Loading...
HomeMy WebLinkAboutR-403619ID: DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 7" KNOCKOUTS 4 SIDES 16" 6" RISER 12" RISER 15# 30# 12x12 AREA DRAIN NTS 0 X z s CU OVERFLOW EL. 160.83 18" HDPE RISER Ac 1.2" DIAM. ORIFICE ELEV. 155.47 PIPE SUPPORTS (2 MIN.): 3" x .090" GAGE SUPPORT BRACKET BOLTED OR EMBEDDED 2" IN WALL AT MAX. 3' SPACING, MIN. ONE <:' SUPPORT. 1'-0" 1.9" DIAM. ORIFICE ELEV. 154 0 12" UTLET PIPE PRIVATE) REMOVABLE WATERTIGHT COUPLING OR FLANGE - T MIN. CLEARANCE TO ANY PORTION OF FLOW RESTRICTOR TEE INCLUDING ELBOWS 2" MIN. ELBOW RESTRICTOR, SEE DETAIL AND NOTE 10 - 6" MIN. Z MIN, 6" MAX. PLATE WELDED TO ELBOW WITH ORIFICE AS SPECIFIED, SEE NOTE 3 ELBOW RESTRICTOR DETAIL ELEVATION PER PLANS 12" MIN. UNDER PAVEMENT -I ADDITIONAL LADDER RUNGS (IN SETS) TO ALLOW ACCESS TO TANKS OR VAULTS WHEN CATCH IS FILLED WITH WATER II iJ / {/ ANGLE AS / \- NECESSARY, / SEE NOTE 7 PLAN VIEW FRAME & SOLID COVER MARKED "DRAIN" WITH LOCKING BOLTS PER STD. PLAN 204.50 1 16" MAX. VERTICAL BAR GRATE FOR SECONDARY INLET 6"MIN. DESIGN WATER ELBOW RESTRICTOR, SURFACE SEE DETAIL AND NOTE 10 HANDHOLDS, STEPS, OR LADDER PIPE SUPPORTS, SEE NOTE 6 r 12" (TYP.) 1.5 x D }1} SEE NOTE 9 (TYP.) MIN. 2' MIN. T ISOMETRIC i OUTLET PIPE, SEE INLET PIPE NOTES 1 & 5 2' INVERT AND MIN. SHEAR GATE WITH CONTROL ROD FOR ELEVATION PER PLANS CLEANOUT/ORAIN (ROD BENT AS REQUIRED FOR VERTICAL ALIGNMENT WITH COVER) 12" SECTION OF PIPE ATTACHED BY PER STD. PLAN 237.30 GASKETED BAND TO ALLOW REMOVAL 2' 12" MIN. WELDED RESTRICTOR PLATE WITH ORIFICE DIA AS SPECIFIED, SEE NOTE 10 NOTES: SECTION A 1. USE A MIMIMUM OF A 54" DIAMETER TYPE 2 CATCH BASIN. 2. OUTLET CAPACITY: 100-YEAR DEVELOPED PEAK FLOW. 3. METAL PARTS PREFERRED TO BE STAINLESS STEEL, ALUMINIZED STEEL, OR ALUMINUM. ALL OTHER STEEL PARTS MUST BE GALVANIZED WITH TREATMENTS 1, 2, OR 5. 4. FRAME AND LADDER OR STEPS OFFSET SO: A. CLEANOUT GATE IS VISIBLE FROM TOP. B. CLIMB -DOWN SPACE IS CLEAR OF RISER AND CLEANOUT GATE. C. FRAME IS CLEAR OF CURB. 5. IF METAL OUTLET PIPE CONNECTS TO CEMENT CONCRETE PIPE: OUTLET PIPE TO HAVE SMOOTH O.D. EQUAL TO CONCRETE PIPE I.D. LESS 1/4". 6. PROVIDE AT LEAST ONE 3" X .090 GAGE SUPPORT BRACKET ANCHORED TO CONCRETE WALL. (MAXIMUM T-O" VERTICAL SPACING). 7. LOCATE ELBOW RESTRICTOR(S) AS NECESSARY TO PROVIDE MINIMUM CLEARANCE AS SHOWN. 8. LOCATE ADDITIONAL LADDER RUNGS IN STRUCTURES USED AS ACCESS TO TANKS AND VAULTS TO ALLOW ACCESS WHEN CATCH BASIN IS FILLED WITH WATER. 9. WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 10. IF TEE SECTION IS USED ONLY FOR SPILL CONTROL, THEN ELBOW RESTRICTORS AND RESTRICTOR PLATES WITH ORIFICES ARE NOT REQUIRED. UNLESS OTHERWISE NOTED, DRAWING IS NOT TO SCALE (NTS) STD. PLAN - 237.00 PUBLIC WORKS FLOW CONTROL STRUCTURE - APPROVE 13 DEPARTMENT RESTRICTOR TEE GAZ 9/28/2018 I u. w..l�nem",nao, DATE ISOLID gCOVER MARKED "DRAIN" 2 OCKING RING AND COVER. SEE NOTE 10. CD CD 4, DETENTION VAULT 'Mu. W.S. 160.83 FRAME & LADDER OR STEPS OFFSET. SEE NOTE 8. A - H R GATE 2 IN NN A P IVATE INVERT ELEVATION �' 4 INVERT ELEVATION 154.78 154.78 ARESTRICTOR ORIFICE 1.2" DIAM. o z ELEV. 152.78 PLATE BOLTED TO FLANGE, OR DRILLED CAP. ' NOTES: Ln CD 1. PIPE SIZES, INVERT ELEVATIONS, ORIFICE SIZES, OVERFLOW ELEVATIONS AND SLOPES PER PLANS. O 2. OUTLET CAPACITY: NOT LESS THA THE 100-YEAR DEVELOPED PEAK FLOW. 2 CD 00 3. EXCEPT AS SHOWN OR NOTED, UNITS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE REQUIREMENTS FOR CATCH BASIN TYPE 2, 54" MIN. DIAM. In In Q 4. PIPE SUPPORTS SHALL BE ANCHORED AT 3' MAX. SPACING BY 5/8" DIAM. STAINLESS STEEL EXPANSION BOLTS OR EMBEDDED 2" IN WALL. Ld m 5. THE RESTRICTOR PLATE SHALL BE FABRICATED FROM HDPE PER THESE ENGINEERING STANDARDS. z Q 6. OUTLET SHALL BE CONNECTED TO CULVERT OR SEWER PIPE WITH SUITABLE COUPLER OR GROUTED INTO THE BELL OF CONCRETE PIPE. 2 z 7. THE VERTICAL RISER STEM OF THE RESTRICTOR SHALL HAVE A 12" DIAMTER. V) 8. LADDERS AND HAND -HOLDS SHALL BE PROVIDED AT ALL ACCESS OPENINGS AND AS NEEDED TO MEET OSHA CONFINED SPACE REQUIREMENTS. FRAME AND D_ LADDER OR STEPS OFFSET SO THAT: 0 cn A. SHEAR GATE IS VISIBLE FROM TOP. o B. CLIMB DOWN SPACE IS CLEAR OF RISER AND SHEAR GATE. z C. FRAME IS CLEAR OF CURB. 0: 9. IF METAL OUTLET PIPE CONNECTS TO CEMENT CONCRETE PIPE: OUTLET PIPE TO HAVE SMOOTH O.D. EQUAL TO CONCRETE PIPE I.D. LESS 1 /4". Y 10. SHEAR GATE HANDLE SHALL BE ATTACHED TO LADDER/ STEP LOCATED WITHIN 24" ACCESS SECTION. L W FLOW CONTROL STRUCTURE Sso °WAg o R� js E� CALL BEFORE YOU DIG NTS � THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE LOCATION ct�DO 2 `" rn AND PROTECTION OF ALL EXISTING UTILITIES. THE CONTRACTOR SHALL ` `� 2 VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION BY CALLING o� 41668 �FcISTER�° THE UNDERGROUND LOCATE LINE AT (800) 424-5555 A MINIMUM OF 10 48 HOURS PRIOR TO ANY EXCAVATION. AL 0611912019 N0. �z :45 AN 4', 6', 12', OR 24" ONE #3 BAR HOOP FOR 6" HEIGHT