Loading...
HomeMy WebLinkAboutR-4036150 s I C, NJ O co 00 K0 0 0 Q Ld m Z L,LJ Q i Z V) 0 o' 0 z w cn 0 z LLj Q>C)o 0 L� z w N a- � o LLJ E L� 0 n U-)� ,I- 0:� u')co dc5 rn N 0 N LJJ �p O N a_ �Z _-_T�_ ---�- -,�I, __--_:___----- _-===== �_______________ _____ _ _ _=------- _=---------170= - = 170-- -- _==_= ' II a II ----------------- CD o II r - - - - _ /--90 LF OF 12" ®0.94% _ - _ - _ - _ _ _;; II + II II CB #g CB #6 , I _ - (SEE STORM PROFILE #1) STA: 3+65.69, 0.00' 4+0 _ , 5+00 . _ SEE STO M' P OFlLE 1 6+00 - STA: 6+34.19, 0.00' ' o II II CATCH BASIN TYPE 1 _ _ CATCH BASIN TYPE 1 ; II I I ; 1 S OF 12 0.91 ,r- - W/ VANED GRATE M- M ' W/ BI-DIRECTIONAL VANED GRATE II II RIM:173.35 CB #7 RIM:177.38 I I; o II II - IE IN:170.40 (12" E) sS STA:4+56.16, 0.02' RT - ss SS Ss ss IE IN:172.87 (12" S) II II I I IE OUT:170.40 (12 S)' ,� CATCH BASIN TYPE 2 - - - _ _ IE OUT:172.87 (12 W) W/ VANED GRATE " -I RIM-177.06 43 LF OF 12 ®0.50% , ' II ,g` I W �IE IN:171.25 (12" E) (SEE STORM PROFILE #1) II II CB #10 ' a�r1 h IE OUT:171.25 (12" W) 1 RD RD RD; ��'4' STA: 2+36.43, 0.00 CB #5 ' _ I L ' 1 CATCH BASIN TYPE 1 ,' ` - y ''' STA: 6+77.31, 0.02' LT ' T- 1 W/ VANED GRATE �' o CATCH BASIN TYPE 2 RIM:I / o ' , ,, c�D.�•jI p -__� I 172.11 >� I " + W/ SOLID LID 2 63 LF OF 12 (� 0.51% r- ' :}I F 3 III• :I .'� { IE IN:168.00 (12 NE) �o CB #g RIM:178.58 , IE IN:168.00 12" N N SS �� (SEE STORM PROFILE #1) , °: { CB #22 i ( ) `STA: 0+25.67, 0.00 _ IE IN:173.08 (12 S) , +t ; III.;I ' STA: 0+72.65, 0.00' IE OUT:168.00 (12" SW) , ``` CATCH BASIN TYPE 1 / ---� IE OUT:173.09 (12" N) ; CATCH BASIN TYPE 2 `J W/ VANED GRATE IDS W/ SOLID LID ^�c� 23 LF OF 12" (� 6.00% - RIM:177.23 _ �-w i , _ = I I RIM:163.03 CB 11 w� IE OUT.172.73 (12" SW) IE IN:154.68 (12 S) STA:2+13.62, 0.01 LT �, 1 ' ' RD �1' F OF 3 39% - I -', •'' ,' ; 1 NCI. I IE OUT:154.68 (12" W) , CATCH BASIN TYPE 1 � 9 / - � bm Cu #23 W/ VANED GRATE a F �' ----- �c, ' STA:1+62.33, 0.00' ; �� STA:0+92.55, 0.00' . RIM:170.93 �N,Q �1 o STA:7+40.37, 0.12' LT r CATCH BASIN TYPE 1 ; , - EX. CATCH BASIN TYPE 1 IE IN:166.63 (12 NE) 5, o - Q:f CATCH BASIN TYPE 1 olll �� " ����- � � 'I -� - � W/ SOLID LID RIM:156.04 N `ram W/ VANED GRATE IE OUT:166.63 (12 W) a N. >9 _ , " in RIM: .' IE