Loading...
HomeMy WebLinkAboutzT-3869Seti.A-c_ E I - 1 _ i LEGEND PEDESTRIAN SCALE LIGHT POLE, LUMINAIRE do FOUNDATION. ( = POLE) REFERENCE CITY OF RENTON STANDARD PLAN 116.1. IN ADDITION, REFERENCE SECTION 4-6-060 (1) (ILLUMINATION) O OF THE CITY OF RENTON GUIDELINES do STANDARDS FOR STREET LIGHTING DESIGN OF RESIDENTIAL AND ARTERIAL STREET. (ORD. 5517, 12-14-2009; ORD. 5675, 12-3-2012) ARTERIAL STREET LIGHT POLE, LUMINAIRE & FOUNDATION. REFERENCE CITY OF RENTON STANDARD PLANS 117.2 AND 120. ( =POLE) IN ADDITION, REFERENCE SECTION 4-6-060 (1) (ILLUMINATION) O OF THE CITY OF RENTON GUIDELINES do STANDARDS FOR STREET LIGHTING DESIGN OF RESIDENTIAL AND ARTERIAL STREET. (ORD. 5517, 12-14-2009; ORD. 5675, 12-3-2012) O ( = PO ) PATHWAY 42" BOLLARD, & FOUNDATION. SEE LIGHT FIXTURE O1 SCHEDULE FOR ADDITIONAL INFORMATION. FIXTURES TO BE OWNED AND MAINTAINED BY THE HOMEOWNERS ASSOCIATION. **SEE PATHWAY LIGHTING — PRIVATE (SHEETS E7 AND E8)** PULL BOX WITH ANTI SLIP LOCKING LID. (SEE WSDOT TYPE 1 J-40.10-02 STANDARD DWGS) ® PROVIDE 1 " TACK WELDS AT BOTH ENDS OF THE J—BOX LID —�---- UNDERGROUND CONDUIT do WIRE. RUN NUMBER, SEE SHEET E2, VOLTAGE DROP CALCULATION Q do WIRING SCHEDULE FOR ADDITIONAL INFORMATION. SERVICE CABINET & FOUNDATION REFERENCE CITY OF RENTON STANDARD PLANS 122.1, 123 AND 126.1 t CMAN CREEK PUD AroRnoNatwwworsTowrUa91. wu�rw �R oM aawrr. ��w GENERAL NOTE GRAPHIC' SCALE ao o 15 30 eo I inch = 30 tt. 1. LIGHTING FIXTURES 11-48 ARE PRIVATE PATHWAY LIGHTING. SEE PATHWAY LIGHTING — PRIVATE SHEETS E7 AND E8. PLAN NOTES O CONTRACTOR TO FIELD VERIFY LOCATION OF LIGHTING SERVICE CABINET AND NEAREST UTILITY 2401120V TRANSFORMER. COORDINATE ALL REQUIREMENTS AND CONNECTIONS WITH PUGET SOUND ENERGY AND CITY OF RENTON TRANSPORTATION MAINTENANCE MANAGER ERIC CU TSHALL. C f 11. Al v. f,2 S- y- 3o - 7 yr Z 3 .) (D PROVIDE NEW SKYLINE STREET LIGHTING SERVICE CABINET WITH CONCRETE FOUNDATION PER CITY OF RENTON STANDARDS. PROV10E 2" CONDUIT, 3#2 WIRING AND CONNECTIONS TO 240-120 VOLT TRANSFORMER. SEE PLAN NOTE 1. O PROVIDE PULL BOX IN CONCRETE PAD AT END OF SIDEWALK AND A 2" CONDUIT ONLY AS SHOWN FOR FUTURE EXTENSION OF STREET LIGHTING. ! II i li r II II r! L — 1 --- --- - - - - - ------- 5,721 SF 2, F ` ; + o 1 I --�--_=_ - HOUSE —_ t t ----- - • O HT1 -- _ -- -_ - ! I l - - - rte-- --- Z ' t � 3 -- — O ---- 46 .00 40 r � .�........� ^•--•- — - — - -' _ .. � • - .:;.— — = — ........ . .. . ... -� a* 004 �-— --------�----- ------------ — — -- — ----------------------------- 1+00 a: 2+003+00 -� -- - 4+00 5+00 6+00 7+00 8+00AI CD �- T DtNALL AVENL E N.E. _ _ W CL \ �� _ _..._a a .__ I a _---------- __i..a a s JL !L J1 \ / � �-_ a -1 -L_.—i __.._s .._i�—1...--5 _ - - \ ' - -- �x 1 '�� \ / DPH - TIES WILT ENGINEERS, INC. DPH / XM SOU14 400 silET, SUM Set C9i��i DPH 1� TAC*Mk VIA 98*0-735 (jai) 472—MW386901 1 ( FAK ((253)363-9402z NONE 12.29.15 R-386913 CALL 48 HOURS BEFORE YOU DIG DIAL 811 C D, K 3g% q > � 1 1 3 A g 0 t i i i ooa I I CHELAN CREEK PUD Ararnerwwwww5 IL, waM■rw Imum o� oorrrr�r�r LIGHT FIXTURE SCHEDULE BY POINT LOCATION OF v(-�1 NUFA TURER LUMINAIRE � M DUVALL AVE NE 10NE LIGHTING LUMINAIRE: CY55PIUF-GAL-3 JET BLACK #9005TX AVG ME-4K-240-RAL STANDARD PLAN 117.1) MIN POLE: 40' TAPERED ALUMINUM (SEE STANDARD MAX/MMJ PLAN 117.1) 1,12 CLAMP -ON BRACKET: 0.4 (SEE STANDARD PLAN 117.3) 4.75:1 LENGTH CYCLONE LIGHTING LUMINAIRE: CY17T4-VS3AR- STREETS AT TRACT '6' AND 3L3-44W-4000K-UNV (SEE STANDARD PLAN 116.1) CYCLONE LIGHTING POLE: PD15-14-BD46- TRACT 'C DUVALL AVE NE RAL 9005TXOTN43 1+81 SEE STANDARD PLAN 116.1 ILLUMINATION POINT BY POINT STATISTICS POLE ID PROPOSED OFFSET MOUNTING DESCRIPTION AVG MAX MIN AVG/MIN MAX/MMJ STREET LIGHTS DUVALL AVE NE 1,12 1.9 0.4 2.80:1 4.75:1 GRAPHIC SCALE GENERAL NOTES 1. ELECTRICAL CONTRACTOR TO FIELD VERIFY AND COORDINATE EXACT LOCA 77ON OF LIGHT POLES AND JUNCTION BOXES PRIOR TO ROUGH -IN. LIGHT POLES AND JUNCTION BOXES SHALL BE LOCATED OUT OF DRIVEWAYS. IN ADDITION, COORDINATE WITH ALL WATERLINES, METERS, SENER, STORM