HomeMy WebLinkAboutR-386924CHELAN CREEK PUD Ararnerwwwww5 IL, waM■rw Imum o� oorrrr�r�r LIGHT FIXTURE SCHEDULE BY POINT LOCATION OF v(-�1 NUFA TURER LUMINAIRE � M DUVALL AVE NE 10NE LIGHTING LUMINAIRE: CY55PIUF-GAL-3 JET BLACK #9005TX AVG ME-4K-240-RAL STANDARD PLAN 117.1) MIN POLE: 40' TAPERED ALUMINUM (SEE STANDARD MAX/MMJ PLAN 117.1) 1,12 CLAMP -ON BRACKET: 0.4 (SEE STANDARD PLAN 117.3) 4.75:1 LENGTH CYCLONE LIGHTING LUMINAIRE: CY17T4-VS3AR- STREETS AT TRACT '6' AND 3L3-44W-4000K-UNV (SEE STANDARD PLAN 116.1) CYCLONE LIGHTING POLE: PD15-14-BD46- TRACT 'C DUVALL AVE NE RAL 9005TXOTN43 1+81 SEE STANDARD PLAN 116.1 ILLUMINATION POINT BY POINT STATISTICS POLE ID PROPOSED OFFSET MOUNTING DESCRIPTION AVG MAX MIN AVG/MIN MAX/MMJ STREET LIGHTS DUVALL AVE NE 1,12 1.9 0.4 2.80:1 4.75:1 GRAPHIC SCALE GENERAL NOTES 1. ELECTRICAL CONTRACTOR TO FIELD VERIFY AND COORDINATE EXACT LOCA 77ON OF LIGHT POLES AND JUNCTION BOXES PRIOR TO ROUGH -IN. LIGHT POLES AND JUNCTION BOXES SHALL BE LOCATED OUT OF DRIVEWAYS. IN ADDITION, COORDINATE WITH ALL WATERLINES, METERS, SENER, STORM AND TREE LOCATIONS WHERE APPLICABLE PRIOR TO ROUGH -IN. STREET LIGHT SCHEDULE STREET STREET POLE ID PROPOSED OFFSET MOUNTING ARM CIRCUIT TYPE/WATT/DIST. LUMWNAIRE TYPE BASE COMMENTS LIGHT NO. NO. ** STATION * HEIGHT LENGTH O1 DUVALL AVE NE - 1+81 40' LEFT 35' 8' 1 LED/106W/TYPE III SEE FIXTURE SCHEDULE THIS SHEET FIXED NEW POLE PER RENTON STD PLAN 117.1 *** O2 DUVALL AVE NE - 3+27 40' LEFT 35' 8' 1 LED/106W/TYPE III SEE FIXTURE SCHEDULE THIS SHEET FIXED NEW POLE PER RENTON STD PLAN 117.1 *** O3 DUVALL AVE NE - 4+75 40' LEFT 35' 8' 1 LED/106W/TYPE III SEE FIXTURE SCHEDULE THIS SHEET FIXED NEW POLE PER RENTON STD PLAN 117.1 *** ODUVALL AVE NE - 6+20 40' LEFT 35' 8' 1 LED/106W/TYPE III SEE FIXTURE SCHEDULE THIS SHEET FIXED NEW POLE PER RENTON STD PLAN 117.1 *** OS DUVALL AVE NE - 7+65 40' LEFT 35' 8' 1 LED/106W/TYPE III SEE FIXTURE SCHEDULE THIS SHEET FIXED NEW POLE PER RENTON STD PLAN 117.1 *** �6 TRACT 'B' - N/A N/A -17' N/A 2 LED/44W/TYPE 11 SEE FIXTURE SCHEDULE THIS SHEET FIXED NEW POLE PER RENTON STD PLAN 116.1 7 TRACT 'B' - N/A N/A -17' N/A 2 LED/44W/TYPE II SEE FIXTURE SCHEDULE THIS SHEET FIXED NEW POLE PER RENTON STD PLAN 116.1 a TRACT 'B' - N/A N/A -17' N/A 2 LED/44W/TYPE 11 SEE FIXTURE SCHEDULE THIS SHEET FIXED NEW POLE PER RENTON STD PLAN 