Loading...
HomeMy WebLinkAboutR-388318C m C Cn Match Line - See Sheet C4.02 \ I I 21.58 _ ` 2266F \ 4" PERIMETER \ \\ I I 4" PERIMETER FOOTING DRAIN FOOTING DRAIN SEE DETAILCIO \ I o I SEE DETAIL C4.1� 22.60 T • C4.11 \ U U 1I" \ 6 fie° Building"C' 1 \ \ I - 2292 C 6" SDCO 2170 CONNECT FOOTING DRAIN FF= 23.00 RIM TO GRADE \ i TO STORM SYSTEM IE=17.23 \ \ U U SEE DETAIL IE=17.24 \ I 23 -s1�1 C4.11 SD#F2B AREA DRAIN 5 LF 6" SD @ 10.3% '�3.30 N:170180.87 E:1293209.44 6" STORM POC U 2C AREA DRAIN /IRIM=22.50 1 138.47 E:1293192.45 IE=18.25 6"(IN)S IE=17.60 23.86 0 - SEE MECH'L PLANS SD#G I CB TYPE 1 v 22.35 UI - 1 6" I W IE=19.98 6 (IN)SEPVC FOR CONTINUATION- N:170051.52 E:1293202. 7 IE=18.25 6 (OUT)E SD#F2E RIM=20.71 0 3. 7 _ - \ 23.94 � R IE=17.16 12 (IN)W � � 9 \ ...: -----91j ---- 01 01 o - IE=17.16 12„ (OUT)E 24os1 23.86 2 4S (F 22.02 I 2 SEE DETAIL 6" 5 --- --- 1T----�1�-- �- :<l ---. -- 1�-- -���- = - 1 NEP 0.93 (TYP) I o�-10 �` w 3.97 S� Q2•�� AREA DRAIN 22 N 2 22/4 23.13 11.18 # 219 AREA DRAI i 22.9 O 12.80 5 22.90 2214 21.58 23.25 23.25 N:17 99 E:12 235. 0 i 23.0 2.90 22.90 i 1 22. 8 SD#F3 CB TYPE I 48" __rr N:170093.58 E:12 3238.65 RIM=22.68 0 IE=12.99 18"(IN)SE IE=17.63 6"(IN)E IE=12.99 18"(OUT N 21.75 SEE DETAIL 6 J \ I I I I U U U \ U \ \ U \\U U \ w 22.46 I C 22.66 I 22.47 U I U I " I I I I I " I U I U II HIGH PNT 22.20 I'i N I p � N 22.21 I p I I I � ` 5 #F 1 C N. 7026 . 2 E:1 27. RI =22. IE 11.4 18"(IN)S .2 3.00 22.90 RIM=22.96 I -17. 6"(IN)S r _ 21.07 .08 2.4 .25 23.17 IE=20.95 6 (0 - T' 1. % DS 2 .ss ,�, =19 4-(IN 21.13 22.48 2 23.17 AREA DRAIN 23.2 23.1 22. 7 5�9� IE = 7 4"(I S V 22.11 • 23.17 23.25 23.16 3. 23. „ D IE 1. 2 18 (0 )NE 21.65 1.0% __ ._ 1. 18 2 . 6 22.5 23.1723.17 21.25 21.86 23.25 23.250 23.17; 22.9 23.17 21.77 89 LF 18"SD 00.9% 23.17 ­7, 23 D-17 23 1 D# 2 CB T E 48" 1 :1 0189 99 1 40.55 ` ` 23.25 1 K, IM 23. 2. 23.25 -17 23.35 ' `� = 2 18' S 6 3 2 .30 1 2 42 "(IN)E ?6 2. ® IE T 6 W 23. 23, 4> 23 .63 IE 1 1 U -� T S 2 2 802 30 2¢ C�_ 0z 11 IE=21. N 23.2 i 0 N �j\8 LF 4 - No zssi I_�r� L _ ® 4 4 2 21.35 1 23.2 23.76 \I_ i SD#F4 CB TYPE II.48A 2 14 •39 23:65 11 I .170045.68 E:1293 04.0 RIM=21.17 . - 23.24 1 FTG---- FTG ---- FTG---- FTG- IE=16.4012"(IN)W 23.14 �- IE=14.23 12"(IN)E J i-FTG ---FTG-=--FTC - IE=13.73 18MOUT)N 23.22 SEE DETAIL 23.' 