Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
MFP19004101.pdf
DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Major Franchise Permit: MFP19004101 IVR Number: 19004101 Permit Informaon Permit Name:Verizon - MCI Address/Locaon :07/18/2019Application Date:2423049008Parcel Number:601 MONSTER RD SW Permit Type:08/20/2019Issue Date:Franchise Permit Work Class:08/19/2020Expiration Date:Major Utility Job Number:601 Monster RdFranchise Type:Telephone Description:Bore two 4" conduits approx. 770 LF and pull new fiber. Install one new HH. Install approx. 781 LF of new fiber in existing conduit. Demo 5 utility poles and approx. 726 LF of ariel fiber. Pothole all existing utilities. Restoration per City of Renton standards. APPROVED WITH COMMENTS OR REDLINES Contacts Name Address PhoneTypeBilling HOLLY NORTH MGC TECHNICAL CONSTULTING, INC 8521 154th Ave NE REDMOND, WA 98052 B: (206) 618-0651Applicant Matthew Sapp Verizon - MCI Contact Heather Binkly Dycom Industries dba North Sky 11770 Us Hwy 1, SUITE 101 Palm Beach Gardens, FL 33408 B: (360) 254-6920 O: (360) 450-3287 Contractor Business License Number: 36846Construction Contractor: NORTHSC857Q4 Louise Popelka Verizon MCI Buisness - Billing 3245 158th Ave SE Bellevue, WA 98008 B: (425) 240-0238Specialized Billing X General Condions & Signature Permission is hereby given for the work described on this permit according to the conditions hereon and according to the approved plans and specifications pertaining thereto, subject to compliance with the Ordinance of the City of Renton. This permit and plans must be posted at the job site at all times. I hereby certify that no work is to be done except as described above and in approved plans, and that work is to conform to Renton Trench Restoration and Street Overlay Requirements. Call 425.430.7203 or go to: www.MyBuildingPermit.com one working day in advance to schedule an inspections and for ANY work in the Right of Way. Call 8 1 1 to locate underground utilities at least two full business days prior to any excavation. In accordance with RCW 19.122.033(4) the permit holder is required to contact (Williams Northwest Pipeline at 425.868.1010) (Olympic Pipeline at 206.510.0575) (Puget Sound Energy at 425.375.3397) to request a consultation with the transmission pipeline company prior to performing any construction or excavation activities. This requirement to consult with the transmission pipeline company is in addition to the requirement to Call before You Dig as required in RCW 19.122. (Date)(Signature) Page 1 of 1THIS PERMIT AND PLANS MUST BE POSTED AT THE JOB SITE AT ALL TIMES DEPARTMENT OF COMMUNITY AND ECONOMIC DEVELOPMENT Page 1 | Published: 3/30/2017 Planning Division | 1055 South Grady Way, 6th Floor | Renton, WA 98057 | 425-430-7200 Email: franchisepermits@rentonwa.gov Website: rentonwa.gov FRANCHISE PERMIT APPLICATION Published: 3/30/2017 TO THE APPLICANT: Submit an electronic copy of the plans with the Franchise Permit Application and the Traffic Control Application to franchisepermits@rentonwa.gov. Permit cost is $360.50. Inspection fee for trenching more than 60 lineal feet or installation of 6 or more poles will be billed at $60.00 per hour. Franchise Agency: Franchise Job Number: Phone: Contact Name: Email: Job Site Address: Project Name: Description of Work: Please check all that apply: ☐New Construction ☐Repair/Relocate ☐ Underground ☐Overhead ☐Sidewalk ☐Street ☐Open Trench ☐ Bore # of feet: Contractor Name: Phone: State Contractors License #: City of Renton Business License #: “I certify that I am the owner or applicant’s authorized agent and do hereby agree to abide to the terms and conditions set forth under this permit and shall comply with the City of Renton’s Trench Restoration and Street Overlay Requirements. ” Signature Date INSPECTIONS SHALL BE REQUESTED 24 HOURS PRIOR TO COMMENCEMENT OF ALL WORK BY CALLING THE INSPECTION LINE AT 425-430-7203 OR BY GOING TO MYBUILDINGPERMIT.COM Jobs are required to be called in for job start, re-inspection and project final. Re-inspection fees are billed at $75/hour. All Pre-Construction meetings shall be scheduled at a maximum of 14 days prior to the job start date. Plan Review/Development Engineering Date Approved as submitted Pre-Construction Meeting required Site Construction Inspector Date Approved with comments or redlines Camera inspection of utilities required Development Engineering Manager Date VERIZON BUSINESS/MCI METRO SCOTT CHRISTENSON 425.636.6046 SCOTT.CHRISTENSON@VERIZON.COM 601 MONSTER RD, RENTON, WA 98057 VERIZON - 601 MONSTER RD SW 1. TRANSFER AERIAL FIBER ADJACENT TO 601 MONSTER ROAD TO NEW UNDERGROUND CONDUIT PATHWAY PROVIDED BY PROPERTY DEVELOPER. 