Loading...
HomeMy WebLinkAboutP_ARCH_Drawings_FFCC_190905_v1OWNEROWNEROWNEROWNER CITY OF RENTON, COMMUNITY SERVICESCITY OF RENTON, COMMUNITY SERVICESCITY OF RENTON, COMMUNITY SERVICESCITY OF RENTON, COMMUNITY SERVICES Phone: (425) 430-6617 Email: kbeymer@rentonwa.gov Email: rwoodruff@rentonwa.gov ARCHITECTARCHITECTARCHITECTARCHITECT BAYLIS ARCHITECTS, INC.BAYLIS ARCHITECTS, INC.BAYLIS ARCHITECTS, INC.BAYLIS ARCHITECTS, INC.Phone: (425) 454-0566 Fax: (425) 453-8075 STRUCTURAL ENGINEERSTRUCTURAL ENGINEERSTRUCTURAL ENGINEERSTRUCTURAL ENGINEER COUGHLIN PORTER LUNDEEN Phone: (206) 343-0460 Email: benb@cplinc.com CIVIL ENGINEERCIVIL ENGINEERCIVIL ENGINEERCIVIL ENGINEER COUGHLIN PORTER LUNDEENCOUGHLIN PORTER LUNDEENCOUGHLIN PORTER LUNDEENCOUGHLIN PORTER LUNDEEN Phone: (206) 343-0460 Email: keithk@cplinc.com SURVEYORSURVEYORSURVEYORSURVEYOR TERRANETERRANETERRANETERRANE Phone: (425)458-4488 Fax: (425) 671-0170 Email: theresaa@terrane.net TRAFFIC ENGINEERTRAFFIC ENGINEERTRAFFIC ENGINEERTRAFFIC ENGINEER TRANSPORTATION ENGINEERS NORTHWEST (TENW)TRANSPORTATION ENGINEERS NORTHWEST (TENW)TRANSPORTATION ENGINEERS NORTHWEST (TENW)TRANSPORTATION ENGINEERS NORTHWEST (TENW) Phone: (206) 361-7333 x101 Fax: (206) 361-7333 Email: mikeread@tenw.com LANDSCAPE ARCHITECTLANDSCAPE ARCHITECTLANDSCAPE ARCHITECTLANDSCAPE ARCHITECT WEISMAN DESIGN GROUP, INCWEISMAN DESIGN GROUP, INCWEISMAN DESIGN GROUP, INCWEISMAN DESIGN GROUP, INC Phone: (206) 322-xxxx Fax: (xxx) xxx-xxxx Email: Nick@wdginc.com GEOTECHNICAL GEOTECHNICAL GEOTECHNICAL GEOTECHNICAL ----SOILS ENGINEERSOILS ENGINEERSOILS ENGINEERSOILS ENGINEER RILEY GROUPRILEY GROUPRILEY GROUPRILEY GROUP Phone: (425) 415-0551 Fax: (425) 415-0311 Email: rwang@riley-group.com MECHANICAL/PLUMBING/FIREMECHANICAL/PLUMBING/FIREMECHANICAL/PLUMBING/FIREMECHANICAL/PLUMBING/FIRE SIDER + BYERSSIDER + BYERSSIDER + BYERSSIDER + BYERS Phone: (206) 285-2966 Email: Nathan@siderbyers.com ELECTRICAL ELECTRICAL ELECTRICAL ELECTRICAL SIDER + BYERSSIDER + BYERSSIDER + BYERSSIDER + BYERS Phone: (206) 285-2966 Email: ryan@siderbyers.com INTERIORSINTERIORSINTERIORSINTERIORS OBJECT SPACEOBJECT SPACEOBJECT SPACEOBJECT SPACE Phone: (206) 819-5020 Email: dwight@objectandspace.com 1055 S Grady Way Renton, WA 98057 Contact: Kelly Beymer Contact: Russ Woodruff 10801 Main Street, Suite 110 Bellevue, WA 98004 Contact: Meredith Everist 801 Second AVE, Suite 900 Seattle, Washington 98104 Contact: Ben Barlow 801 Second AVE, Suite 900 Seattle, Washington 98104 Contact: Keith Kruger 10801 Main Street, STE 102 Bellevue, WA 98004 Contact: Theresa Auld PO BOX 65254 Seattle, WA 98155 Contact: Mike Read 2329 E Madison ST Seattle, Washington 98112 Contact: Nick Hagan 17522 Bothell Way NE Bothell, WA 98011 Contact: Ricky Wang 192 Nickerson ST, Suite 300 Seattle, Washington 98109 Contact: Nathan Byers 192 Nickerson ST, Suite 300 Seattle, Washington 98109 Contact: Ryan Arp 3445 California AVE SW, Studio 1 Seattle, WA 98116 Contact: Dwight Doty BUILDING ENVELOPEBUILDING