE JUNCTION
I PLACE SMALL BAG OF
( (
STAINLESS STEEL BOLTS
I
O-ZIGEDNEY GUJC-100 BOX OR
I DESICCANT (TYP)
r,
y:
BOX TO UNISTRUT USING 1/4"
STAINLESS STEEL BOLTS.
I 0 0 DESICCANT I
I — (
------- ----------- ELECTRICAL HANDHOLE,
0 0
EQUAL FOR LEVEL TRANSDUCER. I
I
I
I BELL END OF CONDUIT (TYPICAL)
I
Q
cn
iE�
SLOPE TO DRAIN
o
o UTILITY VAULT MODEL
233 -LA OR EQUAL
CONDUIT TO CONTROL PANEL --- �
_� TO WETWELL
I FOR FLOATS
[r�,y
mi
Q
0-Z/GEDNEY GUJX-100 BOX OR
I
COIL MINIMUM
w
SPLICE HANDHOLE
ELEVATION
06
MOTOR
SPLICE HANDHOLE PLAN DETAIL A
EQUAL FOR FLOATS.
1 0 oI
I OF5FEET OF
EXCESS CORD.
Q
NOT TO SCALE 03
I
~j
NOT TO SCALE
HUB FOR ADDITIONAL FLOATS.
WIRE NUT ENDS TOGETHER AND
�
D
E
FLOATS NOT SHOWN FOR CLARITY.0 0
I
I
( SEAL WATERTIGHT FOR
Q
— — — —
0
— — — — I TERMINATING CABLE TO FIELD
o WIRE (TYPICAL).
�
ELECTRICAL HANDHOLE UTILITY
SECURE 2„ UNISTRUT TO HANDHOLE WALLS.
U
V
VAULT MODEL 233 -LA OR EQUAL
w
CADWELD TYPE TA.
FLOAT/LEVEL TRANSMITTER SPLICE HANDHOLE PLAN
E
ui
CADWELD CABLE TO03
CADWELD TYPE RR.
NOT TO SCALE
CABLE TEE CONNECTION.
CADWELD END CABLE TOCOPPER
UPPER REBAR CONNECTION.
CONDUCTOR
CONCRETE COVER.0IIIII
o
GRADE
REBAR
tel,
COPPER CONDUCTOR
0 ♦
CONCRETE GROUND ROD PROTECTOR 13”
DEPTH X 12" HEIGHT WITH COVER. PIPE
INC. #12R -12A & 12R -12T, OR EQUAL.
GROUND TEE DETAILGROUNDm REBAR DETAIL
NOT TO SCALE
NOT TO SCALE
5/8"x8' LONG COPPER GROUND ROD.
NATIVE MATERIAL COMPACTED TO RED ELECTRICAL WARNING
95% PER ASTM D1557 OR AS TAPE CENTERED OVER RESTORE SURFACE TO EXISTING
co
o
8'-0"
REQUIRED PER PLAN EACH CONDUIT IN TRENCH
N r
CONDITION OR BETTER PER PLANS
i (TYP)
CADWELD TYPE XA.
iw t
uu
CADWELD TYPE GR
CADWELD CABLE TO CABLE
o ■�.
0
� cv
CADWELD CABLE TO
CROSS CONNECTION.
cLli
J
V�
COPPER CONDUCTOR9"
GROUND ROD CONNECTION.
z r.
v
o
�
Z
�
�z
z � o
cv 6„ "
COVER OVER 3
a
z
�
W
5/8" X 8' COPPER GROUND
HIGHEST CONDUIT IN � � "
M
9
�
ROD.
COPPER CONDUCTOR
TRENCH
SAND BEDDING MATERIAL PER
(TYPICAL)
3"
WSDOT SPECIFICATION 9-03.13
Lo
GROUND ROD DETAIL
MINIMUM DEPTH BELOW
ELECTRICAL CONDUIT NUMBER AND
SIZE VARY AS PER SITE PLAN. MAINTAIN
N
N
='
0
a
BOTTOM OF DEEPEST CONDUIT
W
GROUND TEE DETAIL
GROUND CROSS DETAIL
NOT TO SCALE
INSTALLED IN TRENCH
12" SPACING BETWEEN TELEMETRY
CONDUITS AND OTHER CONDUITS.
o
W
NOT TO SCALE
NOT TO SCALE
lYPICAL ELECTRICAL T
DETAIL
�
i
W
NOT TO SCALE
NOTE: BURY DEPTH OF CONDUIT AND HORIZONTAL SPACING SHALL
W
4
z
REVISED TO CONFORM
BE CONFIRMED WITH SERVING UTILITY BEFORE CONSTRUCTION.
w
x
SCALE: SHOWN
GROUNDING
CONNECTION DETAILS
TO CONSTRUCTION RECORDS
t
NOT TO SCALE
'" >i_J*e4_,m, vhpo
o" 1"
7
RH2 ENGINEERING III DA
DRAWING IS FULL
BAR MEASURES
SCALE WHEN
2"
DWG N4.:
SH NO.:
E06
19
21
D
.,
c
0
n -
m
z
m
m
>
n
0
1