INCREMENT (SPACED EQUALLY), SEE NOTE 1 RECTANGULAR ADJUSTMENT SECTION 6 O � `SF 2• SE�� A FNOTF I 03 BAR EACH CORNER I / I I Z I I �y #3 BAR EACH SIDE #3 BAR EACH WAY PRECAST BASE SECTION #3 BAR HOOP PIPE ALLOWANCES MAXIMUM PIPE MATERIAL INSIDE DIAMETER REINFORCED OR PLAIN 12" CONCRETE ALL METAL PIPE 15" CPSSP" 12" STD. SPEC. 9-, 05.20 SOLID WALL PVC, STD. SPEC. 9-05.12(1) 15" PROFILE WALL PVC, STD. SPEC. 9-05.12(2) 15" ' CORRUGATED POLYETHYLENE STORM SEWER PIPE NOTES: 1. AS ACCEPTABLE ALTERNATIVES TO THE REBAR SHOWN ' IN THE PRECAST BASE SECTION, FIBERS (PLACED IN ACCORDANCE WITH STANDARD SPECIFICATION 9-05.50(9)), OR WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT SHALL BE USED WITH THE MINIMUM REQUIRED REBAR SHOWN IN THE ALTERNATIVE PRECAST BASE SECTION. WIRE MESH SHALL NOT BE PLACED IN THE KNOCKOUTS. AS AN ACCEPTABLE ALTERNATIVE TO THE REBAR SHOWN IN THE RECTANGULAR ADJUSTMENT SECTION, WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT MAY BE USED. 2. THE KNOCKOUT DIAMETER SHALL NOT BE GREATER THAN 20". KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 3. THE MAXIMUM DEPTH FROM THE FINISHED GRADE TO THE LOWEST PIPE INVERT SHALL BE 5 FEET. 4. THE FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN. 5. THE PRECAST BASE SECTION MAY HAVE A ROUNDED FLOOR, AND THE WALLS MAY BE SLOPED AT A RATE OF 1 H:24V OR STEEPER. 6. THE OPENING SHALL BE MEASURED AT THE TOP OF THE PRECAST BASE SECTION. 7. ALL PICKUP HOLES SHALL BE GROUTED FULL AFTER THE INLET HAS BEEN PLACED. USE GROUT TYPE 2 FOR #3 BAR EACH NON -SHRINK APPLICATIONS IN ACCORDANCE WITH CORNER 18" MIN. STANDARD SPECIFICATION 9-20.3(2). 8. ALL GRADE RINGS AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. THEN APPLY MORTAR TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, RISERS, AND FRAMES. 9. MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 10. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. 11. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND SEE NOTE 1 REMAIN VISIBLE UPON COMPLETION. ALTERNATIVE PRECAST BASE SECTION UNLESS OTHERWISE NOTED, DRAWING Is Norio SCALE (NTS) STD. PLAN - 200.00 PUBLIC WORKS A1 F& I DEPARTMENT CATCH BASIN TYPE 1 GAZ 9/28/2018 I DATE DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 F FLOW ❑o 0 o 0 'J` a OUTFACE TO STREAM DUMP NO POLLUTANTS I BOLT -DOWN SLOT, I SEE DETAIL AND NOTE 1 � I43/411"HI I � I 5/8" I I BOLT -DOWN SLOT DETAIL SEE NOTE 1 TOP /\ 318" RECESSED LETTERING ISOMETRIC 24- 7 OR 8 EQUAL SPACES 5" 1 DIRECTION FLOW I 3' 1 5/8" MAX. SECTION A SECTION B NOTES: 1. BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, GRATES, AND COVERS, UNLESS OTHERWISE SPECIFIED. PROVIDE TWO HOLES IN THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS. THE FRAME SHALL ACCEPT THE SIT-11 NC x 2" ALLEN HEAD CAP SCREW BY BEING TAPPED, OR OTHER APPROVED MECHANISM. LOCATION OF BOLT -DOWN HOLES VARIES BY MANUFACTURER. 2. REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL REQUIREMENTS. 3. FOR FRAME DETAILS, SEE STANDARD PLAN 204.00. UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (NTS) Aparu STD. PLAN - 204.20 _cam PUBLIC WORKS �I� DEPARTMENT RECTANGULAR VANED GRATE PRO GAZ 9/28/2018 I w",6-" .1., DATE BUILDING PERMIT SUBMITTAL BUILDING PERMIT SUBMITTAL REVISION :45 Al CATCH BASIN FRAME AND VANED GRATE PER STD. PLAN 204.00 RECTANGULAR OR CIRCULAR ADJUSTMENT SECTION (TWO SECTIONS MAX.) MORTAR, (TYP.), SEE NOTE 5 4" MIN. 28" MAX, 16" MAX. FLAT SLAB TOP 48-, 54', 60", 72', 84", 96', 120' OR 144" SEE NOTE 6, TYP. 15' MAX. FOR MAINTENANCE STEPS OR LADDER 12 �o L T 1" MIN. "O" RING 24' 2.5" MAX. REINFORCING STEEL, (TYP.) MIN. 12" MAX' 12" GRAVEL BACKFILL FOR PIPE ZONE ' 12" BEDDING PER WSDOT STD. SPECIFICATION SECTION 9-03.12(3) 6 6„ SEPARATE BASE INTEGRAL BASE PRECAST PRECAST WITH RISER NOTES: 1. NO STEPS ARE REQUIRED WHEN HEIGHT IS 4' OR LESS. 2. THE BOTTOM OF THE PRECAST CATCH BASIN MAY BE SLOPED TO FACILITATE CLEANING. 3. THE RECTANGULAR FRAME AND GRATE MUST BE INSTALLED WITH THE FLANGE DOWN. THE FRAME MAY BE CAST INTO THE ADJUSTMENT SECTION. 4. KNOCKOUTS SHALL HAVE A WALL THICKNESS OF 2" MINIMUM TO 2.5" MAXIMUM. PROVIDE A 1.5" MINIMUM GAP BETWEEN THE KNOCKOUT WALL AND THE OUTSIDE OF THE PIPE. AFTER THE PIPE IS INSTALLED, FILL THE GAP WITH JOINT MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 5. ALL GRADE RINGS, RISERS, AND CASTINGS SHALL BE SET IN MORTAR IN ACCORDANCE WITH STANDARD SPECIFICATION 9-04.3. 6. WHEN CONNECTING TO A NEW PIPE, USE A FLEXIBLE CONNECTOR (KOR-N-SEAL BOOT WITH CORRUGATED PIPE ADAPTER OR APPROVED EQUAL). WHEN CONNECTING TO AN EXISTING PIPE, USE A FABRICATED SAND COLLAR OF THE SAME MATERIAL AS THE CONNECTING PIPE. 7. MORTAR SHALL BE MIXED AND APPLIED PER MANUFACTURER'S DIRECTIONS. 8. FRAME SHALL BE ADJUSTED TO PAVEMENT GRADE BY TAPPING UNTIL FRAME IS FLUSH WITH PAVEMENT AS DETERMINED WITH A STRAIGHT EDGE OF SUFFICIENT LENGTH. 9. ALL MORTAR JOINTS SHALL BE TRIMMED FLUSH AND REMAIN VISIBLE UPON COMPLETION. PUBLIC WORKS DEPARTMENT CATCH BASIN DIMENSIONS CATCH BASIN DIAMETER MIN. WALL THICKNESS MIN. BASE THICKNESS MAXIMUM KNOCKOUT SIZE MINIMUM DISTANCE BETWEEN KNOCKOUTS 48" 4" 6" 36" 8" 54" 4.5" 8" 42" 8" 60" 5" 8" 48" 8" 72" 6" 8" 60" 12" 84" 8' 1 12' 1 72" 1 12" 96" 8" 12" 84" 12" 120" 10" 12" 96" 12" 144" 12" 1 12" 1 108" 1 12" PIPE ALLOWANCES CATCH BASIN PIPE MATERIAL WITH MAXIMUM INSIDE DIAMETER DIAMETER CONCRETE ALL METAL CPSSP, SOLID WALL pVC � PROFILE WALL PVC, 48" 24" 30" 24" 30" 30" 54" 30" 36" 30" 36" 36" 60" 36" 42" 36" 42" 42" 72" 42" 54" 42" 48" 48" 84" 54" 48" 48" 96" 60" 72" 60" 48" 48" 120" 1 66" 84" 60" 48" 48" 144" 78" 96" 60" 48" 48" '.CORRUGATED POLYETHYLENE STORM SEWER PIPE (STD. SPEC. 9-05.20) STD. SPEC. 9-05.12(1) 3 STD. SPEC. 9-05.12(2) CATCH BASIN TYPE 2 DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 :45 AN UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (NTS) STD. PLAN - 201.00 PR D GAZ 9/28/2018 I DATE r---------- I I I I I I 1/2" I BOLT -DOWN SLOT, I I I SEE DETAIL AND i �..{ 3/4" NOTE 1 IIIF' 1 1/4" I I � I I TI I I 1 BOLT -DOWN SLOT DETAIL SEE NOTE 1 3/8' RECESSED LETTERING ISOMETRIC 24" 1 � 4 EQUAL SPACES 4 EQUAL SPACES �I 1 5/8" MAX. J SECTION A NOTES: 1. BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, GRATES, AND COVERS, UNLESS OTHERWISE SPECIFIED. PROVIDE TWO HOLES IN THE FRAME THAT ARE VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS. THE FRAME SHALL ACCEPT THE 5/8"-11 NC x 2" ALLEN HEAD CAP SCREW BY BEING TAPPED, OR OTHER APPROVED MECHANISM. LOCATION OF BOLT -DOWN HOLES VARIES BY MANUFACTURER. 2. REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL REQUIREMENTS. 3. USE ONLY IN SAGS ON VERTICAL CURVES. 4, FOR FRAME DETAILS, SEE STANDARD PLAN 204.00, UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (NTS) STD. PLAN - 204.30 PUBLIC WORKS RECTANGULAR BI-DIRECTIONAL PR D. ..�• "` DEPARTMENT VANED GRATE GAZ 9/28/2018 I DATE REFER To R*4403614, W*4403601 , S,,403601 FOR AS -BUILT INFORMATION R.E.W. 05 01 19 1 R.D.J. SURVEYED: SCALE VERTICAL: NAVD 19M R.E.W. 06 19 19 R.D"J. 1 "=30' HORIZONTAL NAD 1863/1891 DESIGNED: K. MELVIN DRAWN: S. ORDONEZ ONE INCH DATUM CHECKED: R. JARVIS AT FULL SCALE IF NOT ONE INCH BY DATE APPR APPROVED: SCALE ACCORDINGLY R. JARVIS :45 AI :45 AN 24" - I ( F -1 1/2" L BOLT -DOWN SLOT, 3/4^ SEE DETAIL AND 2 1/2" DIA. HOLE NOTE 1 1 11/4" 20" A 0o I 5/8" I 0�4�4Q I QOQOQ4�0 BOLT -DOWN SLOT DETAIL m TOP ISOMETRIC r4 3/4" 1 1/2' 1 5/888 R39", SEE NOTE 2 SEE NOTE 1 3" R26", SEE NOTE 2 1 112" 5 NOTES: rF; 1/2"::l r 314" 1. BOLT -DOWN CAPABILITY IS REQUIRED ON ALL FRAMES, GRATES, AND COVERS, UNLESS OTHERWISE SPECIFIED. 1 5/g• �11 PROVIDE TWO HOLES IN THE FRAME THAT ARE I VERTICALLY ALIGNED WITH THE GRATE OR COVER SLOTS. THE FRAME SHALL ACCEPT THE 5/8"-11 NC x 2" ALLEN 4' HEAD CAP SCREW BY BEING TAPPED, OR OTHER .4"DIA. HOLE APP ROVED MECHANISM. LOCATION OF BOLT -DOWN HOLES VARIES BY MANUFACTURER. 1/2" DIA. HANDLE 1 1/2" 2. ALTERNATIVE REINFORCING DESIGNS ARE ACCEPTABLE IN LIEU OF THE RIB DESIGN. SECTION C 3. REFER TO STANDARD SPECIFICATION 9-05.15(2) FOR ADDITIONAL REQUIREMENTS. 4. FOR FRAME DETAILS, SEE CITY OF RENTON STANDARD PLAN 204.00. UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (NTS) STD. PLAN - 204.10 PUBLIC WORKS ° U RECTANGULAR SOLID METAL COVER GAZ 9/28/2018 DEPARTMENT DATE DocuSign Envelope ID: 6EECF5B6-602A-4E4A-B436-A317AA638878 #6 BARS @ 7" SPACING T 12" (TYP.) 1 20"x24", 24" DIA., 48" DIA., OR 54" 48" DIA. HOLE MAX. I� 6 I L� z" (TYP.) 12" 14 9" "- 12 1" MIN. 2 112" MAX. 84" or 96" FLAT SLAB TOP PREFABRICATED LADDER 12" IN. 11 6" =It #5 BARS @ 6" SPACFF- ING STEP 91/2" MAX. 20"x24", 24- DIA., 48" DIA., OR 54" DIA. HOLE 24" 8„ U II 1" MIN. 2 1/2" MAX. .� MIN. 72" FLAT SLAB TOP 18" MIN. 24" 42" MAX. #4 BARS @ 6" SPACING IZ- MIN. 20"x24" OR 24"DIA. HOLE TYPICAL ORIENTATION 48" MIN. ECCENTRIC CONE SECTION 2" (TYP) L FOR ACCESS AND STEPS 8„ 1" MIN 21/2" MAX. 48", 54", or 60" FLAT SLAB TOP "�' 1A 7�• �" 34" 5 s• �1-.2", 4'. 6', 12", OR 24" ONE #3 BAR HOOP FOR 6" III Y HEIGHT INCREMENT (SPACED EQUALLY), SEE NOTE 1 I 1 II, i", 2', 4', 6-. `$- 12", OR 24" ONE #3 BAR HOOP FOR 6" HEIGHT INCREMENT (SPACED EQUALLY), CIRCULAR ADJUSTMENT SECTION SEE NOTE 1 RECTANGULAR ADJUSTMENT SECTION NOTES: 1. AS AN ACCEPTABLE ALTERNATIVE TO REBAR, WIRE MESH HAVING A MINIMUM AREA OF 0.12 SQUARE INCHES PER FOOT MAY BE USED FOR ADJUSTMENT SECTIONS. UNLESS OTHERWISE NOTED, DRAWING IS NOTTO SCALE (NTS) OS STD. PLAN - 204.60 PUBLIC WORKS MISCELLANEOUS DETAILS FOR A PRgvoAZ _.c� "` DEPARTMENT DRAINAGE STRUCTURES 9/28/2018bk­I waVAd DATE R-403619 IN COMPLIANCE WITH CITY OF RENTON STANDARDS DEVELOPMENT ENGINEERING SURFACE WATER UTILITY jchavez 07/16/2019 jfarah 07/12/2019 :45 AN 45 AN %R CITY OF WEATHERLY INN RENTON FlELDBOOK: RENTON 4500 TALBOT RD S PAGE. • RENTON, WA 98055 DRAWING NO: Planning/Building/Public Works Dept. STORM DRAINAGE DETAILS SD-05 SHEET: OR 19 51