HomeMy WebLinkAboutR-386502c h ,R- - Z
c �
SYMBOL LEGEND
d
ABBREVIATIONS
GENERAL NOTES
DRAWN ON THIS SHEET
r
PERIMETER ROAD ASPHALT REPAIR
&
AND
JT
JOINT
1)
THE SCOPE OF WORK INCLUDES ALL WORK WITHIN THE CLOUD(S) MARKED WITH THE REVISION (REV) LETTER WHICH MATCHES THE ONE
cn
@
AT
INDICATED IN THE LOWER RIGHT CORNER OF THE SHEET OR THE LATEST REV LETTER IN THE REVISION SECTION OF THE TITLE BLOCK. IF
4^X
BUILDING, WALL SECTIONS
A&E
ARCHITECT AND ENGINEER
K
KIPS)
THERE IS NO CLOUD ON THE SHEET, THE ENTIRE SHEET IS IN THE SCOPE OF WORK, UNLESS IT'S A DETAIL SHEET. A DETAIL REFERENCED
#X ox #
AND DETAIL REFERENCES
AIRFIELD ASPHALT REPAIR
AB
ANCHOR BOLT
KO
KNOCK OUT
WITHIN A CLOUD IS INCLUDED IN THE SCOPE OF WORK EVEN WHEN THE ACTUAL DETAIL DRAWING IS NOT CLOUDED ON THE .DETAIL SHEET.
ADJ
ADJACENT
L
LENGTH
LEGENDS AND GENERAL NOTES ALWAYS APPLY WHETHER CLOUDED OR NOT. CONSTRUCTION NOTES PERTAINING TO THIS JOB WILL BE CLOUDI=D
DRAWN ON THIS SHEET
AFF
ABOVE FINISHED FLOOR
LAG BOLT
AND MARKED WITH THE MATCHING REV LETTER UNLESS ON A SHEET WHERE THERE ARE NO CLOUDS AT ALL, THEN ALL NOTES APPLY. FLAG
CONCRETE APRON REPAIRLB
AGG
AGGREGATE
LEN
LENGTH
NOTES POINT TO SPECIFIC INSTANCES OF THE CONSTRUCTION; NUMBERED NOTES APPLY TO THE ENTIRE CONSTRUCTION AREA.
REFERENCED FROM THIS SHEET
AL
ALUMINUM
�X
CONCRETE
ALT
ALTERNATE
LF
LL
LINEAL FEET
LIVE LOAD
2)
PROVIDE MEANS PURCHASE AND INSTALL TO COMPLETE WORKING ORDER, INTEGRATED WITH ADJACENT BUILDING ELEMENTS AND FINISH ITEMS, IN
� I
REFERENCE TO DETAIL
ANCH
ANCHOR, ANCHORAGE
LWR
LOWER
FULL COMPLIANCE WITH DESIGN INTENT. INSTALL MEANS, OBTAIN ITEM(S) TO BE INSTALLED FROM OWNER AT LOCATION AS DIRECTED BY
#X # X # ��
PLAN
APA
AMERICAN PLYWOOD ASSOC.
CONSTRUCTION MANAGER, AND INSTALL IN SAME MANNER AND COMPLIANCE AS IF PURCHASED.
----
CONCRETE CURB &GUTTER REPAIR
APPD
APPROVED
MATL
MATERIAL
APPROX
APPROXIMATE
MAX
MAXIMUM
3)
KEEP AREAS UNDER CONSTRUCTION CLEAR OF DIRT AND DEBRIS CAUSED BY DEMOLITION AND STORE CONSTRUCTION MATERIALS AND EQUIPMENT
X DETAIL DESIGNATION
ASTM
AMERICAN SOCIETY
MB
MACHINE BOLT
IN AREAS DESIGNATED BY THE CONSTRUCTION MANAGER.
WALL TYPE: EXISTING
OF TESTING MATERIALS
MBR
MEMBER
XXXX
DRAWN ON SHEET
NUMBER
BTWN
BETWEEN
MET
MFR
METAL
MANUFACTURE(R)
4)
VERIFY DIMENSIONS &CONDITIONS SHOWN ON THE DRAWINGS AND ON SITE AND ACCEPT RESPONSIBILITY FOR THE JOINING OF WORK AMONGST
BLAST FENCEBLDG
BUILDING
MIN
MINIMUM
VARIOUS TRADES AND TO EXISTING CONDITIONS. BRING DISCREPA CIES ON DRAWINGS OR IN SPECIFICATIONS TO THE ATTENTION OF THE
SECTION/DETAIL DESIGNATION
X
BLKG
BOT
BLOCKING
BOTTOM
MISC
MISCELLANEOUS
CONSTRUCTION MANAGER IMMEDIATELY UPON DISCOVERY. i
MT
MOUNT(ED) (ING)
XXXXX XXXXX DRAWN ON SHEET
NUMBER
C
CHANNEL
MTL
METAL
5)
STOP WORK IN AREA WHERE ASBESTOS &/OR LEAD PAINT IS SUSPECTED. IMMEDIATELY REPORT DISCOVERY TO CONSTRUCTION MANAGER FOR
CB
CATCH BASIN
TESTING AND POSSIBLE REMEDIAL ACTIVITY BY BOEING.
CC
CENTER TO CENTER
N
NORTH (COORDINATE)
REFERENCED ON SHEET NUMBER
CEM
CEMENT
NF
NEAR FACE
6)
ENSURE ALL WORK CONFORMS TO APPLICABLE CODES AND REGULP,TIONS.
CF
CUBIC FEET
NIC
NOT IN CONTRACT
N NORTH
ARROW
CJ
CONTROL JOINT
NO.
NUMBER
7)
COMPLY WITH THE CONSTRUCTION MANAGER (OR PROJECT ADMINISTRATOR) FOR CONSTRUCTION AREA AND SECURITY REGULATIONS.
CL
CENTER LINE
NOM
NOMINAL
CLR
CLEARANCE)
NTS
NOT TO SCALE
8)
PROVIDE ALL REPETITIVE FEATURES NOT FULLY SHOWN ON THE DRAWINGS AS IF DRAWN IN FULL SO THAT THE WORK COMPLETELY MEETS THE.
COL
COLUMN
OVERALL
INTENT OF THE CONTRACT DOCUMENTS.
------ -------------
CONSTRUCTION ABOVE OR BELOW,OA
COMP
COMPRESSED
( ) (ION)
O/C
ON CENTER
BEYOND OR BEHIND
CONC
CONCRETE
OD
OUTSIDE DIAMETER
g)
DIMENSIONS ON DRAWINGS ARE TAKEN TO THE FACE OF CONCRETE OR MASONRY WALLS, METAL STUDS, AND TO THE CENTERLINE OF COLUM�11S,
CONN
CONNECTION
OF
OUTSIDE FACE
UNLESS NOTED OTHERWISE. DIMENSIONS ARE NOT SHOWN IN CONDITIONS WHERE NEW CONSTRUCTION IS TO ALIGN WITH EXISTING FACE OR
FLAG NOTE FOR SPECIFIC
CONST
CONSTRUCTION
OPG
OPENING
CENTERLINE.
CONSTRUCTION DIRECTION
CONT
CONTINUOUS, CONTINUE
OPP
OPPOSITE
CONTR
CONTRACT(OR)
10)
DOOR OPENINGS ARE 6" FROM ADJACENT WALLS OR CENTERED IN ROOM, UNLESS DIMENSIONED OTHERWISE.
GENERAL "BOAT" NOTE FOR SPECIFIC
CTSK
CY
COUNTERSUNK
CUBIC YARD(S)
P
PAR
PAINT
PARALLEL
11)
PARTITIONS SHALL RUN FULL HEIGHT, FROM FLOOR TO STRUCTURE ABOVE, UNLESS SHOWN OR NOTED OTHERWISE.
