HomeMy WebLinkAboutR-386924CHELAN CREEK PUD
Ararnerwwwww5 IL,
waM■rw Imum o� oorrrr�r�r
LIGHT FIXTURE SCHEDULE
BY POINT
LOCATION OF
v(-�1 NUFA TURER
LUMINAIRE
� M
DUVALL AVE NE
10NE LIGHTING LUMINAIRE: CY55PIUF-GAL-3
JET BLACK #9005TX
AVG
ME-4K-240-RAL
STANDARD PLAN 117.1)
MIN
POLE: 40' TAPERED ALUMINUM (SEE STANDARD
MAX/MMJ
PLAN 117.1)
1,12
CLAMP -ON BRACKET:
0.4
(SEE STANDARD PLAN 117.3)
4.75:1
LENGTH
CYCLONE LIGHTING LUMINAIRE: CY17T4-VS3AR-
STREETS AT
TRACT '6' AND
3L3-44W-4000K-UNV
(SEE STANDARD PLAN 116.1)
CYCLONE LIGHTING POLE: PD15-14-BD46-
TRACT 'C
DUVALL AVE NE
RAL 9005TXOTN43
1+81
SEE STANDARD PLAN 116.1
ILLUMINATION POINT
BY POINT
STATISTICS
POLE ID
PROPOSED
OFFSET
MOUNTING
DESCRIPTION
AVG
MAX
MIN
AVG/MIN
MAX/MMJ
STREET LIGHTS
DUVALL AVE NE
1,12
1.9
0.4
2.80:1
4.75:1
GRAPHIC SCALE
GENERAL NOTES
1. ELECTRICAL CONTRACTOR TO FIELD VERIFY AND COORDINATE
EXACT LOCA 77ON OF LIGHT POLES AND JUNCTION BOXES PRIOR
TO ROUGH -IN. LIGHT POLES AND JUNCTION BOXES SHALL BE
LOCATED OUT OF DRIVEWAYS. IN ADDITION, COORDINATE WITH
ALL WATERLINES, METERS, SENER, STORM AND TREE LOCATIONS
WHERE APPLICABLE PRIOR TO ROUGH -IN.
STREET LIGHT SCHEDULE
STREET
STREET
POLE ID
PROPOSED
OFFSET
MOUNTING
ARM
CIRCUIT
TYPE/WATT/DIST.
LUMWNAIRE TYPE
BASE
COMMENTS
LIGHT NO.
NO. **
STATION *
HEIGHT
LENGTH
O1
DUVALL AVE NE
-
1+81
40' LEFT
35'
8'
1
LED/106W/TYPE III
SEE FIXTURE SCHEDULE THIS SHEET
FIXED
NEW POLE PER RENTON STD PLAN 117.1 ***
O2
DUVALL AVE NE
-
3+27
40' LEFT
35'
8'
1
LED/106W/TYPE III
SEE FIXTURE SCHEDULE THIS SHEET
FIXED
NEW POLE PER RENTON STD PLAN 117.1 ***
O3
DUVALL AVE NE
-
4+75
40' LEFT
35'
8'
1
LED/106W/TYPE III
SEE FIXTURE SCHEDULE THIS SHEET
FIXED
NEW POLE PER RENTON STD PLAN 117.1 ***
ODUVALL
AVE NE
-
6+20
40' LEFT
35'
8'
1
LED/106W/TYPE III
SEE FIXTURE SCHEDULE THIS SHEET
FIXED
NEW POLE PER RENTON STD PLAN 117.1 ***
OS
DUVALL AVE NE
-
7+65
40' LEFT
35'
8'
1
LED/106W/TYPE III
SEE FIXTURE SCHEDULE THIS SHEET
FIXED
NEW POLE PER RENTON STD PLAN 117.1 ***
�6
TRACT 'B'
-
N/A
N/A
-17'
N/A
2
LED/44W/TYPE 11
SEE FIXTURE SCHEDULE THIS SHEET
FIXED
NEW POLE PER RENTON STD PLAN 116.1
7
TRACT 'B'
-
N/A
N/A
-17'
N/A
2
LED/44W/TYPE II
SEE FIXTURE SCHEDULE THIS SHEET
FIXED
NEW POLE PER RENTON STD PLAN 116.1
a
TRACT 'B'
-
N/A
N/A
-17'
N/A
2
LED/44W/TYPE 11
SEE FIXTURE SCHEDULE THIS SHEET
FIXED
NEW POLE PER RENTON STD PLAN 116.1
OTRACT
'C'
-
N/A
N/A
-17'
N/A
2
LED/44W/TYPE II
SEE FIXTURE SCHEDULE THIS SHEET
FIXED
NEW POLE PER RENTON STD PLAN 116.1
TRACT 'C'
-
N/A
N/A
-17'
N/A
2
LED/44W/TYPE 11
SEE FIXTURE SCHEDULE THIS SHEET
FIXED
NEW POLE PER RENTON STD PLAN 116.1
* STA TIONS/OFFSETS ARE APPROXIMATE. CONTRACTOR SHALL CONFIRM ANY ADJUSTMENTS WITH ALL TRADES AND ENGINEER PRIOR TO IMPLEMENTING.
