Loading...
HomeMy WebLinkAboutORD 1077� , � ._ '� ,; �' ` . ._..�• .,. � i ' �� / , ORDTNkNC�; IdO. � �� � ' AN ORllTNAIVCE R�EGUL::TING TH� TJSE, H��jDL1i�rG,. STOR�GE AT�D S�iLE ` OF FLt=�y���BLE LI�UIDS IN THE CITY OF R�dTU�V, VJnSHIi�IGTON, P1�O�TIDING ' h P�'���LTY FOR THE V?QL�aTTOiU HE.��EOF �ND REPEALING OR�IN�.NC� N0. 414, PASSL;fl .�Lt�JD xPPRGS7ED i�10VEiVIBER �3; 1915. I'� The City Council of the� City of Ren�on .�o Ordain a.s Follows: CHkPT�P. I. SECTTON 1. This ordina�eQ shall apply to all nev� plants, stores, e�uipments and instal�ations; and, except as oth�rv�lise specified, to existing pla.nts, stores, e�uipmen�s, and installations rahich constitute a distinct hazard to adjoining �rop2rty, in so far as the int�nt of the s�ctions can be reasonably fulfilled. pll persons ana business storing, handling or using flamrlabl.� liaui�s shall be governed by this ordinance ���hether or not specifically � named in this ordina�ce. SECTIQN 2. For ths purpose of this ord'inance, flammabl� li��aids are divided into three classes, accordi.ng to the flash point, as follows: Class l. LiGuids vvitn flash point below �5 deg. Fahrenheit (4 d.egrees Ce�tigrade) closed cup tester. Class ;. Licuids with flash point above that for Class l, and belo��� 70 degrees Fahrenheit (�l de�rees Centigrade) clos�d cup tester. Class �� Licuids u�ith flash point above that for Class 2, ' and belo�^r : 18? degrees Fahrenheit (93 aegrees Centigrade) closed cup tester. . � The flash point sh�.11 be as dst�rmzned with the Elliott, , Abel, hbel-Pen.���y, or the Tag closed cup testers, but the Ta� , . , , � / � , -1- � � _ __ _ . ! � � • • • • r ` • " ' , •' ' i closed c�:p t�ster (standarciized by the United States Bureau of Standards) shall be autharitative in case of dispute. kll t�sts shall be made in a.cco�d�.nce v�lith the r��ethods aaopte� by the American Society of Testing Ntateriuls. , Re�resentative ex�mples oz" the cl�.sses ef Flammable Li�uids �re: Cla.ss l. Ether� Carbon Bisulphide, Gasoline, i�a.ptha, B�nzol, Collo�3on, Licuified Petroleu� G�,s, :�cetone. Class 2. xlcohol, �+r�yl .�Lcet�te, Toluol, �thyl Acet�:t�, �i2gthyl xcetate. , � Class 3. Kerosene, _ Amyl Alcohol, Tvrpentine, Fuel Cil. • SECTI0�1 3. l�ny ma.nufactured liuuid or fluid comr�odity, such as p�.int, v�.rnish, dryer, cle�ning solution, and polishing licvia v�hich contains fl3m.mable lic�uids shall be consider•ea a flamm��.ble licuid and shall be classed by Section 2 according to the flash point of the r�ixture. SECTTON 4. � container shall be any can, bucket, barrel, tank or. atner vessel, except stotionar�T or fixed t�:�nks, tank vr�,gons and tank cars, in v�hi.ch ilam�able Iicui.ds or mixtu.res are storea or kept. ' SECTION 5. h permit is the v�rritten a�.ztherity of thp Chief of the Fire Dep�.rtr�ent, issuea pursva.nt to this ord.ir��.nce, f'or th� manuiacture, tr��.nsport�tior�, sale or use of anf finished or uniinished pradLet or article covPred by this ordinanc� or an,y m�terial entering i.nto the cor�position thereof. SEi�TIGI� 6. nn ap�orovaZ �s a v�rri��en si,�.tement issuec� by � the Crief' of the Fire �epartr:ent, certifying that the ty�e, class or kind of article ox triing r�:entioned therein has been eya�ined and approved by the Chief af the Fire �epart�t�ent in conformity -2- � ' ,4 . , • . , • , •• tv�,th this orainance, a.nd that it is authorizeci to be ma_nufactured, stared, tr�.nsported, sold or us�d in the City of Renton. SECTION 7. The term �!Chzef of the Fire Dep�.rtrnent, �� sh�.11 include �,ny officer, member or ins�ector of the Fire Depart- ment especially deputized by the Cn�.�f oi the Fire Department to act for hirrc. ' SECTTON 8. By retail s�ore shall be meant a store or other builain.�; in ��rhich fla.mmable ii�ui�s �.re sold direct to consumers. SECTIGzd 9. By jobber shall be meant a person, firm or ' corporatian selling fl�.m.�.able licvids at u�holesale. SECTI4N 10. By a pain�t �.nd oil store sh�.11 be mear�t a store or buildirig in �hich are store�., handled. and sold at r�tail, paints, v�.rni shes, oiZs an�. fl�.rnrnable li�uid.s, alone or v�rith the appu.rtenance� necessa.ry to such matex ic.l. SECTIQI�I 11. By painter shall be meant a. pers�n, firffi or corpar��tion hanaling and mixing paints, v�rnishes, oils and other flamr��ble lic�uids �o be used by himse_i or his employ�es on premises other than those controlled by him. SECTTOi� l�. By manufacturing plznt is meant �.ny factcry or establishment in tnrhich people are employe� in the han�.ing, in process of r�anufacture, of fl�,mrriable Iicuids in ather than � original sealed containers, in �ixing or compovnding of ilammable licuids or in using of a flamnlable licuid in �he manufacture or pro�uction of any article. (���hen the use, storing or rand.ling of flanmable li�uids i.n such a mann�r as to permit the escape � of fl��r�imable vz.por i.s entirely v�ithin fire-resistive rooms, v�ith � E no openings to any other p�rt of the builcling and �°�ith v�,ind.ati��s e�uipped c�ith �R�ire� gl�.ss ana. mQtallic fr�.mes ar�d arranged to close automatically in case of fire, the rer�aincter of the building sh�.11 not be included under the term, �danufa.cturing Plant.) -3- , ; ' . r SECTIG�1 13. Exce�t as spec.;.iied in �ection lv, a permit (vJhich sha11 be ior one �r bo�h of the follov�ing sub-divisions) shdll be obtained: • ; (a) For th.e storage or hanaling of a total �uG.r,.ti ty of Class T li�uids in Excess of one gallon in any dwel'li.ng, ap�.rt- ment house or tenement, and i.n excess of six gallons in any other building, and in excess of ten gallons outside of a.ny building. (b) For the storage or handling of a total cuantity of Class II liGuids in excess of five ga.11ons in any C��rJel�j,l�.�� ap��rtment hause or tenernent, and in e�cess of ten g�.11or�s in any other building, and in excess of t�:enty-five gallons out- side of any buil�.ing. (c) For the storaoe or handli.ng of a total �uantity of Class TII licuias in excess of tvventy-five gallons insic�e any buildir�g, and in excess of fifty-five gallons outside of any building. • SECTTOI�I 14. Unless a stor2�ge of cuantities in excess of. tnose given in Section 13 is to be maintained for at Iea.st thirty days� notring in this ordi,nance shall re�uire an ov:ner ar occupant or 'rlis agent to obtain a permit for the use of, ner does it �rohibit the use by him of paints, oils, v�.rnishes and similar flammable mixtur�s. SECTIGIv 15. Al1 applic�tions for permits to sell or store flammable liCuids shal.l be made in �rriting to the Chief of the Fire Dep�.rtnient. The Chief of the Fire Dep�.rtment shaTl fortY�- �rTi�h m�.ke an inspection of the premises proposed to be used for such sale or stora.ge, and the means of distributifln, and if the conditions, surrovndings and arrangements are in his opinion such that the intent of this ordinance cG.n be abserved, then -4- � S he shdll issue a permit. SECTION 16. All permits sh�,ll state the n�.ture of tre business cf tre applicant, the maxa.mum Cuantity of each class of Iicuid to be kept,and