23_62 i 23.70IV i R( 23.80 i C( i 23.65 N 3.87 23.90 3O I 24.00 24.00'4 ---FTG-- TG- - FTG�Sr (nP) C4.1 0 23.14 OVERHEAD PEDESTRIAN CANOPY- 22.50 .'girtSEE ARCH L PLANS FOR DETAILS 23.12 SD#F3A AREA DRAIN TG-1 N:170112.69 E:12933 2.80 3.11 RIM=22.90 IE=19.55 6"(IN)E I 01E=19.55 6"(OUT)W ° CONNECT FOOTING DRAIN TO STORM SYSTEM T I _ SEE DETAIL 22.50 - C4.11 I I 4" PERIMETER I 3.12 T FOOTING DRAIN CID i I SEE DETAIL SD#F5 CB TYPE II 48" 82 23.25 Sp O6 �O��o 0 90 ®4 69 93 16 229 23.00 i 2.84 y�23.24 2.92 21.9 �5D#FIACBTYPE I 111:170204.08 E:1293 58.62 I_4IM=22.90 ' I�-19.93 4"(IN)E + i g SD#Z CB YPE II - 54" -/ I�-21.08 4"(IN)S , N:170 13. 9 E:1293249.5 23.39 IF=21.64 4"(IN)E 23.30 RIM= 2.0 0 „ N I IE=8. 0 2 "(IN)E 2 I IE=8. 0 1 "(IN)SW IE=19.12 6"(OUT)NW W I IE-8. 0 2 "(IN)W Q I - o " ��o I IE=8. 0 2 "(OUT)N ANTI SEEP COLLAR i_ _ (TYP ON PERF END) AF filiIIIIIIIIIIIIIIIII HIGH PNT 23.56 DOWNSPOUT ® 23.56 - _65 CTION - SEE ARCH?o 1.I 2 .45 TYP 4 CONNECTIONS 19LF4"SD@2.0% 4' SE CO .90 4" SDCO RIVTD GRA E IE=21.67RIM TO GRADE. ��► IE=21.67 L23.71 23.52 G---- FTG ---- FTG----F J 22.62 22.67 23.91 --- FTG----FT SD#H I CB TYPE 11- 48" N:170307.33 E:1293366. 1 \ -4 IM=21.36 1 =9.25 24"(IIN I I Tc 22.80 22.80 In Compliance W/ City Of Renton Standards BC 22.3o II Approved By: Date: /I I Approved By: Date: 1 I I Approved By: Date: I �I Approved By: Date: 2 30 2.I CONSTRUCTION RECORD DRAWING 1 0 . This construction record is a copy of a CAD file prepared by COUGHLIN PORTER LUNDEEN and has been entitled to reflect field verified invert and rim elevations SD#J I CB YP II 48' of the storm, sanitary sewer and water main systems. Field verified invert and rim elevations were obtained by RYAN COMPANIES US, INC in July 2017. N:17 306. 6 :1 93 0 68 1 COUGHLIN PORTER LUNDEEN, INC does not provide any warrantee as to the RIIM9 1 2 "(I )W I accuracy or completeness of such information provided by others. IE=IE=1 i.03 "(1 )S I I -14.50 6 (I )S I, IE=9.25T)W 5 LF 6" SD @ 2.07022.84 3 o I S ®l• � \ � y 6" STORM POC IE=18.75 I� SEE MECHT PLANS FOR CONTINUATION I 6" SDCO I 1 G4. RIM TO GRADE < ' N:170040.80 E:1293406. RIM-21.43 IE=18.65 02 LF 24" D ® 0.8% 1 =15.25 12 (IN)E IE=18.65 I SEE DETAIL 10 I -15.25 12 (OUT)W (TYP) �4. 