2. REMOVE DECOMISSIONED AERIAL FIBER PLANT AFTER NETWORK CUT-OVER TO NEW UNDERGROUND FIBER ROUTE IS COMPLETED. 3. REMOVE VACATED UTILITY POLES AND DECOMMISSIONED RISER CONDUITS. North Sky Communications, LLC 601973572 BL.036846 7/18/19 MFP19004101 RESTORATION PER CITY OF RENTON STANDARDSPOTHOLE ALL EXISTING UTILITIES Nathan Janders 7/25/2019 This Permit is for major construction work in the ROW and will be billed at an additional $60/hr for inspections . After hours work and weekend work will be billed at $125/hr Scott Warlick 8/20/2019 CITY OF RENTON TRAFFIC CONTROL PLAN PROJECT NAME: PERMIT# CONSTRUCTION COMPANY: PHONE#: CONTACT NAME: PHONE#: ADDRESS: CELL#: E-MAIL ADDRESS: FAX#: PROJECT LOCATION: N/E/S/W OF: WORK TIME: APPROVED BY: WORK DATE: APPROVAL DATE: OFFICE COPY T- CONTRACTOR DEV. SERVICE, INSPECTION P. MILLER DEV. SERVICE, PLAN REVIEW B. BANNWARTH POLICE CHARLES KARLEWICZ FIRE FIRE MARSHALL FS #13 Permit Holder agrees to all the following: • Comply with all traffic regulations of the City of Renton and the State of Washington. • Prepare a traffic control plan and obtain City approval of that plan. That plan shall be implemented for all street and lane closures, and the plan shall be performed in compliance with the Manual on Uniform Traffic Control Devices. • Notify emergency services (253-852-2121) twenty-four (24) hours before any street or lane closures. • Any lane or street closures not in conformance with the approved traffic control plan and/or without notification of emergency services may result in receiving a citation for violation of R.C.W. 47.36.200 through 47.36.220, 9A.36.050 Reckless Endangerment, and other applicable State and City codes. • Indemnify and hold harmless the City of Renton from any and all claims, actions, and judgments, including all costs of defense and attorney’s fees incurred in defending against same, arising from and related to implementation of the approved traffic control plans including claims arising from towing of private vehicles and the acts of the Permit Holder’s agents and employees. • The City of Renton shall be entitled, in its reasonable discretion, to settle claims prior to suit or judgment, and in such event shall indemnify and hold harmless the City for any such claims paid, including the City’s reasonable attorney’s fees and litigation costs incurred resulting from such claim. • In the event any claim or suit is brought against City within the scope of this Agreement, Permit Holder will pay for legal counsel chosen by the City to defend against same. • Flagger and sign placement are subject to revision by the City Inspector on site, if needed to address traffic or pedestrian safety or travel. • By my signature herein, I acknowledge all the above requirements. PRINT NAME: DATE: SIGNATURE: VERIZON - 601 MONSTER RD SW North Sky Communications, LLC. SCOTT CHRISTENSON 425-636-6046 11311 NE 120TH ST, KIRKLAND WA 98034 SCOTT.CHRISTENSON@VERIZON.COM 601 MONSTER RD SW W OF OAKESDALE AVE SW Reset FormPrint Form CHRISTOPHER MARTINEZ MGC TECHNICAL CONSULTING 7/18/2019 MFP19004101 Monday - Friday 8:00AM - 3:00PM Scott Warlick 8/20/2019 SKETCH I -- NORTH -- I NOTES: • Work Zone Traffic Control shall be in accordance with the Manual on Uniform Traffic Control Devices (MUTCD) and shown by sketch or reference to WSDOT. • The plan must be submitted to the City’s PW/Transportation Division for review and/or approval at least three working days prior to work. • Approved Temporary Traffic Control Plan must be at the work site during work hours. • Contractor or entity must call Renton School District (425-204-4455) or any public/private agency to be affected by a temporary lane or road closure. • Complete assistance and accommodation shall be provided to all kinds of pedestrian traffic when sidewalk or walkway is impeded. • Total road closure lasting more than 24 hours is subject to the approval by the City Council. • Any vehicle, equipment, barricade, or portable tow-away sign used within the work area must display a company logo or any