AND TREE LOCATIONS WHERE APPLICABLE PRIOR TO ROUGH -IN. STREET LIGHT SCHEDULE STREET STREET POLE ID PROPOSED OFFSET MOUNTING ARM CIRCUIT TYPE/WATT/DIST. LUMWNAIRE TYPE BASE COMMENTS LIGHT NO. NO. ** STATION * HEIGHT LENGTH O1 DUVALL AVE NE - 1+81 40' LEFT 35' 8' 1 LED/106W/TYPE III SEE FIXTURE SCHEDULE THIS SHEET FIXED NEW POLE PER RENTON STD PLAN 117.1 *** O2 DUVALL AVE NE - 3+27 40' LEFT 35' 8' 1 LED/106W/TYPE III SEE FIXTURE SCHEDULE THIS SHEET FIXED NEW POLE PER RENTON STD PLAN 117.1 *** O3 DUVALL AVE NE - 4+75 40' LEFT 35' 8' 1 LED/106W/TYPE III SEE FIXTURE SCHEDULE THIS SHEET FIXED NEW POLE PER RENTON STD PLAN 117.1 *** ODUVALL AVE NE - 6+20 40' LEFT 35' 8' 1 LED/106W/TYPE III SEE FIXTURE SCHEDULE THIS SHEET FIXED NEW POLE PER RENTON STD PLAN 117.1 *** OS DUVALL AVE NE - 7+65 40' LEFT 35' 8' 1 LED/106W/TYPE III SEE FIXTURE SCHEDULE THIS SHEET FIXED NEW POLE PER RENTON STD PLAN 117.1 *** �6 TRACT 'B' - N/A N/A -17' N/A 2 LED/44W/TYPE 11 SEE FIXTURE SCHEDULE THIS SHEET FIXED NEW POLE PER RENTON STD PLAN 116.1 7 TRACT 'B' - N/A N/A -17' N/A 2 LED/44W/TYPE II SEE FIXTURE SCHEDULE THIS SHEET FIXED NEW POLE PER RENTON STD PLAN 116.1 a TRACT 'B' - N/A N/A -17' N/A 2 LED/44W/TYPE 11 SEE FIXTURE SCHEDULE THIS SHEET FIXED NEW POLE PER RENTON STD PLAN 116.1 OTRACT 'C' - N/A N/A -17' N/A 2 LED/44W/TYPE II SEE FIXTURE SCHEDULE THIS SHEET FIXED NEW POLE PER RENTON STD PLAN 116.1 TRACT 'C' - N/A N/A -17' N/A 2 LED/44W/TYPE 11 SEE FIXTURE SCHEDULE THIS SHEET FIXED NEW POLE PER RENTON STD PLAN 116.1 * STA TIONS/OFFSETS ARE APPROXIMATE. CONTRACTOR SHALL CONFIRM ANY ADJUSTMENTS WITH ALL TRADES AND ENGINEER PRIOR TO IMPLEMENTING. ** TO BE Nl1MWRED AT THE TIME OF CONSTRUCTION. *** NOTE THAT DETAIL LUMINAIRE MOUNTING HEIGHTS AND ARM LENGTHS HAVE BEEN REVISED AS INDICATED IN THIS SCHEDULE. PEDESTRIAN LUMINAIRE AT 14' MOUNTING HEIGHT NOT REQUIRED. ( INT') 1 inch = 40 ft. 7REET LIGHT CONSTRUCTION 1. ALL W )RKMANSHIP, MATERIALS AND TESTING SHALL BE IN ACCORDANCE WITH WSDOT STANDARDS SPECIFICATIONS AND NATIONAL ELECTRICAL CODE (NEC). 2. ELECTRICAL PERMITS AND INSPECTIONS FROM CITY OF RENTON ARE REQUIRED FOR ALL SITREET LIGHTING INSTALLATIONS WITHIN THE CITY OF RENTON. THE CON TRAC TOR IS RESPONSIBLE FOR OBTAINING PERMITS PRIOR TO CONSTRUCTION. THESE PERMITS ARE AVAILABLE FROM THE ELECTRICAL PERMIT COUNTER AT CITY OF RENTON DEVELOPMENT SERVICES DIVISION 1055 SOUTH GRADY WAY, RENTON, WA 98057. PRIOR TO INSTALLATION OF ANY MATERIALS THE ELECTRICAL CONTRACTOR SHALL SUBMIT A COPY OF THE ELECTRICAL PERMIT AND THE APPROVED PLANS AND DOCUMENTATION. 3. MODIFICATIONS OF ANY PORTION OF THE LIGHTING SYSTEM ARE PROHIBITED WITHOUT PRIOR APPROVAL BY THE CITY. 4. LIGHTING SERVICE CABINET SHALL BE PER CITY OF RENTON STANDARD PLANS 122.1 AND 123. 5. SERNCE ENTRANCE CONDUCTORS SHALL BE A MINIMUM SIZE OF J2 COPPER. ALL LIGHTING WIRE SHALL BE STRANDED COPPER WITH A MfINIMUM SIZE OF #8 WITH INSULATION SUITABLE OF WET LOCATIONS. PHASING TAPE WILL NOT BE ALLOWED. 6. ALL WIRE SHALL BE INSTALLED IN SCHEDULE 40 PVC CONDUIT WITH A MINIMUM DIAMETER OF 2". SCHEDULE 80 PVC OR GALVANIZED STEEL CONDUIT SHALL BE INSTALLED UNDER ROADWAYS. ALL CONDUIT SHALL BE INSTALLED IN THE "UTILITY DITCH" OR AS OTHERWISE DIRECTED BY THE CITY. 7. ALL SPLICES SHALL BE IN THE THE NEAREST JUNCTION BOX. WIRE NUTS WILL NOT BE ALLOWED. ALL SPLICES WILL BE MADE WITH TYPE C COPPER FITTINGS, CENTERED AND ENCASED IN A 3-M SCOTCHCAST EPDXY KIT, RATED AT 600 VOLTS, TYPE 82-A1, 82-B1 OR CITY APPROVED EQUAL. 8. IF MORE THAN ONE CIRCUIT PASSES THROUGH A JUNCTION BOX, EACH IS TO HAVE A PVC SLEEVE CLEARLY IDEN77FWNG THE CIRCUIT. A 500 -VOLT MEGGER TEST WILL BE PERFORMED BY THE ELECTRICAL CONTRACTOR ON EACH CIRCUIT BETWEEN CONDUCTOR AND GROUND PRIOR TO ACCEPTANCE OF THE LIGHTING SYSTEM. THE INSULA71ON RESISTANCE SHALL NOT BE LESS THAN 6 MEGA -OHMS TO GROUND 2,500 FEET AND OVER AND SHALL NOT BE LESS THAN 8 MEGA -OHMS UNDER 2,500 FEET. A FUNCTIONAL TEST SHALL BE PERFORMED TO THE SATISFACTION OF THE CITY, IN WHICH IT IS DEMONSTRATED TO THE CITY THAT EACH AND EVERY PART OF THE SYSTEM FUNCTIONS AS SPECIFIED OR INTENDED HEREIN. 