** TO BE Nl1MWRED AT THE TIME OF CONSTRUCTION.
*** NOTE THAT DETAIL LUMINAIRE MOUNTING HEIGHTS AND ARM LENGTHS HAVE BEEN REVISED AS INDICATED IN THIS SCHEDULE. PEDESTRIAN LUMINAIRE AT 14' MOUNTING HEIGHT NOT REQUIRED.
( INT')
1 inch = 40 ft.
7REET LIGHT CONSTRUCTION
1. ALL W )RKMANSHIP, MATERIALS AND TESTING SHALL BE IN ACCORDANCE
WITH WSDOT STANDARDS SPECIFICATIONS AND NATIONAL ELECTRICAL
CODE (NEC).
2. ELECTRICAL PERMITS AND INSPECTIONS FROM CITY OF RENTON ARE
REQUIRED FOR ALL SITREET LIGHTING INSTALLATIONS WITHIN THE CITY
OF RENTON. THE CON TRAC TOR IS RESPONSIBLE FOR OBTAINING
PERMITS PRIOR TO CONSTRUCTION. THESE PERMITS ARE AVAILABLE
FROM THE ELECTRICAL PERMIT COUNTER AT CITY OF RENTON
DEVELOPMENT SERVICES DIVISION 1055 SOUTH GRADY WAY, RENTON, WA
98057. PRIOR TO INSTALLATION OF ANY MATERIALS THE ELECTRICAL
CONTRACTOR SHALL SUBMIT A COPY OF THE ELECTRICAL PERMIT AND
THE APPROVED PLANS AND DOCUMENTATION.
3. MODIFICATIONS OF ANY PORTION OF THE LIGHTING SYSTEM ARE
PROHIBITED WITHOUT PRIOR APPROVAL BY THE CITY.
4. LIGHTING SERVICE CABINET SHALL BE PER CITY OF RENTON STANDARD
PLANS 122.1 AND 123.
5. SERNCE ENTRANCE CONDUCTORS SHALL BE A MINIMUM SIZE OF
J2 COPPER. ALL LIGHTING WIRE SHALL BE STRANDED COPPER
WITH A MfINIMUM SIZE OF #8 WITH INSULATION SUITABLE OF WET
LOCATIONS. PHASING TAPE WILL NOT BE ALLOWED.
6. ALL WIRE SHALL BE INSTALLED IN SCHEDULE 40 PVC CONDUIT
WITH A MINIMUM DIAMETER OF 2". SCHEDULE 80 PVC OR
GALVANIZED STEEL CONDUIT SHALL BE INSTALLED UNDER
ROADWAYS. ALL CONDUIT SHALL BE INSTALLED IN THE
"UTILITY DITCH" OR AS OTHERWISE DIRECTED BY THE CITY.
7. ALL SPLICES SHALL BE IN THE THE NEAREST JUNCTION BOX.
WIRE NUTS WILL NOT BE ALLOWED. ALL SPLICES WILL BE MADE
WITH TYPE C COPPER FITTINGS, CENTERED AND ENCASED IN A
3-M SCOTCHCAST EPDXY KIT, RATED AT 600 VOLTS, TYPE 82-A1,
82-B1 OR CITY APPROVED EQUAL.