legally acceptable sign showing the company name, address, and telephone number at a conspicuous place on the vehicle or equipment. In the case of Temporary No Parking Zones, all the following apply in addition to previous: • Contractor must complete form to show limits of Temporary No Parking Zone identifying barricade locations for vacate parking or curb lane usage. • Contractor must post notice of dates and time of Temporary No Parking Zone with at least two signs per block 72 hours in advance of effective date and time. • The cover sheet of this Traffic Control Plan form must be attached to each Temporary No Parking Sign on the project site. • Temporary traffic control devices must be removed immediately when work is done or no construction activities are going on. If deemed abandoned, City crews will remove and store them at the City’s maintenance shop (3555 NE 2nd Street). NO.123PROJECT NAME: 601 MONSTER RD SWVERIZON ENGINEER: SCOTT CHRISTENSONENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 601 MONSTER RD SW RENTON, WA 98057DRAWING NAME: VERIZON - 601 MONSTER RD - TCPs.dwgPERMIT NUMBER: CONFIDENTIAL/PROPRIETARYSHEET: OF 13Know what'sbelow.before you dig.CallRSHORT-TERM STATIONARY WORK ZONE - SHOULDER LANE CLOSURE WITH PEDESTRIAN DETOUR (FOR BUSINESS DISTRICT)TRAFFIC CONTROL PLAN #1 - USE SET-UP WHERE APPLICABLE ALONG MONSTER RD SW (EAST BOUND LANE)JURISDICTION TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.LEGEND HIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICES35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTROADWORKAHEADSIGN LEGEND MONSTER RD SW / 35 MPHSCOPE OF WORK:USE WORK AREA TO ACCESS EXISTING VAULT. PULL FIBER AND COPPER CABLE THROUGH.STREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITYWORKVEHICLEWORK AREA 10'X10'555 MONSTER RD SWPARCEL NO.2423049120PARCEL NO.7229500281PARCELNO.7229500310W20-1R7-T39(NO PARKING)PHONE 206-684-5444NAME OF FIRM XXX-XXX-XXXXL/350'-100'R6-1aW20-1W20-301XSHOULDERCLOSEDVERIZON CONTACT:SCOTT CHRISTENSON11311 NE 120TH STKIRKLAND, WA 98034C.425.636.6046SCOTT.CHRISTENSON@VERIZON.COMMFP19004101 NO.123PROJECT NAME: 601 MONSTER RD SWVERIZON ENGINEER: SCOTT CHRISTENSONENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 601 MONSTER RD SW RENTON, WA 98057DRAWING NAME: VERIZON - 601 MONSTER RD - TCPs.dwgPERMIT NUMBER: RIGHTLANECLOSEDAHEADCONFIDENTIAL/PROPRIETARYSHEET: OF 23Know what'sbelow.before you dig.CallRSHORT-TERM STATIONARY WORK ZONE - SINGLE LANE CLOSURE WITH PEDESTRIAN DETOUR (FOR BUSINESS DISTRICT)TRAFFIC CONTROL PLAN #2 - USE SET-UP WHERE APPLICABLE ALONG MONSTER RD SW (EAST BOUND LANE)JURISDICTION TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.LEGEND HIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICES35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTROADWORKAHEADSIGN LEGEND R9-9MONSTER RD SW / 35 MPH601 MONSTER RD SWPARCEL NO.2423049008PARCEL NO.7229500281555 MONSTER RD SWPARCEL NO.2423049120WORKVEHICLEWORK AREA3420 SQ FTR9-11W20-1PLACE SIGN AT INTERSECTIONOF MONSTER RD SW& OAKSDALE AVE SWR9-11PLACE SIGN ATNEAREST INTERSECTION550 MONSTER RD SWPARCEL NO.3779200090L50'-100'W4-2RW20-5RW20-1XXSIDEWALKCLOSEDR9-9SCOPE OF WORK:USE WORK AREA TO COUPLE EXISTING VACANT CONDUIT TO PROPOSED CONDUIT. INSTALL PROPOSED VAULT. BORE AND TRENCH CONDUIT.PULL FIBER AND COPPER CABLE THROUGH. TRANSFER AERIAL FIBER ADJACENT TO 601 MONSTER ROAD SW TO NEW UNDERGROUNDCONDUIT. REMOVE DECOMMISSIONED AERIAL FIBER. REMOVE VACATED UTILITY POLES AND DECOMMISSIONED RISER CONDUITS.STREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITYSIDEWALKCLOSEDAHEADVERIZON CONTACT:SCOTT CHRISTENSON11311 NE 120TH STKIRKLAND, WA 98034C.425.636.6046SCOTT.CHRISTENSON@VERIZON.COMMFP19004101 NO.123PROJECT NAME: 601 MONSTER RD SWVERIZON ENGINEER: SCOTT CHRISTENSONENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 601 MONSTER RD SW RENTON, WA 98057DRAWING NAME: VERIZON - 601 MONSTER RD - TCPs.dwgPERMIT NUMBER: 50'-100'ONE LANEROADAHEADCONFIDENTIAL/PROPRIETARYSHEET: OF 33Know what'sbelow.before you dig.CallRSHORT-TERM STATIONARY WORK ZONE - ONE-LANE, TWO-WAY CLOSURE WITH FLAGGER ON SHOULDER (FOR BUSINESS DISTRICT)TRAFFIC CONTROL PLAN #3 - USE SET-UP WHERE APPLICABLE ALONG MONSTER RD SW (SOUTH BOUND LANE)JURISDICTION TCP REQUIREMENTS1.SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD.2.PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES.3.NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE / BUS ROUTE & STOPIMPACTS.4.MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TOPROTECT WORKERS (RECOMMENDED).5.MAINTAIN 11' VEHICLE TRAVEL LANE WIDTH AT ALL TIMES.6.MAINTAIN 4' OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS.7.MAINTAIN 6' LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING INTHEIR VICINITY.8.FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAINOPEN SIDEWALKS AND ADA RAMPS.9.IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED, CONTRACTOR IS TOPROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH / AROUND STAGING AREA ASDEFINED BY THE MUTCD.10.ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48" BLACK ON FLUORESCENTORANGE UNLESS SPECIFIED OTHERWISE.11.CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD (28" RETROREFLECTIVECONES ARE SUGGESTED).12.ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS ANDDRIVEWAYS.13.STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM & 9AMWEEKDAYS, UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSIONFROM LOCAL DOT AND TC.14.LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROLINTERSECTION TRAFFIC. MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONSON HIGH IMPACT STREETS.15."NO PARKING" SIGNS TO BE PLACED ON CURB SPACE, INCLUDING PAID PARKING.16.CONTRACTOR IS TO COORDINATE / FACILITATE DRIVEWAY / LOADING ZONE ACCESS.17.PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000' OF SIGHT DISTANCE TOAPPROACHING TRAFFIC.18.CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANEOPERATIONS SUCH AS STRIPING, FOG SEAL, ETC. THAT REQUIRE ADDITIONAL PLANSAND DETAILS.LEGEND FLAGGER STATION - FOR VEHICULARAND PEDESTRIAN TRAFFIC CONTROL35 / 40 MPH25 / 30 MPH350' ±200' ±**ALL SIGNS ARE 48" x 48" BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED.RURAL ROADS, URBAN ARTERIALSRESIDENTIAL & BUSINESS DISTRICTSRURAL ROADS & URBAN ARTERIALS45 / 55 MPH500' ±RURAL ROADS60 / 65 MPH800' ±RURAL HIGHWAYS55 / 70 MPHFREEWAYS & EXPRESSWAYS25 MPH or LESS100' ±**URBAN STREETS1500' ±(OR PER THE MUTCD)*ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGERAMPS, AT-GRADE INTERSECTIONS, AND DRIVEWAYS.**ADVANCED WARNING SIGNS IF FEASIBLE.SIGN SPACING = X (FEET)*TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS25303540455055606570MINIMUM LONGITUDINAL BUFFER SPACE = B (FEET)155200250305360425-MINIMUM TAPER LENGTH = L (FEET)POSTED SPEED > 45 MPHPOSTED SPEED < 45 MPHL=W•S (W = LANE WIDTH & S = POSTED SPEED)L=(W•S²)/60 (W = LANE WIDTH & S = POSTED SPEED)POSTED SPEED (MPH)LENGTH (FEET)---ROLL-AHEAD DISTANCE = R (FEET)R = 30' MINIMUM - 100' MAXIMUMMAXIMUM CHANNELIZING DEVICE SPACING (FEET)50 / 7035 / 4525 / 30206080404030POSTED SPEED (MPH)TAPERTANGENTROADWORKAHEADSIGN LEGEND MONSTER RD SW / 35 MPHMONSTER RD SW / 35 MPH OAKSDALE AVE SW / 35 MPH 601 MONSTER RD SWPARCEL NO.2423049008PARCEL NO.91880001301200 MONSTER RD SWPARCEL NO.2423049006951 MONSTER RD SWPARCEL NO.2423049121SCOPE OF WORK:USE WORK AREA TO BORE AND TRENCH CONDUIT. PULL FIBER AND COPPER CABLE THROUGH. ACCESS EXISTING VAULT. TRANSFER AERIAL FIBER ADJACENT TO601 MONSTER ROAD SW TO NEW UNDERGROUND CONDUIT. REMOVE DECOMMISSIONED AERIAL FIBER. REMOVE VACATED UTILITY POLES AND DECOMMISSIONEDRISER CONDUITS. COUPLE EXISTING VACANT CONDUIT TO PROPOSED CONDUIT. ACCESS EXISTING VAULT. PULL FIBER AND COPPER CABLE THROUGH.STREET USE PERMIT #: TBD BY CITYHOURS: TBD BY CITYVERIZON CONTACT:SCOTT CHRISTENSON11311 NE 120TH STKIRKLAND, WA 98034C.425.636.6046SCOTT.CHRISTENSON@VERIZON.COMWORKVEHICLE WORK AREA 10'X10'50'-100'WORK AREA2320 SQ FTR7-T39(NO PARKING)W20-7W20-4W20-1XXW20-7W20-4W20-1X X PHONE 206-684-5444NAME OF FIRM XXX -XXX -XXXXHIGH VISIBILITY WARNING BEACON(REQUIRED)SIGN LOCATION ANDIDENTIFICATION NUMBERW20-1ARROW BOARD - SEQUENTIALCHEVRON MODE (REQUIRED)CHANNELIZING DEVICESR6-1a50'±W20-1W20-4XW20-7XX50'-100'MFP19004101 NO.123PROJECT NAME: 601 MONSTER RD SWVERIZON ENGINEER: SCOTT CHRISTENSONENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 601 MONSTER RD SW RENTON, WA 98057DRAWING NAME: VERIZON - 601 MONSTER RD - PLAN.dwgPERMIT NUMBER: © 2019 Microsoft Corporation © 2019 HERE SITE LOCATIONSHEET INDEXSCOPE OF WORK:1. TRANSFER AERIAL FIBER ADJACENT TO 601MONSTER ROAD TO NEW UNDERGROUNDCONDUIT PATHWAY PROVIDED BY PROPERTYDEVELOPER.2. REMOVE DECOMMISSIONED AERIAL FIBERPLANT AFTER NETWORK CUT-OVER TO NEWUNDERGROUND FIBER ROUTE ISCOMPLETED.3. REMOVE VACATED UTILITY POLES ANDDECOMMISSIONED RISER CONDUITS.Know what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 112CONTACTSMATT FRASERMGC TECHNICAL CONSULTING, INC.6244 185TH AVE NEREDMOND, WA 98052C.206.618.5254MATT@MGCTECHNICAL.COMVERIZON CONTACT:SCOTT CHRISTENSON11311 NE 120TH STKIRKLAND, WA 98034C.425.636.6046SCOTT.CHRISTENSON@VERIZON.COMADDRESS: 601 MONSTER RD SW, RENTON, WA 98057PROJECT NAME: VERIZON - 601 MONSTER RD SW1. COVER SHEET / SITE LOCATION2. LEGEND3. GENERAL NOTES4-9. DESIGN VIEWS A-F10. AERIAL FIBER DEMOLITION PLAN11. UNDERGROUND TYPICALS12. SITE PHOTOGRAPHSSHEET 4SHEET 10SHEET 5SHEET 7SHEET 8SHEET 9SHEET 6MFP19004101 NO.123PROJECT NAME: 601 MONSTER RD SWVERIZON ENGINEER: SCOTT CHRISTENSONENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 601 MONSTER RD SW RENTON, WA 98057DRAWING NAME: VERIZON - 601 MONSTER RD - PLAN.dwgPERMIT NUMBER: Know what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 212#F#F#F##LEGENDMFP19004101 NO.123PROJECT NAME: 601 MONSTER RD SWVERIZON ENGINEER: SCOTT CHRISTENSONENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 601 MONSTER RD SW RENTON, WA 98057DRAWING NAME: VERIZON - 601 MONSTER RD - PLAN.dwgPERMIT NUMBER: GENERAL NOTESKnow what'sbelow.before you dig.CallRGENERAL NOTES:UTILITY LOCATION CENTER AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF EXISTINGAND AT POTENTIAL UTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTINGTHE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALL APPLICABLE AGENCIES. THEDISTURBING ACTIVITY OR CONSTRUCTION ON ANY AND ALL PUBLIC IMPROVEMENTS IF REQUIRED.TO RELOCATIONS OR ADJUSTMENTS OF EXISTING UTILITIES DURING CONSTRUCTION, TO ASSURE THAT THE WORK ISFOR CONTACTING ALL PARTIES AFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE.AND SPECIFICATIONS, AND ONE (1) COPY OF ANY PERMITS AND EXTENSION AGREEMENTS NEEDED FOR THE JOB ON-SITE AT ALLOTHER AFFECTED PARTIES WHICH COULD INDICATE A SITUATION THAT IS NOT IDENTIFIED IN THE PLANS OR SPECIFICATIONS, THECONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY.SPECIFICALLY STATED OTHERWISE.CONTACT THE ENGINEER FOR CLARIFICATION AND NOTE ON THE RECORD DRAWINGS.GROUND DISTURBING ACTIVITY. ALL E.S.C. MEASURES SHALL BE MAINTAINED IN GOOD REPAIR BY THE CONTRACTOR UNTIL SUCHALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE RENTON ENGINEERINGALL CONSTRUCTION OPERATIONS, INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR RUNNING OF TRUCKS, EARTHCONFIDENTIAL/PROPRIETARYSHEET: OF 312The locations of utilities shown on these drawing are only approximate. MGC TECHNICAL CONSULTING, INC. hereby disclaims any responsibilityto third parties for the accuracy of this information. Persons working in the area covered by this drawing must contact the statewideCall-Before-You-Dig System to ascertain the location of underground utilities prior to performing any excavation.ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL MEET OR EXCEED SITE WORKSTANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE RENTON REGULATIONS AND APPLICABLE STATEAND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEEN THESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLESTANDARDS, THE HIGHER QUALITY STANDARD SHALL APPLY. ALL WORK WITHIN PUBLIC R.O.W. OR EASEMENTS MAY REQUIREINSPECTED AND APPROVED BY THE RENTON INSPECTOR. INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TOBE PROVIDED BY DESIGNEE OF PROJECT SPONSOR/OWNER.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES, AS SHOWN ONTHESE PLANS, IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THEFIELD. THE INFORMATION IS NOT TO BE RELIED UPON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE LOCALUTILITIES. THE CONTRACTOR SHALL VERIFY PERTINENT LOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTION POINTSUTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS.CONTRACTOR SHALL NOTIFY THE RENTON INSPECTOR AT LEAST 48 HOURS PRIOR TO THE START OF ANY EARTHTHE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE RENTON AND ALL UTILITY COMPANIES WITH REGARDACCOMPLISHED IN A TIMELY FASHION, AND WITH A MINIMUM DISRUPTION OF SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLETHE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THE APPROPRIATE STANDARDSTIMES.