Loading...
HomeMy WebLinkAboutR-403640M O I I 0 W M O N 1• (D� aD o �� �00 �M 3 N U � Z o W N a- CO a- � o J E w L N 00 N 00 N � � 0 N W 0 0 N � a �Z WATER METER/ POINT OF CONNECTION (P.O.C.) — SEE PLAN FOR LOCATIONS) BALL VALVE DOUBLE CHECK VALVE ASSEMBLY (SEE DRAWING FOR LOCATION AND SIZE) QUICK COUPLER MANUAL DRAIN VALVE 1 POINT OF CONNECTION (POC) DETAIL N.T.S. RAINBIRD #63100 VALVE MARKER 2" PVC SLEEVE MAIN LINE REDUCING TEE 3/4" CLOSE NIPPLE 3/4" X 3" PROTECTIVE PVC NIPPLE GRAVEL SUMP (2 CU. FT.) 12" MIN. 5 MANUAL DRAIN VALVE DETAIL NTS FINISF SPRINKI 1-SCH. 40 & STREE PRE-ASSEMBL JOINT W/ SCH. 9 POP-UP SPRINKLER HEAD N.T.S. NISH GRADE P-CO-REN-21 BRASS ANGLE VALVE WITH UNION. INSTALL AT ALL MAINLINE LOW POINTS TO FACILITATE COMPLETE MAINLINE DRAINAGE. Z_ 73 04 10" DIAMETER ROUND VALVE SET BOX 2" ABOVE GRADE AT SHRUBS. BOX, SEE SPECIFICATIONS. SET BOX FLUSH TO GRADE AT LAWN. — FINISH GRADE. n w o ��I ,�� m FOUR COMMON BRICK SUPPORTS. 10" DIA. PVC PIPE EXTENSION, LENGTH AS REQUIRED. ISOLATION VALVE AS '— PVC MAIN LINE. SPECIFIED.L SLIP/THREAD COUPLING. 6" SCHEDULE 80 THREADED NIPPLE. BRASS ISOLATION VALVE 1 1/2" = 1'-0" SCH. 80 RISER 20"X14" JUMBO PL VALVE BOX. PVC TRUE UNION BAL1--, VALVE. 2" ABOVE GRADE AT SHRUBS. SET BOX FLUSH///mm�m AT TURF. E� FINISH GRADE AT LIP OF BOX IN TURF AND PAVED AREAS (1" BELOW LIP IN ALL OTHER AREAS) VALVE BOX: REFER TO IRRIGATION SHEET NOTES OR SPECIFICATIONS VALVE BOX COVER — BRASS UNION BRASS NIPPLES " MIN. CLE A RANCE 6E -7 BACKFLOW PREVENTOR PVC MAINLINE PEA GRAVEL (INSTALL MIN. 2 CU. FT. BELOW BACKFLOW PREVENTOR) 3 DOUBLE CHECK VALVE (DCVA) P-CO-REN-22 NTS CONTROLLER WIRE WITH 30 INCH LINEAR LENGTH OF COIL, WITH PLASTIC I.D. TAG AND WATERPROOF CONNECTORS. RCV AS SPECIFIED. BASKET FILTER AS SPECIFIED. PRESSURE REGULATOR AS SPECIFIED. PVC UNION W/ SHORT NIPPLES. ITIIII,� III o m OUTLET PIPE SAME SIZE AS VALVE, 24"ibFFhP LENGTH TO FIRST FITTING. PROVIDE FOUR BRICKS TO 45° DOWN AS REQ. TO SUPPORT VALVE BOX. LATERAL PIPE DEPTH. SxT TEE W/ 2" NIPPLE AT MAINLINE. 6 DRIP VALVE W/BASKET FILTER P-CO-REN-24 1 1/2" = 1'-0" P-CO-REN-35 18-24" COILED WIRE P-CO-REN-27 WATERPROOF CONNECTIONS (2) NODE-X00 NODE CONTROLLER 1 1/2" = V-0" P-CO-REN-30 TECHLINE COMBINATION TEE (MODEL TL075FTEE) DRIPLINE TUBINf Y4" MIN. TRIPLE SWIN JOIN NOTE - EACH CONNECTIOP CAPABLE OF MAX 10 GPM FINISH GRADE O v •d TWO STAINLESS STEEL CLAMPS. 1/2" X 36" GALV — STEEL PIPE. THREE PVC SCH 80 ELLS. 10" DIAMETER VALVE BOX. HEAD BRAND "QVC" ON LID C/) WITH 2" HIGH CHARACTERS. E Q Q Ld z Q gm z = = z FINISHED GRADE. N QUICK COUPLING VALVE AS SPECIFIED. GALV. NIPPLE, LENGTH AS REQ. 6" DEEP LAYER OF 3/4" CRUSHED ROCK. 3" PVC SCHEDULE 80 NIPPLE. 12" PVC SCHEDULE 80 NIPPLE. 4 QUICCOUPLING VALVE IN BOX P-CO-REN-18 1 1/2" = 1'-0" r NOTE: P-CO-REN-33 1. RECOMMENDED MINIMUM FILTRATION: 120 MESH 2. PRESSURE AT FLUSH VALVE SHALL BE MIN 21.8 PSI 3. HIGH CHECK VALVE (MAX 8.5' OF WATER (ELEVATION CHANGE)) 4. REFER TO MAXIMUM LENGTH OF A SINGLE LATERAL CHART REMOTE CONTROL VALVE WITH DISC FILTER AND PRV PVC OR POLY SUPPLY HEADER Techline® HCVXR DRIPLINE Techline® START CONNECTION SEE SPECIFICATIONS FOR ROW SPACING ISLAND PERIMETER PERIMETER LATERALS 2" TO 4" FROM EDGE Lv vJ MANUAL FLUSH VALVE PLUMBED MF TO Techline® HCVXR (TYP) 7 TECHLINE START CONNECTION (SWING JOINT RISER) 8 HCVXR LITE ISLAND LAYOUT N.T.S. P-CO-REN-28 NTS REFER To R,,403614, W,-1403601 , S*4403601 FOR AS -BUILT INFORMATION B . G v VCR BUILDING PERMIT SUBMITTAL #2 A VOS 05 01 19 JBG suRVEym: z z BUILDING PERMIT SUBMITTAL #3 A VOS 06 19 19 JBG DESIGNED: A. VOS U DRAWN: �Q> A. VOS s ioCHECKED J. GLANDER FxP.o2 P E A APPROVED: N0. REVISION BY DATE APPR 09/14/2018 J. GLANDER ONE INCH AT FULL SCN E IF NOT ONE INCH SCALE ACCORDINGLY VMCAL: NAVE) 19M HORIZONTAL: NAD 1953/1991 DATUM AO %R CITY OF RENTON Planning/Building/Public Works Dept. W-40361 0 R-403640 IN COMPLIANCE WITH CITY OF RENTON STANDARDS CURRENT PLANNING Matt Herrera 08/05/2019 ' WEATHERLY INN RENTON 4500 TALBOT RD S FlELDBOOK: PAGE: RENTON, WA 98055 DRAWING No: IRRIGATION DETAILS IR-03 SHEET. OR 50 51