116.1 OTRACT 'C' - N/A N/A -17' N/A 2 LED/44W/TYPE II SEE FIXTURE SCHEDULE THIS SHEET FIXED NEW POLE PER RENTON STD PLAN 116.1 TRACT 'C' - N/A N/A -17' N/A 2 LED/44W/TYPE 11 SEE FIXTURE SCHEDULE THIS SHEET FIXED NEW POLE PER RENTON STD PLAN 116.1 * STA TIONS/OFFSETS ARE APPROXIMATE. CONTRACTOR SHALL CONFIRM ANY ADJUSTMENTS WITH ALL TRADES AND ENGINEER PRIOR TO IMPLEMENTING. ** TO BE Nl1MWRED AT THE TIME OF CONSTRUCTION. *** NOTE THAT DETAIL LUMINAIRE MOUNTING HEIGHTS AND ARM LENGTHS HAVE BEEN REVISED AS INDICATED IN THIS SCHEDULE. PEDESTRIAN LUMINAIRE AT 14' MOUNTING HEIGHT NOT REQUIRED. ( INT') 1 inch = 40 ft. 7REET LIGHT CONSTRUCTION 1. ALL W )RKMANSHIP, MATERIALS AND TESTING SHALL BE IN ACCORDANCE WITH WSDOT STANDARDS SPECIFICATIONS AND NATIONAL ELECTRICAL CODE (NEC). 2. ELECTRICAL PERMITS AND INSPECTIONS FROM CITY OF RENTON ARE REQUIRED FOR ALL SITREET LIGHTING INSTALLATIONS WITHIN THE CITY OF RENTON. THE CON TRAC TOR IS RESPONSIBLE FOR OBTAINING PERMITS PRIOR TO CONSTRUCTION. THESE PERMITS ARE AVAILABLE FROM THE ELECTRICAL PERMIT COUNTER AT CITY OF RENTON DEVELOPMENT SERVICES DIVISION 1055 SOUTH GRADY WAY, RENTON, WA 98057. PRIOR TO INSTALLATION OF ANY MATERIALS THE ELECTRICAL CONTRACTOR SHALL SUBMIT A COPY OF THE ELECTRICAL PERMIT AND THE APPROVED PLANS AND DOCUMENTATION. 3. MODIFICATIONS OF ANY PORTION OF THE LIGHTING SYSTEM ARE PROHIBITED WITHOUT PRIOR APPROVAL BY THE CITY. 4. LIGHTING SERVICE CABINET SHALL BE PER CITY OF RENTON STANDARD PLANS 122.1 AND 123. 5. SERNCE ENTRANCE CONDUCTORS SHALL BE A MINIMUM SIZE OF J2 COPPER. ALL LIGHTING WIRE SHALL BE STRANDED COPPER WITH A MfINIMUM SIZE OF #8 WITH INSULATION SUITABLE OF WET LOCATIONS. PHASING TAPE WILL NOT BE ALLOWED. 6. ALL WIRE SHALL BE INSTALLED IN SCHEDULE 40 PVC CONDUIT WITH A MINIMUM DIAMETER OF 2". SCHEDULE 80 PVC OR GALVANIZED STEEL CONDUIT SHALL BE INSTALLED UNDER ROADWAYS. ALL CONDUIT SHALL BE INSTALLED IN THE "UTILITY DITCH" OR AS OTHERWISE DIRECTED BY THE CITY. 7. ALL SPLICES SHALL BE IN THE THE NEAREST JUNCTION BOX. WIRE NUTS WILL NOT BE ALLOWED. ALL SPLICES WILL BE MADE WITH TYPE C COPPER FITTINGS, CENTERED AND ENCASED IN A 3-M SCOTCHCAST EPDXY KIT, RATED AT 600 VOLTS, TYPE 82-A1, 82-B1 OR CITY APPROVED EQUAL. 