SET CONTROLLER 60" ABOVE
FINISHED GRADE UNLESS
OTHERWISE NOTED.
CONTROLLER AS SPECIF
SECURELY BOLT CONTR
TO WALL. INSTALL BAC
BATTERIES AS REQUIRE[
GROUND AS PER MFG.
SPECIFICATIONS.
1/2" DIAMETER RIGID
STEEL CONDUIT FOR
110 VAC ELECTRICAL
SOURCE. INSTALL AS
PER LOCAL ELECTRICAL
CODES.
FINISHED GRADE.
00 LONG SWEEF
1 1/2" DIAMETER RIGID
STEEL CONDUIT FOR
RCV WIRES.
PVC SCH. 40
bLLOW GRADE.
1 WALL MOUNT CONTROLLER
1" = 1'-0" P-CO-REN-31
VALVE BOX & COVER;
FINISH GRADE AT LIP OF
REFER TO IRRIGATION
BOX IN TURF AND PAVED
SHEET NOTES AND/OR
AREAS; 1" BELOW LIP IN
DETAILS, PROVIDE
ALL OTHER AREAS
VALVE BOX EXTENSIONS
AS REQUIRED.
SCH. 80 PVC UNION ELECTRIC CONTROL VALVE
LATERAL PIPE TO SCH. 80 NIPPLE
SPRINKLERS
SCH. 40 PVC & FITTING
SUPPORT VALVE
BOX WITH 4
BRICKS, TYP.
E�
PROVIDE A MIN. 3"
MINIMUM 6" DEPTH CLEARANCE
OF PEA GRAVEL
ffm TI IT SCH. 40 PVC FITTING
LOW VOLTAGE WIRES
PRESSURE MAINLINE
NOTE: ALL WIRES TO BE INSTALLED AS PER LOCAL CODES. NO "IN -LINE" WIRE SPLICES
ALLOWED. TAPE AND BUNDLE WIRES EVERY 20 FEET. PROVIDE EXPANSION COILS AT EACH
VALVE - WRAPPING WIRE AROUND 1/2" PIPE 15 TIMES. ALL THREADED CONNECTIONS SHALL BE
MADE WITH TEFLON TAPE.
3 ELECTRONIC CONTROL VALVE
P-CO-REN-32
09/14/2018
10
SINGLE OUTLET EMITTER:
IRRIGATION SPECIFICATIONS
RAINBIRD XERI-BUG
O2
1/4" VINYL DISTRIBUTION TUBING
1.
THIS PLAN IS DIAGRAMMATIC; ALL PIPING, VALVES, ETC. SHALL BE INSTALLED IN SHRUB BEDS WHERE POSSIBLE AND
SHALL FOLLOW THE PLAN AS CLOSE AS IS PRACTICAL.
30
1/4" TUBING STAKE
O4
MICRO -SPRAY: RAINBIRD
2.
LOCATE ALL MAINLINES WITHIN THE PROJECT LIMITS.
XERI-SPRAY
3.
PIPE SIZES ARE CONSTANT BETWEEN PIPE SIZE CALL -OUTS. ALL LATERIAL PIPES SHALL BE INSTALLED AT 12" DEPTH
O5
SUBTERRANEAN EMITTER BOX
AND 24" DEPTH UNDER PAVED AREAS. MAIINLINE PIPE SHALL BE INSTALLED AT 18" BELOW GRADE AND 24" BELOW
PAVED AREAS.
O6
MULTI -OUTLET EMISSION DEVICE
O7
POLYFLEX RISER
4.
REFER TO DETAILS FOR ADDITIONAL INFORMATION.
5.
ALL PIPING AND WIRING UNDER PAVED AREAS SHALL BE HOUSED IN CLASS 200 PVC SLEEVES INSTALLED AT A 24"
O8
FINISH GRADE ADJACENT PAVING
DEPTH. SIZE SLEEVES AS NEEDED TO ACCOMMODATE PIPE AND WIRES, UNLESS OTHERWISE SPECIFIED ON DRAWING.
OR BARK MULCH FLUSH WITH TOP
OF BOX
6.
CONTRACTOR SHALL MAKE FIELD ADJUSTMENTS AS NEEDED TO OBTAIN FULL COVERAGE. LANDSCAPE ARCHITECT
RESERVES THE RIGHT TO MAKE NOZZLE CHANGES AS NEEDED AT NO ADDITIONAL COST. ADJUST HEAD POSITIONS
O9
SUBGRADE
AND ADD OR DELETE HEADS AS NEEDED DEPENDING ON ACTUAL FIELD CONDITIONS.
10
FLEX RISER STAKE
7.
ALL MANUAL, GATE AND ELECTRICAL VALVES AND OTHER UNDERGROUND EQUIPMENT SHALL BE HOUSED IN NELSON,
11
PVC SCH 80 CLOSE NIPPLE
AMETEK OR EQUAL RECTANGULAR VALVE BOXES.
12
3-INCH MIN. DEPTH OF 3/4"
8.
NO IN -LINE WIRE SPLICES ALLOWED. SUPPLY VALVE BOXES AT ALL ELECTRICAL JUNCTIONS. TAPE AND BUNDLE
WASHED GRAVEL
WIRES EVERY 25 LINEAR FEET.