IN:154.32 (12 S) RIM: 1 FEE-:179'0 N , " , �- ; "ifbyas o o - IE IN.173.40 (12 S) IE IN:154.04 (12" E) ` IE IN:159.15 (12" E)_ IE IN:173.40 (8" W) IE OUT:154.27 12 N �, L S �� ''-' 'o " ( ) cn 2 IE OUT:159.15 (12 S) �� _ _ _ _ -� �- IE OUT:173.40 (12 N) -' S M P 2) ' 12 LF OF 12" ® 0.50% o CB #19 (SEE STORM PROFILE #2)� S / STA:12+22.30, 334.05' RT _ LINE o T-,�o / TYPE 50 AREA DRAIN - o I ' 88 LF OF 121 ® 0.50% RD S CONNECT TO ROOF DRAIN LINE 14 (SEE STORM PROFILE #1) ,;, CB #21 //� o; STA:8+10.55, 0.00 II I i ' II ' 117. I 18 LF OF 12" 0 0.50% I� � / -STA: 0+60.67, 0.00' CB #17 IE OUT:163.69 (8" S) CATCH BASIN TYPE 1 ,' J STORM PROFILE #2 1+80.89 = o z ', FLOW CONTROL STRUCTURE STA:2+13.62, 29.03 RT 'W/ BI-DIRECTIONAL VANED GRATE `Q 19, 11 A -LINE 12+21.54 Q ' TYPE 50 AREA DRAIN o ' III �I R a :SEE DETAIL ON SHEET SD-04 CB #18 SEE COURT YARD o o RIM:, 77.86 " CONNECT TO ROOF DRAIN LINE - �' DS ; IE IN:154.74 (12 S) STA:12+14.55, 305.56 RT IE IN:173.75 (12 S) O IR �fI31�D MODULAR WETLAND MWS-6-8-V - STA:0+42.64, 0.00' RT - IE OUT.154.74 (12" N) RIM:167.04TYPE 50 AREA . - oc "-CCIE WITH CURB INLET I " IE OUT:163.69 (8" S) CONNECT TO ROOF DRAIN DRAIN LINE GRADING DETAIL #2 IE OUT:173.75 (12 N) , 1 12 OUTLET PIPE FOR VAULT ❑ SEE DETAIL ON SHEET SD-04 " I- CONNECT ROOF __ RIM:166.78 ' 0 1--_1311I IE OUT:154.83 (12 N) DRAIN INTO VAULT THIS SHEET '� '- RIM:162.78 " cn ' `Q' " IE OUT. 8 S ' I IE IN: 158.90 8 IE: 160.79 FFE:167+0 ( ) ; W , Qs, I IE OUT: 157.37 ps .�, '•r><; " j >>9 ,Iran , I 34 LF OF 12" ®0.50% RD i 42 LF OF 8 ®0.81 % " (SEE STORM PROFILE #1) ' I.1�1� 31;; 3; :II 1 ; STA:0+11.62, 36.65 RT 1+ �4 LF (� f ` I ; ' : ; ;Ih 12" PIPE INTO VAULT - o (SEE STORM PROFILE 4 I' T#� I', o+`I'�1+� wi-- _w�� ''� IE IN:157.20 (12" W) STA:10+04.81,00 M p' CB #3 �.,11 I;; ; 3' i STA:1+74.37, 0.13 RT TYPE 50 AREA DRAIN ` R'STOR �STA: 8+84.53, 0.00' 0 3 �' . ; ;I CONNECT STORM LINE TO RIM:178.66 0+ 4 10� 00 CB #2 CATCH BASIN TYPE 1 I` I STORMCAPTURE VAULT " , IE OUT:175.25 (8 E). " W BI-DIRECTIONAL VANED GRATE ;I• j �`. ,0 3� f' �RIM.162.51 /, /,-'' x 6� 44 LF OF 12 0 0.50% �STA:9+63.08, 0.00 / _ A pztg ;+ - I ; I I ; IE IN:160.79 (8" E) n CATCH BASIN TYPE 1 jRIM:178.22 " o I..' , -'' ' _ IE IN:174.38 12 W , � , SEE