ENVELOPEBUILDING ENVELOPEBUILDING ENVELOPE JRS ENGINEERINGJRS ENGINEERINGJRS ENGINEERINGJRS ENGINEERING Phone: (206) 728-2358 Email: bcarmichael@jrsengineering.com12721 30th Avenue Northeast 2nd Floor Seattle, WA 98125 Contact: Brad Carmichael SUSTAINABILITY SUSTAINABILITY SUSTAINABILITY SUSTAINABILITY ARCH ECOLOGYARCH ECOLOGYARCH ECOLOGYARCH ECOLOGY Phone: (206) 860-2904 Email: nancyh@archecology.com1808 Bellevue Ave #202 Seattle, WA 98122 Contact: Nancy Henderson 1.GENERAL NOTES DO NOT RELIEVE THE CONTRACTOR FROM THE RESPONSIBILITIES DOCUMENTED IN AIA FORM A201 GENERAL CONDITIONS AND SUPPLEMENTAL GENERAL CONDITIONS OR INFORMATION CONTAINED WITHIN THE DRAWINGS OR PROJECT MANUAL. 2.THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES TO ASSURE COMPLIANCE WITH DRAWINGS AND PROJECT MANUAL. 3.CONSULTANT'S DRAWINGS INCLUDING BUT NOT LIMITED TO STRUCTURAL, CIVIL, MECHANICAL, ELECTRICAL, AND INTERIOR DESIGN ARE SUPPLEMENTARY TO THE DRAWINGS. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY AND ALL DISCREPANCIES IDENTIFIED BETWEEN THE CONSULTANT'S DRAWINGS WITH A WRITTEN REQUEST FOR CLARIFICATION. WORK INSTALLED IN CONFLICT WITH THE DRAWINGS AND PROJECT MANUAL SHALL BE CORRECTED BY THE CONTRACTOR AT THE CONTRACTOR'S EXPENSE. 4.DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION . WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED, BUT ARE OF A SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO APPROVAL BY THE ARCHITECT. 5.THE CONTRACTOR SHALL INVESTIGATE EXISTING CONDITIONS BEFORE BEGINNING WORK. 6.THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL ROUGH-IN DIMENSIONS FOR EQUIPMENT INDICATED IN THE DRAWINGS AND PROJECT MANUAL, AND PROVIDED BY OTHERS. 7.THE CONTRACTOR SHALL PROVIDE ALL BLOCKING, BUCK-OUTS, BACKING AND JACKS AS REQUIRED FOR THE WORK, UNLESS NOTED OTHERWISE. 8.SUBCONTRACTORS SHALL BE RESPONSIBLE FOR INSPECTING THE WORKMANSHIP OF SUBCONTRACTORS PRECEDING. DISCREPANCIES IN WORK SHALL BE REPORTED TO THE CONTRACTOR IMMEDIATELY. FAILURE TO DO SO IN A TIMELY MANNER SHALL BE CONSTRUED AS ACCEPTANCE OF THAT WORK. 9.SUBCONTRACTORS SHALL BE RESPONSIBLE FOR DAMAGE TO ADJACENT WORK CAUSED BY THE SUBCONTRACTOR, IT'S AGENTS, OR EMPLOYEES. SUBCONTRACTOR SHALL REPAIR SAID DAMAGE AT THE SUBCONTRACTOR'S EXPENSE. 10.THE USE OF WORD "PROVIDE" SHALL ALWAYS MEAN, "FURNISH, INSTALL, CONNECT OR SECURE" AS REQUIRED. 11.ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURERS WRITTEN INSTRUCTIONS AND TRADE ASSOCIATES ACCEPTED STANDARDS. 12.DO NOT SCALE DRAWINGS; USE WRITTEN DIMENSIONS. IN THE EVENT THAT DISCREPANCIES ARE FOUND IN THE DRAWINGS, THE CONTRACTOR SHALL IMMEDIATELY CLARIFY SAID CONDITION WITH THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. 13.ALL INFORMATION RELATED TO EXISTING CONDITIONS HAS BEEN REPRESENTED TO THE BEST KNOWLEDGE OF THE ARCHITECT. THE CONTRACTOR SHALL BE RESPONSIBLE TO FIELD VERIFY EXISTING CONDITIONS AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES THAT WOULD EFFECT THE CONSTRUCTION OF THE PROJECT BEFORE STARTING THE WORK. 14.DIMENSIONS ARE TO THE FACE OF FRAMING, FACE OF CONCRETE, GRID LINES, OR CENTERLINE OF COLUMNS, DOORS AND WINDOWS UNLESS NOTED OTHERWISE. 15.REFER TO ARCHITECTS' STANDARDS FOR SYMBOLS AND ABBREVIATIONS FOR CLARITY OF DRAWINGS. IF A SYMBOL OR ABBREVIATION IS IDENTIFIED ON THE ARCHITECTURAL DRAWINGS THAT IS IN DISCREPANCY WITH THE STANDARDS THE CONTRACTOR SHALL NOTIFY THE ARCHITECT FOR CLARIFICATION. 16.REPETITIVE FEATURES NOT FULLY SHOWN OR NOTED ON THE DRAWINGS SHALL BE COMPLETELY PROVIDED AS IF DRAWN IN FULL. PROJECT NAME:PROJECT NAME:PROJECT NAME:PROJECT NAME:FAMILY FIRST COMMUNITY CENTER PROJECT NUMBER:PROJECT NUMBER:PROJECT NUMBER:PROJECT NUMBER:TBD PROJECT ADDRESS:PROJECT ADDRESS:PROJECT ADDRESS:PROJECT ADDRESS:16022 116TH AVE SE TAX ASSESSOR'S #:TAX ASSESSOR'S #:TAX ASSESSOR'S #:TAX ASSESSOR'S #:282305-9034 PROJECT JURISDICTION:PROJECT JURISDICTION:PROJECT JURISDICTION:PROJECT JURISDICTION:CITY OF RENTON SITE AREA: SITE AREA: SITE AREA: SITE AREA: 100,165 SF LAND USE ZONING: LAND USE ZONING: LAND USE ZONING: LAND USE ZONING: R-6 OCCUPANCY GROUP (PER IBC 303):OCCUPANCY GROUP (PER IBC 303):OCCUPANCY GROUP (PER IBC 303):OCCUPANCY GROUP (PER IBC 303):A-3, B, E TYPE OF CONSTRUCTIONTYPE OF CONSTRUCTIONTYPE OF CONSTRUCTIONTYPE OF CONSTRUCTION VB BUILDING HEIGHT:BUILDING HEIGHT:BUILDING HEIGHT:BUILDING HEIGHT:31'-3" ALL WORK SHALL CONFORM TO ALL APPLICABLE BUILDING CODES AND ORDINANCES. ANY CONFLICT WHERE THE METHOD OR STANDARDS OF INSTALLATION OF THE MATERIALS SPECIFIED DO NOT EQUAL OR EXCEED THE REQUIREMENTS OF THE APPLICABLE CODE OR ORDINANCES, THE CODE OR ORDINANCES SHALL GOVERN, IN THE EVENT THIS OCCURS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY. SUBSECTIONS OF THE CODE ARE LISTED HERE FOR GENERAL REFERENCE, BUT DO NOT RELEASE THE CONTRACTOR FROM CONFORMING TO ALL APPLICABLE BUILDING CODES AND ORDINANCES APPLICABLE CODES: 2015 INTERNATIONAL BUILDING CODE (IBC) 2015 WASHINGTON STATE AMENDMENTS TO IBC 2015 WASHINGTON STATE ENERGY CODE 2015 INTERNATIONAL FIRE CODE WITH WASHINGTON STATE AMENDMENTS 2015 INTERNATIONAL MECHANICAL CODE WITH WASHINGTON STATE AMENDMENTS 2015 UNIFORM PLUMBING CODE WITH WASHINGTON STATE AMENDMENTS 2014 NATIONAL ELECTRICAL CODE ICC/ANSI A117.1-2009 AS INCLUDED IN THE GOVERNING JURISDICTION THE APPLICANT PROPOSES TO DEVELOP A ONE-STORY BUILDING WITH SURFACE PARKING ON PARCEL # 282305-9034. THE PROPOSED PROJECT WILL BE LOCATED SOUTH OF THE EXISTING ELEMENTARY SCHOOL. THE PROPOSED DEVELOPMENT WILL BE A COMMUNITY CENTER WITH APPROXIMATELY 21,100 GSF AND 92 PARKING STALLS. THE PROPOSED COMMUNITY CENTER WILL BE OPEN TO THE GENERAL PUBLIC AND WILL OFFER SERVICES SUCH AS AFTER SCHOOL PROGRAMS AND ACTIVITIES, HEALTH CARE OFFICES WITH LABS, COUNSELING SERVICES, CHILDCARE FOR FACILITY USERS, COMMUNITY GARDEN AND DEMONSTRATION KITCHEN, A GYM, YOGA, DANCE AND FITNESS PROGRAMS. THE CONSTRUCTION TYPE IS V-B. THE PROPOSED BUILDING WILL BE A SUSTAINABLE DESIGN WITH THE GOAL OF LEED SILVER AND WILL INCLUDE SUCH FEATURES AS HEAVY TIMBER WOOD FRAMING AND NATURAL LIGHT. BUILDING MATERIALS: WOOD FRAME CONSTRUCTION INCLUDING GLULAM BEAMS AND COLUMNS, METAL SIDING FOR EXTERIOR WALLS, FIBERGLASS WINDOWS AND PVC ROOF MEMBRANE. S 800 FT OF N 830 FT OF W 840 FT OF NW 1/2 OF NW 1/4 LESS CO RD MAXIMUM BUILDING COVERAGE:MAXIMUM BUILDING COVERAGE:MAXIMUM BUILDING COVERAGE:MAXIMUM BUILDING COVERAGE:40% BUILDING COVERAGE PROVIDED:BUILDING COVERAGE PROVIDED:BUILDING COVERAGE PROVIDED:BUILDING COVERAGE PROVIDED: MAXIMUM IMPERVIOUS SURFACE AREA:MAXIMUM IMPERVIOUS SURFACE AREA:MAXIMUM IMPERVIOUS SURFACE AREA:MAXIMUM IMPERVIOUS SURFACE AREA:55% IMPERVIOUS SURFACE PROVIDED:IMPERVIOUS SURFACE PROVIDED:IMPERVIOUS SURFACE PROVIDED:IMPERVIOUS SURFACE PROVIDED: MAXIMUM WALL PLATE HEIGHT:MAXIMUM WALL PLATE HEIGHT:MAXIMUM WALL PLATE HEIGHT:MAXIMUM WALL PLATE HEIGHT:24'-0" MAXIMUM BUILDING HEIGHT PROPOSEDMAXIMUM BUILDING HEIGHT PROPOSEDMAXIMUM BUILDING HEIGHT PROPOSEDMAXIMUM BUILDING HEIGHT PROPOSED 31'31'31'31'----3"3"3"3" PROJECT SITE PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: COPYRIGHT 2019 BAYLIS ARCHITECTS INCORPORATED ALL RIGHTS RESERVED C THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, IS THE PROPERTY OF BAYLIS ARCHITECTS INC., AND MAY NOT BE REUSED, IN WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF BAYLIS ARCHITECTS INCORPORATED. REVISIONS:9/10/2019 7:43:41 PMA001 COVER SHEET 16-0996 Author CheckerFAMILY FIRST COMMUNITYCENTERRENTON, WALAND USE PERMITDRAWINGS09/05/19ARCHITECTURALARCHITECTURALARCHITECTURALARCHITECTURAL A100.a OVERALL SITE PLAN A100.b SITE PLAN A101 FLOOR PLAN A102 ENLARGED FLOOR PLAN A103 ENLARGED FLOOR PLAN A104 ROOF PLAN A105 RCP A201 EXTERIOR ELEVATIONS A301 BUILDING SECTIONS A504 WINDOW SCHEDULE A505 GALLERY GLAZING ELEVATION A601 CONCRETE AND SITE DETAILS A602 CONCRETE DETAILS A603.1 EXTERIOR DETAILS A603.2 EXTERIOR DETAILS A604 DOOR DETAILS - EXTERIOR A605 WINDOW DETAILS - EXTERIOR A607 ROOF DETAILS A608 ROOF DETAILS SHEET INDEX GENERAL INFORMATION AND DATA SHEETSGENERAL INFORMATION AND DATA SHEETSGENERAL INFORMATION AND DATA SHEETSGENERAL INFORMATION AND DATA SHEETS A001 COVER SHEET A003 CODE SUMMARY A010a ACCESSIBILITY STANDARDS GENERAL AND COMMON AREAS SURVEYSURVEYSURVEYSURVEY SURVEY SURVEY CIVILCIVILCIVILCIVIL C100 DEMOLITION & TESC PLAN C110 DEMOLITION & TESC DETAIL C200 GRADING & DRAINAGE PLAN C300 PAVING PLAN C400 UTILITY PLAN STRUCTURALSTRUCTURALSTRUCTURALSTRUCTURAL S101 FOUNDATION PLAN S102 ROOF FRAMING PLAN PROJECT DATA VICINITY MAP BUILDING ENVELOPEBUILDING ENVELOPEBUILDING ENVELOPEBUILDING ENVELOPE BE-000 GENERAL NOTES AND INDEX BE-010 AIR BARRIER DIAGRAMS BE-020 WATERPROOFING ASSEMBLIES BE-030 WATERPROOFING EXTENTS DIAGRAMS BE-100 SLAB ON GRAGDE DETAILS LANDSCAPELANDSCAPELANDSCAPELANDSCAPE L100 SITE PLAN L200 LANDSCAPE PLAN L201 LANDSCAPE SCHEDULE & DETAILS L300 IRRIGATION PLAN L301 IRRIGATION LEGEND & DETAILS L302 IRRIGATION DETAILS