the Iocation of the storage. Permits shall be listed as follows: G�.rage Permit (v���th or v+ri,thout storage) Storage Perrait. Retail DealGrts P ermit. Paintprts Permit. Paint and Oil Dealer� s Perr�it. Jobber� s Permit. I��r_ufacturer� s Permi.t. Dry Cleaner� s Permit. SECTTOl� 17. A painter' s permit shall include the use of flarnm.able li�vids on premises other than those controlled by hir�, but shall nat permit the selling of flammable Ii�uids v:ithout G retailer� s permit. SECTTON 18. Before any installation is cavered from sight, a notification in ���ri.ting snall be given �he Chief of the Fire �epartment, who shall, within 48 hours after the receipt of such notification, inspect the installation and give his v�ritten approv�.l or dis�pproval. Upon faa.lure of the Chiefi of the Fire Depart�.erit to inspect v�7ithin the specified time, the installation may be covered but shall be subjpct to inspection by the Chief of the Fire Departm_ent at the expense of tY�e city. SECTIOI�T 19. The Chief Qi the Fire Departmsnt shall have poti�rer to r�odify any of the �rovisions of this ordinance upon application in writing by the o�vner or lessee, or his duly , difficulties ir the a�thorized a ent ��hen there are practical g � - _�_ way vf carryin� out the strict letter of this ordinance provided I that the spirit of �his ordinance shall be observed, public safety secured, and substant��l justice done. The particulars of such modifi�atio� when granted or allovaed and the decisian of the Chief of the Fire Department thereon shull b� entered upo� the records of the department and a signed copy shall be furnished the appTicant. SECTION 20. �ithin ten days after written notification I by the Chief of th� Fire Dep�rt�lent to the oti�rn�r or occupant to correct or remedy ar�y hazardaus condition, an appeal, stating specifically the �uest�.ons which the appellant desires to have passed upon, r,�Qy be taken. Such appeals shall b� heard by a com�i�tee ccnsisting of one �ember appointEd by the Chief of the Fire Dep�-rtment, one by the appellant and a third by the two members appointed as aforesaid. The members of the committee I', shall take the usual oath of office and are aUthorized to ta.ke �, testimony �nd to grant or reject such zppeal, �ub�ect to reveiw by the proper cov.rt. SECTION 21. This ordinance shall apply in all parts to ''� all flammable liau3ds of Classes, I� SS, �,r,rid TIT� provi�.ed th�t: !' Petroleum shall. be regulated only in accordance with Chapters I� I, IIT, IV and V. Paints �.nd Varnishes only i� accordance v��,th Chapters I and VI. Garages and Dry Cleaning only in accordance v�i.th Chapter I � �.nd sections, 40� �1� 42� 43� 44� 46� 50� 51� 52� 55� 56� 57� 60, 61�, 63, 64, 65 and 66. -6- CHt�PT�R II G��EP��L PtECUSRE�II�ITS FaR THE STORAGE, �SE 1-�I� H1il�?I�IrjG OF FL�VI- �ABLF LI�UIDS. SECTTaD1 22. The Chief of the Fire Department r�ay prohibit the use of any type, kind or make oP heating or lighting appliances using fl.ammable li�u.ids which, after test by hin or some competent authority, is considered a hazard to life or proper•ty. SECTIGN 23. No Class I nor Class II li�uids sha11 be ke�t or stored in any schaolhouse, religious, a.musemcnt or other build3ng used for public assembly. SECTION 24. Except in sealed cantainers, r�o Class T nor Class II licuids may be stored within 10 feet of any stair��ay, elevator or exit. SECTTON 25. In paint or oi� stores, retail stores and � �obber' s plants containin� flam.mable licuids, a.t least tvEo �I exits sha.11 be prQvided, one of which srall be remote from the �� point af storage. I SECTIQN 26. The aixing, stor�.rl� or handling of f1�.mmable ii�uids of Class I and II in open cont�.iners, is prohibited in any store in any buildin.g housing more than t�o families or in a frame building housing more than one family, prov�.ded that this shall not apply to drug stores, �here fl.ammable li�uids are used in making and compQunding medieines and prescrigtions. SECTION 27. The storage of flammab3e Iic�u�.c�s inside bu:i.ldings except in buildings so used at the time this ordinar}ce takes effect shall be as �ivEn under the follovaing sub-sections; provided that in a special storage room or fire-resisti.vE bu.�.Iding, con- forming to re�u�.rements giver� in Section 29, an unlimited c�uantity �.ay be maintained therein, except of Class I J.ic���.ds: a. Within the limits given in Section 45. _►�_ I � I � . � . , . � � - ' , In frame builaings: Classes I and II prohibited. Class III, �i�,ximum limit o� any ta.nk or cantainer 60 gallons,; � except as permitted in Sectian 54. In otrer than frame buildin�s: Class T2. Tn sealed containers or saiety cans of not more than 5 gallons capacity and in barrels, drums or tanks of not more than 60 gallons capacity. (Total cuan.tity stored in this manner unlimi ted.) ' Class T . In sealed containers or safety cans af not more tha.n 1 gallon capacity, and not exceeding a total o� 10 gallons. Cla.ss III. In sealed conta,iners of not more than 5 gallons capacity, in barrels and drums and in tanks not excee�.ing 1�0 gallons capacity, except as permitted in Sec�ion 54. (Total cuantity stored in this manner unlimited.) , b. Outside the limits given 3.n Sectian 45. In frame buildin�s: ' Class T . In sealed containers or saiety cans of not more th�.n 1 gallon capacity, and not exceeding a total of 10 gallons. Class IT. �n sealed cont�.iners of not more than 5 gallons cap�.city and in barrels, drums or tanks not exceeding 60 gallons capacity. (Total Guanti�;y stored in th:is ma,nner unlimited.) C1ass III . In sealed cont�iners not exceedin� 5 gallons capacity, in barrels and drUms and in tanks not exceeding 120 gallons cap�.city, e�cept as permitted in Section 54. (Total Guantity stored in this m�nner unlinlited.) I In Qther than fra�e buildings: Class I . Not exceeding 50 gallons in sealed cont�.iners or safety can of_ not more than 1 gallon capaci•ty. C�ass ZI. Tn sealed conta.iners or safety cans of not more -8- , than 5 gallons capacity, in drums and bdrrels and in tanks not exceeding 120 gallons capacity. �otal �ua.ntity stored in thisf manner unlimited.) . Class III. Tn sealed coritainers, drums and barrels and in tax�Ys r�ot exceeding �40 g�llons capacity, except as permitted in Section 54. (Total �uantity stored in this manner un.limited..) SECTIGN 28. In buildings �r_aw used for storz.ge of flammable li�uid, the storage (except in special room as given ir Section 29) shall not eyceed double cuantity speciiied in Section 27. (Capacity i of individual tanks or containers may be double that spaciiied in Section 2'7.) . SECTTC�N 29. Speci�.l rooms or buildin�;s for storage of flarsmable licuids and the handling and use of flannable li�uids shall, where called far by other Sections of this ordinance, be constrtzcted as follatvs: VVa1Is, floors �.nd ceil�ngs shal? be of eight inches of brick or concretP, or af fovr inches of � reinforced concrete; door openings to other rooms or buildings sha1l be proviaed v�ith sills raised six inches a.nd with