OR EXIST. INFORMATION
PCC
PRECAST CONCRETE
0
DBL
DIAMETER
DOUBLE
PCF
POUNDS PER CUBIC FOOT
12)
PATCH AND PAINT ALL EXISTING SURFACES DAMAGED DURING REMOVAL AND CONSTRUCTION (PAINT ENTIRE CONTINUOUS SURFACE).
—x x x—
CHAINLINK FENCE
PERF
PERFORATE(D)
DEMOL
DEP
DEMOLISH, DEMOLITION
DEPRESSED
PERIM
PERIMETER
13)
PRIOR TO INSTALLING FINISHES, INSPECT, PATCH AND REPAIR ALL SUBSURFACE CONDITIONS TO PROVIDE A SMOOTH, FLAT FINISH THROUGHOUT.
— — — — —
AIRCRAFT CLEARANCE LINES
DIA
DIAMETER
PL
PLYWD
PLATE
PLYWOOD
DIAG
DIAGONAL
PNL
PANEL
14)
PLANS WHICH APPEAR AS BACKGROUNDS ON MECHANICAL AND ELECTRICAL DRAWINGS, ARE ONLY FOR THE PURPOSE OF ILLUSTRATING GENERAL
CMP SLOT DRAIN
DIM
DIMENSION
PREST
PRESTRESS(ED)
PLAN CONFIGURATION. SUCH BACKGROUNDS SHALL NOT BE USED FOR PORTIONS OF THE WORK OTHER THAN THAT RELATED TO THE SPECIFIC
DL
DEAD LOAD
PRF
PREFORMED
SYSTEMS SHOWN ON EACH SHEET AS INDICATED IN THE DRAWING SUB -TITLE.
s,rs
STORM SEWER
DN
DOWN
PSF
POUNDS PER SQUARE FOOT
DS
DOWNSPOUT
PSI
POUNDS PER SQUARE INCH
15)
TAKE RESPONSIBILITY FOR COORDINATION OF ARCHITECTURAL, MECHANICAL, AND ELECTRICAL WORK. REFER TO ARCHITECTURAL, MECHANICAL END
F
FUEL SPILL LINE, DIP
DWG
DRAWING
PT
POINT
ELECTRICAL DRAWINGS IN DETAIL FOR COORDINATION OF SPECIFIC REQUIREMENTS.
■
TYPE 1 CATCH BASIN,
E
EAST (COORDINATE)
PVC
POLYVINYL CHLORIDE
16)
WHERE COLUMNS OCCUR IN AREAS SCHEDULED TO BE FINISHED, THE COLUMNS SHALL BE ENCLOSED PER DETAILS AND RECEIVE SAME FINISH
SOLID LID
EA
EACH
R
RADIUS (CURVATURE
AS ROOM UNLESS NOTED OTHERWISE.
EB
EXPANSION BOLT
R
RISER
�
TYPE 1 CATCH BASIN, GRATE
EF
EACH FACE
REF
REFERENCE, REFER TO
17)
WHERE FLUSH MOUNTED ITEMS OCCUR AT WALLS OF FIRE RESISTIVE CONSTRUCTION, ENSURE THAT CUTOUTS, REPAIRS &PATCHES DO NOT
EJ
EXPANSION JOINT
REINF
REINFORCED) (ING)
COMPROMISE THE RATED CONSTRUCTION OF THE WALL ASSEMBLY.
TYPE 2 CATCH BASIN, SOLID LID
EL
ELEVATION
REQ
REQUIRED) (ING)
ELEV
ELEVATION
REV
REVISION(S), REVISED
18)
VERIFY LOCATION OF ALL UTILITIES PRIOR TO WORK BELOW INTERIOR FINISH FLOOR OR EXTERIOR PAVING.
O
TYPE 2 CATCH BASIN, GRATE
EQ
EQUAL
RH
RIGHT HAND
EW
EXIST
EACH WAY
RO
ROUGH OPENING
19)
OBTAIN &POST REQUIRED CONSTRUCTION PERMITS FROM THE AUTHORITY HAVING JURISDICITON PRIOR TO COMMENCING CONSTRUCTION.