L400 LANDSCAPE DETAILS L401 LANDSCAPE DETAILS ELECTRICALELECTRICALELECTRICALELECTRICAL E001 COVER SHEET E002 SCHEDULES E100 SITE PLAN - NEW UTILITY POWER AND TELECOMM PLAN E101 FLOOR PLAN - POWER PLAN E201 FLOOR PLAN - LIGHTING PLAN GENERAL NOTES PROJECT DESCRIPTION LEGAL DESCRIPTION PROJECT DIRECTORY APPLICABLE CODES FAMILY FIRST COMMUNITY CENTER LAND USE REQUIREMENTS MECHANICALMECHANICALMECHANICALMECHANICAL M001 COVER SHEET M002 SCHEDULES M101 HVAC FLOOR PLAN M102 HVAC ROOF PLAN M301 DETAILS INTERIORSINTERIORSINTERIORSINTERIORS I-1.0 FLOOR PLAN I-1.1 FLOOR FINISH PLAN I-3.0 INTERIOR ELEVATIONS I-3.1 INTERIOR ELEVATIONS I-3.2 INTERIOR ELEVATIONS I-3.3 INTERIOR ELEVATIONS I-3.4 INTERIOR ELEVATIONS I-3.5 INTERIOR ELEVATIONS I-3.6 INTERIOR ELEVATIONS I-3.7 INTERIOR ELEVATIONS I-3.8 INTERIOR ELEVATIONS I-7.0 FINISH SCHEDULES PARKING PLUMBINGPLUMBINGPLUMBINGPLUMBING P001 COVER SHEET P002 SCHEDULES P101 PLUMBING FLOOR PLAN P102 ROOF PLAN P301 DETAILS NO. DESCRIPTION DATE FAMILY FIRST COMMUNITY CENTER WATER EASEMENT 10' - 0"EXISTING SCHOOL EXISTING PARKING EXISTING PROPERTY LINEBALL FIELD PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: COPYRIGHT 2019 BAYLIS ARCHITECTS INCORPORATED ALL RIGHTS RESERVED C THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, IS THE PROPERTY OF BAYLIS ARCHITECTS INC., AND MAY NOT BE REUSED, IN WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF BAYLIS ARCHITECTS INCORPORATED. REVISIONS:9/10/2019 7:43:45 PMA100.a OVERALL SITE PLAN 16-0996 Author CheckerFAMILY FIRST COMMUNITYCENTERRENTON, WALAND USE PERMITDRAWINGS09/05/19164 0 6432 1/32"=1'-0" 8 1/32" = 1'-0"1 SITE PLAN - SCHOOL NO. DESCRIPTION DATE 460.08 465.79465.53465.28465.03465.02465.13467.84465.33465.70465.69465.34465.34465.33465.67465.64465.32465.33466.87449.24 449.23 CE8 T C R0.5CCCCC APP Z-LOOPLOOPLOOPLOOPLOOP OLOOP1LOOP1LOOP1LOOP1LOOP1 OGP Z-SM BM /NORTH RIM SM 640 2001200220032004200520062013201420152016201720182019202020212022202320242036 2037 466.97 BOLBOLACTIVITY POSTEAVEEAVEEAVE LUM LUMGPPP #317005N 01°46'57" E 799.95'N 89°10'36" W 810.34'COCOCOCO(2)14" CED18" FIR24" FIR13" SPR8" EVG8" EVGROOF EL=482.2'ROOF EL=482.1'ROOF EL=482.1'COLFF EL=459.7'FF EL=459.7'FF EL=459.7'FF EL=459.7'FF EL=459.7'4654654654654654604604604554504504504504 6 8467467 467467466466 4664664664 6 6 466466466464463463462462461459 459 4594594584584574544534524524524 5 1 451451451 449449FAMILY FIRST COMMUNITY CENTER WATER EASEMENT 10' - 0" N E W EXISTING SCHOOL DROP OFF ZONE ENTRYEXIT EXISTING PARKING 21 STALLS PROPOSED PROPERTY LINE PROPOSED PROPERTY LINE EXISTING PROPERTY LINEPROPOSED PROPERTY LINE EXISTING PROPERTY LINE PROPOSED PROPERTY LINEN89°10'39"W 495.78'N00°49'21"E 237.08'N89°10'39"W 29.93'N00°49'21"E 153.85'116TH AVEREFUSE & RECYCLEEXISTING BALL FIELD TYP20'-0"DRIVEWAYVAN MIN. 24' - 0" 2 2 6 ' - 0 " SETBACK, TYP.10' - 0" SIDEYARDC C C C C C C C C C CC C C C C C C C C C CR 25' - 0" BUS LANE R 45' - 0"R 45' - 0"R 50' - 0"R 45' - 0"R 50' - 0"R 25' - 