fire doors v��ith heat releasing devices arranged ta c3ose doors auto- matically in case oi fire; �vindows shall be tin;ired glass in metallic sash and fr�.mes; no combUstible rriateri�.l shall be used in construction, except that flcor surfacing �iay be of v�ood; proper ventilation shall be provided; there sh�.11 be no opening to rooms belo�T,r, except as made necess�.ry by trade or manufacturing ; process, and openings to roons and other parts of buil_ding above shall be provided �rith fire doors or trap doors v��ith heat releasing devices arran.ged to c1Qse doors autamatically in case of fire. SECTION 30. Except where kept in sealed containers, Class T • li��zids sha11 be kept in star�,ge tanks unaerground or ovtside the bu.ildin� �.nd no discharge system shall h�,ve outlet inside -9- building unless in a special room in accordance �ith SectiQn 29. Safety cans of not over one gallon capacity may be used in any part of the building. S�fety cans of over ten gallons capacity, may be kept and used i� special rooms in accordance with Section 29. In manufacturing plants, the Chief of the Fire Department may permit the storage of Class I liGuids in portable wheeled � tanks as described in Section 43, where the nature of the business l • recuires such storage G.nd the discharge therefrom. Such wheeled tanks shall be used only in special. rooms or �uild3.ngs �.n accQrdance � with Sect�.on 29. CHAPTER SII SECTTGN 31. No container . containing Cl�ss TI liGuids �.nd of over five gallons capacity may be used to fill other containers and applia.nces unless outside the building or in a special room in accordance with Section �9, and alI drav�ring except from safety' � cans, shall, where the nature of the li�uid germits, be as provided , for 3.n Sections 66 and 67. S�CTION 32. Any building, other than a frame building, within '� the limits given in Section 45, containir�g more than 500 gallons ' of flammable liGuids in other tha.n sealed containers, shall have alI windows i.n side and rear �ralls and �.bo�re the first floor on i street fronts� exposed by other buildings vaithin �ifty feet, provided with wired glass in metallic sash and frame. SECTI(�I� 33. Any ma.�ufactu.ring plant established after date of enactment of this ordinance in a building 3.n vYThich persons are ' employed above the secand story, shall have all rooms, in v�hich Cls.ss T a�d II liuuids are mixed or stored in receptacles per- mitting escape of vapor, constructed in accordance v�rith Secti.on 29. -1G- SECTION �4. Tn e�isting manufacturin� plants �There persons are employed above the second floor, �11 elevutor, stair ana other. �vells or vertical openings cort�unicating to rooms in v�rhicr� Class I and IT liruids are mix_ed or stored in receptacles per- mitting escape of vapor, shal.l be enclosed ana provi.d�d with self-closi.ng fire doors, or fire doors or trap doors v4ith heat releasing devices arranged to close doors automatically in case of fire. , SECTIOIv 35. No manufacturing plant shall be lacated in any build3r.g used as a dvrelling for more than one family unless all Class I �_i�uids are kept in safety cans, not exceeding one �u�rt in capacity, or in autside star�.ge tanks as given in Chapter IIT, Yvith no discha.rge inside the bvildin�. S�CTION 36. Kettles, v�ts, satur�.tars and othLr vessels used in manufacturing processes, and containing more thdn five , g�llons of flammable liGui�, shall not be Iocated v�=ithin five feet of cor�bustible �aterial nor vvithin five feet of any exit, unl.ess tvro or more exits are provided, and all combustible iloor there�under �rJithin a radius of ten feet shall be protecte� cv�ith non-combustible cc�vering. All kettles and other open vessels shall be provided ;a�rith substantial covers orranged to close , autamatically in ca�e of fire or urhich can be easily and readily placed in position. : SECTION ,37. Rooms in d�hich C1ass I and II li�uids are used in op�n vats, pans or other vessels, or in i�zhich Classes ; I, TT and II1 lic�?ids are heated or oth�rtlrise treated in such manner as to produce flammable vapor, shal.l be v�ell ventilated. Vuhere natural ventilation is not sufficient the Ch3.ef of the Fire Deg�zrtment may re�v�.re forced ventilation v�Tith a vent openin� -11- . , - . , . , of at least �0 sc�uar� inches in the tiYc?.1.1 at the flaor l�vel near each open receptacle containing such liGuids, or each heating device from v�hich v�pors may escape, and opposite to any door or other air inlet. Such openings shall be covered with 2x2 mesh No. 16 galvanized Uvire vaeb and shall b� kept clear of a11 obstructions. From each vent opening a flue, of at least 20 s�uare inches area and of non-combustible materials, built into t��e ��all ar floor or securely fastened thereto and sa arranged as not to be subject to mechan�.cal injury, sha1l conduct to � and through a sparkless ex:riaus� fan, to be run continuously, �id whi,ch shall be of svfficient size to change the air in the room com�letely ev�ry five minutes. A�l disch�.r�2 outlets oi vent pipes shall be providect with l�;xl�? mesh or e�vivalent non-corrodi.ble wire screen and shall be so loca�ed that tney j�Ti11 not expose surroundi.ng property and shall be acceptablp to the Chief of the Fire Depart�ent. xn.y other ecuivalent system of vsntilation may be used. whe�? approved by the Chief of tne Fire Depart�nent. SECTIOTv 38. �`here flamr�able li�uids are kspt, useci or handled, dry' s�.nd, ashes� chemical extinguishers or other 2xtinguishing d.eva.css or r��terials shall be provided in such ruQ.ntities and �vitlz such pails, scoops and ot�.er firs appliances as may be dir�cted by the Chief of tne Fire Departmen.t. h reasonable cuantit�y of loose non-cor�bustible absorbents, such as sand or ashes, shall be kept conven�ent for use in case of oi? leakage or ov�rflow. � � SECTION 39. tiVithin the iimi�s given in S�ction 45, ba.rrels and drums containing Class I, TI or ITT lirui�s stored outside any building shall not be piled u�on each other nor stored in a ` �passagevray or beneath any thindovJ and no open lights shall be -1`�- a . . � ' . � ' � . permitted in any such s�orage yard. SECTI0�1 40. Drums or barrels far flamnable iiquids shall nave caps, plugs a�d bungs re�laced imm�diately after package is emptied. SECTION 41. Tn all rooms or parts of buildings V�rhich contain flammable Ii�uids in open containers or in v�hicn. the v�,pors from flammable liGuids are present, or in ti�vhich flam�able l��uids ar� used i.n any manufacturing process, the carrying of m�tches is prohibited, and smoking shall be a misdemeanor. Suit��,ble signs Iettered "Sit�iOKTNG PROHIBZTEll BY CRD��� OF THE ChIEF OF THE FTR� D�P,�R.li��NTi� shall be displayed. SECITOIV 4�. Fla.mmable liG,aids s�zall not be dra��rn nor handled in the presence of open f"lame or iire, l�ut rr�ay be dra��n and h�ndleu ��ahen lighting is by incandescQnt electri.c lamps installed in complia�zcQ �vith. the 1�National Electrical Code. 