13
PVC SCH 40 TEE OR ELL
9.
CONTRACTOR IS RESPONSIBLE FOR COMPLETE SYSTEM DRAINAGE. INSTALL KING BROS. 1/2" AUTOMATIC DRAIN
VALVES AT LATERAL LINE LOW POINT(S). INSTALL MANUAL DRAINS AT ALL MAINLINE LOW POINT(S) AND WHERE
14
PVC LATERAL PIPE, SIZE PER PLAN
INDICATED ON PLAN. CONTRACTOR SHALL PROVIDE ADJUSTABLE CHECK VALVES ON ANY IRRIGATION HEAD THAT
EXPERIENCES LOW HEAD DRAINAGE.
2 M
LTI-OUTLET EMISSION DEVICE
P-CO-REN-45
REFER To Ro*4036149
W,,4036019 S*4403601 FOR
AS -BUILT INFORMATION
BUILDING PERMIT SUBMITTAL #2 A VOS 05 01 19 JBG suRVEYED:
2 BUILDING PERMIT SUBMITTAL #3 A VOS 06 19 19 JBG DESIGNED: �+
A. VOS
DRAWN:
A. VOS
CHECKED:
J. GLANDER
NO. REVISION BY DATE APPR APPROVED:
J. GLANDER
ONE INCH
AT FULL SCALE
IF NOT ONE INCH
SCALE ACCORDINGLY
10. ALL THREADED PIPE CONNECTIONS SHALL BE MADE USING TEFLON TAPE WRAPPED AT LEAST THREE TIMES AROUND
PIPE THREADS.
11. ALL GATE AND ELECTRIC VALVES SHALL BE INSTALLED WITH UNIONS ON THE DOWNSTREAM END OF THE VALVE
(REFER TO DETAILS).
12. ALL PIPE SHALL HAVE A FIRM UNIFORM BEARING FOR THE ENTIRE LENGTH OF EACH LINE, FREE OF ROCKS OR DEBRIS.
ALL TRENCHES CONTAINING PIPE AND/OR WIRES SHALL BE BACKFILLED WITH CLEAN TOPSOIL, FREE OF ALL LUMBER,
RUBBISH AND ROCKS OVER 1" IN SIZE, OR CLEAN SAND IF CLEAN TOPSOIL IS NOT AVAILABLE.
13. CONTRACTOR SHALL PROVIDE OWNER WITH ONE SET OF AS -BUILT RECORD DRAWINGS SHOWING EXACT ACTUAL
LOCATIONS OF ALL SPRINKLER EQUIPMENT. CONTRACTOR SHALL ORIENT OWNER WITH COMPLETE SYSTEM AND
CONTROLLER OPERATIONS, AND WINTERIZATION PROCEDURES.
14. CONTRACTOR SHALL SUPPLY AND INSTALL ALL EQUIPMENT SHOWN ON THE PLANS AND INDICATED IN THE
SPECIFICATIONS TO ACHIEVE PROPER OPERATION OF SAID EQUIPMENT. ALL EQUIPMENT INSTALLATIONS, ELECTRICAL
AND PLUMBING CONNECTIONS SHALL BE IN CONFORMANCE WITH ALL APPLICABLE CODES AND ORDINANCES, THESE
SPECIFICATIONS, AND THE MANUFACTURERS RECOMMENDATIONS WHETHER INDICATED ON THE DRAWINGS OR NOT.
15. CONTRACTOR SHALL INCLUDE IN HIS BID ONE FALL WINTERIZATION AND ONE SPRING ACTIVATION OF IRRIGATION
SYSTEM. THESE ACTIVITIES SHALL BE INCLUDED AS PART OF OWNER ORIENTATION PROCEDURES. ANY DAMAGE TO
THE IRRIGATION SYSTEM OR THE LANDSCAPE AS A RESULT OF FAILURE TO COMPLY WITH THESE REQUIREMENTS
SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
16. CONTRACTOR SHALL GUARANTEE IN WRITING ON HIS COMPANY LETTERHEAD ALL MATERIALS AND WORKMANSHIP FOR
A PERIOD OF ONE FULL YEAR FOLLOWING ACCEPTANCE OF SYSTEM INSTALLATION.
17. BACKFLOW PREVENTOR SHALL BE INSPECTED AND TESTED BY A CERTIFIED BACKFLOW DEVICE INSPECTOR. PROVIDE
OWNER WITH ONE COPY OF APPROVAL CERTIFICATE.
VERTICAL* NAVD 1988
HORIZONTAL: NAD 1983/1991
I
U M
CITY OF
RENTON
Planning/Building/Public Works Dept.
W-403611 R-403641
IN COMPLIANCE WITH CITY OF RENTON STANDARDS
CURRENT PLANNING
Matt Herrera 08/05/2019
WEATHERLY INN RENTON
FIELD4500 TALBOT RD S PAGE:AGE. OK:
P
RENTON, WA 98055 DRAWING NO:
IRRIGATION DETAILS AND SPECIFICATIONS IR-04
SHEET. 51 OF: