ABBREVIATIONS
� GENERAL CONSTRUCTION NOTES:
p
1. ALL WORK, WORKMANSHIP AND MATERIALS FOR THIS PROJECT SHALL MEET OR
p EXCEED THE MOST CURRENT VERSION OF THE WSDOT STANDARD SPECIFICATIONS
FOR ROAD, BRIDGE, AND MUNICIPAL CONSTRUCTION. IF THERE IS A CONFLICT
BETWEEN THE SPECIFICATIONS, THE MOST RESTRICTIVE REFERENCE SHALL BE
ADHERED TO.
W
F.— 2. ALL GOVERNMENTAL SAFETY REGULATIONS SHALL BE STRICTLY ADHERED TO
INCLUDING OSHA, WISHA AND WASHINGTON DEPARTMENT OF LABOR AND INDUSTRY.
3. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO DULY NOTIFY THE CITY IN
ADVANCE OF THE COMMENCEMENT OF ANY AUTHORIZED WORK AND TO SCHEDULE
REQUIRED INSPECTIONS. ANY REQUIRED INSPECTION TEST WILL BE PERFORMED AT
THE CONTRACTOR'S EXPENSE.
4. THE CONTRACTOR SHALL PROVIDE A TWO—YEAR WARRANTY ON ALL WORKMANSHIP
AND MATERIAL FOLLOWING ACCEPTANCE OF THE PROJECT BY THE OWNER.
5. THE APPROVAL OF THESE PLANS BY THE CITY OF RENTON DOES NOT RELIEVE THE
CONTRACTOR OR DEVELOPER OF THE RESPONSIBILITY TO COMPLY WITH THE
REQUIREMENTS OF OTHER GOVERNING AGENCIES.
6. CAUTION — NOTICE TO CONTRACTOR
THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION OF EXISTING
UTILITIES AS SHOWN ON THESE PLANS IS BASED ON THE PROJECT SURVEY AND
OTHER RECORDS OF UTILITIES. THE INFORMATION IS NOT TO BE RELIED ON AS
BEING EXACT OR COMPLETE. THE CONTRACTOR SHALL CALL 1-800-424-5555 48
HOURS PRIOR TO PLANNED EXCAVATIONS.
7. THE DESIGN SHOWN IS BASED UPON THE ENGINEER'S UNDERSTANDING OF THE
EXISTING CONDITIONS. THE EXISTING CONDITIONS SHOWN ON THIS PLAN SHEET ARE
BASED UPON COMPILED SURVEY DATA. THE CONTRACTOR IS RESPONSIBLE FOR
VERIFYING FIELD CONDITIONS PRIOR TO BIDDING THE PROPOSED WORK
IMPROVEMENTS. IF CONFLICTS ARE DISCOVERED, THE CONTRACTOR SHALL NOTIFY
THE OWNER OR OWNER'S REPRESENTATIVE.
8. EXISTING UTILITIES ARE SHOWN FOR REFERENCE ONLY. THE CONTRACTOR SHALL
VERIFY EXACT LOCATION, DIA, LENGTH, CONDITION, PIPE TYPE, SLOPE AND VERTICAL
AND HORIZONTAL ALIGNMENT OF THE EXISTING ALIGNMENT OF THE PROPOSED
POINTS OF CONNECTION PRIOR TO CONNECTION AND REPORT ANY DISCREPANCIES
TO ENGINEER PRIOR TO CONSTRUCTION.
9. PRIOR TO COMMENCING WORK, THE CONTRACTOR SHALL OBTAIN ALL NECESSARY
LOCAL, STATE, AND FEDERAL APPROVALS AND PERMITS.
10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO HAVE A COPY OF THE
APPROVED PLANS, SPECIFICATIONS, AND CONTRACT DOCUMENTS AT THE
CONSTRUCTION SITE AT ALL TIMES.
11.THE CONTRACTOR SHALL PROVIDE SLOPE PROTECTION FOR SLOPES OF 5:1 OR
GREATER ACCORDING TO AGC STANDARD GUIDELINES AND BEST MANAGEMENT
PRACTICES (BMP'S).
12. THE CONTRACTOR SHALL MAINTAIN EROSION CONTROL FACILITIES IN ACCORDANCE
WITH THE DEPARTMENT OF ECOLOGY STORM WATER MANUAL, THE CITY OF RENTON
SURFACE WATER DESIGN MANUAL AND THE STORMWATER POLLUTION PREVENTION
PLAN (SWPPP).
13. THE CONTRACTOR SHALL SAFELY MAINTAIN TRAFFIC AND CONTINUOUS ACCESS TO
PRIVATE AND/OR PUBLIC PROPERTY.
14. CONSTRUCTION SIGNING AND TRAFFIC CONTROL SHALL BE PER THE CURRENT COPY
OF THE MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) AND PER THE
APPROVED TRAFFIC CONTROL PLAN.
15. ALL VEHICLES AND EQUIPMENT SHALL BE KEPT WITHIN THE WORK AREAS
ESTABLISHED FOR THAT WORK SHIFT UNLESS TRAVELING TO OR FROM THE SITE.