9. EACH LUMINAIRE POLE SHALL HAVE AN SEC IN-LINE, FUSED, WATER TIGHT ELECTRICAL DISCONNECT LOCATED AT THE BASE OF THE POLE. ACCESS TO THESE DISCONNECTS SHALL BE THROUGH THE HAND -HOLE ON THE POLE. THE HAND -HOLE SHALL BE FACING AWAY FROM ONCOMING TRAFFIC FROM THE ADJACENT STREET. LOAD SIDE OF IN-LINE FUSE TO LUMINAIRE HEAD SHALL BE POLE AND BRACKET CABLE, TWO CONDUCTOR, 19 STRAND COPPER #10 AND SHALL BE SUPPORTED AT THE END OF THE LUMINAIRE ARM BY AN APPROVED MEANS. FUSE, SIZE, DISCONNECT INSTALLATION AND GROUNDING IN POLE SHALL CONFORM TO WSDOT STANDARDS. 10. JUNCTION BOXES SHALL BE INSTALLED PER *SDOT STANDARD PLAN J-40.10-03 IN ALL STREET LIGHTING INSTALLATIONS. ALL JUNCTION BOXES SHALL HAVE GALVANIZED LIDS. JUNC77ON BOX LOCA 77ON SHALL BE APPROVED BY THE CITY PRIOR TO INSTALLATION. NO CONDUIT RUN SHALL BE MORE THAN 200 FEET BETWEEN JUNCTION BOXES. A JUNCTION BOX SHALL BE LOCATED WITHIN 10 FEET OF EACH LUMINAIRE POLE AND AT EVERY ROAD CROSSING. NO CONDUIT SHALL BE INSTALLED IN THE ROADWAY EXCEPT AT DESIGNATED ROAD CROSSINGS. CONDUIT ENTERING EKING 711E JUNCTION BOX SHALL BE PERPENDICUALR TO THE SIDES OF THE BOX AND A MINIMUM OF 6 BUT NO MORE THAN 8 INCHES BELOW THE LID. BOXES SHALL BE CLEARLY AND INDELIBLY MARKED AS LIGHTING BOXES BY THE LEGEND "L. T. " OR "LIGHTING" ALL JUNCTION BOXES SHALL BE SUPPORTED BY A MNWMUM 6 -INCH CRUSHED GRAVEL PAD. 11. AFTER INSTALLATION AND BEFORE ACCEPTANCE BY THE CITY, ALL POLES SHALL BE FREE OF DENTS AND MARKS. SONOTUBE SHALL BE REMOVED TO BELOW GROUND LEVEL. POLE BASES SHALL BE GROUTED AND ALL LUMINAIRE HEADS SHALL BE PLUMB AND LEVEL. 12. CONDUIT SHALL EXTEND BETWEEN 3 AND 6 INCHES ABOVE THE CONCRETE BASE. 386902 R=386924 TRIG WRIT ENGINEERS, INC. 2M SOM 42ND Si1NNET. SUM X" TAt2MW IMA IOMM17313 11RAPHOW (253) 472-3300 FAX (253) 393-9/02 CALL 48 HOURS BEFORE YOU DIG DIAL 811 CHELAN CREEK PUD a 94 w V4renMwTaw�saw���, wurerw 11111111N^ HIM ae�rtr� �w■iwrr VOLTAGE DROP AND LOAD CALCULATIONS STREET LIGHTING V CALCUIATM POILE ACrff. SCHEDULE 40/80 PVC CONDUIT NOMEMS 20 VOLTS I OM LED FD(TURE REMARKS 0.44 44W LED FIXTURE C 0.18 Canduckm Loa Factors pf, CU, MonteWe Cowl Wro Size 8 6 4 3 2 Ems' 0.00131 0.000645 0.000553 0.000456 0.000358 SELEC T1 (C ircuk 1) *Voftge Drop=DiSbv,Lce X Ampwes x ConduMr Lass Faclor RUN NO. ....... .... DISTANCE .. ... ...:. CURRENT VOLTS ......... ....... ........ ...... ...... ........ _.. .... 2" (FEET) (AMPERES) DRP CIRCUIT 1 ILLUMINATION Q2" 1 0 0.00 0.00 2 40 1.76 0.09 3 400.44 ... .. ..... 0.02 4 170 0.88 0.20 5 40 0.44 0.02 6 170 0.44 0.10 7 40 0.44 0.02 8 170 0.88 0.20 s 40 0.44 0.02 10 170 0.44 0.10 11 40 0.44 0.02 12 225 0.36 0.11 13 145 0.18 0.03 14 215 0.54 0.15 15 _ 170 0.54 0.12 16 130 0.36 0.06 17 110 0.18 0.03 TOTAL 1915 1.39 0.54% em VOLTS GRAPHIC SCALE 40 0 20 40 SO i MR ria ) 1 inch = 40 it. STREET CONDUIT/WIRING SCHEDULE RUN NO. SCHEDULE 40/80 PVC CONDUIT CONDUCTORS CIRCUIT REMARKS SIZE LENGTH C Z me NO. d Q2" - 3#2, 1 #2 GR - UTILITY CONNECTION Q2" 40 LF 2#8, 1 #8 GR 1 ILLUMINATION Q3 2" 40 LF 2#8, 1 #8 GR 1 ILLUMINATION Q2" 170 LF 2#8, 1#8 GR 1 ILLUMINATION Q2" 40 LF 2#8, 1#8 GR 1 ILLUMINATION Q6 2" 170 LF 2#8, 1 #8 GR 1 ILLUMINATION Q7 2" 40 LF 2#8, 1#8 GR 1 ILLUMINATION 2" 170 LF 2#8, 1#8 GR 1 ILLUMINATION Q2" 40 LF 2#8, 1 #8 GR 1 ILLUMINATION ® 2" 170 LF 2#8, 1 #8 GR 1 ILLUMINATION © 2" 40 LF 2#8, 1#8 GR 1 ILLUMINATION © 2" 225 LF 2#8, 1 #8 GR 1 ILLUMINATION © 2" 145 LF 2#8, 1#6 GR 1 ILLUMINATION © 2" 215 LF 2#8, 1#8 GR 1 ILLUMINATION ® 2" 170 LF 2#8, 1#8 GR 1 ILLUMINATION ® 2" 130 LF 2#8, 1#8 GR 1 ILLUMINATION © 2" 110 LF 2#8, 1#8 GR 1 ILLUMINATION 38690 1 38692 TRIG •IGT ENGINEERS, INC. 270"it SOM 43M SIPW IUM 301 TACOMk VA 98400-7315 113.840K (253) 472-3300 FAX (253) 363-94M CALL 48 HOURS BEFORE YOU DIG DIAL 811 C-r->� c --� I�. 'r- � � 4z z 0 D N r, cD n � t-Ja� C Z me d Qo Q AL`L�AIRE AND POLE RELATED PARTS SHALL BE FACTORY PRIDED AND POWDER COATED, FINISH COLOR: RAL 9005TX "JET BLACK - ;8 -1/4" PRESTIGE SERIES (r_Y174) LED POST -TOP LUMINAIRE (WATTAGE PER PLANS, 4,000K CCT, 120-277V UNIVERSAL 'DRIVER, WITH VS3AR A; <2 RIBBED ACRYIC LENS) BY CYCLONE �- (OR APPROVED EQUAL). DRIVER SHALL BE INTEGRA_ TO THE r FIXTURE. FOR STREET LIGHT STANDARD DECAL NUMBERING DETAIL, REFER TO CITY OF RENTOON STD PLAN 121 14'-0" FLUTED SHAPE, 5" DIAMETER, STRAIGHT ALUMINUM POLE (PD15--14-BD46-RAL9005TX-TN43) BY CYCLONE (OR APPROVED EQUAL) INSTALL GROUT. PROVIDE 1/2" 'DIA DRAIN TUBE THROUGH GROUT. 2"x5" HANDH04LE DECORATIVE ALUMINUM CL.AMSntL_ BASE COVER BD46 BY CYCLONE (OR APPROVED EQUAL) SEE PULE BASE DETAIL, THIS SHEET 16" DIAMETER BASE COVER 2" CONDUIT UN STATED OTHERV PLANS ANCHOR BOLT (4) OVAL SLOTS ACCEPTING 1"06%4" 41 OVAL SLOTS GALVANIZED STEEL ...... ...... ................ (LUMINAIRE AFM LENGTH) ANCHOR BOLTS Ix ALL ALUMHN LUMINAKE AND POLEf ROUND POLE CAP ALUMINIUM 5HROUD (BY GALVAN€ZED STEEL RELATED PARTS SHALL BE FACTORY L� t� m ANCHOR BOLTS PRIMED ANDPOWDERCOATED.MANUFACTURER) PAL 9005TX ";ET BLA£I::" _....... m D A BASE PLATE DETAIL ...... .... ........ 24" 8 -- #5 BARS, I r DOME STYLE LED LLURANIE EVENLY SPACED (LUMINAIRE ARM LENGTH) LUMINARE ARM (WATTAGE CENTER CONDUIT IN FOUNDATION `.a BOLT CIRCLE (DIA PER BASE PLATE DETAIL, THIS SHEET) X14 HOOPS @ 12" FOUNDATION SECTION LEEM,TH PER PLANS' 20-277V UNIVERSAL DRIVER. 07H •� 2" CONDUIT UNLESS_\ F GROUND POLE TO STATED OTHERWISE ON FOUNDATION PLANS 3/4' CHAMFER (TYP) ;., ,n 1'-6" MMI BELOW GROUND, 2'-0" MIN UNDER PAVEMENT EXTEND THE CONDUIT - 6" MIN BEYOND FOUNDATION OR THE CONTROLLED DENSITY BACKFILL /4 HOOPS A 12' 8 - 15 BARS, EVENLY SPACED 2 1/2' CLR --• MIN. BOLT ;r IJECTION 1 �-- FOR FOUNDATION DETAILS, SEE TH€S SHI=T PO" 111"AlIM POLE BASE DETAIL Ln J CL uj a CL w 0 z 0 z 2 24" FOUNDATION DETAIL 7/8" DIA HOLE (TYP) !�+ 1/4" STEEL PLATE BOLT CIRCLE (DIA PER BASE PLATE DETAIL., THIS SHEET) ANCHOR BOLT TEMPLATE DETAIL ANCHOR BOLT, 4 TOTAL, 3/4' DU (TYP) 0 N 3/4" HEX NUTS, STEEL (6 REQ -13 PER ANCHOR BOLT), FLAT WASHERS (6 REQ`D PER ANCHOR BOLT) ANCHOR BOLT ASSEMBLY DETAIL. FOull"T m NAILS STD. PLAN ­ 116.1 ♦ ♦ PUBLIC WORKS W_ TWA" LUMINAIRE ET PROVE DEPARTMENTFIXTUM � 114DL.E DETAILS if """*ALl .......... z 41 OVAL SLOTS ' AN _SPECIFICATIONS -ACCEPTING ...... ...... ................ (LUMINAIRE AFM LENGTH) G 1"x4Q"x4 ALL ALUMHN LUMINAKE AND POLEf ROUND POLE CAP ALUMINIUM 5HROUD (BY GALVAN€ZED STEEL RELATED PARTS SHALL BE FACTORY t� m ANCHOR BOLTS PRIMED ANDPOWDERCOATED.MANUFACTURER) PAL 9005TX ";ET BLA£I::" _....... m D A ...... .... ........ 4' OD HIOL-1 I r DOME STYLE LED LLURANIE (LUMINAIRE ARM LENGTH) LUMINARE ARM (WATTAGE TO° R 30" `.a PER PLANS, 4.M, CCT � tQRATI RAJ` NOTES ''' LEEM,TH PER PLANS' 20-277V UNIVERSAL DRIVER. 07H •� `:... 4" OD HOLE t'� MA!K • ROL►ND TUBULAR SECTION F ..... .... <L.AT GLASS LENS BY CYCLONE le ATE DETAII* ' qa ICIR _ELLA»...... (LUMINAIRE ARM LENGTH) ( ....... .... 'NO TAPER) .�;" 457' R APPROVED EOUAL). DRIVER ........._.�.. `� z i SHALL BE INTEGRAL TO THE .� ROUND TAPERED ROLE SECTION [ FIxT1JRE VAT14 CLAM SHELL ARM CONNECTION. FOR M0(IN' ING ARM ?6... 8 ._. yl BARS, (0 €4„/FT) l : . :.... DETAILS SEE _TC PLAN 1.7.3 EVENLY SPACED, t+♦ NfJM1NAL. LLPAtNAIRE HEIGHT .. `28” . ,~-- CENTER L OND IIT (LI. MNAIRE MEIG.'�T + SHRL�C� ) y 2" CONDUIT DESS 1N I ;.N! }A"TI IIV 60' T* 46 • STATED OTHE-ROSE ON (2) BANNER BRACKETS W11..TH PLANS 14'.15" DFA BOLT PRESSURE RELEASE SPRINGS att ri WITH PROTECTIVE RUSBFR ANCHOR BOLT rT1N4; COASE1rURE #4 HOOP 0 12" TOP BANNER BRACKET VNTH n L%1 :1.. THROUGH BOLTS AND SHN T^ LEVEL �f lj(�'ATI1�I;N ." Tli l�I PER MANUFACTtWR'S 1NSTRUCTI%, *S 2` COND'.�IT 'UNLESS GRAND POLE TO SECURE BOTTOM BANNER BRACtiET OPTIONAL.. STATEDOTHfRVMSE ON FOlUNDATION BANNER TC BE NTH ADJUSTABLE STAINLESS STEEL � � PROVIDED AND PLANS BANDS AND SHIM TO LEVEL PER INSTALLED - BY � MAINUFAr. TU FR'S INSTRUCTIONS OTHERS 3/4" CHAMFER ('YP! t t ''-6" MIN BELOW GROUND, �.. 