0"20'-0"CCCCCCCCCCTRANSFORMER PAD PERVIOUS CONC. (ALT) PERVIOUS CONC. (ALT) PERVIOUS CONC. (ALT)MIN.24' - 0"9' - 0"REARYARD SETBACK 25' - 0"SIDEYARD SETBACK10' - 0"SIDEYARD SETBACK 10' - 0" FRONTYARD SETBACK 25' - 0"5' - 0"SIDEYARD SETBACK2' - 0"PARKING OVERHANGR= 50.00' = 37°45'38" L = 32.95' ∆ R= 50.50' = 56°43'43" L = 50.00' ∆ N71°51'17" E 37.46' TYP 9' - 0"TYP18' - 0"TYP 20' - 0"TYP9' - 0"TYP8' - 6"TYP 16' - 0"TYP9' - 0"TYP 20' - 0" TYP 9' - 0"TYP9' - 0"TYP 20' - 0"TYP8' - 6"TYP 16' - 0" MIN. 24' - 0"9' - 0" TYP 9' - 0"TYP20' - 0"8' - 0" TYP 5' - 0" PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: COPYRIGHT 2019 BAYLIS ARCHITECTS INCORPORATED ALL RIGHTS RESERVED C THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, IS THE PROPERTY OF BAYLIS ARCHITECTS INC., AND MAY NOT BE REUSED, IN WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF BAYLIS ARCHITECTS INCORPORATED. REVISIONS:9/10/2019 7:43:49 PMA100.b SITE PLAN 16-0996 CL CheckerFAMILY FIRST COMMUNITYCENTERRENTON, WALAND USE PERMITDRAWINGS09/05/191" = 20'-0"1 SITE PLAN 105 0 4020 1"=20'-0" NO. DESCRIPTION DATE DN DN3 A301 2 A301 1 A301 1 1 1.4 2 2 3 3 4 4 5 5 6 6 7 7 A A B B C C D D E E E.2 F F98' - 0"31' - 8"8.2 8.2 11 11 10 10 8' - 6" ELEC RM 115 LNDRY 125 TEEN ROOM 123 YOUTH ROOM 122 WOMEN'S RR 126 SPONSOR 128 LUNCH ROOM 124 MAKER SPACE 1 & 2 106 KITCHEN - DEMO 104 FITNESS ROOM 108 DANCE/CLASS 107 GYMNASIUM 110 WAITING ROOM HP101 MEDICAL POD HP109 CHECK-IN HP102 WORK ROOM HP103 A201 1 A201 2 A2014 EXAM RM 1 HP119 EXAM RM 2 HP120 MED HP112 LAB/STERILE HP114 CLINIC MGR HP104 COUNSELING 2 HP106 DENTAL EXAM HP108 A102 1129' - 8"STAFF CARRELS 130 CHECK-IN 131 SPONS ADMIN 129 MEN'S RR 127 ADMIN 121 RR 120 BABY-TODDLER ROOM 119 VESTIBULE 101 COUNSELING 1 HP105 SRVR/STOR HP113 PANO HP110 EXAM RM 3 HP121 EXAM RM 4 HP122 EXAM RM 5 HP123 EXAM RM 6 HP124 RR HP115 MEN'S RESTROOM 113 4 A301 MTG ROOM 103 STOR 105 GROUP ED HP118 CORR HP117 JAN 116 JAN 118 FAMILY RR 117 WOMEN'S LOCKERS WOMEN'S RESTROOM 114 ADMIN CORR LOBBY 102 GALLERY 132 EXIT MEN'S LOCKERS COMMUNITY GARDEN CHECK-IN A136 STAFF RR HP111 DENTAL EQUIP HP107 PHLEB HP116 STOR 111 FIRE & WATER 112 19' - 0"64' - 10"52' - 2"35' - 0"71' - 11" 7' - 10"11' - 2"19' - 0"19' - 0"3' - 0" 10' - 6"19' - 0"19' - 0"19' - 0"7' - 10"11' - 2"19' - 0"19' - 0"3' - 0"16' - 0"19' - 0"71' - 11"16' - 5 1/2"26' - 6 1/2"12' - 0"34' - 4"40' - 4"TYPICAL 19' - 0" HP104 HP103 HP118b HP120 HP119 HP114a HP106 HP101b 128129 118 131a HP113 102a HP105 106a HP115 HP114b HP111 HP121 HP122 HP123 HP101a 107 124b 123 132 HP124 103a 127 105 104 108b 106b 117 114 119 122 120 111a 112a HP107 HP112 HP109 115 103b HP117 STOR 109 CORR 108a 109 130 131b 113 110c112b E5 E5 E4 E13 E13 E13 E1 E1 E7 E1 E1E1 E1 E1 E1 E1 E1 E1 E2E2 E9 E7 E5 E5 E5 EW1 EW1 EW1 EW1 EW1 EW4 EW4 EW4 EW1 EW1 EW1 7'-6 1/2"5'-5 1/4"8'-6 1/2"7'-9 1/8"9 5/8" 3'-8"14'-5"14'-4 1/2" 5'-4"14'-8"15'-0"9'-5 1/2"16'-2"9'-10 1/4"6'-4 3/8"1'-1 1/4"21'-1"10'-0"7'-7 3/4"4'-7 3/4"7'-8 1/4"7'-8 7/8"PW3 PW3 