'i SECTIQ�� 43. No po�table �vheeled tank for the handli.ng of flam�able liGuids inside build�.ngs snall excepd si.xty gallons c�.pacity. T�nks shall be of iron or ste�l, at least 3-1Gtli inch thick� uvith all openings :�.t the to�a �.nd screenecl (prefer�:�ly by 40x40 but not less than 30x30 non-corrodible ��ire raesh or its e�uivalent) . U'Jheels shall be �ubber tirPd and tanks shall be so hung as not to be I.ia.ble to be tipped over in ard�.nary usage. Linuids shall be draifan fron tanks by means of tight fitting pumps. SECTION 44. No flarama.ble licuid shall be nandl��. ar stared ' ne�z� any open flame or fire. i CH�.PT�'I� I I I STOF'�:iGE T.ANKS--CAP.�ICITY, LOChIT01�1 ��.�D RESTI�ICTION. � SEC'1IGi1 45. Excep� as otherv�ise p��mittsa i� this ordinance the s�orage of ilammable 1.icuids shall be outside buildings in ' -13- urader-grovnd tanks or �.bove ground tanks, excegt that the storage in tanks above ground shall not be permitted tvithan the fire lim�.ts of the City of Renton, V�Tashington, as notiv established by ordin�.nce, or �.s the same may hereafter bs established. by ordinance of the City. Or any of the territory v�here above ground tanks are liable in case of breakage or o�rerflow to endanger surrounding property or contents thereof or to flow into water ways �vithin the City �limi�ts of said city, unless said tank is proteeted by embankments or da.kes as provided in Section 53 hereof. � � SECTTQN 46. Tanks bura,ed underground shall have the top of the ta.nk not less than 2 feet belou �he surface of the grovnd, and belog� , I the level of any p3.p�,ng to which the tanks inay be connected, except that� in lieu of the 2-foot cover, t�.nks may be bur3ed under 12 inches of earth and a cover of re�.nforced concrete at least 6 i.nches in thickness which shall extend at least one foot beyond the outline of tarlk in aIl directions; eoncrete cover to be placed on a firm, well tamped earth �oundation. Where necessary to preverxt float�ng, tanks sh.all be securely anchored or v�eighted. I�There a tank cannot be entirely buriea., it sha11 be co�ered over with earth to a depth of at le�.st 2 feet with a slope on all siaes not steeper than 1 1-2 feet Y�ori�ontal to 1 foot vertical. The limit of stor�ge permitted shall depend upon the location ' of �h� tank with respect to the building to be supplied and ad�acent buildings, as fol�o��s: �AXIMUB� C1�PkCITY 0�' T�NKS FOR UN��RGROUND ST4R�!GE LOC�.TTON If top of tank is : Gl�.ssrl, 2, 3. : Cl�.ss 3 above lo�ver �han all floors, basemen�s, :IInder 100 degree : 1�0 degrees F. cellars, or p3.ts of :Fahrenhe3.t flash- : flashpoint. all buiidings. :point, : i , • , • a y � _�a_ a. ��uithin a radius of : : 50 feet. : Un7�imited : Unli�ited b. uuithin a radius of : : 40 feet. � : 5Q,000 Gallons : 500,000 Gallons c. ��ithin aY�rddius of : : 30 feet. : 20,,000 Gallons : 200,000 Gallons d. 4tiithin a radius of : . 25 feet. : 15,000 G�llons : 150,Q00 Gallons e. '�lithin a radius of : . 20 feet. : 5,000 Gallans : 100,000 Gallons • f. ',�Vi thin a radius of : o �� 10 f�et. : l, 500� Gallons a 75,000 Gallons �;_._ ; g. If �lithin 10 ft. � : . of any building, : . ,S'�..�-��7 Gx�i,i��� and the top of tank: • � , �3 �f, __�Cz,� is above the lovJest: o iloar, basement, : . cellar or pit of : . �" the building. : 500 Gallons , 50,Q00 Gallons ', : . h. ,Tank located beneath a building shall be below al1 porti.ons of �I r (\ t:nat buil.ding and is limited in capacity only in respect to other buildings as given above u.ncier �. to g. ' I� tolerance of 10 nercent in capacity shall be a1loj�ed in tanks of 150,000 gallc�ns or less capacity. SECTTON 47. Outside the limits given in Section 45, the capaci'�y of each outside above ground storage tank used, designed or� intended for Class I and II li�uids shall be lir�ited as given in Column A / of Tab12 T. For Class TZT 13cuids having flash poizzt of 150 degrees Fahrenheit or belova, ana a storage aouble th�t given in Column A, Table T, will be permitted; for Class III li.�uids havizzg ilash point above 150 degrees Fahrenheit, a storage �.66 times that given in Column ,�., Table T, will be p�rmitted. Table I. Capacity of Outside Abave Groun� Storage T�.nks for Class I and II li�uids. Column A. I�inimum Distance of Tanks to Capaci.ty of Tank line of �djoining Property Gall.ons v�rhich may be built upon 300 or less. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 feet 500 or less. . . . . . . . . , . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 fQst � . . . -15- 1,000 or less. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . o . . . . . . . . . . . . . . . �0 feet 8,000 or less. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 feet 1`�,000 or less . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 feet 1�,Q00 or less . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 feet 24,000 or Iess . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 feet 30,000 or less . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 feet 48,000 or less . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 feet 7�,000 or less . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 feet 100,000 or less . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .lOC feet 150,000 or less . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150 feet 250,000 or less . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .250 feet 500,000 or less . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .300 feet 1,000,000 or less . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .350 feet Unlimited. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .400 feet For tanks containing Cl�ss 2IT licui�s having flash point above 150 degrees Fahrenheit and of ov�r 400,000 g�l�ons capacity, a minimum distance of 175 feet to adjoining property or nearest building may be permitted, provided that an ap�roved type af extinguishing system is installed for the tank and ca�ering other p�.rts of the yard. For tanks contain�ng Class III li�ui�s having flash point above 150 degrees FahrQnheit and permitted from. 50 feet an� up to 175 f�e� oi building or property lin�, the capacity rnay be incredsed 33 percent if the tank is provided �,�ith an approved �xtinguisl�ing s�-stem. The minimum ciistances bet�leen �.bove ground stora.ge tanks shall be in acco�dance �T�ith the follo���ing table: Table 2. A�inimun Distances B�t�veen Above Ground Stora�e Tanks. (Applies to all classes of �iicuid) Capacity af Tank. (or of the larger of the tti�ro tanks bett�een ���hich distancp is to be measUred) 300 ar less . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . : . . 3 feet 500 or less. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 feet 1,000 or less. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 feet 8,000 or Iess. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 feet 12,000 or less. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 feet 18,000 or less. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 feet - 24,040 or less. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 feet . 30,000 or less. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 feet 48,000 or less. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 feet 75,000 or less. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 feet I 100,000 or less. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 feet 150,000 or less �istance ecudl to the diameter .(or 2Q0,000 or less the greater horizontal dimensian if 50Q,000 or less the �ank is r�ot cylindrical) of the 1,000,000 or less tank, or of the larger of the two _ 2,500,000 or less tanks betr�een ti�hich dist�.nc� is to � � -- be measured. -15- . : � , . �. For tanks containing Class III Iicui�.s having flash point above � 1�0 degree,s Fahrenheit and af over 400,000 ga3lons cap�city, a minimum distance of 175 feet to adjoi.ning property or nearest building may � be permitted, pravided that an approved type of extinguishing system is installed for the ta.nk and covering other parts ol the y�rd. For tanks containing Class TIT lic�uic�s hdving flash point above 150 degrees t�ahrenizeit and permitted from 50 feet and up to 17� feet of building or property line, the capac3.ty may be increased 33 percent if the tank is proviaen with an approve� extinguishing systea. i , The minimum distances betvi�een abave ground storage tanks shall _,�• ' be in aecoz�dance � zth the following table: �abla 2. �Niinimum flista.nce Betc�reen l�bove uround Storage Tanks. (Applies to alI classes of licuid) Capacity of Tank. (or of the larger of the two tanks 1ylinimum Distance of Tanks to betvJeen v��hich dist�.nce is to be lin� of ad�oining Property - measured) v�rhich may be build Upon 3Q0or less. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 feet 500 or less. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 feet 1,000 or less. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . �0 feet 8,000 or less. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 feet 12,000 or less. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 fPet 18,000 or less. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 f�et ., 24,000 0� less. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 feet 30,000 or less. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 feet 48,000 or less. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 feet 75,000 or less. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 feet 1G0,000 or less. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 feet 150,000 or less. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .�.,�,,��. . 154 feet 250,000 or 1Qss. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ::`. . . . . . . . 250 feet 500,OQ0 or less. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .�._�. : .,. . :�: . : 300 feet 1,000,000 or less. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 350 feet Unlimited. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ._..._• a�. 400 feet - �_�n;��.. K.,�:� SECTII�N 48. Each above ground tank, inside or{you�tsiu.e buildings, - .....��>>� over 1,000 gallons in capacity, shall have all manlioZ�s, „hand 'nol.es, vent openings and other �xpen:ing �rhich may permit tYie escape of flammable vapor-, provi.ded v�ith a non-corrodible v��ire scrQen (preferably 40x40 mesn but not less than 30�30 mesh or its ecuivalent,) so attached as to com�letely cover the open�.n� and be prot�cted aga.inst clogging. A safety valve sh�.11 be provide�., or manhole covers sha.11 be kept closed by v�eight only, and not firmly attachect. The scr�er�s -1'7- t on openings inay be mac�e r�movable, but shall be kept normally iirmly attached. SE�TTON 49. pbove grounci tanks for Class I and TI li�uias shall have paintPd conspicuously upon their sides in lett�rs at 1ea.st 2 inches high, �he ��ording, t1FI,.��I�n�i13LE--K��P FTRE h6'r'i�Y. T� ' SECTIQN 50. Tanks shall be constructed of galvanized steel, of open hearth steel or of htrought iron af a thickness not less than that specified in Tables 2 and 3. For li�uids heavier than 35 degrees Baurne, tanks �riay be constructed of concret��ccordance with the Regulations i of th� National Fire Protection Association. Tab1.e 3. Und�rground Storage Tanks: �iinimum tihickness of mai,erial. -�r- C�.pacity Gauge ']�iin. Thickness af Iv2a.terial , o Gallons (U. S. Standard) Lbs. �er Sc . Ft. v��'" � �, � � ,.� 1 to. . . . . . . . . . . 285 16• 2. 50 ��•��' �86 to. . . . . . . . . 560 14 3.125 �;" �. � 561 to. . . . . . . .1100 12� 4.375 '�h,�' 1101 to. . . . . . .4000 7 7. 50. ` , 4QG1 to. . . . . .12000 �4 inch 10.00 12001 to. . . . .20000 5-16 inch 12. 50 20001 to. . . . .30000 �-8 i.nch 15.00 For tanks oi 11Q0 gallons and r�o�e a tolerance of 10 percPnt in capacity shall be allowed. Tanks of open he�.rth steel or wrought iron thinner than No. 7 gauge shall be galvanized. For Class IIT liGuids, if �,deGuate intern�.l br�.c�ng is �Srovicted, tanks from 1�,001 to 30,000 gallons capacity may be built of steel , plate 1-4 inch thick. AlI joints of tanks shall be riveted and caulked, brazed, ���elded, , or madA ti�ht by some ecually satisf�ctor� process. Tanks shall be tight and sufficiently strong, to bear v,�ithout i.njury the most severe strains to �nThich t�ey may be subject�d in use. Shells of tanks snall , be properly reinforced vJhere connect�ons are made, and all connections ` ' ��de through the top of the tank above the licuid levPl. -18- Taizks for systems Under press,are shall be designed ior foui tim�s � � - - • - tne maximum ��orking pressure, anc� test�d to tcvice tne m�?ximum v�orking pressure. All iron or steel snall be thoroughly coated on ou�tside arrith tar, asphal�um or other sui�able rust-resisting mat�rial. Udhere soil contains carrosive substances, such speczal protection sha11 be proviaed as m�,y be re�uired by th� Chief of the Fire �ep�.rtment. Vi�ith the appraval of th� Chiel of the Fire Department, t�.nks of copper or oth;:r suitable m�,terial may be usPd if after the necessary t�andling i.ncident to i.nstallation they are ecuivalent in strength, rigidity, dura.bility and tightness to the steel or iron t�nks described above. � SECTION 51. T��nks {including tops) shall be construc��d throughout of open hEarth si,eel or of v�rought iron of � thickness in aceordance ��:ith the folloj�ing reGuirements. No open ta.nk shall be used. For licuids o� 35 aegrees Bau.me or heavier, tanks may be construct�d of concrete in accordance �rith the Regulations of the National Fire P�otection Association. (a) Horizontal or Vertical Tanks not Over 1,10� Gallons Capacity. Capacity (Gallons� �in. Thickr_ess oi �lia+erial 1 to 60 "' 18 Gauge li. S. Std. 61 ta 350 16 Gauge U . S. Std. 351 to 560 14 Gauge L'. S. Std. 561 to 1I.�0 12 Ga.uge U. S. Std. (b) iiorizontal Tanks Over 1,100 Ga.11ons t;apacity. Tanks of this class shall be of sucri materia.l and so censtructed I as . to haee a factor of safety of a.t least 2. 