8. IF MORE THAN ONE CIRCUIT PASSES THROUGH A JUNCTION BOX,
EACH IS TO HAVE A PVC SLEEVE CLEARLY IDEN77FWNG THE
CIRCUIT. A 500 -VOLT MEGGER TEST WILL BE PERFORMED BY
THE ELECTRICAL CONTRACTOR ON EACH CIRCUIT BETWEEN
CONDUCTOR AND GROUND PRIOR TO ACCEPTANCE OF THE
LIGHTING SYSTEM. THE INSULA71ON RESISTANCE SHALL NOT BE
LESS THAN 6 MEGA -OHMS TO GROUND 2,500 FEET AND OVER
AND SHALL NOT BE LESS THAN 8 MEGA -OHMS UNDER 2,500
FEET. A FUNCTIONAL TEST SHALL BE PERFORMED TO THE
SATISFACTION OF THE CITY, IN WHICH IT IS DEMONSTRATED TO
THE CITY THAT EACH AND EVERY PART OF THE SYSTEM
FUNCTIONS AS SPECIFIED OR INTENDED HEREIN.
9. EACH LUMINAIRE POLE SHALL HAVE AN SEC IN-LINE, FUSED,
WATER TIGHT ELECTRICAL DISCONNECT LOCATED AT THE BASE
OF THE POLE. ACCESS TO THESE DISCONNECTS SHALL BE
THROUGH THE HAND -HOLE ON THE POLE. THE HAND -HOLE
SHALL BE FACING AWAY FROM ONCOMING TRAFFIC FROM THE
ADJACENT STREET. LOAD SIDE OF IN-LINE FUSE TO LUMINAIRE
HEAD SHALL BE POLE AND BRACKET CABLE, TWO CONDUCTOR,
19 STRAND COPPER #10 AND SHALL BE SUPPORTED AT THE
END OF THE LUMINAIRE ARM BY AN APPROVED MEANS. FUSE,
SIZE, DISCONNECT INSTALLATION AND GROUNDING IN POLE SHALL
CONFORM TO WSDOT STANDARDS.
10. JUNCTION BOXES SHALL BE INSTALLED PER *SDOT STANDARD
PLAN J-40.10-03 IN ALL STREET LIGHTING INSTALLATIONS. ALL
JUNCTION BOXES SHALL HAVE GALVANIZED LIDS. JUNC77ON BOX
LOCA 77ON SHALL BE APPROVED BY THE CITY PRIOR TO
INSTALLATION. NO CONDUIT RUN SHALL BE MORE THAN 200
FEET BETWEEN JUNCTION BOXES. A JUNCTION BOX SHALL BE
LOCATED WITHIN 10 FEET OF EACH LUMINAIRE POLE AND AT
EVERY ROAD CROSSING. NO CONDUIT SHALL BE INSTALLED IN
THE ROADWAY EXCEPT AT DESIGNATED ROAD CROSSINGS.
CONDUIT ENTERING EKING 711E JUNCTION BOX SHALL BE
PERPENDICUALR TO THE SIDES OF THE BOX AND A MINIMUM OF
6 BUT NO MORE THAN 8 INCHES BELOW THE LID. BOXES SHALL
BE CLEARLY AND INDELIBLY MARKED AS LIGHTING BOXES BY
THE LEGEND "L. T. " OR "LIGHTING" ALL JUNCTION BOXES SHALL
BE SUPPORTED BY A MNWMUM 6 -INCH CRUSHED GRAVEL PAD.
11. AFTER INSTALLATION AND BEFORE ACCEPTANCE BY THE CITY,
ALL POLES SHALL BE FREE OF DENTS AND MARKS. SONOTUBE
SHALL BE REMOVED TO BELOW GROUND LEVEL. POLE BASES
SHALL BE GROUTED AND ALL LUMINAIRE HEADS SHALL BE
PLUMB AND LEVEL.
12. CONDUIT SHALL EXTEND BETWEEN 3 AND 6 INCHES ABOVE THE
CONCRETE BASE.
386902
R=386924
TRIG WRIT ENGINEERS, INC.
2M SOM 42ND Si1NNET. SUM X"
TAt2MW IMA IOMM17313
11RAPHOW (253) 472-3300
FAX (253) 393-9/02
CALL 48 HOURS
BEFORE YOU DIG
DIAL 811