UNDER NO CIRCUMSTANCES SHALL VEHICLES BE PARKED OR EQUIPMENT BE STORED
OUTSIDE OF THESE AREAS.
16.OTHER CONSTRUCTION PROJECTS MAY OCCUR NEAR THE PROJECT SITE AND MAY BE
IN PROGRESS CONCURRENT WITH THE PROJECT. THE CONTRACTOR SHALL
COOPERATE AS NECESSARY AND NOT INTERFERE OR HINDER THE PROGRESS OR
COMPLETION OF WORK BEING PERFORMED BY OTHER CONTRACTORS.
17. THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING ALL MATERIALS,
LABOR, AND EQUIPMENT NECESSARY TO COMPLETE THE WORK SHOWN ON THESE
DRAWINGS AND TO OBTAIN ACCEPTANCE BY THE CITY OF RENTON AND THE
PROJECT OWNER.
18. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO THEIR
ORIGINAL "PRE CONSTRUCTION" STATE OR BETTER.
19. DRIVEWAY ACCESS AND UTILITY SERVICE TO EXISTING HOMES AND BUSINESSES
0
SHALL BE MAINTAINED AT ALL TIMES.
Z 20. GROUNDWATER EXIST ON —SITE, SEE GEOTECHNICAL ENGINEERING STUDY BY EARTH
CD SOLUTIONS NW, LLC, DATED AUGUST 3, 2017
NJ
O
CO
00
K0
CV
0
0
Ld
U
Ld
m
m
Z
W
(/)
Q
2
CL
Z
V)
0
0
z
w
cn
0
z
w
C M
N O
N C+O
3 C14
0 j
U �
L Z
w
N a-
� 0
uj
CALL BEFORE YOU DIG
CD co THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE LOCATION
N CV AND PROTECTION OF ALL EXISTING UTILITIES. THE CONTRACTOR SHALL
cn VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION BY CALLING
THE UNDERGROUND LOCATE LINE AT (800) 424-5555 A MINIMUM OF
48 HOURS PRIOR TO ANY EXCAVATION.
�Z
55D-�gR
�O� �F WASF/I c�js
�P O
cn Z
o'
O4366
AS �FGI STEREO
S10NAL
06/19/20191 NO.
REFER To R,,4036149
IWi403601 , So*403601 FOR
AS -BUILT INFORMATION
BUILDING PERMIT SUBMITTAL
BUILDING PERMIT SUBMITTAL
REVISION
R.E.W. 05/01/191 R.D.J. suRVEYEO:
R.E.W. 06 19 19 R.D.J. DESIGNED:
K. MELVIN
DRAWN:
S. ORDONEZ
CHECKED:
R. JARVIS
BY DATE APPR APPROVED:
R. JARVIS
&
AND
FDC
FIRE DEPARTMENT CONNECTION
D
ANGLE
FDN
FOUNDATION
t
APPROXIMATELY
FES
FLARED END SECTION
®
AT
FF
FINISH FLOOR
CENTERLINE
FG
FINISH GRADE ELEVATION
'
DEGREE
FH
FIRE HYDRANT
=
EQUALS
FIN
FINISH(ED)
'
FOOT
FL
FIRE LINE/FLANGE
>
GREATER THAN
FT
FOOT/FEET
"
INCH
#
NUMBER
G
GAS
%
PERCENT
GALV
GALVANIZED
GB
GRADE BREAK
AC
ASPHALTIC CONCRETE
GRND
GROUND
ADD'L
ADDITIONAL
GV
GATE VALVE
ADJT
ADJACENT
AFF
ABOVE FINISH FLOOR
HH
HANDHOLE
AP
ANGLE POINT
HP
HIGH POINT ELEVATION
APPROX
APPROXIMATE
HORIZ
HORIZONTAL
ARCH
ARCHITECT
HT
HEIGHT
ATB
ASPHALT TREATED BASE COURSE
IE
INVERT ELEVATION
AVE
AVENUE
IN
INCH
BC
BOTTOM OF CURB ELEVATION
JB, J—BOX
JUNCTION BOX
BCR
BEGIN CURB RETURN
JT
JOINT TRENCH
BFV
BUTTERFLY VALVE
BGS
BELOW GROUND SURFACE
kV
KILOVOTS
BLK
BLOCK(S)
kW
KILOWATT
BLDG
BUILDING
KWH
KILOWATT HOURS
BM
BENCHMARK
L
LENGTH
BVC
BEGIN VERTICAL CURB
BW
BOTTOM OF WALL ELEVATION
LB(S)
POUND(S)
C
CONDUIT
LF
LINEAR FEET
CB
CATCH BASIN
LP
LOW POINT ELEVATION
CF
CUBIC FEET
LT
LEFT
CIRC
CIRCUIT, CIRCULAR, TION)