5 �+:�ith hydrostat�c head ' figurec� vlith yvater. Tre �inimum th�ckness of srell or he�.d shall be 3-16 in. (No. 7 g«uge, U.S. Stand��.rd.) ' _ -- �i -19- The thickn�ss of shell plates shall be in accordance �rith the follov�ring formula: t e�uals: P x r x F T x E ��lhere, t--thickness of plate in inches. P--v��erkin� pressura �n pounds per scuare inch. r--r�zaius of shell (inside) in i,nches. F--factor of safety (taken as 2.5) T--tensile stren�th of pla�te in p�unds per sGuare inch. E--efficiency oi lon�itudinal riveted joints. (c) Vertical Tanks Over 1,100 Gallons Capacity. I Tdnks oi this class shall be of stzch m�teri�,.l �.nd so constructed as to have a f�ctor of szfety of at least 2. 5. The r�inimum thick.ness of shell or bottom shall be 3-16 in. ThQ mininu.m thickness of roof shall be I-8 in. I Thc thickness of plates shall be in accordance with the foliov+�ing formula: t equals 2.604 x H x D x F y S T x E Where, t--thickness of plate in inches. H--height of tank in feet �.bave th� botta�i of the ring under car_- sid era.tion. D--diameter of tank in feet. F--factor of safety (taken as �. 5) S--specific gravity of li�uid stared (t=rater ecuals l.) T--tensile strength of plate in pound.s per s�uare inch. E--effieiency of vertical joint in ri.ng under consideration. The tensile strength of the steel shall be t�_ken as 55,000 pounds per scuare inch, and the shearing strength af r:ivets s1�all be i;�.ken as 40,000 pounds per scuare irlch. T�.nks shall be i�ivetea, welded or brazed ana. shall be c�.ulked or otherv�ise r.laae ti�ht i.n a �varli�anlike ma.nner. The top of' the t�.nk shall be securely fastened to top ring w�.th �eints having the same ' tightness as the joints beti,feen �he rings. 1-�lI iron or stsel tanks sh�.11 be thorou�hly coate�. on the outside with tar, asphaltum or other suitable rust-resisting r�aterials. -20- P�oofs or tops of tanks sn:�Il h��ve no unNrotected openin�s. P�oofs or tops shall be firmly and perman�ntly jcir_e�. to the tank and all joints shall be riveted and caulked, br�zed, v�eld.ed, or m�.de tight by oth�r process satisfactory to the Chief of' �th� Fire Dep�rtMent. Exce�t in oi1, reiineries er l�rge i�dater t;rr�inals, tanks containing flam�able licuicls h�,vin� f'l�.sh point beloVa 70' degrees F. (closeu up tester) shali have paintect conspicvously upon th� side the rvording nFLA1J1����BLE--Ki:EP FIR�� !-�t'�j�Y. ft ti'lith the approv�l of thp Chi.Ef of the �'ire Dep3rtment, tanks cf copper or other suitable material' may be used if after the necpssary han�ling incident to install�,tion, triey are eczivG.lent in strength, ri�iaity, durability and tigh�ness tc the ste�l or iron tanks described �.bove. For liruids af 35 degrees Baume or heavier, tanks m�.y be con- structed of concrete in accordance ti�itr the Regulations of the i�ational Fire Protection Associati.on. SECTI01�1 52. Tanks shall be ri.vetea, titiTelded or brazed, �.nd shall be soldered, caulked or ethervrise made ti�ht in a mechanicol and v�.ork- manlike mann�r•, and i.f to be L�sed ti�vith a pressure disch�..rge system shal� safely su�t��in a hydrost�tic test at least dauble the pressure to vinich tank m�.y be subjected. Top of tan'� shall be securely fast�n�d to top ring, v�ith joints of ecual tightness to those bettiF�Teen rings. Tanks shall be cover�d v�_;.th �.sphaltun or other non-rusting paint or coatin�. xll pipe connections shall be maae thr�t�gh flanges or meta.l reinforcements secvrely riveted, welded or bolte� to the tank and sha.11 be made tharovghly tight. Tanks shall be constructecl entirely of inet�.l, inclucting top, sides and bottom; all cpeni.ngs, shall be gas tight, except bre�.ther vent, v�hieh shall be screened as provided in Section 48. SECTT�N 53. kll tanks shall be �lectr:ically �rounded by resting directly on moist eartn or otherv�rise electrically groUndea to per�anent -21- �oisture to the s�tisfaction of the Chief of the r�re De�art�ent. No insula.ted connections sha11 be permitte�. Telephone poles or other projections Iiable to act as lightning disch�rge points sh�ll be kept as far as practicable from tanks. � �11 steel �rork af r�inforced con- crete tanks shall be interconnected and grounded by an a.pprove� method. Tanks more than one foot above the ground shall have foundation and sup�orts of non-ca�bustible materi�ls except th�t 4vooden cushions may be permitted; no combustible m�teria.l shall be permittea under or ��sTithin ten feet af any above grovnd outside storage t�.n.k. Tn locations v~rhere Cbove ground tdnks are liable in case of breakage or overflov� to endanger surrounding pro�erty, each tank shall be protected by an erribankment or dik�e. E�ibankments or dikes sh�.11 be constructed of e�rthvTork, clay core v�rith cinder-fill, mason-ry, or concrete, approved by the cY�ief' of the Fire Departruent. Such dikes, vThen constrvcted oi earth�vorY or el�.y core cinderfill, sh�.11 have a capacit� at least one and one-half times tY�iat af the tanks. V1hen constructed of masonry or cancrete dikes sholl have a. capacity at least ecuivalent to th�.t of the tank. Earth�,tork emba,nkm�nts shall be firmly and corip�.ctly built of good earth iror� vrhich stanes and veget�.ble matter have been removed. Earthwork embankments sha.11 have a fla.t section at the top of not less than three feet and sh�.11 liave a slape not steeper than 1 1-2 feet horizontal to �_ foot vertical on both siaes. I Small t�.r.ks ti��ith capacities of not over 25,008 gallons each may be grouped �.nd a, di.kE built around the group of �anks. S�CTION 54. Tanks in buil.dings shall be constructe�. �.nd installed a.s follows: (a) Tanks ior Cl�,ss II ar�d III licuids of 120 gallons or less � capacity, sh�.11 be of galvanized. steel or ti.n plate, suit��ble for the 6 purpose, v�ith all joints locked, dauble seamed or riveted, and �.lso -`?2- , . , , , , . , � . I' soldered or mad.e t1 gnt by some e�val.iy s�ti sfactary nethod, material I shall be of not less than No. 2G gauge U. S. Sta.ndard, eyce.�t that �rThere �� used in connection �r�ith ard in the same roam v��ith ail �urning ecuipmen� No. 16 g�,uge m�ts.l shall be used. Original barrels, or �r•ums may be used uritil ccnter.ts �,re draw,n, if substdritially plz.ced to prevent tip�ing or rolling, v�ith pump inse�rted tn.r�ugh a close fitting connection in side or hEad. (b) Ta:nks for Class TI and ISI Ii�uias of greater than 120 � gallons cap�.city, shall be of thickness spvcified in Table 2, Sect�.on , 50, ar of conerete, and shall be venteci as speci�'ied in Section 56. ' (c) Tanks snall be locatea below the 1eve1 of a.ny piping to U,hich I they may be conrecteca., or if this is i�.,oracti.cable, arrangements ' sat�sfactory to the Chief of the Fire Depa.rtment shall be in�.de to prevent siphoning or gravity flovJ in case of a.eciden.t to the ecuipment � or piping. (d) Tanks shall be set on a fir� foundation and those exceeding 2500 g�.11ons capacity sh�ll be supparted independ.erltly of the floor construction. (e) Steel tanks exceeaing 250 g�.11ons capacity �nd inst�lled in connection v��ith oil burnin.g ecUi�r�ent shal 1 be completely enclosed tia7ith a heat insulation ecuivalent to reinforced concrete not less tha.n 12 i.nches in thiekness, v�ith at least a 6 inch space an sides betv:een tank and