EXISTING
TOFA (E)
TAXIWAY OBJECT FREE AREA (EXISTING)
EXP
EXPOSED
S
SOUTH (COORDINATE)
EXT
EXTERIOR
SECT
SECTION
20)
PROVIDE MANUFACTURER'S INSTALLATION INSTRUCTIONS TO THE BOEING PROJECT CONSTRUCTION MANAGER WHENEVER SUCH INSTRUCTIONS ARI.
TOFA (U)
TAXIWAY OBJECT FREE AREA (ULTIMATE)
SF
SQUARE FEET
REFERENCED IN THE CONSTRUCTION NOTES.
FAS
FASTEN(ER)
SHT
SHEET
FF
FACTORY FINISH
SIM
SIMILAR
21)
COORDINATE WITH THE BOEING PROJECT CONSTRUCTION MANAGER FOR STAGING AREAS WHERE CONTRACTOR MAY STORE SALVAGED MATERIALS TO
ROFA (U)
RUNWAY OBJECT FREE AREA (ULTIMATE)
FF
FINISHED FLOOR
SQ
SQUARE
BE REUSED IN LATER PARTS OF THIS PROJECT AND WHERE MATERIALS TO BE STAGED BY BOEING ARE TO BE LOCATED.
FGR
FINISH GRADE
SST
STAINLESS STEEL
AIRPORT LEASE LINE
FH
FIRE HYDRANT
ST
STRUCTURAL TEE
22)
SYMBOLS SHOWN ON MATERIALS LIST ARE NOT ALWAYS USED IN DRAWINGS. VERIFY EXISTING MATERIAL AND SEE CONSTRUCTION NOTES FOR
FIN
FINISH(ED)
STD
STANDARD
MATERIAL CALLOUTS.
A
COMPRESSED AIR
FND
FOUNDATION
STL
STEEL
FOC
FACE OF CONCRETE
STIR
STRUCTURAL
23)
ARCHITECTURAL REFLECTED CEILING PLANS INDICATE THE FINAL LOCATIONS OF MECHANICAL AND ELECTRICAL COMPONENTS. SEE THE REFLECTED
ss
SANITARY SEWER
FOF
FACE OF FINISH
SYM
SYMMETRY,SYMMETRICAL
CEILING PLANS FOR LOCATIONS OF ALL ITEMS IN CEILING; SEE DISCIPLINE SHEETS FOR ALL INFORMATION ABOUT THE MECHANICAL AND
FDIC
FURNISHED BY OWNER/
SYS
SYSTEM
ELECTRICAL COMPONENTS INDICATED ON ARCHITECTURAL REFLECTED CEILING PLANS.
INSTALLED BY CONTRACTOR
SCO
CLEANOUT
FO
FINISHED OPENING
T&B
TOP AND BOTTOM
24)
PROVIDE CLOSURE, MEETING THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION, BETWEEN ALL FIRE RESISTANCE RATED CONSTRUCTION
FRO
FOR REFERENCE ONLY
T&G
TONGUE AND GROOVE
AT FLOORS, SHAFTS AND BUILDING PARTITIONS AND ALL PENETRATING DUCTS, PIPES, CONDUIT, MECHANICAL, ELECTRICAL, AND OTHER ITEMS.
E
ELECTRICAL
FT
FOOT
TEMP
TEMPORARY
FTG
FOOTING
THK
THICKNESS)
25)
AT METAL STUD PARTITIONS, EXTEND STUDS FROM FLOOR TO FLOOR OR ROOF DECK ABOVE. WHERE THEY CANNOT DO S0, DUE TO
cW
DOMESTIC WATER
FUT
FUTURE
TOC
TOP OF CONCRETE
INTERFERENCE WITH NEW OR EXISTING DUCTS, PIPING, ETC., PROVIDE BRACING TO STRUCTURE ABOVE TO PROVIDE FOR EQUIVALENT SUPPORT
GA
GAGE
TOC
TOP OF CURB
OF PARTITION; SUBMIT EQUIVALENT SUPPPORT METHOD TO ARCHITECT FOR REVIEW. CONSTRUCT ALL FIRE -RESISTANCE RATED PARTITIONS TO
FW
FIRE WATER
GALV
GALVANIZED
TOL
TOLERANCE
MAINTAIN THEIR RATING FROM FLOOR TO UNDERSIDE OF STRUCTURE ABOVE, U.N.O.