MAX
MAXIMUM
CIP
CAST —IN —PLACE
MFR
MANUFACTURER
CIP MON
CAST —IN —PLACE MONUMENT
MH
MANHOLE
CJ
CENTER JOINT
MIN
MINIMUM, MINUTE
CENTER LINE
MISC
MISCELLANEOUS
CL
CROWNLINE
MON
MONUMENT IN CASE
CLR
CLEAR
CO
CLEANOUT
N
NORTH, NORTHING
COMM
COMMUNICATION
N/A
NOT APPLICABLE
COMPT
COMPACTED
NE
NORTHEAST
CONC
CONCRETE
NEMA
NATIONAL ELECTRICAL MANUFACTURES
CONST
CONSTRUCT
ASSOCIATION
CONT
CONTINUE, ED, OUS, ATION)
NIC
NOT IN CONTRACT
COORD
COORDINATE
NO, No
NUMBER
CSBC
CRUSHED SURFACING BASE COURSE
NTS
NOT TO SCALE
CSTC
CRUSHED SURFACING TOP COURSE
NW
NORTHWEST
CULV
CULVERT
OC, oc
ON CENTER
CU YD
CUBIC YARD
OD
OUTSIDE DIAMETER
D/W
DRIVEWAY
OSHA
OCCUPATIONAL SAFETY & HEALTH
DEF
DEFLECTION
ADMINISTRATION
DEG
DEGREE
P
POWER, POWER VAULT
DEMO
DEMOLISH/DEMOLITION
PC
POINT OF CURVATURE
DIA
DIAMETER
PCC
POINT OF COMPOUND CURVE
DIM
DIMENSION(S)
PED
PEDESTAL
DIP
DUCTILE IRON PIPE
PI
POINT OF INTERSECTION
DR
DRIVE
R
PROPERTY LINE
DWG(S)
DR WINGS)
POC
POINT OF CONNECTION
E
EAST OR ELECTRICAL
PP
POWER POLE
EA
EACH
PRC
POINT OF REVERSE CURVATURE
ECR
END CURB RETURN
PROP
PROPERTY
EHH
ELECTRICAL HANDHOLE
PSE
PUGET SOUND ENERGY
EL, ELEV
ELEVATION
PSI
POUNDS PER SQUARE INCH
ELEC
ELECTRIC(AL)
PT
POINT OF TANGENCY
ENGR
ENGINEER
PVC
POINT OF VERTICAL CURVE
EOP
EDGE OF PAVEMENT
PVI
POINT OF VERTICAL INTERSECTION
EQ
EQUAL(LY)
PVT
POINT OF VERTICAL TANGENT
EQUIP
EQUIPMENT
PVMT
PAVEMENT
ESMT
EASEMENT
PWR
POWER
EVC
END VERTICAL CURVE
QTY
QUANTITY
EX, EXIST
EXISTING
EXP
EXPANSION
1 "=1 '
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
R
RADIUS
RD
ROAD, ROADWAY
REF
REFERENCE
REINF
REINFORC(E, ED, ING, MENT)
REQ'D
REQUIRED
REV
REVISION
RIM
STRUCTURE RIM ELEVATION
RT
RIGHT
R/W, ROW
RIGHT OF WAY
S
SOUTH OR SLOPE
SCHED
SCHEDULE
SD, SDMH
STORM DRAIN, STORM DRAIN MANHOLE
SE
SOUTHEAST
SECT
SECTION(S)
SHT
SHEET
SP
SPRINKLER
SQ
SQUARE
SQ FT
SQUARE FEET
SQ IN
SQUARE INCH
SS
SANITARY SEWER
SSMH
SANITARY SEWER MANHOLE
ST
STREET
STA
STATION
STD
STANDARD
STRUCT
STRUCTURE(E, AL)
SW
SOUTHWEST
SYS
SYSTEM
T
TELEPHONE OR TELEPHONE VAULT
TBD
TO BE DETERMINED
TBM
TEMPORARY BENCH MARK
TC
TOP OF CURB ELEVATION
TELE
TELEPHONE
TEMP
TEMPORARY
TW
TOP OF WALL ELEVATION
TP, T/P
TOP OF PIPE
TYP
TYPICAL
UDG
UNDERGROUND
VAP
VERTICAL ANGLE POINT
VC
VERTICAL CURVE
VERT
VERTICAL
VOL
VOLUME
W
WEST, WIDTH, WIDE OR WATER
W/
WITH
W/0
WITHOUT
WM
WATER MAIN OR WILLAMETTE MERIDIAN
WSDOT
WASHINGTON STATE DEPARTMENT OF
TRANSPORTATION
WV
WATER VALVE
XFMR TRANSFORMER
R-403602
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
HORIZONTAL NAD 1983/1991 CITY 0 F FIELDBOOK:
,.T WEATHERLY INN RENTON
RENTON 4500 TALBOT RD S PAGE.
RENTON, WA 98055 DRAWING NO:
DATUM Planning/Building/Public Works Dept. GN-01
GENERAL NOTES AND LEGEND
SHEET. 2 OF:51