COURT YARD GRADING W/ BI-DIRECTIONAL VANED GRATE ( ) III RIM:178.66 �IE OUT'174.38 (12" N) :•�3I 3',, �I "' DETAIL #1 THIS SHEET IE IN:174.91 (8" W)- ; 11 1 I 10 LF OF 8 0 17.85% " - - IE IN:174.91 (12 SW) ' IE OUT.174.91 (12" E) o o , _ *� AIN II.tii113�D ~ - __- - ___ __ __ C' - 777 (�I I" T - STA:10+75.58 179.87' RT -� I • :#I II I I ,i`T.; AREA DRAIN - - - _ _ _ _ _ _ CB #15 CB #16 TYPE 50 / Pf�WATE CAST`=PLAE - - -_� _ f :•ll • I' ' DKNITION VAULT l� _ = RIM:166.62 � �`;' ; STA:10+71.47, 276.89 RT STA:10+71.01, 341.13 RT- - C6 #20 I(:1`� " -:�8 cP 'TYPE 50 AREA DRAIN :� TYPE 50 AREA DRAIN _ _ _ -_ __ STA:9+83.79, 38.93 LT E DETAILS dN �HE6T'SD-O6 , '� ,- .- IE OUT: (8 W) S, s, �'�` ----- -=- - - �= I �y- BOTTOM �F VAULT: 1�4.33; RIM: =�-=� RIM: 1 f �` T= CATCH BASIN TYPE 1 I..• I I `�". J TOF' OF,- VAULT:162.37 IE OUT.162.57 (8" N) IE OUT:162.53 (8" N) RIM:178.40 3 CONNECT ROOF DRAIN INTO VAULT " III • �'' 8" IE: 160.79 IE OUT:175.13 (12 NE) C�l_ % - :>I, r // ✓ / / ; j / STA: 0+98.03, 0.00' STA: 0+67.04, 0.00' RT " INSTALL 8 WYE CONNECTION INSTALL 8 WYE CONNECTION " IE IN:163.89 8" SE -- - - - :: RD IE IN:163.74 (8 S) ( ) STA:0+30.98, 0.00 - II 4" ROOF DR�lN�L1 IE IN:163.74 (8" E) RD IE IN:163.89 (8" E) INSTAL 8" 45' BEND RD RD ,� IE OUT:163.89 8" W " 4" ROOF D LINE o 1 ( ) IE IN:164.07 8 SE � � I IE OUT: (8 W) _ ( ) t 31 LF OF 8" @ 0.50% IE OUT.164.07 (8" W) I �'? - - - - SD 36 LF OF 8" 0.50% - - - }----SD I n (SEE STORM PROFILE #4) I - l� I N (SEE STORM PROFILE #4) , v7 SD -SD FOOTING DRAIN NOTE: THE CONTRACTOR SHALL INSTALL FOOTING DRAINS AS SHOWN ON THIS PLAN AND ALSO INSTALL FOOTING DRAINS ON THE INTERIOR FOOTINGS. SEE ARCHITECTURAL PLANS FOR INTERIOR FOOTING LOCATIONS. REFER TO R,,4036149 W,,403601 , S,,403601 FOR AS -BUILT INFORMATION CALL BEFORE YOU DIG THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE LOCATION AND PROTECTION OF ALL EXISTING UTILITIES. THE CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION BY CALLING THE UNDERGROUND LOCATE LINE AT (800) 424-5555 A MINIMUM OF 48 HOURS PRIOR TO ANY EXCAVATION. STA:1+00.41, 0.00' RT INSTALL 1-8"x4" WYE CONNECTION IE IN:163.73 (8" E) IE OUT:163.73 (8" W) If OUT:163.73 (4" N) RD SS D - JA R �O� OF WAS c�rS �P o u, Z OF RFGI STE��� `rSI