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO: EXCAVATION,TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY.IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THE CONTRACTOR, HIS SUBCONTRACTORS, ORALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD, UNLESSFOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE RENTON, THE CONTRACTOR SHALL SUBMIT ATRAFFIC CONTROL AND PHASING PLAN IN ACCORDANCE WITH M.U.T.C.D. FOR APPROVAL. PRIOR TO ANY CONSTRUCTION ACTIVITIESWITHIN OR AFFECTING THE RIGHT-OF-WAY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFICCONTROL DEVICES AS MAY BE REQUIRED BY SAID PLANS. PRIOR TO INSTALLATION A PRECONSTRUCTION CONFERENCE SHALL BEHELD WITH RENTON.THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THE COMPLETION OF THEINTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS OR DESIGNATED TO BE PROVIDED, INSTALLED, CONSTRUCTED, REMOVEDOR RELOCATED UNLESS SPECIFICALLY NOTED OTHERWISE.PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE AND CLEAR OF ALLCONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE.THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING RECORD INFORMATION ON A SET OF RECORD DRAWINGS KEPT ATTHE CONSTRUCTION SITE AND AVAILABLE TO THE RENTON INSPECTOR AT ALL TIMES.DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FOR ADDITIONAL INFORMATIONALL EROSION AND SEDIMENT CONTROL (E.S.C.) MEASURES SHALL BE INSTALLED AT THE LIMITS OF CONSTRUCTION PRIOR TOTIME AS THE ENTIRE DISTURBED AREAS ARE STABILIZED WITH HARD SURFACE OR LANDSCAPING.DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS.MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATED EQUIPMENT SHALL GENERALLY BE LIMITED TO THETIME PERIOD APPROVED BY THE RENTON.1.2.3.4.5.6.7.8.9.10.11.12.13.14.15.16.AERIAL NOTES1.ALL CONSTRUCTION IS TO BE PREFORMED TO INDUSTRY ACCEPTABLE STANDARDS.2.ALL NEW AERIAL (AND EXISTING) CABLE HEIGHTS OF ATTACHMENTS TO BE DOCUMENTED AT THE TIME OF CONSTRUCTION.3.6.6M STRAND TO BE USED WITH STANDARD 5/8" POLE LINK HARDWARE UNLESS OTHERWISE SPECIFIED BOND STRAND TOPOWER MAIN WHERE APPLICABLE.4.ALL ANCHORS TO BE USED WILL BE 3/4" SCREW TYPE5.IT IS THE CONTRACTORS RESPONSIBILITY TO MAINTAIN AND FOLLOW ALL NESC ALONG WITH APPLICABLE LOCAL & REGIONALGOVERNING AUTHORITIES. ANY DISCREPANCIES BETWEEN THESE AUTHORITIES AND OR THE CONSTRUCTION PRINTS IS TO BEVALIDATED WITH THE DESIGNER OR OWNER PRIOR TO CONSTRUCTION.6.ALL PVC OR HDPE CONDUITS ARE TO BE PLUGGED WITH COMPRESSION STYLE PLUGS. ANY CONDUITS CONTAINING FIBERCABLE REQUIRE SIMPLEX COMPRESSION PLUGS SEALING THE CONDUIT AROUND THE CABLE.MFP19004101 NO.123PROJECT NAME: 601 MONSTER RD SWVERIZON ENGINEER: SCOTT CHRISTENSONENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 601 MONSTER RD SW RENTON, WA 98057DRAWING NAME: VERIZON - 601 MONSTER RD - PLAN.dwgPERMIT NUMBER: CONFIDENTIAL/PROPRIETARYSHEET: OF 412CONSTRUCTION NOTES1EXISTING MCI/VERIZON MANHOLE. PULL NEW FIBER CABLETHROUGH.DESIGN VIEW A Know what'sbelow.before you dig.CallRBEACON COAL MINE RD S2EXISTING (2) 4" CONDUITS. PULL NEW FIBER CABLETHROUGH (1) VACANT 4" CONDUIT. WRECK OUT (1)DECOMMISSIONED FIBER CABLE FROM (1) OCCUPIEDCONDUIT AFTER NETWORK CUT-OVER TO NEW FIBERCABLE.MONSTER RD SW12STATION LINE 170' 12' 35' 56'3'95'266'13' 12' 12' 12' 7' MATCH TO SHEET 5 PARCEL NO.7229500281555 MONSTER RD SWPARCEL NO.2423049120MFP19004101 NO.123PROJECT NAME: 601 MONSTER RD SWVERIZON ENGINEER: SCOTT CHRISTENSONENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 601 MONSTER RD SW RENTON, WA 98057DRAWING NAME: VERIZON - 601 MONSTER RD - PLAN.dwgPERMIT NUMBER: CONFIDENTIAL/PROPRIETARYSHEET: OF 512CONSTRUCTION NOTESDESIGN VIEW B Know what'sbelow.before you dig.CallR2EXISTING (2) 4" CONDUITS. PULL NEW FIBER CABLETHROUGH (1) VACANT 4" CONDUIT. WRECK OUT (1)DECOMMISSIONED FIBER CABLE FROM (1) OCCUPIEDCONDUIT AFTER NETWORK CUT-OVER TO NEW FIBERCABLE.MATCH T O S H E E T 62STATION LINE 1MATCH TO SHEET4MONSTER RD SWBEACON COAL MINE RD S550 MONSTER RD SWPARCEL NO.3779200090PARCEL NO.7229500281555 MONSTER RD SWPARCEL NO.2423049008 601 MONSTER RD SWPARCEL NO.2423049008333'16'70' 12' 58' 4' 35' 12'12' 12'18' 6'MFP19004101 NO.123PROJECT NAME: 601 MONSTER RD SWVERIZON ENGINEER: SCOTT CHRISTENSONENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 601 MONSTER RD SW RENTON, WA 98057DRAWING NAME: VERIZON - 601 MONSTER RD - PLAN.dwgPERMIT NUMBER: CONFIDENTIAL/PROPRIETARYSHEET: OF 612Know what'sbelow.before you dig.CallRCONSTRUCTION