2'-0' MIN UNDER PAVEMENT } I. EXTEND THE C04OVI T .. _.... I< DOME STYLE LED LUMINAIRE 6' MIN BEY=OND (WATTAGE PER PLANS, 4,MOK FOUNDATION OR THE { CCT: !?0-277V UNIVERSAL CONTROLLED DENSITY 1 a DRIVER, WITH FLAT GLASS LENS) 0' LEvu_ BACKFILLui sx BY CYCLONE (OR APPROVED 4',,.0» ) .. . EOUA.F DRIV£R SHALL � LUMINAIRE ARS+ M s i , /4 HOOPS i � x INTEGRAL. T=0 THE FIXTURE WITH _ rLAM SHELL ARM CONNECT101:. [.. .... .� = 8 - 07 BARS, F1-1 C4t MOUNTING ARM DETAIL :o EVENLY SPACED STD Pi AN 117,3. 'n . /2p CI ... z 32 25" r 1 E �•C.3 _ FOR STREET LIGHT �.� . 180, !.. STANDARD DECAL NUMBERING DETAIL. 270' REFER TO CITY OF REN TON STD PLAN FOI,)NQATI N D TAIL r 121 4 • DECORAT=VE ROADWAY LUMINAIRES ARE MOUNTED AT D' 1 1/4" DIA HOLE 1€}" BASE DIAMETER, '' ` • DECORATIVE PEDESTRIAN LUMINAIRES '. (TYP) 40'-0' LC3G ARE MOUNTED AT 180' HAI+iDM0LES z . �, ik+(INUCJ}> 0,25" i ARE MOUNTED AT 150' � . 3; 9" �Tk.F.t. RATEL� WALL TH'Ckl4E SMOOTH • BANNER SUPPORT BRACKETS ARE Cs ROUND TAPERED �.s or � . MOUNTED AT 0' ........:..... 5 BOLT �✓IR LE (DIA OAC/FT, ALUMNNUM ,POLE� m : RIENTATI N I C��N. TO BSIZE ASE LA�AIRE REINFORCED HAI• W0LE.. DIMENSION) WITH COVER � � ANC14OR-KLT_...T...E'MP_TULIAIL. INSTALL ANCHOR ... BOLT COVER s IT'JF (PROVIDED BY POLE '' :.. SIDEWALK OR I,IAP 9FACTURER? Pt.A*t'ER STPIP�. ANCHOR BOLT, 4 TCiTAL. 1 1 / 4" ! NA (TYP) " ROADWAY ` a INSTALL GROUT :•" HEX NUTS, STEEL ;6 REQ'T ' PROVIDE. I/?" DIA PER ANCHOR BOLT), r n FOR F.,UNDATi N DETAILS, SEE TH€S SHEET DRAIN TUBE THROU4GH FEAT WASHERS (6 REO'_n PER GRO:ET ANCHOR BOLT;; ANS HOP, BOT ASSEMBLY DETAIL P11" EMATM�0111�I k7mm BIWA" ARv SmaSL. a v w r I STD. PLAN — 117.1 PUBLIC WORKS � PO&t DEPARTMENT �lTAILi CMAN CREEK PUD AwrMM OF 0 94 W 94 0 n IL 916 w�nww INIM m aewrr. ��wwi Pt�,E 4>-- 0» € IM€NAIRF ARA! LENGTH) -. 2' TANGENT ! 7.,. R 13:5" . t..�. n 3:5" DIA HOLE DJAMF 7.1, BRA ,K E T _5QE._'I£ET IL' 1 R0;.1N0 CAP _ ALUMINUM SHRO11JI3 (BY MAI•+UFACTt1RERl l MANUFACTURER SHALL WELD SHR)IJD i ......._ i ALL. THE WAY ARO €N 3 LUMINAIRE ARM L UMINAME. C€UNCUT TORS > CLAMP -ON T, LIUMMA1RE DECORATIVE LUMNAIME, PUBLIC 'WORKS w� AM STD. PLAN — 117.3 DEPARTMENT amtwii�� GRAPHIC SCALE 40 0 20 40 t!0 IN F=T 1 inch = 40 !t. REFER TO WONT LOCKING LD STANDARD DUTY JUNCTKIMI 9= TYPES i & 2 STANDARD PLAN J-40.10-03 SPLICE KIITS CLEAR EPOKY of RUNS ON ALL 74RU 4" CONCRETE PAD 2' MIN. M BASK COPPER IGROUND MARE -go cwmllow.w I vwsaiwv "REW/�EN INSULATION FROM SERVICE CAMNET 2 - L0411MG SYSWIM — WNIIIES TO CONTACTON (SIZED AS REO'D.) s/swxd' COPPER CLAD GROUND ROD GENERAL NOTE 1. REFERENCING STANDARD DETAIL 117.1, CONTRACTOR TO NOTE THAT THE PEDESTRIAN LUMINAIRE MOUNTED AT 14"-0" IS NOT REQUIRED FOR THIS PROJECT. LUMINAIRE WIRES WILL K A CONTMIUOUS RUN FROM FUSE HOLDER TO FIXTURE MATH NO SPLICES. GROUND ROD TO LUMMIAME FUSE TOTS QUICK R15CON IECT 3 AMP IN LINE FUSE KITS UNMNAIRE WIRES WILL K #12 S.E.C. OR EQUAL AWG IN A JACKETED CA81" #5 MEN MlSULATED MARE To FIxTuK amou D Luc GROUND LUG 1 /4" WIVAMIIM DRAIN HOLE 2" MMI. OROUT TOP OF CONCRETE FOUNDATION TO UNDER POLE SASE � r MATH TOP OF SIDEWALK AN ; CLAMP ` I 4 S TEEM CONDUIT CONCRETE FOUNDATION 3' SO. OR DIA. NQTES: 1. EQUIPMENT GROUND WIRE do BARE WIRE SHALL BE SECURELY FASTENED TO THE GROUND LUG INSIDE THE PULE HANDHOLE. ALL BONDING & GROUNDING CONNECTIONS SHALL REMAIN ACCESSIBLE FOR INSPECTION AND MAINTENANCE. 2. IF THE FIXTURE MANUFACTURER HAS MADE PRO\MSION FOR THE ATTACHMENT OF A GROUND WIRE A GREEN INSULATED WIRE OF THE SAME SIZE SHALL BE RUN FROM THE FIXTURE TO THE GROUND LUG INSIDE THE POLE HANDHOLE. IF THE FIXTURE MANUFACTURER HAS A GROUND LUG A #$ GREEN INSULATED WIRE SHALL BE RUN FROM THE FIXTURE GROUND LUG TO THE POLE GROUND LUG. PUBIIC WORKS DEPARTMENT VPICAL #M" u Mo SYSv=M M. puff 1t• s TOES W26T ENGINEERS, INC. 2702 =M 43M SWMT WM 301 TAOOMA, MN 98400-7315 1R!'N M (253) 472-3.100 FAX (253) X3-9402 CALL 48 HOURS BEFORE YOU DIG [MAL 811 11 ;Pat _107 i z z �> ...... ...... ................ (LUMINAIRE AFM LENGTH) G 16' R 22" s C �z t� m m m D 4' OD HIOL-1 (LUMINAIRE ARM LENGTH) TO° R 30" - f `:... 