GC
GENERAL CONTRACTOR
TOS
TOP OF STEEL
TM'
TEPID WATER
GI
GALVANIZED IRON
TS
STRUCTURAL TUBE
26)
VERIFY WITH MECHANICAL AND ELECTRICAL SUBCONTRACTORS EXACT LOCATIONS OF ACCESS REQUIRED BY THEIR WORK. PROVIDE ACCESS FOR
GR
GRADE
TYP
TYPICAL
ALL CONCEALED VALVES, DAMPER CONTROLS, FIRE DAMPER LINKAGES, CONCEALED JUNCTION BOXES, AND ELECTRICAL DEVICES OR ACCESSORIES.
��
GT
GROUT
UBC
UNIFORM BUILDING CODE
SUBMIT THE LOCATIONS, SIZES &TYPES OF EXPOSED ACCESS DOORS TO THE ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION OF THE
TEPID WATER COLLECTION
HDNR
HARDENER
UL
UNDERWRITERS' LABEL
MECHANICAL AND ELECTRICAL EQUIPMENT.
�X --0
AUTOMATED SLIDE GATE
HDWD
HARDWOOD
UNO
UPR
UNLESS NOTED OTHERWISE
UPPER
27)
BOEING REQUIRES DEMOUNTABLE WALL SYSTEMS WHERE INDICATED, BE SUPPLIED BY CHASE CONTRACTORS, INC. (206 786-7443).
HDWR
HARDWARE
(0)
TURNSTILE
HG
HIGH GRADE
VB
VAPOR BARRIER
28)
FINISH SCHEDULE INDICATES GENERAL DESIGN INTENT. FIAGNOTES, WHERE LOCATED ON PLAN DRAWINGS MAY INDICATE SPECIFIC EXCEPTION T0
HM
HOLLOW METAL
VERT
VERTICAL
GENERAL FINISH SCHEDULE.
ADA ACCESSIBLE GATE
HOR
HORIZONTALHS
HIGH STRENGTH
W
WEST (COORDINATE)
�
BOLLARD
HT
ID
HEIGHT
INSIDE DIAMETER
W
W
WIDE FLANGE
WIDTH, WIDE
coMMID
COMMUNICATIONS
IF
INSIDE DIMENSION
INSIDE FACE
WO
W/
WHERE OCCURRING
WITH
�
ISSUE FOR CONSTRUCTION R 386502
W/0
WITHOUT
IN
INCL
INCH
INCLUDED(D) (ING)
WWF
WELDED WIRE FABRIC
NOVEMBER 11 2015 �p
, O W L
SYM
REVISION
BY
APPROVED
DATE
SYM
REVISION
BY
APPROVED
DATEMAWN
v 1 S
w .
�ds�i'`i'
ACCEPTABILITY
R.
TEMPLADO
DATE
11.11.15
SUBTITLE
KEY SHEET
CURRENT REVISION
W3441886
SYMBOL
A
DATE
11.11.15
CHECKED
A
737 MAX FLIGHTLINE UTILITIES -APRON
B CI PROJECTW3441886
RT
TWN
11.11.15
JV��
Q,�d of
� �
% Iry
G
THIS DESIGN AND/OR
SPECIFICATION IS APPROVED
T. NEU
11.11.15
SHEET
Gl
T. NEU
1.11.15H
TITLE BOEING 737 MAX FLIGHTLINE UTILITIES -APRON B Cl PROJECT
SITE 05 -YD
APPROVED BY
DEPT.
DATE
K D
D. MURATA
11.11.15
JOB N0.
COMP N0.
APPROVED
eg�O""'�"� ��"
CIVIL MASTER RENTON, WA
W3441886
DWG NO.
c h ,R- - Z