NOTES#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #14 FOR SITE PHOTOGRAPHS.MATCH TO SHEET 5 MATCH TO SHEET 7DESIGN VIEW C 601 MONSTER RD SWPARCEL NO.2423049008MONSTER RD SW80' 12' 30' 40' 5' 23'10'PARCEL NO.7229500281PARCEL NO.1323049078SW 7TH ST2EXISTING (2) 4" CONDUITS. PULL NEW FIBER CABLETHROUGH (1) VACANT 4" CONDUIT. WRECK OUT (1)DECOMMISSIONED FIBER CABLE FROM (1) OCCUPIEDCONDUIT AFTER NETWORK CUT-OVER TO NEW FIBERCABLE.233COUPLE (1) EXISTING VACANT 4" CONDUIT TO (1)PROPOSED 4" CONDUIT. PULL NEW FIBER CABLETHROUGH. AFTER OLD FIBER CABLE IS WRECKED OUT OFOCCUPIED 4" CONDUIT: COUPLE PREVIOUSLY OCCUPIED 4"CONDUIT TO (1) PROPOSED 4" CONDUIT. VERIZON TOPERFORM CABLE WRECKOUT AND CONDUITCONNECTIONS. LOCATE EXISTING CONDUITS PRIOR TOCONSTRUCTION.44PROPOSED (2) 4" CONDUITS BY PENNON CONSTRUCTIONFOR USE BY VERIZON. CONDUITS SHALL BE PLACED WITH36" COVER WHERE POSSIBLE WITH MINIMUM 36" RADIUSBENDS. SURFACE RESTORATION TO BE PERFORMED BYPENNON CONSTRUCTION UNDER THE 601 MONSTERROAD PROJECT.455PROPOSED 24"X36" HANDHOLE PLACED BY PENNONCONSTRUCTION FOR USE BY VERIZON. VERIZON TO PULLNEW FIBER CABLE THROUGH. SEE TYPICAL DETAILS SHEETFOR HANDHOLE DETAIL.19'6'311'71'1' 2' 6'6'2'8' 35'STATION LINE 1if work vehicles areneeded to be in theROW and/or if thesidewalk isrestrictedadditional trafficcontrol is required.RESTORATION PER CITY OF RENTON STANDARDSPOTHOLE ALL EXISTING UTILITIESMFP19004101 NO.123PROJECT NAME: 601 MONSTER RD SWVERIZON ENGINEER: SCOTT CHRISTENSONENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 601 MONSTER RD SW RENTON, WA 98057DRAWING NAME: VERIZON - 601 MONSTER RD - PLAN.dwgPERMIT NUMBER: CONFIDENTIAL/PROPRIETARYSHEET: OF 712Know what'sbelow.before you dig.CallRCONSTRUCTION NOTES#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #14 FOR SITE PHOTOGRAPHS.MATCH TO SHEET 6MATCH TO SHEET8DESIGN VIEW D 601 MONSTER RD SWPARCEL NO.2423049008MONSTER RD SW MONSTER RD SW61'30'21'12'13'15'80' 40' 10' 11'PARCEL NO.1323049078SW 7TH STPARCEL NO.91880001301200 MONSTER RD SWPARCEL NO.242304900613'34'7'PARCEL NO.91880001304PROPOSED (2) 4" CONDUITS BY PENNON CONSTRUCTIONFOR USE BY VERIZON. SURFACE RESTORATION TO BEPERFORMED BY PENNON CONSTRUCTION UNDER 601MONSTER ROAD PROJECT.428'86'1'40'STATION LINE 1STATION LINE 2RESTORATION PER CITY OF RENTON STANDARDSPOTHOLE ALL EXISTING UTILITIESMFP19004101 NO.123PROJECT NAME: 601 MONSTER RD SWVERIZON ENGINEER: SCOTT CHRISTENSONENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 601 MONSTER RD SW RENTON, WA 98057DRAWING NAME: VERIZON - 601 MONSTER RD - PLAN.dwgPERMIT NUMBER: CONFIDENTIAL/PROPRIETARYSHEET: OF 812CONSTRUCTION NOTESMATCH TO SHEET7DESIGN VIEW E CONTRACTOR NOTES1.ALL EXCAVATION WITHIN DRIP LINE OF TREE SHALL BECOMPLETED VIA VAC TRUCK. PROTECT ROOTS GREATER THAN2" WITH BURLAP. REMOVE BURLAP AFTER CONSTRUCTION.(WHEN WORKING WITHIN DRIP LINE OF TREES)2.LOCATE AND PROTECT ALL GASFACILITIES. MAINTAIN 1’ VERTICAL AND 3’ HORIZONTALCLEARANCE WHEN WORKING NEAR EXISTING GAS FACILITIES.3.LOCATE AND PROTECT ALL STREET LIGHT INFRASTRUCTUREPRIOR TO CONSTRUCTION.Know what'sbelow.before you dig.CallR#SYMBOL CORRESPONDS TO PHOTO LOCATIONS ANDORIENTATION. SEE SHEET #14 FOR SITE PHOTOGRAPHS.60' 30' 17' MATCH TO SHEET 9 12'12'13'JACKSON PL SW 601 MONSTER RD SWPARCEL NO.24230490081200 MONSTER RD SWPARCEL NO.B2423049006PARCEL NO.2423049044MONSTER RD SW42EXISTING (2) 4" CONDUITS. PULL NEW FIBER CABLETHROUGH (1) VACANT 4" CONDUIT. WRECK OUT (1)DECOMMISSIONED FIBER CABLE FROM (1) OCCUPIEDCONDUIT AFTER NETWORK CUT-OVER TO NEW FIBERCABLE.3COUPLE (1) EXISTING VACANT 4" CONDUIT TO (1)PROPOSED 4" CONDUIT. PULL NEW FIBER CABLETHROUGH. AFTER OLD FIBER CABLE IS WRECKED OUT OFOCCUPIED 4" CONDUIT: COUPLE PREVIOUSLY OCCUPIED 4"CONDUIT TO (1) PROPOSED 4" CONDUIT. VERIZON TOPERFORM CABLE WRECKOUT AND CONDUITCONNECTIONS. LOCATE EXISTING CONDUITS PRIOR TOCONSTRUCTION.4PROPOSED (2) 4" CONDUITS BY PENNON CONSTRUCTIONFOR USE BY VERIZON. SURFACE RESTORATION TO BEPERFORMED BY PENNON CONSTRUCTION UNDER 601MONSTER ROAD PROJECT.3234115'235'22'18' 2' 2' 2' 4' 13'STATION LINE 24' 1'pothole requiredwhen crossingutilities. coordinatewith privateproperty ownertraffic control andrestorationthis property is vacant land, but has adriveway for the adjacent business. Icouldn't find an easement or otherdocument dictating ownershipRESTORATION PER CITY OF RENTON STANDARDSPOTHOLE ALL EXISTING UTILITIESMFP19004101 