4" OD HOLE ..... .... (LUMINAIRE ARM LENGTH) 457' R . 4» 00 POLE y .. (LUMINAIRE ARM LENG3TW 60' T* 46 • j. att ri DJAMF 7.1, BRA ,K E T _5QE._'I£ET IL' 1 R0;.1N0 CAP _ ALUMINUM SHRO11JI3 (BY MAI•+UFACTt1RERl l MANUFACTURER SHALL WELD SHR)IJD i ......._ i ALL. THE WAY ARO €N 3 LUMINAIRE ARM L UMINAME. C€UNCUT TORS > CLAMP -ON T, LIUMMA1RE DECORATIVE LUMNAIME, PUBLIC 'WORKS w� AM STD. PLAN — 117.3 DEPARTMENT amtwii�� GRAPHIC SCALE 40 0 20 40 t!0 IN F=T 1 inch = 40 !t. REFER TO WONT LOCKING LD STANDARD DUTY JUNCTKIMI 9= TYPES i & 2 STANDARD PLAN J-40.10-03 SPLICE KIITS CLEAR EPOKY of RUNS ON ALL 74RU 4" CONCRETE PAD 2' MIN. M BASK COPPER IGROUND MARE -go cwmllow.w I vwsaiwv "REW/�EN INSULATION FROM SERVICE CAMNET 2 - L0411MG SYSWIM — WNIIIES TO CONTACTON (SIZED AS REO'D.) s/swxd' COPPER CLAD GROUND ROD GENERAL NOTE 1. REFERENCING STANDARD DETAIL 117.1, CONTRACTOR TO NOTE THAT THE PEDESTRIAN LUMINAIRE MOUNTED AT 14"-0" IS NOT REQUIRED FOR THIS PROJECT. LUMINAIRE WIRES WILL K A CONTMIUOUS RUN FROM FUSE HOLDER TO FIXTURE MATH NO SPLICES. GROUND ROD TO LUMMIAME FUSE TOTS QUICK R15CON IECT 3 AMP IN LINE FUSE KITS UNMNAIRE WIRES WILL K #12 S.E.C. OR EQUAL AWG IN A JACKETED CA81" #5 MEN MlSULATED MARE To FIxTuK amou D Luc GROUND LUG 1 /4" WIVAMIIM DRAIN HOLE 2" MMI. OROUT TOP OF CONCRETE FOUNDATION TO UNDER POLE SASE � r MATH TOP OF SIDEWALK AN ; CLAMP ` I 4 S TEEM CONDUIT CONCRETE FOUNDATION 3' SO. OR DIA. NQTES: 1. EQUIPMENT GROUND WIRE do BARE WIRE SHALL BE SECURELY FASTENED TO THE GROUND LUG INSIDE THE PULE HANDHOLE. ALL BONDING & GROUNDING CONNECTIONS SHALL REMAIN ACCESSIBLE FOR INSPECTION AND MAINTENANCE. 2. IF THE FIXTURE MANUFACTURER HAS MADE PRO\MSION FOR THE ATTACHMENT OF A GROUND WIRE A GREEN INSULATED WIRE OF THE SAME SIZE SHALL BE RUN FROM THE FIXTURE TO THE GROUND LUG INSIDE THE POLE HANDHOLE. IF THE FIXTURE MANUFACTURER HAS A GROUND LUG A #$ GREEN INSULATED WIRE SHALL BE RUN FROM THE FIXTURE GROUND LUG TO THE POLE GROUND LUG. PUBIIC WORKS DEPARTMENT VPICAL #M" u Mo SYSv=M M. puff 1t• s TOES W26T ENGINEERS, INC. 2702 =M 43M SWMT WM 301 TAOOMA, MN 98400-7315 1R!'N M (253) 472-3.100 FAX (253) X3-9402 CALL 48 HOURS BEFORE YOU DIG [MAL 811 11 ;Pat _107 i z z G z s C �z t� m m m D i 7' a e 1 e • 0 0 d z ° • a ° _ d 3, • } O 0 e � J • a • n ° d a • � ° t • STREET LIGHT POLE PLAN VIEW JUNCTION BOX SIDE VIEW LIGHTING STANDARD & JUNCTION BOX NOTE: CLASS `B' CONCRETE TO BE USED IN CONSTRUCTION OF PAD 4" DEEP • d • ° ° • Jd t d • ♦ • d • ° d Z � a T • � d lr ^ d V • .. d PLAN VIEW INDIVIDUAL JUNCTION BOX PUBLIC WORKS CONCRETE PAD DETAILS OVED: DEPARTMENT AA TE CFELAN CREEK PUD Araenorauwww mu e�rr� err 2" TO 2-1/2' MOUNTING HEIGHT 15 FEET 1-3/4" TO 2" 2-7/8" TO 3" INSTALL DECAL NUMBERS VERTICALLY. INSTALL IN DRY WEATHER, 50' F OR ABOVE. PLAN VIEW LED TYPE WATTAGE REFLECTORIZED GOTHIC GOLD OR WHITE LEGEND ON SLACK BACKGROUND PUBLIC WORKS STREET LIGHT STANDARD �. llJif — ls1 DEPARTMENT DECAL NUINSERINC3 SYSTEM APPRUM GRAPHIC SCALE 40 0 20 40 so (INS') 1 inch = 40 it. 1 /8" IA" LOAD DIAMETER = 7/8" 4- 7/8" LINE 1 Id" V V i I I1 `, V ill V VJ CI IC'C I/ IT EPDXY FILL INLINE SPLICE r- m fllN v \/ r -ii i WYE. 5F'LIUE 1/89Y SPLICE KIT FUSE KIT & SPLICE KIT DETAILS ��. ADOPTED ' CTTY OF RENTON ♦ R- STANDARD PLANS LST DATE: 04/04 �� DWG. NAME: J013 SP PAGE: J013 T-386905 R - 386921 T1194 W16T ENGINEERS, INC. 2702 SOLM 43ND SST. 5U"E 301 TACOMA. U% 90400-731 s IRAPNOW (253) 472— FAX (253) 363—OM CALL 48 HOURS BEFORE YOU DIG DIAL 811 rl I z z m D U a a � Z < U 9T, �? < CA . I ( ww �1 1 110 U Q 494 .1 LL) tI} _j LA U _j0 a Ir :ij So 0 oui ht N N � Li D �.�• .G p QIf z 0z US C l1A1 W itiI F" a •ctixQ Letc�_ zoY 3< � , 0 O 0---0 a �14 L<Rl o ---o l i.a.O Ro 40C 0 o o---o�� U2, woo DO Z w �. -5)g oC) � UjP-\WU Y< ,M.. ao 0 } } f T # } } W } F # z } } } } p 0i l _J r- - •- A4: 40ii ' s TEST SWITCH TERMIN BLOCK STREET SIGHTING CONTACTOR CABINET WIRING SCHEMATIC TYPE III SERVICE 120 f 240 VOLT t. t-r11\LJ 1 LUMINAIRE OUND WIRING COLOR CODE A. WHITE JACKET (NEUTRAL) B. BLACK JACKET (LINE) C. GREEN JACKET (GROUND) D. RED JACKET (LOAD) E. GREEN OR BARE WIRE (GROUND) PUBLIC WORKS STREET LMIMNG CONTACTOR M. RM 123 ♦ DEPARTMENT CASPOET SCHEMATIC R Ouwff L A N C Kne rA PUD ArwnwaUwWwU Ir, wu�rw INFAVK re CONDUIT ENTR. AREA PLAN VIEW SIZE TO FIT CABINET _7L +! 