HomeMy WebLinkAboutR-389414DETENTION VAULT SECTIONS
6
Y Z
RECORD DRA WING
8
w 3
a o rn
Q
Z
W
>
O
0 �
o
U
Q
�— Lo
m0-
F-
� F_
�
Z
Z C
to
o
m
o
W
`
(,)
J
}
^ Q
W
C'7
T-
0
a
fn
Of
L
r �
F1
0
U)
a_
a
O
L
(J)
w
c
v
a
U
C
I
�A�
73
m
rn
o
a
0
a_
m
m
M
C
p� L
0 z0
H
J z
a �J Q
Ur Q
LZ
0
>Fx
0
J
J U U
U
Z Z
S - O
Z J Z 0
0 U
Z D�<
0 1 Z J
Q U
0
o s o
z 3 cYi
Q
N
Q
d
Q
0)
00
\
\
W
w
��
o
X
o
0
lia •■
N Q
Q
CALL BEFORE YOU DIG:
w Lo -.0-Z 1-800-424-5555
U-
NEW 8" PVC ROOF
DRAIN DOWNSPOUT
COLLECTION PIPE (TYP.)
NEW CB 3 TY E1-
W/STANDARD T P
(PER DETAIL ON S EET C10)
RIM=41.19-4 f.02
IE= n "
36.87 (1 E) + '
37.07(8n
rn
Ir
I DI •.
I D
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
SAO��E W A Sy1
24661
/ S T
AL ECG
07/26/2
n
NEW 68'x2O' DETENTION VAULT
(SEE DETAIL SHEET C11 FOR SECTION
MAX W.S. EL.=38.00
STAIC W.S. EL.=32.00
BOTTOM EL.=31.50
pl V LT 4.76
GLT C v .
®. LT
— —il -- —� ---- p — -- D—°$--o—S£IF72 �CF
�--- LF 1271
CPS v..v
S� 0.509� D
t>
I I.
a t NEW 8' INC ROOF a
a I DRAIN DOWNSPOUT
COLLECTION PIPE (TYP.) I a
a
EX. 1 IDE
d I. — — — — — — — — — — —
° UTILITY EASEMENT MARRIOTT
RESIDENCE INN
--------- FF = 42.00
I � I
I
I
1
VAULT ACCESS
LID
PAVED
SURFACE
rAl
FIELD VERIFY LOCATION
FOR ATTACHMENT OF SHEAR
GATE HANDLE TO WALL
OF VAULT
BOTTOM OF LID
ELEVATION=38.50
NOTCH WIER
EL=37.50, WIDTH=1 1/4"
MAX WS EL=38.00 CLEANOUT SHEARGATE
HANDLE TO BE HUNG
L147- FROM LADDER FOR
EASIER ACCESS
4" ELBOW AND EL=36.00
RESTRICTOR PLATE
W/ORIFICE DIA=1 1/4"
�_�_12" MIN.
PIPE SUPPORTS:
3" x0.090 GAGE 12" CMP
BOLTED OR IMBEDDED 1;:::
2" IN WALL @ LAR
MAX. 3'-0" SPACING W
(MIN. ONE SUPPORT)
.00CLEANOUT GATE:z 12" C
8" DIA. SHEAR GATE STANDPIPE
(DETAIL ON SHEET Cl 1) N ;
IE=32.00
VAULT BOTTOM
0.5' DEAD STORAGE EL=31.50
Z_
N
RESTRICTOR PLATE
WITH ORIFICE
DIA.=1 7/16"
FLOW RESTRICTOR RISER IN VAULT
NOT TO SCALE NOTE:
SEE STANDARD PLAN 237.30 ON
SHEET C11 FOR MORE INFORMATION
AS -BUILT
RENTON HOTEL PERMIT #U15008433
ENGINEER:
BARGHAUSEN CONSULTING ENGINEERS
18215 72ND AVENUE SOUTH
KENT, WA 98032
(425)251-6222
(425)251-8782 FAX
CONTACT: DAN BALMELLI
"CERTIFY THAT THE INFORMATION SHOWN HEREON WHICH WAS
AS —BUILT BY BARGHAUSEN CONSULTING ENGINEERS, AND MAY
INCLUDE LOCATIONS, ELEVATIONS, DEPTHS, PIPE SIZES, AND
AS —BUILT COMMENTS, ACCURATELY REFLECTS EXISTING FIELD
CONDITIONS AS DETERMINED BY ME (ALI SADR) OR UNDER MY
DIRECT SUPERVISION ON THIS DATE: 07-26-2019."
SIGNATURE: U G�
CITY OF RENTON
COMMUNITY AND ECONOMIC DEVELOPMENT
DETENTION VAULT SECTIONS
MARRIOTT RESIDENCE INN
O / = DESIGNED AS
2 �r i DATE 09/14/2015 FILE NO.
S �� �co DRAWN M B
G`T/NG ENG�CHECKED AS SCALE 1 "=30' FIELD BOOK PAGE_
APPROVED SHEET C15 OF 20
DIRECTOR OF PUBLIC WORKS
I
I
I
I
a
x
J
a
Y
O
m
II
a�
U
N
fb
n
00
rn
0
N
ai
a�
0
0
0
I
Ln
Ln
i
LI
O
_J
V)
0
N
1
r7
z
O
F-
0
i
0
i
In
0
0
0
Lo
i
ai
"It
to
Lo
r
O
z
m
O
7
W
U
m