10 1 #L84 9 /"�.5s 22.16 22.50 0 a I 23.12 C7 SD#F3B AREA DRAIN HIGH PNT N:170102.74 E:1293404.62 5 22.49 23.12 L RIM=22.75 IE=20.15 6"(IN)E 22 s4 2.5s j IE=20.15 6"(OUT)W 4" PERIMETER SEE DETAIL 12 FOOTING DRAIN y (TYP) c 10 SEE DETAIL L I C4.11 f2*14 2313 Building 'D' / \ 0 2 620 FF= 24.00 ji b 2 62 I L 6" SDCO \ ®h� RIM TO GRADE `' p SD#F3C AREA DRAIN IE=18.65 IE=18.65 N:170096.16 E:1293516.75 2.84 RIM=22.92 6 STORM POC IE=21.00 3„ ( IE=18.75 jL J IE=21.00 6"(OUTOUT)W SEE MECHT PLANS FOR CONTINUATION 662 23 LF 3" STORM POC 23.12 SD @ 24 07« IE=21.46 SEE MECH'L PLANS 5 LF 6" SD @ 22.58 o CID FOR CONTINUATION w 22.49 Match Line - See Sheet C4.04 9 5 2 "( UT) __ 2280 3 CONTRACTOR TO 0NTAC SPU I Call before you 22 TRANSMISSION CREW CHIEF ROGER I COX: (206) 399-2496 W TH A MIN I 72 HOURS INOTI E PRIOR TO D 8- I -1 BORING COfvSTR CTION. 4N SPU • REPRESENTAINE SHALL ON SITE I DURING ALIT WORK WITHITSPU U Or I-800-424-5555 PROPERTY. I 4-J UNDERGROUND �218 N SERVICE (USA) r �I LIMIT o I V) 0 10 20 40 Cn 1�1 I LF 24" SD1l- 0 % c%i SCALE 1"-20' 1 I lowin lI W II-1, 11 J I I � �s 20.75 V U CD _ I�III I I I I I I I MI I11 Frl 1 r- Z O m I I o r l I I 21 4 TITLE LONGACRES BUSINESS CENTER SW 27TH SIT & NACHES AVE SW CONSULTANT COUGHLIN PORTER LUNDEEN 801 SECOND AVENUE - SUITE 900 SEATTLE, WA 98104 P: 206/343-0460 F: 206/343-5691 A CONSULTING STRUCTURAL AND CIVIL ENGINEERING CORPORATION ISSUED: DATE DESCRIPTION 03/09/2016 BUILDING PERMIT RESUBMITTAL 05/04/2017 NW CORNER UPDATE 07/17/2017 AS -BUILT SET 03/15/2016 CSK-002 1 I NOTE: 04/19/2016 CSK-005 CMU Footing Storm Conflict F- I I SET ALL DRAINAGE GRATES 0.1 FT BELOW FINISH II i I LANDSCAPE GRADE wu .o _ I KEY MAP: NOTE: ALL STORM PIPE (SD) TO BE LCPE, RCP, SDR35 1 I I I (IF GREATER THAN 3'). ALL STORM PIPE TO 221 (I CONFORM WITH CITY OF RENTON STDS I c��II II I NOTE: ALL SPOTS SHOWN ARE BOTTOM OF CURB ELEV. li ALL CURBS ARE TO BE 6" CURBS UNLESS OTHERWISE SPECIFIED. I I ( 1 1 Legend 1 1 m 1 1 I 1 EXISTING REMOVE PROPOSED RIGHT OF WAY - - - PROJECT NUMBER 2 .55 \ I I PARCEL LINE DRAWN BY \ III ASPHALT PAVING ISSUE DATE CULVERT, 11F bI I CONCRETE PAVING / IE E END 2 1 ® E w END 1 .TQ \ / BUILDINGS SEAL GRAVEL DAL PE m of ROCKERY Q99 ti CURBING C� I 1 CONSTRUCTION LIMITS LIMIT SD#H2 CB TYPE III .48" I r0 �O� 36936 GIS-F N:170302.5p E:1 M468. 3 WATER LINE W ONAL S RIM=21.36 IE10 57 1 " IN C152268-03 SAS 05/04/2017 = • � ( )L I STORM DRAINAGE LINE --SD 01 IE=14.50 61(IN)SF �I I IE=10.07 2� (OUT)W I SANITARY SEWER LINE --SS SHEET TITLE /NUMBER OI I I r- I i POWER P P- TELEPHONE LINE T T_ Grading and Drainage I I 1\ o GAS LINE G G Plan o 22.42 TREE WATER METER/FH Ell t /I M STORM CB/MH L _J ® • �,% 0 SEWER MH/CO 0 OO / r/ / / GAS VALVE/METER 9 0 b � u' i X I C4003 STREET LIGHT � o-❑ R-388318