O N A L 06/19/20191 NO. 7 LF OF 8" @ 0.50%-�_� (SEE STORM PROFILE #4) STA:0+62.04, 4.98' LT STA:0+23.98, 0.00' TYPE 50 AREA DRAIN TYPE 50 AREA DRAIN RIM:166.78 RIM:166.78 IE IN:164.03 (8" S) IE OUT:164.11 (8" NW) IE OUT:164.03 (8 NW) { DS - RDTDS 4" RO 0 COURTYARD GRADING DETAIL#1 KI TC 5 LF OF 8" ® 2.00% STA:0+98.06, 4.97' LT TYPE 50 AREA DRAIN RIM:166.78 IE OUT.163.84 (8" N) BUILDING PERMIT SUBMITTAL BUILDING PERMIT SUBMITTAL REVISION 7 LF OF 8" 0 2.00% " ROOF DRAIN LINE RD R.E.W. 05 01 19 R.D.J. R.E.W. 06/19/19 R.D.J. SURVEYED: DESIGNED: K. MEBAN DRAWN: S. ORDONEZ CHECKED: R. JARVIS APPROVED: R. JARVIS 1 "=30' I I � , ' DRAIN LINE R D I ONE INCH AT FULL SCALE IF NOT ONE INCH SCALE ACCORDINGLY VERTICAL• NAVD 1988 HORIZONTAL• NAD 1983/1991 DATU M CITY OF RENTON Planning/Building/Public Works Dept. LEGEND - - - - - - - - -XX- - - EXISTING CONTOURS (MAJOR/MINOR) -------------- XX-------- AA PROPOSED CONTOURS (MAJOR/MINOR) XX SD HDPE STORM PIPE, UNLESS OTHERWISE NOTED FD FOOTING DRAIN TYPE 1 CATCH BASIN PER CITY OF RENTON STD. DETAIL 200.00 SHOWN ON SHEET SD-05. TYPE 2 CATCH BASIN PER CITY OF RENTON STD. DETAIL 201.00 SHOWN ON SHEET SD-05. DRAIN6" ROOF RD NOTED, INSTNUNLESS ALLEDATMIN 0. %E SLOPE AND MIN. 1' OF COVER. SEE DETAILS ON SHEET SD-04 ■ AREA DRAIN DETAIL SHOWN ON SHEET SD-05 GENERAL STORMWATER NOTE: ALL ON -SITE STORMWATER SYSTEMS ARE PRIVATELY OWNED AND MAINTAINED. THIS INCLUDES CATCH BASINS, STORM PIPES, AND DETENTION SYSTEMS. uj z , J z� a o ' ' o `` o 5 LI I STA: 0+70. TYPE 50 IE IN: 1' IE OUT.1 I 40 LI / '(SEE ST S "/ W z II J I / z Q a� I / I' 7 LF Of (SEE STORM STA:0+23.19, 0.00' / TYPE 50 AREA DRAIN RIM:178.73 IE OUT.176.06 (8" NE) I SX -- O _ , y - I I / I 71 LF OF 8" 0 3.39% (SFF STORM PRDFII F IS) I-- '_- =-11 r - -STA:0+70.51, 0.00' INSTALL 8" WYE CONNECTION IE IN:175.82 (8" S) -IE IN:175.82 (8" W) CIE OUT.175.82 (8" E) 1 / ir / \-STA:0+30.17, 0.00' INSTALL 8" 45' BEN IE IN:176.03 (8" SW) IE OUT-176.03 (8" N I I .I I I D I I I I R-403615 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING A0114 SURFACE WATER UTILITY + jchavez 07/16/2019 ' jfarah 07/12/2019 WEATHERLY INN RENTON 4500 TALBOT RD SFIEUM RENTON, WA 98055 PAGE: AGE. OK: P DRAWING NO: STORM DRAINAGE PLAN SD-01 SHOT. 15 OF:51