8. IF MORE THAN ONE CIRCUIT PASSES THROUGH A JUNCTION BOX, EACH IS TO HAVE A PVC SLEEVE CLEARLY IDEN77FWNG THE CIRCUIT. A 500 -VOLT MEGGER TEST WILL BE PERFORMED BY THE ELECTRICAL CONTRACTOR ON EACH CIRCUIT BETWEEN CONDUCTOR AND GROUND PRIOR TO ACCEPTANCE OF THE LIGHTING SYSTEM. THE INSULA71ON RESISTANCE SHALL NOT BE LESS THAN 6 MEGA -OHMS TO GROUND 2,500 FEET AND OVER AND SHALL NOT BE LESS THAN 8 MEGA -OHMS UNDER 2,500 FEET. A FUNCTIONAL TEST SHALL BE PERFORMED TO THE SATISFACTION OF THE CITY, IN WHICH IT IS DEMONSTRATED TO THE CITY THAT EACH AND EVERY PART OF THE SYSTEM FUNCTIONS AS SPECIFIED OR INTENDED HEREIN. 9. EACH LUMINAIRE POLE SHALL HAVE AN SEC IN-LINE, FUSED, WATER TIGHT ELECTRICAL DISCONNECT LOCATED AT THE BASE OF THE POLE. ACCESS TO THESE DISCONNECTS SHALL BE THROUGH THE HAND -HOLE ON THE POLE. THE HAND -HOLE SHALL BE FACING AWAY FROM ONCOMING TRAFFIC FROM THE ADJACENT STREET. LOAD SIDE OF IN-LINE FUSE TO LUMINAIRE HEAD SHALL BE POLE AND BRACKET CABLE, TWO CONDUCTOR, 19 STRAND COPPER #10 AND SHALL BE SUPPORTED AT THE END OF THE LUMINAIRE ARM BY AN APPROVED MEANS. FUSE, SIZE, DISCONNECT INSTALLATION AND GROUNDING IN POLE SHALL CONFORM TO WSDOT STANDARDS. 10. JUNCTION BOXES SHALL BE INSTALLED PER *SDOT STANDARD PLAN J-40.10-03 IN ALL STREET LIGHTING INSTALLATIONS. ALL JUNCTION BOXES SHALL HAVE GALVANIZED LIDS. JUNC77ON BOX LOCA 77ON SHALL BE APPROVED BY THE CITY PRIOR TO INSTALLATION. NO CONDUIT RUN SHALL BE MORE THAN 200 FEET BETWEEN JUNCTION BOXES. A JUNCTION BOX SHALL BE LOCATED WITHIN 10 FEET OF EACH LUMINAIRE POLE AND AT EVERY ROAD CROSSING. NO CONDUIT SHALL BE INSTALLED IN THE ROADWAY EXCEPT AT DESIGNATED ROAD CROSSINGS. CONDUIT ENTERING EKING 711E JUNCTION BOX SHALL BE PERPENDICUALR TO THE SIDES OF THE BOX AND A MINIMUM OF 6 BUT NO MORE THAN 8 INCHES BELOW THE LID. BOXES SHALL BE CLEARLY AND INDELIBLY MARKED AS LIGHTING BOXES BY THE LEGEND "L. T. " OR "LIGHTING" ALL JUNCTION BOXES SHALL BE SUPPORTED BY A MNWMUM 6 -INCH CRUSHED GRAVEL PAD. 11. AFTER INSTALLATION AND BEFORE ACCEPTANCE BY THE CITY, ALL POLES SHALL BE FREE OF DENTS AND MARKS. SONOTUBE SHALL BE REMOVED TO BELOW GROUND LEVEL. POLE BASES SHALL BE GROUTED AND ALL LUMINAIRE HEADS SHALL BE PLUMB AND LEVEL. 12. CONDUIT SHALL EXTEND BETWEEN 3 AND 6 INCHES ABOVE THE CONCRETE BASE. 386902 R=386924 TRIG WRIT ENGINEERS, INC. 2M SOM 42ND Si1NNET. SUM X" TAt2MW IMA IOMM17313 11RAPHOW (253) 472-3300 FAX (253) 393-9/02 CALL 48 HOURS BEFORE YOU DIG DIAL 811