PW3 PW1 PW1 PW1 PW1 PW2 PW1 PW1 PW1 PW1 PW1 PW1 PW3 PW3 PW1 PW1 PW3 PW3 PW1 116 PW3 5'-6" PW1PW1 PW3 PW1 PW3 PW1 PW3 PW2 461' - 6" 459' - 10" 101 110b 5.5 5.5 8 8 9 9 E.315' - 6"16' - 2"16'-5 1/2"26'-6 1/2"12'-0"34'-4"8'-8"EW1 E5 EW3 EW2 EW2 EW3 EW3 EW1 PW1 ROOF OVERHANG ABOVE E4 SUN SHADE ABOVE ROOF OVERHANG ABOVE SUN SHADE ABOVE SUN SHADE ABOVE SUN SHADE ABOVE ROOF OVERHANG ABOVE SUN SHADE ABOVE ROOF OVERHANG ABOVE 5% slope 5% slope 102b D.S. D.S. D.S. D.S.D.S.D.S. 111b 124a 124b 125126 HP118a PW1 PW3 1' - 5"GYM DIVIDER ABOVE 30°460' - 6" PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: COPYRIGHT 2019 BAYLIS ARCHITECTS INCORPORATED ALL RIGHTS RESERVED C THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, IS THE PROPERTY OF BAYLIS ARCHITECTS INC., AND MAY NOT BE REUSED, IN WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF BAYLIS ARCHITECTS INCORPORATED. REVISIONS:9/10/2019 7:43:54 PMA101 FLOOR PLAN 16-0996 Author CheckerFAMILY FIRST COMMUNITYCENTERRENTON, WALAND USE PERMITDRAWINGS09/05/1921 0 84 16 1/8"=1'-0" 1/8" = 1'-0"1 FLOOR PLAN NO. DESCRIPTION DATE FLOOR PLAN 461' - 6" 2 A301 1 A301 11.42345678.21110 E1 E3 E7 E6 E9 E8 E1 E10 5.589 E12 E12 E5 E4 E2E1 E9 25' GALLERY HEIGHT33'-3" MAX HEIGHTFLOOR PLAN 461' - 6" LOW ROOF 471' - 6" 3 A301ABC D E E.2 F 10'-0"E1 E1 E5 E8 E13 E7 E9 E12 MECHANICAL WELL E.3 E13E9E12 E3 E4E4 E1 E2 E6 FLOOR PLAN 461' - 6" 2 A301 1 A30111.4 2 3 4 5 6 7 8.2 1110 E1 E3 E6 E7 E1 E10 E12 E9 E8 5.5 8 9 E13 E12E9 E10 2' - 1"E5 E4 E1 E2 33'-3" MAX HEIGHT25' GALLERY HEIGHTFLOOR PLAN 461' - 6" LOW ROOF 471' - 6" 3 A301 ABCDEE.2F 10'-0"1'-8"E1 E8 E13 E.3 E9E12 E10 A B FLUSH 11" UP 1" DNBA B B B B B B B B B B B B B B A A A A A A A A A A A A A A A A 21 5 7 8 10 12 13 163 4 6 9 11 14 15 ALIGN PER ELEVATIONS PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: COPYRIGHT 2019 BAYLIS ARCHITECTS INCORPORATED ALL RIGHTS RESERVED C THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, IS THE PROPERTY OF BAYLIS ARCHITECTS INC., AND MAY NOT BE REUSED, IN WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF BAYLIS ARCHITECTS INCORPORATED. REVISIONS:9/10/2019 7:44:11 PMA201 EXTERIOR ELEVATIONS 16-0996 Author CheckerFAMILY FIRST COMMUNITYCENTERRENTON, WALAND USE PERMITDRAWINGS09/05/19NUMBER DESCRIPTION E1 MEMBRANE ROOF, TYP W PRE-FINISHED METAL FASCIA E2 GREEN ROOF (BID ALTERNATE) E3 BEAM PER STRUCTURAL E4 RAIN COLLECTION CISTERN (BID ALTERNATE) E5 GUTTER E6 GLULAM COLUMN E7 FIBERGLASS GLAZING SYSTEM E8 METAL SIDING W ALTERNATING 1" REVEAL PATTERN E9 CORRUGATED METAL SIDING E10 HOLLOW METAL DOOR E12 FIBERGLASS WINDOW, TYP. E13 ALUMINUM SUNSHADE ELEVATION KEYNOTES 1/8" = 1'-0"1 NORTH ELEVATION 1/8" = 1'-0"4 WEST ELEVATION 21 0 84 16 1/8"=1'-0" 1/8" = 1'-0"2 SOUTH ELEVATION 21 0 84 16 1/8"=1'-0" 1/8" = 1'-0"3 EAST ELEVATION 21 0 84 16 1/8"=1'-0" 21 0 84 16 1/8"=1'-0" 1/4" = 1'-0" WALL PATTERN DIAGRAM NO. DESCRIPTION DATE FLOOR PLAN 461' - 6" 2 A301 1 A30111.4 2 3 4 5 6 7 8.2 1110 MAX WALL HT 485' - 