Loading...
HomeMy WebLinkAboutP_Site_Lighting_FFCC_190905_v1FAMILY FIRSTCOMMUNITY CENTERNEWEXISTING SCHOOLDROP OFF ZONEENTRY EXITEXISTINGPARKING21 STALLSPROPOSEDPROPERTY LINEPROPOSED PROPERTY LINEEXISTING PROPERTY LINE PROPOSEDPROPERTY LINEEXISTING PROPERTY LINEPROPOSED PROPERTY LINE N89°10'39"W 495.78'N00 °49'21"E 237.08'N89°10'39"W 29.93'N00 °49'21"E 153.85' 116TH AVE REFUSE & RECYCLE EXISTINGBALL FIELDDRIVEWAYVANC C C C C C C C C C C C C C C C C C C C C C BUS LANECCCCCCCCCCSIDEYARDSETBACKR= 50.00' = 37°45'38"L = 32.95'ΔR= 50.50' = 56°43'43"L = 50.00'ΔN71°51'17"E 37.46'1234457689910101010101010101010N O T F O R C ON S T RU C T I O N192 Nickerson, Suite #300Seattle, Washington 98109Phone: 206.285.2966 PROJECT NUMBER:DRAWN BY:PROJECTMANAGER:COPYRIGHT 2017BAYLIS ARCHITECTSINCORPORATEDALL RIGHTS RESERVEDCTHIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATEDHEREIN, IS THE PROPERTY OF BAYLIS ARCHITECTS INC., AND MAYNOT BE REUSED, IN WHOLE OR IN PART, WITHOUT THE WRITTENCONSENT OF BAYLIS ARCHITECTS INCORPORATED.REVISIONS:18083NBCheckerFAMILY FIRST COMMUNITY CENTER RENTON, WANO.DESCRIPTIONDATERA, CHLAND USE PERMIT DRAWINGS 09/05/19E100SITE PLAN -NEW UTILITY POWER ANDTELECOMM PLANX1.EXISTING UTILITY POLE WITH OVERHEAD 3-PHASE POWER ANDTELE/COMM INFRASTRUCTURE. CONTRACTOR TO PROVIDE NEWCONDUIT SERVICE DROPS FOR EACH UTILITY PROVIDE FORUNDERGROUND UTILITY SERVICES TO COMMUNITY CENTERBUILDING. CONTRACTOR TO COORDINATE WITH EACHPROVIDER AND WILL PROVIDE PATHWAY AND INFRASTRUCTUREAS REQUIRED FOR EACH SERVICE CONNECTION.2.NEW UNDERGROUND UTILITY STREET CROSSING PER CITY OFRENTON REQUIREMENTS.3.NEW RECESSED IN-GRADE UTILITY JUNCTION BOXES. PROVIDE 1BOX FOR POWER, TELEPHONE AND CABLE TV ACCORDING TOUTILITY PROVIDERS REQUIREMENTS.4.NEW UNDERGROUND SHARED UTILITY TRENCH WITH POWER,TELEP[HONE AND CABLE TV SERVICES.5.NEW PAD MOUNTED TRANSFORMER PROVIDED BY PSE.CONTRACTOR TO PROVIDE BELOW-GRADE VAULT, VAULT LID,AND CONDUIT TERMINATIONS PER PSE REQUIREMENTS.BELOW-GRADE VAULT TO BE LOCATED A MINIMUM OF 10 FEETCLEAR OF ANY COMBUSTIBLE CONSTRUCTION.6.NEW UNDERGROUND SECONDARY SERVICE POWER FEEDERS,BY CONTRACTOR, FROM TRANSFORMER VAULT TO ELECTRICALROOM SERVICE ENTRANCE. SEE ONE-LINE ON SHEET E0.3 FORCONDUIT AND CABLE SIZES.7.NEW RECESSED IN-GRADE UTILITY JUNCTION BOXES FORTELE/COMM SERVICES.8.NEW UNDERGROUND TELEPHONE AND CABLE TV SERVICES.CONTRACTOR TO PROVIDE CONDUIT AND CABLING FROMJUNCTION BOX TO ELECTRICAL ROOM SERVICE ENTRANCE.9.EXISTING PARKING LOT LIGHTS TO BE RELOCATED, AS NEEDED,TO SUIT NEW LAYOUT.10.NEW POLE MOUNTED PARKING LOT LIGHTS.