6., 6" C14 - 4 d . a N , N •. a .. d. d FRONT VIEW Shim to plumb JLl- Shim to plumb See Note 3 +} #4 hoops cO-C /4 bar each corner #4 bar each corner 6" MIN 1" to 2" 1" to 2" 6C 3/8" diameter plastic drain SIDE VIEW V-6" Cabinet depth 1'-6" + 2 to SIZE TO FIT CABINET —Grade Level e e. sd . d • � d a d d SIDE VIEW SIDE VIEW V-6" Cabinet depth V-6" + 2 #4 bar each t corner ; r N Y C + a to #4 bar each corner PLAN VIEW PLAN VIEW PAD MOUNT PAD MOUNT BAT' RY RACKUP SYSTEM (BIBS) FOUMt3ADW For NOTES see Std. Plan 126.2 M. PUM PUBLIC WORKS CABINET FOUNDATION DETAILS — 128.1� � ♦ ROVE DEPARTMENT Am wlww GRAPHIC SCALE 40 0 20 40 so 1 inch = 40 1t. amm-wo d1wreier ,p,i,nMk wok (wo per "alael)-..._........ ) JLl- Shim to plumb n _ See Note 3 +{ #4 hoops o #4 bar each corner Ire. wow simian speoftwoofts. 6" MIN 1" to 2" 3/8" diameter plastic drain SIDE VIEW V-6" Cabinet depth V-6" + 2 #4 bar each t corner ; r N Y C + a to #4 bar each corner PLAN VIEW PLAN VIEW PAD MOUNT PAD MOUNT BAT' RY RACKUP SYSTEM (BIBS) FOUMt3ADW For NOTES see Std. Plan 126.2 M. PUM PUBLIC WORKS CABINET FOUNDATION DETAILS — 128.1� � ♦ ROVE DEPARTMENT Am wlww GRAPHIC SCALE 40 0 20 40 so 1 inch = 40 1t. amm-wo d1wreier ,p,i,nMk wok (wo per "alael)-..._........ ) slawalar prisrtils +.it (r+. '« aeblbe�tj .. 3 - #4 *A*% ckq Nor (ems apneas) SSW s S" Malls 3X � p 4astic . Sea Now lF C` I .. _ .. _D a__.. 4 1. tea 1aaaftili r pod 10 WOW within a 600"k cwm. *uct pod. UP 1111wh .na slid V01106 "nitUft a1400i.r top and .ills& AWL I1101AM lar be 00. 1111111 by a 01OW0.110 . ew.Meslar eek d" meet 0wrvolmirwwwAs of .section 4-141 in Ire. wow simian speoftwoofts. 2. liked it de ipr Is Miami. & Neem a v0saws well between the fewWation arra! cabinet. 4. Am**r Hila awd Mrir to. be etA1M# b0 calrlhol wwwwtedwor mod mdm* A*d to tire • ter cw4o t t_� for We to00a111er end irrtodw a d0nots *40 be bwl}id per Ow aw lraot pierrs, pis ow 2" "we ap o/ wt tW ilia 1 widellisn. 6. Cowolle sbrlN be C1110i JMO.. SW -m to Pkrnb 7. $" eerwlrtit *40 be hissed ham We cesntector to the carrtMiraEd owtuoosr/m od"Ok. --'Jas #6oft 3 8. Eselt ,o Mat shah halls a ** d meter pNitc chain pipe. 9, G,esske awWmft os W4*y Mlthiri 'tive cabinets. 41 10. 1Nhwn eN Ow cob h, are to be InsteW and eimm allows. a ces obb ed foondatisn OW be used.. s`,ow slawalar prisrtils +.it (r+. '« aeblbe�tj .. 3 - #4 *A*% ckq Nor (ems apneas) SSW s S" Malls 3X � p 4astic . Sea Now lF C` I .. _ .. _D a__.. 4 T-386906 R-386928 T226 WE 4T ENGINEERS. INC. 2M 912M 420 smKT, WIX 301 U% 964ft-7315 MM40 llE (253) 472-3300 FAX (253) M3 -9M CALL 48 HOURS BEFORE YOU DIG DIAL 811 • 3* Ln I En z z M D 1�l0. Mari=+1I�#Mti .,.:4 S Pi000e T-386906 R-386928 T226 WE 4T ENGINEERS. INC. 2M 912M 420 smKT, WIX 301 U% 964ft-7315 MM40 llE (253) 472-3300 FAX (253) M3 -9M CALL 48 HOURS BEFORE YOU DIG DIAL 811 • 3* Ln I En z z M D CKLAN CREEK PUD A OF a V4 a V4 --*I u Norwe��, wurrs �■■M�t oM comy. �■wwi _ND 0 ( POLE #) PATHWAY 42" BOLLARD, & FOUNDATION. SEE LIGHT FIXTURE OOWNED SCHEDULE FOR ADDITIONAL INFORMATION. FIXTURES TO 9E AND MAINTAINED BY THE HOMEOWNERS ASSOCIATION. PULL BOX WITH ANTI SLIP LOCKING LID. (SEE WSDOT TYPE 1 J-40.10-02 STANDARD DWGS) ® PROVIDE 1 " TACK WELDS AT BOTH ENDS OF THE J -BOX LID --'���- UNDERGROUND CONDUIT & WIRE. RUN NUMBER, SEE SHEET E2, VOLTAGE DROP CALCULATION Q & WIRING SCHEDULE FOR ADDITIONAL INFORMATION. ® SERVICE CABINET & FOUNDATION REFERENCE CITY OF RENTON STANDARD PLANS 122.1, 123 AND 126.1 i!t I f h co�. / t 19 V \ .moi/ - r - -H... - -• - - JI._. HOUSE -i- 8 1+00 4+00 GENERAL NOTE GRAPHIC SCALE 30 0 15 30 60 ( IN FM) I inch = 30 it. 1. LIGHTING FIXTURES 1-10 ARE CITY STREET LIGHTING. SEE SHEETS E1 THROUGH E6. 