6"24' - 0"1' - 8"VESTIBULE 101 LOBBY 102 GALLERY 132 GYMNASIUM 110 FOOTING PER STRUCTURAL, TYP SLAB ON GRADE WOOD GYMNASIUM FLOOR OVER DEPRESSED SLAB ON GRADE 5.5 8 9 5'-10 1/4"25'-8"R2 FC1 FC1 FC1 FC2 R1 3 A301 B C D E E.2 F YOUTH ROOM 122 WAITING ROOM HP101 CORR HP117 SRVR/STOR HP113 PANO HP110 MEDICAL POD HP109 10' - 0"4 A301 ADMIN 121 GALLERY 132 CORR HP117 RR HP115 LAB/STERILE HP114 BEAMS PER STRUCTURAL ACOUSTICAL CEILING AT HEALTHPOINT CLINIC FOOTINGS PER STRUCTURAL, TYP E.3 R1 R2 R1 R3R3 FC1 FLOOR PLAN 461' - 6" LOW ROOF 471' - 6" 3 A301 ROOF 479' - 6" A B C D E E.2 GYMNASIUM 110 1' - 8"AVG GRADE PLANE 455' - 0" 4 A301 A351 4R1 FC2 29'-6 3/4"4'-10"8'-0"10'-0"FLOOR PLAN 461' - 6" 2 A301 CEILING 469' - 0" 1 A30111.4 2 3 4 5 6 7 8.2 11105.5 8 9 7'-6"1'-8"31'-6 1/4"GYMNASIUM 110 DANCE/CLASS 107EXAM RM 1 HP119 CORR HP117WORK ROOM HP103 MAKER SPACE 1 & 2 106 MTG ROOM 103 R2 FC1 R1 FC1 FC1 FC2 R1 PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: COPYRIGHT 2019 BAYLIS ARCHITECTS INCORPORATED ALL RIGHTS RESERVED C THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, IS THE PROPERTY OF BAYLIS ARCHITECTS INC., AND MAY NOT BE REUSED, IN WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF BAYLIS ARCHITECTS INCORPORATED. REVISIONS:9/10/2019 7:44:14 PMA301 BUILDING SECTIONS 16-0996 Author CheckerFAMILY FIRST COMMUNITYCENTERRENTON, WALAND USE PERMITDRAWINGS09/05/191/8" = 1'-0"3 SECTION THRU GALLERY AND GYM 1/8" = 1'-0"1 SECTION THRU CHILDCARE & CLINIC 1/8" = 1'-0"2 SECTION THRU GYM 21 0 84 16 1/8"=1'-0" 21 0 84 16 1/8"=1'-0" 21 0 84 16 1/8"=1'-0" 1/8" = 1'-0"4 SECTION THRU MECH DECK need review NO. DESCRIPTION DATE CORRUGATED METAL SIDING 3" x 3" x1/4" METAL FRAME CONC. FILLED 6" DIA. STL. PIPE LIFT PIN 3"x 3"x 1/4" STL. ANGLE 3" x 3" x 1/4" STL. METAL FRAME 5/16" LIFT PIN 3" x 3" ANGLE WELDED TO FRAME "BOTTON" TO HOLD PIN IN UP POSITION 1" DIAM. GALV. PIPE SLEEVELIFT PIN JAMB 7' - 0"2' - 0"12' - 0"2' - 0" CONC. FILLED 6" DIA STEEL PIPE CORRUGATED METAL SIDING TO MATCH COMMUNITY CENTER, TYP. 1 A610 A61036" CONCRETE SLAB CONCRETE CURB SLOPE CORRUGATED METAL SIDING, TYP. 11'-0"16'-0"4X4 HSS 12'-0"5'-6" GYM PLANTER PER LANDSCAPE PLANTER PER LANDSCAPE CONC. APRON 6'-0" 2A A610 5B A610 16"8"12"4"8"6" CONCRETE SLAB CORRUGATED METAL SIDING, TYP. 2% 4x4 HSS 12" AC PAVING THK. CURB 2B PROJECT NUMBER: DRAWN BY: PROJECT MANAGER: COPYRIGHT 2019 BAYLIS ARCHITECTS INCORPORATED ALL RIGHTS RESERVED C THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, IS THE PROPERTY OF BAYLIS ARCHITECTS INC., AND MAY NOT BE REUSED, IN WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF BAYLIS ARCHITECTS INCORPORATED. REVISIONS:9/10/2019 7:44:16 PMA610 REFUSE/RECYCLING DETAILS 16-0996 Author CheckerFAMILY FIRST COMMUNITYCENTERRENTON, WALAND USE PERMITDRAWINGS09/05/191/2" = 1'-0"1 GARBAGE ENCLOSURE DETAIL 1/4" = 1'-0"3 ELEVATION OF GARBAGE ENCLOSURE 1/4" = 1'-0"10 GARBAGE ENCLOSURE - PLAN 1" = 1'-0"2A GARBAGE ENCLOSURE FOOTING DETAL NO. DESCRIPTION DATE