concrete insula.tian filled �ith sand or vrell tamped earth, and vaith l� incries of sand on tap af tank_, either betti°;een ta.nk a.nd cor.crete sla.b ar a.bove concrete slab. (f) Concrete tanks shall be completely enc�osed s��ith a heat insulation of reinforced cor�erete not less than 8 inches in thickne�s, ;��ith at least a 6 inch space on sides bet�reen ta.nk and concret� insula- tion fill�d vaith sand or v��ell tamped earth, except that for top of tank an insul�.tion of 12 inches of sand witrout concrete covering shall be deemed sufficient. -23- (�) �'�lls of conereLe tanks shall be constructed inae�endently of an not in contact v�ith the building ��alls. (h) In ordinary builciings the �ross capacity of t�.nks shall not exce�d 5,000 gallons. (i) 2n fire-rEsistive buildings the gross capacity of tanKs shall ' not exceed l0,OG0 gallons. (j} In any building, if in a fire-resistive or detached room cut off vertically and horizontally in an approved mc,.nner from oth�r floors ,I of the n�ain buildin�, the gross capacity of tanks rriay be not exceeding 50,000 g�.11ons, ���7ith an indivicival tank capacity not exceeding 25,000 gallons, provided tYie insulati,ng sand specified under paragraphs (a) , (e) and (f) shall be increased to l� incres on sides and 18 inches on top. CHI3PTER VI PIP�.NG xI�D OTh�;R tiPPL1RT�INC�S. SECTTON 55. All connections from tank to any house or subsurface dr��.nage system shall be so arranged as to pr�vent the flov�r of flammable licuid to any such system or th� leakage of any flammable gases from such li�uid, or approved flammabl� li�uid collectors sha.11 be providecl in sucll connection. SECTIQN 56. An open or aU.tomatic�.11y operated galvanized iron vent pipE v�ithout trap, araining to the tank, sha11 be proviclea for every tank v�Thich may contain flammable vapor. The lower end of the vent pipe shall not extend through the top into tYie tank far a c�is tance of rnore than one inch. Vent openings shall be screened (pref�rably by 40x40 but not less than 30x30 non-corrodible v�ire mesh or its ecuivalent) a.nd shall be of �ufficient area to per�it escape of air ar vapor during tne filling �� operation. Vent openings, except those automa.tically operated, shall in no case be less than on� inch in ciiameter. Screens sh�.11 be accessib�e for examination, and removal. Vent pipes ahall be provided vaith -24- weatherproof noods and termin�te autside of building 12 feet above top of fill pipe, or, if tight conn�ction is made in filling line, to a point one foot a.bove the level of the top oi the highest reser- voir from which the tanks may be filled, and preferably not less than th�ee iee�t measured horizon�ally and vertically, from any ti5�indov� or other bui�.ding open�.ng. Individual vent pipes shall be provi.ded for each tank, except �hat ��here a battery of �anks designed to hold the same class of liGuids is i,nst�.11ed, the ver�t pipes ma.y be run into a main header. In such case individual vent pipes shall be provi.ded 1°,�ith screens betyreen tank and header and the connection to the header shall not be less than one foot above thE level of the top of the highest reservoir fro� v��hich the tanks may be filled. I SECTION 57. kll draiv�ng-off pipes terminating inside of any I builaing shall h�.ve valves at the discharge end; when delivery is by I gravity, pipe sha11 have a shut-off valve (vvhich shall preferably be I� of the automatically cZosing type) and in adciition shall have an �! emergency valve. I SECTIOI�i 58. tiVhere tanks are �bove groun� there shall be a val.ve located near the tank in each pipe. Tn cdse tv.To or mo�e tanks are cross-cannected there shall be a valve near each t�nk in each cross cannection. SECTION 59. Pumps delivering to or taking supply from above ground storage tanks sha11 be provi.aed v�ith valves on both suction and discha.rge of pump, and in delivering to tanks a check valve to prevent flot� of licuid from tank to pump. Electric motors or internal combustion engines shall not be pl�.ced ben�ath ta.nks or els�ti�here Vrithin the line of vapor travel. SECTION 60. Ifdhere underground tanks �.re used, all pipes carrying flammable licL?itis, exce�t in dry-cle2�ning establisrments, sha11 pitch -25- towa.rd t�nks without any traps or pockets, and shall enter tznks at the top. SECTIa� 61. �11 piges used in systems for flammable Ii�uids shall be of standard full weight brass, galvanized iron or steel, with suit�ble brass or galvdnized �alleable iron or steel fittings. Tdo rubb�r nor oth�r packings, and no flanges, shall be used. 2f unions are used, at least ane face shall be of brass, with close fitting conical �oints. Litharge and glycerin, shellac or other suitable , material shall be used on pipe joints. Outside piping shall be pro- tected �.gainst any mechG.nic�.l injury vvhen vvi,thin 5 feet of ground' level. Inside piping sha.11 be rigidly su.p�oorted. SECTTON 62. Defective and leaking pipes shall be m�.d.e tight imrnediately or replaced. SECTION 6�. Piping carrying Cla.ss T and IZ J_ic�uids, un.less vritnout joint or connections, shall not extend through any room v�hich contuins any open light or fire. SECTTON 64. The end. of the filling pipe for under�round storage t�.nks for Class I and TT licuids shall be carried to a.n approv�d loca- tion outside of any building, but not within 5 feet of any entrance door, or cellar opening, and shall be set in an approv�d metal box v�ith cover which shall be kept locked except durin� fillin� operations; this filling pipe shal.l be closed by a scretiv cap. A non-cerrodible screen strainer (preferably 40x40 mesh but not l�ss than 30x30 �esh or ecuivalent) shall be placed in the sLpply enct of filling pipe. SECTION 65. Deliveries of flamm�.ble li�uids of Class I ana II, , v�here p�actical, sha11 be m�.de directly ta the stora.ge tank through the filZa.ng pipe by r�eans of a hose or pipe betv�een the filling pipe and barrel, tank v�agon or tank car from u�rhich such Ziquid is being dr av��n. S�CITON 66. Except as permitted in Section 68, f1am�.able li�uids ' -26- . .. , . , , � . shall be dravy�n fram tanks by pumps so constructed as to prevent leaking or splashing, or by some other system ��praved by the Cr,ief of �he Fire Department, �ith cflntrolling 2ppar�:tus and piping sc arr�nged as to all.o�r control of tre amoUnt of discharge a.nd prevent �.eakage or discharge inside the building or any derangement of the system. When inside a building, the pump or other dr�.rbing-off device shall be located on or abave the grade floor, preferably ne�3.r �.n entrance or other vaell ventilated place. S�CTIUN 67. Except as permitted in Sect�?on 68, no tanks, drums nor other cantainers inside a building, or dischG.rg�.ng insade a building, shall be provi�ed +rrith �. fauce� or other botton-drativing czevice �:hich v1i11 �ermit the gravity flo�Ar of licuids inside the bvilding. Pi�es ��a�l not termi.nate at any point lower than the Ievel of saurce sup�Zy. SECTION 68. The Chief af the Fire Department may permit the storage and gravity floU� of