NO.123PROJECT NAME: 601 MONSTER RD SWVERIZON ENGINEER: SCOTT CHRISTENSONENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 601 MONSTER RD SW RENTON, WA 98057DRAWING NAME: VERIZON - 601 MONSTER RD - PLAN.dwgPERMIT NUMBER: CONFIDENTIAL/PROPRIETARYSHEET: OF 912CONSTRUCTION NOTESMATCH TO SHEET 8DESIGN VIEW F Know what'sbelow.before you dig.CallRJACKSON PL SW951 MONSTER RD SWPARCEL NO.24230491211200 MONSTER RD SWPARCEL NO.242304900660' 30' 8' 17' 5' 11'10' 601 MONSTER RD SWPARCEL NO.2423049008MONSTER RD SW1EXISTING MCI/VERIZON MANHOLE. PULL NEW FIBER CABLETHROUGH.2EXISTING (2) 4" CONDUITS. PULL NEW FIBER CABLETHROUGH (1) VACANT 4" CONDUIT. WRECK OUT (1)DECOMMISSIONED FIBER CABLE FROM (1) OCCUPIEDCONDUIT AFTER NETWORK CUT-OVER TO NEW FIBERCABLE.2192'11'STATION LINE 25'4'MFP19004101 NO.123PROJECT NAME: 601 MONSTER RD SWVERIZON ENGINEER: SCOTT CHRISTENSONENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 601 MONSTER RD SW RENTON, WA 98057DRAWING NAME: VERIZON - 601 MONSTER RD - PLAN.dwgPERMIT NUMBER: CONFIDENTIAL/PROPRIETARYSHEET: OF 1012CONSTRUCTION NOTESDESIGN VIEW G - AERIAL DEMOLITION PLAN Know what'sbelow.before you dig.CallR149'550 MONSTER RD SWPARCEL NO.3779200090555 MONSTER RD SWPARCEL NO.2423049120PARCEL NO.7229500281 601 MONSTER RD SWPARCEL NO.2423049008PARCEL NO.1323049078PARCEL NO.91880001301200 MONSTER RD SWPARCEL NO.2423049006MONSTER RD SWMONSTER RD SW6VERIZON TO REMOVE EXISTING FIBER AND STRANDBETWEEN EXISTING UTILITY POLES AFTER NETWORKCUT-OVER TO NEW UNDERGROUND FIBER ROUTE.6666877787VERIZON TO REMOVE EXISTING UTILITY POLE.8VERIZON TO REMOVE EXISTING UTILITY POLE & (2)DECOMMISSIONED 4" CONDUIT RISERS.104'215'258'MFP19004101 NO.123PROJECT NAME: 601 MONSTER RD SWVERIZON ENGINEER: SCOTT CHRISTENSONENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 601 MONSTER RD SW RENTON, WA 98057DRAWING NAME: VERIZON - 601 MONSTER RD - PLAN.dwgPERMIT NUMBER: UNDERGROUND TYPICALSKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 1112FCA243624T-00006FIBERGLASS / POLYMER CONCRETEASSEMBLYInside DimensionsLengthWidthDepth33 3\8"44 1\4"21 1\2"32 5\8"21"2626 Kansas AvenueRiverside, California 92507951.787.0600951.787.0632 (fax)info@newbasis.comnewbasis.comComposites for InfrastructureAdditional product informationcontinued on the reverseFEATURES: UL classified polymer concrete Drop-in nameplate Shipped assembled Skid resistant cover Stainless steel bolts Cast-in floating nut box - Integral drain holesLOAD RATINGSIncidental traffic - Parking Lot, SidewalkConforms to: WUC 3.6 ASTM C 857 ANSI/SCTE 77Fiberglass/ Polymer Concrete Assembly,Tapered Sides, No Floor, WUC 3.6,ANSI/SCTE 77-"T15/20K, "3/8 " HexBolts, Standard Nameplate (Specify attime of order) Installed24"X36"X24"(For actual dimensions see drawing)3"24"35 5/8"26 1/4"37 7/8"24"NB2436 HANDHOLE DETAILNON SKID SURFACEMFP19004101 NO.123PROJECT NAME: 601 MONSTER RD SWVERIZON ENGINEER: SCOTT CHRISTENSONENGINEERING FIRM: MGC TECHNICAL CONSULTING INC.LOCATION: 601 MONSTER RD SW RENTON, WA 98057DRAWING NAME: VERIZON - 601 MONSTER RD - PLAN.dwgPERMIT NUMBER: SITE PHOTOGRAPHSKnow what'sbelow.before you dig.CallRCONFIDENTIAL/PROPRIETARYSHEET: OF 1212CONSTRUCTION NOTESPHOTO #1: FACING EAST ON SOUTH SIDE OF MONSTER RD SWPHOTO #2: FACING SOUTHEAST ON THE SOUTH SIDE OF MONSTER RD SWPHOTO #3: FACING SOUTH ON WEST SIDE OF MONSTER RD SWPHOTO #4: FACING SOUTH ON WEST SIDE OF MONSTER RD SW1EXISTING MCI/VERIZON MANHOLE. PULL NEW FIBER CABLETHROUGH.2EXISTING (2) 4" CONDUITS. PULL NEW FIBER CABLETHROUGH (1) VACANT 4" CONDUIT. WRECK OUT (1)DECOMMISSIONED FIBER CABLE FROM (1) OCCUPIEDCONDUIT AFTER NETWORK CUT-OVER TO NEW FIBERCABLE.3COUPLE (1) EXISTING VACANT 4" CONDUIT TO (1)PROPOSED 4" CONDUIT. PULL NEW FIBER CABLETHROUGH. AFTER OLD FIBER CABLE IS WRECKED OUT OFOCCUPIED 4" CONDUIT: COUPLE PREVIOUSLY OCCUPIED 4"CONDUIT TO (1) PROPOSED 4" CONDUIT. VERIZON TOPERFORM CABLE WRECKOUT AND CONDUITCONNECTIONS. LOCATE EXISTING CONDUITS PRIOR TOCONSTRUCTION.4PROPOSED (2) 4" CONDUITS BY PENNON CONSTRUCTIONFOR USE BY VERIZON. CONDUITS SHALL BE PLACED WITH36" COVER WHERE POSSIBLE WITH MINIMUM 36" RADIUSBENDS. SURFACE RESTORATION TO BE PERFORMED BYPENNON CONSTRUCTION UNDER THE 601 MONSTERROAD PROJECT.5PROPOSED 24"X36" HANDHOLE PLACED BY PENNONCONSTRUCTION FOR USE BY VERIZON. VERIZON TO PULLNEW FIBER CABLE THROUGH. SEE TYPICAL DETAILS SHEETFOR HANDHOLE DETAIL.2345444321MFP19004101