77 5+00 6+00 7+00 8+00 DINALL AVENUE N.E. PLAN NOTES OCONTRACTOR TO FIELD VERIFY LOCATION OF LIGHTING SERVICE CABINET AND NEAREST UTILITY 2401120V TRANSFORMER. COORDINATE ALL REQUIREMENTS AND CONNECTIONS WITH PUGET SOUND ENERGY AND CITY OF RENTON TRANSPORTATION MAINTENANCE MANAGER ERIC CU TSHALL. O2 PROVIDE NEW SKYLINE STREET LIGHTING SERVICE CABINET W1 TH CONCRETE FOUNDATION PER CITY OF RENTON STANDARDS. PROVIDE 2" CONDUIT, 3#2 WMRING AND CONNECTIONS TO 240-120 VOLT TRANSFORMER. SEE PLAN NOTE 1. OPROVIDE PULL BOX IN CONCRETE PAD AT END OF SIDEWALK AND A 2" CONDUIT ONLY AS SHOWN FOR FUTURE EXTENSION OF STREET LIGHTING. T=386907 R m 386929 TRE$ •E•T ENGINEERS, INC. 27OOR SOM 43M S711ET, SWE 301 TACOMA. VA 90190-7315 INLEM ME (253) 472-3300 FAX (253) 393-9402 CALL 48, HOURS BEFORE YOU DIG DIAL 811 C� - Ke - 'S S(o 9, 91 �17 CHELAN CREEK PUD AranwvawwYsUK 516 wins imam oN oornr. ��rr LIGHT FIXTURE SCHEDULE PATHWAY LIGHT SCHEDULE LSTREET O. PATHWAY MOUNTING HEIGHT ARM LENGTH CIRCUIT TYPE/WATT/DIST. LUMINAIRE TYPE BASE COMMENTS RU O TRACT 'E' 42" N/A 1 LED/33W/TYPE V SEE FIXTURE SCHEDULE THIS SHEET FIXED LED BOLLARD LIGHT FIXTURE SCHEDULE DOTANCE LOCATION OF LUMINAIRE MANUFACTURER PATHWAY ARCHITECTURAL AREA LIGHTING LUMINAIRE: UCB—LUM—FLR-12LE0—WW—RAL 9005TXOTN43 (QRS) DROP UT,�7�[HK�L�UI►9IJ�Z�L•1��1�1�31I�Il�PA TH WA Y LIGH 7ING T/1GE DROP CALCtJLATpN � row AWAcrnr AWEREa iR 20 VOLTS _1 RUN N0. DOTANCE CURRENT VOLTS CONDUCTORS (FEET) (QRS) DROP CIl�lCl#L"T 1 NO. 18 ® 2" 0.00 19 40 9.38 0.49 20 40 5.18 0.27 21 40 5.04 0.28 22 40 4.90 0.26 23 40 4.76 0.25 24 40 4.62 0.24 2#6, 1 X18 GR 1 ILLUMINATION © 26 40 4.34 0.23 27 40 4.20 0.22 28 40 4.06 0.21 29 40 3.92 0.21 30 40 3.78 0.20 31 40 3.64 0.19 .32 40 3.50 0.18 33 40 3.36 0.18 34 40 3.22 0.17 35 40 3.08 _ 0.16 361. 40 2.94 0.15 37 40 2.80 0.15 38 40 2.66 0.14 39 40 2.52 0.13 40 40 2.38 0.12 41 40 2.24 0.12 42 40 2.10 0.11 43 40 1.96 0.10 44 40 1.82 0.10 45 40 1.68 0.09 46 40 1.54 0.08 47 _ _ 40 1.40 0.07 48 40 1.26 0.07 49 60 0.28 0.02 50 35 0.14 _ 0.01 51 40 0.84 0.04 52 40 0.70 0.04 53 40 0556 0.03 54 40 0.42 0.02 55 40 0.28 0.01 56 40 0.14 0.01 TOTAL. 1535 2" 5.97 2.32% @M VOLTS GRAPHIC SCALE 40 0 20 40 so (INr' ') 1 inch = 40 ft. PATHWAY CONDUI T MRING SCHEDULE RUN NO. SCHEDULE 40/80 PVC CONDUIT CONDUCTORS CIRCUIT REMARKS SIZE LENGTH NO. ® 2" — 3#2, 1 #2 GR — UTILITY CONNECTION ® 2" 40 LF 2#6, 1 #8 GR 1 ILLUMINATION ® 2" 40 LF 2#8, 1 #8 GR 1 ILLUMINATION © " 2 40 LF 2#6, 1 #8 GR 1 ILLUMINATION © 2" 40 LF 2#6, 1 X18 GR 1 ILLUMINATION © 2" 40 LF 2#6, 1#8 GR 1 ILLUMINATION ® 2" 40 LF 2#6, 1 #6 GR 1 ILLUMINATION A2" 40 LF 216, 1#8 GR 1 ILLUMINATION ® " 2 40 LF 216, 1 #8 GR 1 ILLUMINATION © 2" 40 LF 2#6, 1 #6 GR 1 ILLUMINATION ® 2" 40 LF 2#6, 1 #6 GR 1 ILLUMINATION A2"40 LF 2#6, 1 X16 GR 1 ILLUMINATION ® 2" 40 LF 2#8, 1 #8 GR 1 ILLUMINATION © 2" 40 LF 2#8, 1 #6 GR 1 ILLUMINATION © 2" 40 LF 2#8, 1 #8 GR 1 ILLUMINATION © 2" 40 LF 2#8, 1 #6 GR 1 ILLUMINATION ® 2" 40 LF 2#8, 1 #8 GR 1 ILLUMINATION ® 2" 40 LF 2#8, 1 #8 GR 1 ILLUMINATION ® 2" 40 LF 2#3, 1 #8 GR 1 ILLUMINATION ©" 2 40 LF 23, 1 #8 GR 1 ILLUMINATION ® 2 " 40 LF 2#6, 1#6 GR 1 ILLUMINATION ® 2" 40 LF 2#8, 1X16 GR 1 ILLUMINATION ® 2" 40 LF 2#6, 1 #8 GR 1 ILLUMINATION 4© 2" 40 LF 2#3, 1 #6 GR 1 ILLUMINATION © " 2 40 LF 2#8, 1 #6 GR 1 ILLUMINATION © 2" 40 LF 2#8, 1 #8 GR 1 ILLUMINATION ® 2" 40 LF 2#3, 1 #6 GR 1 ILLUMINATION ® 2" 40 LF 2#8, 1 #6 GR 1 ILLUMINATION ® 2" 40 LF 2#8, 1 #8 GR 1 ILLUMINATION ® 2" 40 LF 2#8, 1 #6 GR 1 ILLUMINATION ® 2" 40 LF 2#8, 1 #6 GR 1 ILLUMINATION ® 2" 60 LF 2#6, 1#8 GR 1 ILLUMINATION ® 2" 35 LF 2#8, 1 #8 GR 1 ILLUMINATION © 2" 40 LF 2#8, 1#8 GR 1 ILLUMINATION © 2" 40 LF 2#8, 1 #6 GR 1 ILLUMINATION © 2" 40 LF 2#8, 1 #8 GR 1 ILLUMINATION ® 2" 40 LF 2#8, 1 #8 GR 1 ILLUMINATION ® 2" 40 LF 2#8, 1 #8 GR 1 ILLUMINATION 2 40 LF 2#6, 1#6 GR 1 ILLUMINATION 386908 1 386930 TONS WEST ENGINEERS, INC. 2702 90U1N 4210 SWIET, SUM 391 TAt10 W VA $0400-7315 1111UPOW (363) 472 - FAX (253) 363-9402 CALL 48 HOURS BEFORE YOU DIG DIAL 811 YZ - 7m�;' W& 1-7 % 0