il�.mmable licuid in connection vvith �.omestic oil burning eGuipments, in refineri.es, anct in manufacturing and jobbing plants where the nature of the manufacturing process reGu�.res such stoz°a�;e and flaw, and also the storage and gravity flow of commodities oi Classes Tl and TTI in stores, plants and establishments, �vhere the na.ture of the li�uid i�vill not permit pu�nping; provid.ed that the contents of tanks holding Class I lic�aid shall be sufficien.t only for one d�.yt s operation and such stor�ge shall be in a room in accordance vyith Section 29. SECTION 69. Supply to stationary internal-canibustion engines using fla.mma.ble liGuids shall be by pumpir.g from tan�s located as given in Section 46, and 47. ., . SECTION 70. Tn ecuipments for the use of flammable li�uids as a fuel u:nder boilers, furnaces, kilns, ovens, etc. , stora.ge tanks shall be loc��ted as given in Sectian 46, 47 or 54. -2'7- . , . . . , , � , SECTICIN 71. Pumps used. supplying internal co�bustion engines and fuel oiI burners �hall be ec�uipped vvith � pressure gauge for oil and the sys��m shall be so a.rranged that the oil pressure cannot at any time exceed a safe �n�orking pressure, a relief valve to be provided to return surplus oil. to the sup�ly tank. CH��_PT ER V � I'� SECTION 7�. No permit shall be grwnted for the establ�ishment of �' a nev�� pla.nt or an addition to a pla.nt for disti.�ling or condensing � w�thin the linits of the city until af ter a survey has been made by the Chisf of the Fire Department and an investigation n�ade of all hazardous conditions connected thereti��ith. 1.f there are no schools, churches, hospitals or public halls w�.thin 300 feet, and na other � buildings than those of the plant v�Ti.thin 150 feet of the propased �_ _ distilling or condensing pl�t, and (or) other conditions are consistent with the spirit and intent of this crdinance, the Chief of the Fire i�epart�nent shall grant a permit for the location desirect; provide�., also, tYa.at a �uarantee to mainta.in an open space I50 feet ti�i�.e on � all sictes shall be give��tre applicant. SECTION 73. Stora.ge and piping dt such plaxits shall be as in Chapters TIS and IV of this ordinance. S�CTION 74. NevJ and existing jobbing plants, storehouses, and distributing stations, shall be constructeci as provided in and confor� to Section �4, ti5, �?6, �7, 28, 29, 30, 31, 32, 37, 38, 39, a-0, 41, 4� and 44. SECTTON 75. In new and existing plants, rooms in v�Thich Class T, II ana TI:T licuids are stored or na,ndled in other than original cont�.iners, sha.11 be heated by steam or hot uTat�r. Unpierced fire v��alls shall 'I isolate fro� such rooms all steam boilers, furnaces or fires, ar any �- electric dynamos or �otors, or other spark e�itting devices, provided, -28- . . , . , , � . �" I ho��ever, the explosian proof moto�s may be used in such rooms. SECTION '76. Storage and pipin� at such pl�.nts shall be as provided in Cna�ters I7:I and IV of this oi�dinance. SECTTQN 77. All t�.nk v��i.gons, and wwgons containing tank v�i th faucets, v�hen used ior distrZbution of flummable licuids, shall be of siabst�.ntial and �;orkmanlike construction, anci shall be subj ect to the approv�.l of � the Chief of �the Fire Department, tivho shall inspect and keep a record of such wagons or vehicles, which shall be plainly marked v�ith tneir record number. All faucets cannected to such tank v��gons sha11 be kept locked or have hanale rQmoved �Jhen not in actual u�se, such handle to be so constructed that it may not be r�moved except vihen the faucet is tightl.y closed, and all measures a.nd faucets shall be covered or ather�ise protected. , S�CTIGiV 78. Containers of Class T and ZT li�ui�.s shall be painted �, red and be conspicuously lettered in black ��Dangerous--Y�ep Lights and Fires Awa.y and Store outsicie Builaing. yr Cont�.in�rs of Class IIl li�uids shall be painted green and have conspicuously m�rked in v�hite Ietters, fTF1�.mmable Li�u�.d--Keep Fire k��ray and Store Outside Building. �i Tt �hall be unl�.v��ful �o keep or place the above mentioned Z1GL11C7.S in containers otn.er than tYiase marked �.s design�ted, or to use the conLainers, for any other licvids ar substances than those specified, or fdil to keep their exterior clean so thut coloring and lettering are easily d.istinguishable. SECTION 79. The recuirer�ents and restr-ictions given in Section 23, 24, 2�, 26, �7, 28� �9, 30, 31, 32, 37, 38, 39, 40, 41, 4`�, 44 and in Ch:�pters T_II �.nd IV, must be complied with. ',I CFi.(iPTER VI SECTIOTI 80. In netiv �.nd existing plants, roor�s in vtihich Class I, -` I � IT a�d TTI licuids are store�. or handled i,n oth�r than original containers, shall be hsated by steam or hot y�ratPr. Unpierced iire ' _�g_ . . , . , . , , � . walls shall isolate from sueY� rooms all steam boilers, furnaces or fires or any electric dynamos or motors or other sp�.rk emitting d�v�ces, provided, however, thut explosion proof mators may in such rooms be used. SECTION 81. �Ianufacturing plants herea.fter established or erected shall be as speeif3.ed in and shal� conform with the re�uire- . ments and restrictions of Sections 26, 27, 29, 30, 32, 33, 35, 36, 37, 38, 39, 40, 41, 42, 44 and the storage of �.n.d pip�ng used in the hand3ing of' ra�.• stocks of flGmmable liGuids shall be as in ' Chapters TTI and I�. �EGTION 82. �anufacturing pla�ts existing on th� d�.te this ordinance becomes effective shall be as specified in and shall eonform with the orciinance recvirements and restrictions of Sections 26, 27, 29, 30, 3�, 33, 35, 36� �7, 38, 39, 40, 41, 42, 44. Taiaks exi.stir�g inside build�ngs on date vf enactment of ordinance and of la.rger cap�.city than pErmitted in Sect�,on 28 may be used for Classes ' II and ITI 13quids, provided th�.t reasonable safeguards are provided � against in�ury to occupants of the building and to ad�oining � property. S�CTION 83. Jobbing plants, storehouses� retail stor�s and paint and o3.1 stores shall comply with Sections 24, 25, 26, 27, 28, 29, 30, 31� 32, 37� 38� 39, 40, 41, 4�, and 44 and storuge and piping except in ori�inal containers provided in Chapters IIx and IV. SECTION 84, kny person who shall violate any section or any provis3.on or re�uirement of this ordinance shall be guilty of a mi�d���eanor and upon canviction thereof shall be #'ined in any sum not exceeding �100.00 or imprisonment in the city �ail for not exceeding 30 days or by both such fine �.nd imprisonment. I SECTIQN 85. That Ord�.nance No. 414, passed and approved I1o�rember 2�, 1915, shall be and the same is her.eby expressly repealed. � � -�0- � i . f i. �'� ' • , • • , , , � • , , • � . � � SECTTG�I 86. This Ordinance snall be in full force and Offect five (5) days from and aft�r its passage, approva.l and legal publica- tion. - Approved this 19th day of September, 1939. ���� I�,,�.YOR Passed b� the C3ty Council of the City of Renton, V`un. , this 19th day of Septe�nber, 1939. r CITY `L�.K s 1�PPPtiOV� ' ` FOR��.: � CITY ATlORTd � � Date of Publication: C���' � � � �- � � , -31-